Optimizing 4d Emittance Measurements Using the Pinhole Scan Technique

Accurate measurement of electron beam emittance is essential for optimizing high-brightness electron sources. The Pinhole Scan Technique measures the 4D phase space and hence the emittance by measuring the beam profile after clipping the beam using a pinhole followed by a drift section and then scanning the beam over the pinhole. This technique has been implemented in low energy (< 200 keV) beamlines at both Cornell University and Arizona State University. However, the technique poses several practical challenges. In this work, we analyze and address key issues affecting the 4D phase space and emittance measurements using this technique. We identify and investigate sources of inaccuracies like the pinhole aspect ratio, beam divergence, position-momentum correlations in the phase space, and the point-spread-function of the detector and suggest techniques to minimize them. Our findings offer a pathway to more accurate 4D phase space characterization in advanced electron beam systems.

42 ENGINEERING↗

Impact of superlattice size on quantum efficiency and polarization in MOCVD-grown strained GaAs/GaAsP photocathodes

Strained superlattice GaAs photocathodes are crucial for providing high photocurrent beams of spin-polarized electrons at several accelerator facilities including the Continuous Electron Beam Accelerator Facility at Thomas Jefferson National Accelerator Facility and the future Electron–Ion Collider at Brookhaven National Laboratory. Here, in this work, we study the effects of varying the number of superlattice pairs on the polarization and photocurrent of the photocathodes. We observe a saturation in quantum efficiency beyond 30 pairs, with additional layers yielding minimal photocurrent improvement while noticeably reducing the polarization of the beam.

Chemical vapor deposition↗

Characterization of transverse electron pulse trains using RF powered traveling wave metallic comb striplines

Advancements in ultrafast electron microscopy have allowed elucidation of spatially selective structural dynamics. However, as the spatial resolution and imaging capabilities have made progress, quantitative characterization of the electron pulse trains has not been reported at the same rate. In fact, inexperienced users have difficulty replicating the technique because only a few dedicated microscopes have been characterized thoroughly. Systems replacing laser driven photoexcitation with electrically driven deflectors especially suffer from a lack of quantified characterization because of the limited quantity. The primary advantages to electrically driven systems are broader frequency ranges, ease of use and simple synchronization to electrical pumping. Here, we characterize the technical parameters for electrically driven UEM including the shape, size and duration of the electron pulses using low and high frequency chopping methods. At high frequencies, pulses are generated by sweeping the electron beam across a chopping aperture. For low frequencies, the beam is continuously forced off the optic axis by a DC potential, then momentarily aligned by a countering pulse. Using both methods, we present examples that measure probe durations of 2 ns and 10 ps for the low and high frequency techniques, respectively. Here, we also discuss how the implementation of a pulsed probe affects STEM imaging conditions by adjusting the first condenser lens.

36 MATERIALS SCIENCE↗

An Anomalous Electron Configuration Among 3d Transition Metal Atoms

Physical properties of materials are mainly determined by valence electron configurations, where different valence shells would induce divergent phenomena. In compounds containing Sc 2+ , 3d electron occupancy is expected, same as other transition metal atoms like Ti 3+ . But this situation still awaits experimental verification. In this work, we selected ScS to measure the valence electron density and orbital population of Sc2+ through delicate quantitative convergent-beam electron diffraction. Though the [Ar]3d 1 configuration is confirmed in ionic Sc 2+ , the unintuitive occupation of 4s orbital is concluded with the absence of 3d orbital features around Sc-atom sites and nearly bare population of t2g orbital. It should be the first time to report this special electron configuration in a transition metal compound, in which 4s rather than 3d orbital is preferred. Our findings reveal the distinct behavior of Sc, and probable ways to modulate material properties by controlling electron orbitals.

