Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “dynamic loading”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 793 records · Page 44

Assessing the Optical Performance Impact of Tracking Error in an Operational Concentrated Solar Power Plant Using Monte Carlo Ray-Tracing Simulation

Concentrating Solar Power (CSP) provides firm and dispatchable electricity due to its thermal storage and hybridization capabilities, which supports the decarbonization of our energy supply. Of the various CSP technologies, parabolic trough collectors are the most mature, with over 500 MW operating worldwide. The optical performance of parabolic trough systems is sensitive to tracking error, which is defined as the angular offset of a collector away from the sun position in the transversal plane. Tracking error commonly occurs due to non-continuous adjustment of the trough angle to point toward the sun, but other factors such as gravity, heating, and wind loading can also contribute to tracking error. Researchers have explored the impact of tracking error on optical performance both numerically and experimentally, but existing studies do not include measurements from operational utility-scale power plants. Tilt angle measurements of parabolic troughs at operational utility-scale power plants illustrate spatial variations in optical performance and include various sources of tracking error such as gravity, heating, and wind loading. To fully characterize wind driven loads on parabolic troughs, we are conducting a long-term field measurement campaign at the Nevada Solar One CSP plant located in Boulder City, NV, which has a nominal capacity of 72 MW and 0.5 hours of full-load storage. We record load measurements on four outer trough rows, collecting support structure bending moments, drive torque moments, dynamic accelerations of the spaceframe, mirror displacement, and tilt angles. Using the tilt measurements acquired at 20 Hz frequency, we calculate the deviation between the nominal sun position and the tracker angle. Using a Monte-Carlo ray-tracing simulation software, we assess the impact of the tracker angle deviation on optical performance throughout the diurnal cycle at various spatial locations within the CSP plant. In our view, this first-of-a-kind study will provide important guidance for future trough designs that reduce the impact of various sources of tracking error on performance.

concentrating solar power↗

Improving Frequency Stability and Minimizing Load Shedding Events by Adopting Grid-Scale Energy Storage with Grid Forming Inverters

The upward adoption trend of renewable generation not only means cleaner energy integrated into modern power grids, but also that most new generation sources are based on front-end inverter bridges, used as interfaces to most wind generation and all the solar PV. It is well known that due to their power electronics-based construction rather than rotational shafts, these sources do not provide inertia inherently, nor substantial amounts of short-circuit currents. However, stable energy such as what can be stored in energy storage systems, although interfaced via inverters, can be controlled to respond to system disturbances in a manner that emulates inertial behavior. This paper focuses on the application of such energy storage systems to augment inertia in the island of Puerto Rico. To do so, a user defined inverter model that contains grid forming capabilities and fast frequency response is modeled and integrated into the real transmission system in power flow and dynamics software. Energy storage is then connected to two selected areas so that it not only provides frequency regulation to avoid widespread load shedding events, but also other tangible benefits. The simulated cases suggest that even relatively small energy storage systems can avert load shedding events if adequately placed in the transmission network.

Grid-forming inverters, IBR, Inertia↗

Molecular dynamics simulation of vacancy and void effects on strain-induced martensitic transformations in Fe-50 at.% Ni model concentrated solid solution alloy

Strain-induced martensitic transformations can improve the strength and ductility of some face centered cubic (FCC) metals and alloys. Irradiation-induced defects such as vacancies, dislocation loops, and voids activate martensitic transformations over a wider range of mechanical loading conditions than in pristine material. Furthermore, the mechanisms underlying irradiation-enabled martensite transformations remain unclear. In this work, we use molecular dynamics simulations to study the effect of vacancies and voids on strain-induced martensitic transformations in a model concentrated solid solution alloy Fe-50 at.% Ni. It has been found that single vacancies have no resolvable effect on the transformation because they reduce the stacking fault energy by a relatively insignificant margin and do so only if the vacancy is located on the stacking fault plane. Voids, however, activate the martensite transformation through shear strain accumulation around the void due to dislocation pileup. The larger the void, the more pronounced this effect.