36 MATERIALS SCIENCE↗

A Review and Perspective on Cathodoluminescence Analysis of Halide Perovskites

Halide perovskite solar cells have achieved a certified efficiency of 25.2%, surpassing CdTe and CuInGaSe 2 , which have long been regarded as the most-efficient thin-film photovoltaic materials. As this exciting class of materials continues to mature, researchers will require characterization techniques capable of exposing the interplay among structure, chemistry, and optoelectronic properties to inform processing strategies and increase both device efficiencies and long-term stability. Cathodoluminescence microscopy is an ideal technique to provide such information due to the high spatial resolution and robust optical information acquired. Here, the current body of work related to cathodoluminescence analysis of halide perovskite materials for optoelectronic applications is surveyed. This review demonstrates how cathodoluminescence can monitor degradation due to environmental stressors, phase segregation resulting from material processing, and other halide perovskite-centric material issues. A persistent concern associated with e-beam-based analysis of halide perovskites is what effect the electron beam has on the material properties being probed. Addressing this, a detailed discussion is provided on the origin of the cathodoluminescence signal and a review of studies focused on revealing changes in the properties of halide perovskites resulting from e-beam excitation. Finally, a perspective on future opportunities to expand the role of cathodoluminescence analysis for halide perovskites is provided.

14 SOLAR ENERGY↗

Simulation Study of High-Precision Characterization of MeV Electron Interactions for Advanced Nano-Imaging of Thick Biological Samples and Microchips

The resolution of a mega-electron-volt scanning transmission electron microscope (MeV-STEM) is primarily governed by the properties of the incident electron beam and angular broadening effects that occur within thick biological samples and microchips. A precise understanding and mitigation of these constraints require detailed knowledge of beam emittance, aberrations in the STEM column optics, and energy-dependent elastic and inelastic critical angles of the materials being examined. This simulation study proposes a standardized experimental framework for comprehensively assessing beam intensity, divergence, and size at the sample exit. This framework aims to characterize electron-sample interactions, reconcile discrepancies among analytical models, and validate Monte Carlo (MC) simulations for enhanced predictive accuracy. Our numerical findings demonstrate that precise measurements of these parameters, especially angular broadening, are not only feasible but also essential for optimizing imaging resolution in thick biological samples and microchips. By utilizing an electron source with minimal emittance and tailored beam characteristics, along with amorphous ice and silicon samples as biological proxies and microchip materials, this research seeks to optimize electron beam energy by focusing on parameters to improve the resolution in MeV-STEM/TEM. This optimization is particularly crucial for in situ imaging of thick biological samples and for examining microchip defects with nanometer resolutions. Our ultimate goal is to develop a comprehensive mapping of the minimum electron energy required to achieve a nanoscale resolution, taking into account variations in sample thickness, composition, and imaging mode.

36 MATERIALS SCIENCE↗

Beam Dynamics of the Strong Hadron Cooler ERL at the Electron-Ion Collider

The Strong Hadron Cooler Energy Recovery Linac (SHC-ERL) for the Electron-Ion Collider (EIC) is required to produce an electron beam with a bunch charge of 1 nC, an average current of 100 mA, and a beam energy of both 150 and 55 MeV, with strict requirements for the transverse emittance, slice energy spread, and longitudinal distribution. This paper covers the design in detail, including preliminary considerations of higher order effects and diagnostics.

Deitrick, K.↗

Summer Student Internship: Experimental and modeling experiences

My internship at the Los Alamos National Laboratory has been an information-filled summer. Loren Espada-Castillo brought me into her project and helped mentor and guide me through the summer. The project that I was brought into was the process of shooting materials with electrons. The electron beam we used conducts a series of shots in which electrons are generated and then fired towards a target, the sample holder. The sample holder holds either a single sample or three samples. The sample holder also consists of multiple calorimeters surrounding the sample/s. The goal is to shoot certain materials and then analyze how they react to the exposure of the electrons. We shot titanium, which was meant to serve as a containment vessel window.