36 MATERIALS SCIENCE↗

Crashworthiness of recycled carbon fiber composite sinusoidal structures at dynamic rates

Fiber reinforced polymer composites are finding applications in the automotive space for structurally critical applications including crash management. The use of recycled carbon fiber reinforcement can greatly reduce carbon emissions. In this study, recycled carbon fiber composites were manufactured into a self-supporting geometry using three matrices: polyphenylene sulfide (PPS), acrylonitrile butadiene styrene (ABS), and a structural epoxy, and subsequently crushed between flat platens at dynamic rates ranging from 4.6 to 9.1 ms -1 at temperatures in a range of -40°C to 80°C. Load-displacement data was used to evaluate their specific energy absorption, crush efficiency, and steady-state crush stress. Further, the energy absorption of the ABS composites was strongly sensitive to temperature, while the PPS composites exhibited strong crush efficiency dependence with both rate and temperature. The epoxy composites exhibited stable crush behavior at dynamic crush rates but exhibited a dramatic reduction in crush efficiency relative to quasi-static tests. The results of this study indicate that recycled fiber composites can achieve very high energy absorption levels (50–80kJkg -1 at room temperature) that make them an excellent alternative to more expensive and less environmentally friendly continuous virgin fiber laminates.

42 ENGINEERING↗

Plate motion in sheared granular fault system

Plate motion near the fault gouge layer, and the elastic interplay between the gouge layer and the plate under stick-slip conditions, is key to understanding the dynamics of sheared granular fault systems. Here, a two-dimensional implementation of the combined finite-discrete element method (FDEM), which merges the finite element method (FEM) and the discrete element method (DEM), is used to explicitly simulate a sheared granular gouge fault system. In this work we focus on investigating the influence of normal load, driving shear velocity and plate stiffness on the velocities and displacements in the direction parallel to the shear direction (x-direction) measured at locations on the upper and lower plates just adjacent to the gouge. The simulations show that during slip phases the magnitudes of the measured velocities on the upper and lower plates are proportional to the normal load and may be inversely proportional to the square root of the plate's shear modulus. Whereas, the driving shear velocity does not show distinct influence on the measured velocities. Additionally, large slip velocities are generally associated with large macroscopic friction coefficient drops. For the models subjected to smaller normal loads, larger shear velocities and with stiffer shear plates, the same magnitude of slip velocity could cause a larger drop of macroscopic friction coefficient. During stick phases, the velocities of the upper and lower plates are respectively slightly greater and slightly smaller than half of the driving shear velocity and are both in the same direction of shear. The shear strain rate of the gouge is calculated from this velocity difference between the upper and lower plate during stick phases and thus the gouge effective shear modulus can be calculated. The results show that the gouge effective shear modulus increases proportionally with normal load, while the influence of shear velocity and plate stiffness on gouge effective shear modulus is minor. The simulations address the dynamics of a laboratory-scale fault gouge system and may aid in revealing the complexities of earthquake frictional dynamics.

58 GEOSCIENCES↗

Peak Load Management in Distribution Systems Using Legacy Utility Equipment and Distributed Energy Resources: Preprint

The ability to perform peak load management in distribution systems has several benefits for utilities, including reduced demand charges and improved reliability, efficiency, and utilization of the network infrastructure. This paper demonstrates the coordinated operation of an advanced distribution management system (ADMS) and a distributed energy resource management system (DERMS) to achieve peak load management using a realistic laboratory test bed. A commercial ADMS reduces the peak demand by reducing system voltages using a dynamic voltage regulation (DVR) application. A prototype DERMS—based on real-time optimal power flow—controls distributed battery energy storage systems to further reduce the feeder power. Results from the experiments conducted using a model of a real distribution feeder show that the coordinated operation of the ADMS and DERMS is effective in accomplishing peak load management.

61 RADIATION PROTECTION AND DOSIMETRY↗

The Heuristic Dynamic Programming Approach in Boost Converters

In this study, a heuristic dynamic programming controller is proposed to control a boost converter. Conventional controllers such as proportional-integral-derivative (PID) or proportional-integral (PI) are designed based on the linearized small-signal model near the operating point. Therefore, the performance of the controller during the start-up, the load change, or the input voltage variation is not optimal since the system model changes by varying the operating point. The heuristic dynamic programming controller optimally controls the boost converter by following the approximate dynamic programming. The advantage of the HDP is that the neural network-based characteristic of the proposed controller enables boost converters to easily cope with large disturbances. An HDP with a well-trained critic and action networks can perform as an optimal controller for the boost converter. To compare the effectiveness of the traditional PI-based and the HDP boost converter, the simulation results are provided.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Performance evaluation of a dynamic wall integrated with active insulation and thermal energy storage systems

Thermal energy storage systems in buildings can store cooling/heating energy during non-peak load hours or when renewable energy sources are available for later use when demanded. Using the building envelope as a thermal battery can help to shave the peak load, reduce the burden in electric grids, and enhance the occupant's thermal comfort. Sensible energy storage on wall systems such as thermally activated building systems can provide an active thermal storage strategy. However, most of the stored energy is used through passive means directed by the thermal lag, which can impede the on-demand release of the stored energy. Integrating active insulation systems with building thermal storage systems can increase the flexibility of charging and discharging time and duration. In this study, a wall system equipped with an active insulation system and thermally activated storage system was designed, and its performance on active cooling energy contribution was studied. The performances of energy storage (charging), release (discharging) of the thermal energy storage energy, and the active insulation system were studied separately and together as an integrated system. Results showed that the thermal properties of the thermal energy storage core material and the pipe spacing of both embedded pipes in the thermal energy storage and hydronic pipes used in the active insulation system affected the wall performance the most out of all the tested wall system parameters. During discharging, the heat flux into the wall was as high as 81.92 W/m 2 . This active insulation system's dynamic R-value varied between less than 1ft 2 •°F•h/BTU (0.18 m 2 •K/W) to 98% of the equally thick foam insulation's R-value.

25 ENERGY STORAGE↗

Peak Load Management in Distribution Systems Using Legacy Utility Equipment and Distributed Energy Resources

The ability to perform peak load management in distribution systems has several benefits for utilities, including reduced demand charges and improved reliability, efficiency, and utilization of the network infrastructure. This paper demonstrates the coordinated operation of an advanced distribution management system (ADMS) and a distributed energy resource management system (DERMS) to achieve peak load management using a realistic laboratory test bed. A commercial ADMS reduces the peak demand by reducing system voltages using a dynamic voltage regulation (DVR) application. A prototype DERMS-based on real-time optimal power flow-controls distributed battery energy storage systems to further reduce the feeder power. Results from the experiments conducted using a model of a real distribution feeder show that the coordinated operation of the ADMS and DERMS is effective in accomplishing peak load management.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Speed Variation Based Power Regulation Concept for Dynamic Wireless Charging

On-road wireless charging of electric vehicles (EVs) in-motion could potentially reduce range anxiety or battery size with wide-spread deployment. The planning and implementation of such systems are greatly complicated due to their susceptibility to load variation inherent to traffic flow. Here, this paper proposes a method for derisking the potential for traffic slowdowns by compensating for reduced vehicle speed and investigates how implementation may affect system performance. A load modeling case study is presented at 200kW for a mile of high-speed roadway employing speed-based power regulation with results indicating average power usage and maximum car hosting capability can be reduced by 20% and increased by 30% respectively. An 85kHz power electronics model is developed based on designs and prototypes for an 11kW, 190m airgap static system and a 200kW dynamic wireless track. The simulation is validated in the 11kW experimental prototype and modified for 200kW operation to compare with simulated performance. Sensitivity studies are performed in MATLAB/Simulink to evaluate how parameters influence system performance and confirm the capability to reduce output power and maintain efficiency at 11 and 200kW. The static 11kW experimental system operates at 93.6% efficiency and multiple options exist to reduce power while maintaining efficiency greater than 90%. The capability to dynamically modify power output from WPT coils, in an experimentally validated simulation, enables techniques to significantly mitigate load variability due to reductions in vehicle speed.

42 ENGINEERING↗

Predicted Heat Flux Performance of Actively Cooled Tungsten-Armored Graphitic Foam Monoblocks

Tungsten (W)–armored graphitic foam monoblocks were developed for applications requiring high-Z plasma-facing material in long-pulse fusion experiments and ultimately deuterium-tritium fusion reactors. The monoblocks are an integrated material system combining the advantages of a chemical vapor deposited (CVD) W coating with a high-conductivity graphitic foam. The W is a high-melting-point, high-Z material with low tritium retention. The graphitic foam coupled to a swirl tube serves as a high-thermal-conductivity heat sink that cannot melt, although it can sublime at much higher temperatures than copper melts. Together, they comprise a robust plasma-facing component (PFC) weighing roughly 5% of an all-W component or 17% of a traditional W-coated copper heat sink.A single-channel mock-up consisting of four graphitic foam monoblocks equipped with a water-cooled swirl tube was fabricated for eventual testing in the 60-kW, EB-60, rastered electron beam at the Applied Research Laboratory of The Pennsylvania State University. Two monoblocks have a thin 50-μm-thick coating of pure W chemically vapor deposited over NbC and pure Nb interlayers. Two others have a 2-mm-thick pure W coating CVD on graphitic monoblocks using the same interlayers. The mock-up will be cooled with available 10 m/s, 0.7 MPa water with a 22°C inlet temperature and subjected to varying uniform heat loads up to 20 MW/m 2 . It is equipped with type-K thermocouples at various depths, and calibrated infrared thermography and spot pyrometry will be used to characterize the heated surface. Real-time water calorimetry will be used to ascertain the absorbed steady-state power and infer the heat flux during testing. Since testing cannot be done under prototypic divertor flow conditions, it is necessary to predict the thermal response of this novel PFC system and investigate the power sharing between radiation and convection at divertor heat flux levels and its inherent ability to avoid critical heat flux. Results are reported for predictions obtained from computational fluid dynamics models up to 30 MW/m 2 of steady-state uniform heat flux. Leading-edge heat loads of 30 MW/m 2 on a 2-mm-wide side strip were also investigated to ascertain if coating delamination is likely.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Dynamic Adaptive Relaying for Distribution Grids with High Inverter-Based Generation