36 MATERIALS SCIENCE↗

Tunable Plasma Linearizer for Compensation of Nonlinear Energy Chirp

The removal of undesired nonlinear time-energy correlation (energy chirp) present in relativistic electron beams is crucial for many accelerator-based scientific applications, such as free-electron lasers, high-energy electron radiography, and MeV ultrafast electron microscopy. Here, we propose and demonstrate that a low-density plasma section can be used as a passive “linearizer” to significantly compensate for the nonlinear energy chirp imprinted on a beam by the curvature of the radio-frequency field in a conventional accelerator. Physically, the passage of the beam through the plasma excites a strong quasi-cosinoidal longitudinal decelerating wakefield that acts to mitigate the beam’s nonlinear energy chirp by superimposing a reverse chirp on the beam. Time-resolved phase-space measurements, combined with high-fidelity three-dimensional particle-in-cell simulations show that the longitudinal phase space of the beam core is almost completely linearized, leading to a fourfold reduction of the beam overall energy spread from 0.148% to 0.036% (FWHM).

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Time-Resolved Beam Position Measurements for the Scorpius Multipulse Linear Induction Accelerator

Beam position monitors (BPMs) provide time-resolved measurements of the current and centroid position of high-current electron beams in linear induction accelerators (LIAs). One of the types of detectors used in BPMs is the B-dot loop, which generates a signal from the EMF due to the time varying magnetic flux through the loop. If some of the boundaries of the loop are composed of thick metal walls with finite conductivity, the resulting signal must be corrected for the magnetic field diffusion into the metal. The theoretically predicted flux due to diffusion is in remarkable agreement with experimental measurements. Although accurate BPM measurements of beam current require correction of magnetic field diffusion, accurate measurement of beam position requires no correction. In this note, we present a theoretical derivation and the experimental validation of this result.

43 PARTICLE ACCELERATORS↗

Magnetic-Field Diffusion Effects in Beam Position Monitors III: Application to DARHT-II Beam Data

Beam position monitors (BPMs) provide time-resolved measurements of the current and centroid position of high-current electron beams in linear induction accelerators (LIAs). One of the types of detectors used in BPMs is the B-dot loop, which generates a signal from the EMF due to the time varying magnetic flux through the loop. If some of the boundaries of the loop are composed of thick metal walls with finite conductivity, the resulting signal must be corrected for the magnetic field diffusion into the metal. The theoretically predicted flux due to diffusion is in remarkable agreement with experimental measurements. Although accurate BPM measurements of beam current require correction of magnetic field diffusion, accurate measurement of beam position requires no correction. In this note, we present experimental validation of current and position results from a prototype detector employing finite conductivity sensing areas, based on experiments on the DARHT-II LIA.

43 PARTICLE ACCELERATORS↗

Pushing the limits of high-resolution polymer microscopy using antioxidants

High-resolution transmission electron microscopy (HRTEM) has been transformative to the field of polymer science, enabling the direct imaging of molecular structures. Although some materials have remarkable stability under electron beams, most HRTEM studies are limited by the electron dose the sample can handle. Beam damage of conjugated polymers is not yet fully understood, but it has been suggested that the diffusion of secondary reacting species may play a role. As such, we examine the effect of the addition of antioxidants to a series of solution-processable conjugated polymers as an approach to mitigating beam damage. Characterizing the effects of beam damage by calculating critical dose D c values from the decay of electron diffraction peaks shows that beam damage of conjugated polymers in the TEM can be minimized by using antioxidants at room temperature, even if the antioxidant does not alter or incorporate into polymer crystals. As a consequence, the addition of antioxidants pushes the resolution limit of polymer microscopy, enabling imaging of a 3.6Å lattice spacing in poly[(5,6-difluoro-2,1,3-benzothiadiazol-4,7-diyl)-alt-(3,3"-di(2-octyldodecyl)-2,2';5',2";5",2"-quaterthiophene-5,5"-diyl)] (PffBT4T-2OD).