The penetration of distributed energy resources (DERs) in distribution systems is rapidly increasing. This can lead to large variations in the operating load and the fault current seen by a relay, which can impact the reliability of overcurrent protection. Adaptive overcurrent relaying (AOCR) can address this concern by enabling the relay to adjust its pickup settings based on the system operating conditions. This paper presents a novel dynamic AOCR approach that allows the relays to locally estimate the pickup settings and dynamically modify them. The approach is based on a two-stage estimation algorithm that uses local measurements and system information to estimate the worst-case fault current and the relay pickup settings. The relay pickup settings are then dynamically modified based on the estimated fault current. The performance of the proposed approach is evaluated on multiple configurations of the EPRI J1 feeder and the IEEE 13-bus system. The results show that the proposed approach can effectively improve the reliability of overcurrent protection in distribution systems with DERs.

adaptive overcurrent protection↗

Stochastic Adaptive Droop Control in Frequency Regulation of Power Systems With Intermittent Generators

Modern power systems (MPSs), including microgrids (MGs), are increasingly incorporating multiple renewable energy sources (RESs) such as wind and solar power, as well as battery storage and controllable loads. While environmentally beneficial, these sources pose challenges for control and management due to their intermittent and stochastic nature, especially in maintaining frequency stability with multiple interconnected generators of varying capacities. Traditional droop control methods are effective in systems with generators that are dispatchable and have fixed generation capacities, but they fall short when applied to systems with RESs, where generation capacities are dynamic and affected by unpredictable environmental conditions. To address these challenges, this paper introduces a novel stochastic adaptive droop control (SADC) method for load frequency control (LFC). The proposed method adapts droop coefficients in real time, based on the measured stochastic data of power generation capacities, enabling more effective frequency regulation in systems with variable and intermittent power generation. Unlike traditional adaptive control methods, which assume constant or slowly-varying system parameters, this approach accounts for stochastic processes by modeling them as Markov chains, enabling robust performance under highly dynamic and unpredictable conditions. The key contributions of this work include the development of real-time droop coefficient adaptation algorithms, derivation of their stability and convergence properties, and the demonstration of the advantages of the method through simulations. Case studies highlight the improved performance of frequency regulation, particularly in addressing the impact of stochastic weather conditions and the benefits of reducing dependence on battery reserves in dealing with intermittency of RESs. Finally, this paper provides a comprehensive analysis of the theoretical foundations of the method, as well as practical implementation insights for future power systems with high penetration of RESs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Dynamic Temporal Graph Sequence Data for Resilience-Oriented Distribution Network Reconfiguration

This dataset comprises temporal dynamic graph sequences generated from power grid simulations focused on grid reconfiguration to enhance resilience. The simulations model failure propagation under varying conditions, with nodes assigned distinct failure probabilities. For each time step, the dataset captures the evolution of node states (functional or failed) and features critical to grid operations, such as pv_output, load_profile, load_dispatch, dg_output, loss, and voltage. Node types include sources, normal loads, and nodes with specific equipment like PVs, micro turbines, or shunt capacitors. The dataset is structured to support the training of dynamic graph neural networks, facilitating research on node feature prediction and edge dynamics under failure scenarios. Three distinct configurations are included, providing a robust foundation for modeling power grid resilience.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Data Driven Approach to Dislocation-Based Plasticity Models of Face-Centered Cubic Metals

Dislocation dynamics controls plastic deformation, mechanical strength, and failure of crystalline materials. It also governs fatigue resistance under cyclic loading, creep resistance at elevated-temperature, and radiation resistance for reactor applications. There is a compelling need for understanding fundamental dislocation mechanisms for deformation because virtually all structural metals used in energy systems are fabricated to desired forms and shapes by deformation processes. To date, the most outstanding problem in a physics-based multiscale model of crystal plasticity is the lack of quantitative connections between continuum plasticity (CP) models with the lower scale dislocation models. As a result, existing CP models used in engineering applications are still phenomenological, while evidence continues to mount that they can make inaccurate predictions under realistically complex scenarios. This project takes advantage of the recent advances in high-performance discrete dislocation dynamics (DDD) simulations and data science approaches to establish the first fully connected multiscale plasticity model for pure face-centered cubic (FCC) single crystals.

36 MATERIALS SCIENCE↗

Applying Dynamic Strain on Thin Oxide Films Immobilized on a Pseudoelastic Nickel-Titanium Alloy

Direct alteration of materials structure/function through strain is a burgeoning area of research that has allowed for novel properties of materials to emerge. Tuning materials structure can be achieved by controlling an external force imposed on materials and inducing stress-strain responses (i.e., applying dynamic strain). Electroactive thin films are typically deposited on shape or volume tunable elastic substrates, where mechanical loading (i.e. compression or tension) can affect films structure and function through imposed strain. Here we summarize methods for straining n-type doped titanium dioxide (TiO2) films prepared by a thermal treatment of a pseudo-elastic nickel-titanium alloy. The main purpose of the described methods is to study how strain affects electrocatalytic activities of metal oxide, specifically hydrogen evolution and oxygen evolution reactions. The same system can be adapted to study the effect of strain more broadly. Strain engineering can be applied for optimization of a material function, as well as for design of adjustable, multifunctional (photo)electrocatalytic materials under external stress control.

92 SC - Basic Energy Sciences (BES) (SC-22)↗

Assessment of Low-Altitude Atmospheric Turbulence Models for Aircraft Aeroelasticity

We investigate the dynamic aeroelastic response of large but slow aircraft in low-altitude atmospheric turbulence. To this end, three turbulence models of increasing fidelity, namely, the one-dimensional von Kármán model, the two-dimensional Kaimal model and full three-dimensional wind fields extracted from large-eddy simulations (LES) are used to simulate ambient turbulence near the ground. Load calculations and flight trajectory predictions are conducted for a representative high-aspect-ratio wing aircraft, using a fully coupled nonlinear flight dynamics/aeroelastic model, when it operates in background atmospheric turbulence generated by the aforementioned models. Comparison of load envelopes and spectral content, on vehicles of varying flexibility, shows strong dependency between the selected turbulence model and aircraft aeroelastic response (e.g. 58% difference in the predicted magnitude of the wing root bending moment between LES and von Kármán models). This is mainly due to the presence of large flow structures at low altitudes that have comparable dimensions to the vehicle, and which despite the relatively small wind speeds within the Earth boundary layer, result in overall high load events for slow-moving vehicles. Results show that one-dimensional models that do not capture those effects provide fairly non-conservative load estimates and are unsuitable for very flexible airframe design.

atmospheric turbulence↗

Characterizing Output Bottlenecks of a Production Supercomputer: Analysis and Implications

This article studies the I/O write behaviors of the Titan supercomputer and its Lustre parallel file stores under production load. The results can inform the design, deployment, and configuration of file systems along with the design of I/O software in the application, operating system, and adaptive I/O libraries.We propose a statistical benchmarking methodology to measure write performance across I/O configurations, hardware settings, and system conditions. Moreover, we introduce two relative measures to quantify the write-performance behaviors of hardware components under production load. In addition to designing experiments and benchmarking on Titan, we verify the experimental results on one real application and one real application I/O kernel, XGC and HACC IO, respectively. These two are representative and widely used to address the typical I/O behaviors of applications.In summary, we find that Titan’s I/O system is variable across the machine at fine time scales. This variability has two major implications. First, stragglers lessen the benefit of coupled I/O parallelism (striping). Peak median output bandwidths are obtained with parallel writes to many independent files, with no striping or write sharing of files across clients (compute nodes). I/O parallelism is most effective when the application—or its I/O libraries—distributes the I/O load so that each target stores files for multiple clients and each client writes files on multiple targets in a balanced way with minimal contention. Second, our results suggest that the potential benefit of dynamic adaptation is limited. In particular, it is not fruitful to attempt to identify “good locations” in the machine or in the file system: component performance is driven by transient load conditions and past performance is not a useful predictor of future performance. For example, we do not observe diurnal load patterns that are predictable.

97 MATHEMATICS AND COMPUTING↗