36 MATERIALS SCIENCE↗

Intrabeam scattering studies with large-emittance-ratio ion beams in the Relativistic Heavy Ion Collider, and implications for the Electron-Ion Collider

The Electron-Ion Collider (EIC), to be constructed at Brookhaven National Laboratory, will collide polarized, high-energy electron beams with hadron beams, achieving peak luminosities of up to 1.0 x 10 34 cm -2 s -1 . To reach such high luminosity, the EIC will employ flat-beam collisions at the interaction point. The design transverse emittance ratio will be about 10:1 in the Hadron Storage Ring (HSR). Thanks to stochastic cooling and precise decoupling, we successfully generated and accelerated gold ion beams with a large emittance ratio of 11:1 in the Relativistic Heavy Ion Collider (RHIC). In this article, we present results of intrabeam scattering (IBS) measurements and modeling for large-emittance gold ion beams, both without and with controlled betatron coupling. To model the IBS growth, we use the formulas developed by Lebedev and Nagaitsev.

43 PARTICLE ACCELERATORS↗

Correcting Magnetic-Field Diffusion Effects in Beam Position Monitors

Beam position monitors (BPMs) provide timeresolved measurements of the current and centroid position of high-current electron beams in linear induction accelerators (LIAs). The data from some types of BPMs can be influenced by magnetic field diffusion into the surrounding metal. We derive an estimate of the correction factor from first principles, and show how it is applied in practice to nearly eliminate the effect from the data.

43 PARTICLE ACCELERATORS↗

Redesigning the Jefferson Lab Hall A beam line for high precision parity experiments

The Continuous Electron Beam Accelerator Facility (CEBAF) was built with a thermionic electron source and the three original experimental hall lines reflected this. A few years after beam delivery began a parity violation experiment was approved and two polarimeters were installed in the Hall A beam line. The beam raster system was placed after the new Compton polarimeter, before one accelerator quadrupole and four quadrupoles in the new Moller polarimeter. It was very difficult to meet experimental requirements on envelope functions and raster shape with this arrangement so a sixth quadrupole was installed downstream of the Moller polarimeter to provide an additional degree of freedome. All of the parity experiments in Hall A have been run with this still-unsatisfactory configuration. The MOLLER experiment is predicated on achieving a 2% error on a 32 ppb asymmetry. Beam line changes are required to meet the systematic error budget. This work documents the existing beam line, an interim change which can be accomplished during a annual maintenance down, and the final configuration for MOLLER and subsequent experiments.

47 OTHER INSTRUMENTATION↗

Shape evolution and growth mechanisms of 3D-printed nanowires

3D printing of nanowires using Focused Electron Beam Induced Deposition (FEBID) enables the direct-write fabrication of complex 3D objects on almost any substrate surface. The physical properties of such freestanding structures are determined by the dimensions of constituent nanowires. However, little knowledge is available about the exact shape of the nanowires, which is indispensable for calculations and simulations as well as for optimization in applications. In this study, we evaluate the thicknesses and widths of freestanding segments as a function of the inclination angles, primary electron energy, beam currents, and precursor flux. Furthermore, the cross-sectional shape, the cross-sectional area, and the evolution along the length of the wire are investigated. Basing on detailed scanning electron microscopy measurements and Monte Carlo/Finite Differences simulations, the effects that the growth parameters have on the segment growth are elucidated. Furthermore, the results shed light on the growth evolution of the structures and form the basis for future studies on the fabrication of high-precision, arbitrarily shaped nanowires.

36 MATERIALS SCIENCE↗

Learning and Controlling Silicon Dopant Transitions in Graphene Using Scanning Transmission Electron Microscopy

A machine learning approach is introduced to determine the transition dynamics of silicon atoms on a single layer of carbon atoms, when stimulated by the electron beam of a scanning transmission electron microscope (STEM). This method is data-centric, leveraging data collected on a STEM. The data samples are processed and filtered to produce symbolic representations, which is used to train a neural network to predict transition probabilities. These learned transition dynamics are then leveraged to guide a single silicon atom throughout the lattice to pre-determined target destinations. Empirical analyses are presented that demonstrate the efficacy and generality of the approach.

36 MATERIALS SCIENCE↗