Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “digital image correlation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 793 records · Page 44

Design of optimal correlation filters for hybrid vision systems

Research is underway at the NASA Johnson Space Center on the development of vision systems that recognize objects and estimate their position by processing their images. This is a crucial task in many space applications such as autonomous landing on Mars sites, satellite inspection and repair, and docking of space shuttle and space station. Currently available algorithms and hardware are too slow to be suitable for these tasks. Electronic digital hardware exhibits superior performance in computing and control; however, they take too much time to carry out important signal processing operations such as Fourier transformation of image data and calculation of correlation between two images. Fortunately, because of the inherent parallelism, optical devices can carry out these operations very fast, although they are not quite suitable for computation and control type operations. Hence, investigations are currently being conducted on the development of hybrid vision systems that utilize both optical techniques and digital processing jointly to carry out the object recognition tasks in real time. Algorithms for the design of optimal filters for use in hybrid vision systems were developed. Specifically, an algorithm was developed for the design of real-valued frequency plane correlation filters. Furthermore, research was also conducted on designing correlation filters optimal in the sense of providing maximum signal-to-nose ratio when noise is present in the detectors in the correlation plane. Algorithms were developed for the design of different types of optimal filters: complex filters, real-value filters, phase-only filters, ternary-valued filters, coupled filters. This report presents some of these algorithms in detail along with their derivations.

Rajan, Periasamy K.↗

Sea ice tracking by nested correlations

Spatial differences in sea ice displacement affect ice stress, ice production, and the mass balance of the ice cover. Concepts about the spatial structure of this field have been undernourished because of a paucity of data with high spatial detail and because of the tedium of extracting such measurements from images manually. A method is described that measures displacements from synthetic aperture radar digital imagery with fine spatial resolution, and does so fully automatically. Many small areas of ice common to two images are identified by correlating the two images. The strategy is to acquire a crude displacement field first from highly averaged images, and to refine this field with images of successively higher resolution. The median discrepancy between automatically and manually measured displacements is three pixels (0.075 km). The algorithm operates successfully on compact ice with large floes and modest rotation rates; it is believed it will prove applicable to most of the arctic ice cover throughout the year.

Fily, Michael↗

Breast Cancer Risk Estimation Using Parenchymal Texture Analysis in Digital Breast Tomosynthesis

Mammographic parenchymal texture has been shown to correlate with genetic markers of developing breast cancer. Digital breast tomosynthesis (DBT) is a novel x-ray imaging technique in which tomographic images of the breast are reconstructed from multiple source projections acquired at different angles of the x-ray tube. Compared to digital mammography (DM), DBT eliminates breast tissue overlap, offering superior parenchymal tissue visualization. We hypothesize that texture analysis in DBT could potentially provide a better assessment of parenchymal texture and ultimately result in more accurate assessment of breast cancer risk. As a first step towards validating this hypothesis, we investigated the association between DBT parenchymal texture and breast percent density (PD), a known breast cancer risk factor, and compared it to DM. Bilateral DBT and DM images from 71 women participating in a breast cancer screening trial were analyzed. Filtered-backprojection was used to reconstruct DBT tomographic planes in 1 mm increments with 0.22 mm in-plane resolution. Corresponding DM images were acquired at 0.1 mm pixel resolution. Retroareolar regions of interest (ROIs) equivalent to 2.5 cm{sup 3} were segmented from the DBT images and corresponding 2.5 cm{sup 2} ROIs were segmented from the DM images. Breast PD was mammographically estimated using the Cumulus scale. Overall, DBT texture features demonstrated a stronger correlation than DM to PD. The Pearson correlation coefficients for DBT were r = 0.40 (p<0.001) for contrast and r = -0.52 (p<0.001) for homogeneity; the corresponding DM correlations were r = 0.26 (p = 0.002) and r = -0.33 (p<0.001). Multiple linear regression of the texture features versus breast PD also demonstrated significantly stronger associations in DBT (R{sup 2} = 0.39) compared to DM (R{sup 2} = 0.33). We attribute these observations to the superior parenchymal tissue visualization in DBT. Our study is the first to perform DBT texture analysis in a screening population of women, showing that DBT could potentially provide better breast cancer risk assessment in the future.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Characteristic of a Digital Correlation Radiometer Back-End with Finite Wordlength

Performance of a radiometer DBE is analyzed. The particular design corresponds to the DBE of the airborne Hurricane Imaging Radiometer. A computer simulator is developed to analyze effect of input power on various DBE output products. 2nd moment non-linearity is found to be negligible in the expected input signal dynamic range. Observed scaling between I and Q channels and the scaling among cross-correlation signals are verified by the simulator. Kurtosis sensitivity can be improved by lowering the input power - predicted by the simulator and verified in the lab.

radiometry↗

The fractal dimension of cell membrane correlates with its capacitance: A new fractal single-shell model

The scale-invariant property of the cytoplasmic membrane of biological cells is examined by applying the Minkowski-Bouligand method to digitized scanning electron microscopy images of the cell surface. The membrane is found to exhibit fractal behavior, and the derived fractal dimension gives a good description of its morphological complexity. Furthermore, we found that this fractal dimension correlates well with the specific membrane dielectric capacitance derived from the electrorotation measurements. Based on these findings, we propose a new fractal single-shell model to describe the dielectrics of mammalian cells, and compare it with the conventional single-shell model (SSM). We found that while both models fit with experimental data well, the new model is able to eliminate the discrepancy between the measured dielectric property of cells and that predicted by the SSM.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

New surface characterization tools for alumina based refractory material exposed to cavitation - Image analysis and pattern recognition approach

Highlights: • Surface degradation was monitored via mass loss measurement. • Observation of surface damage destruction was done using image analysis. • Shape parameters of surface defects change during cavitation. • Shape parameters changes are correlated to mass loss measurements. - Abstract: The aim of this study was to examine the influence of cavitation erosion on the morphology of defects formed on the surfaces of alumina-based materials. The alumina-based samples were exposed to cavitation erosion for 42 min. The damages that occurred were monitored at predefined time intervals by measuring the mass loss and observing the sample surfaces. Digital images of surfaces were processed using an image analysis software package to define morphological characteristics of the damages occurred. The calculated morphological parameters were subjected to analysis by pattern recognition techniques to correlate the appearance of particular morphological characteristics with the behavior of the material during cavitation erosion. The newly established method in describing cavitation erosion which uses pattern recognition approach for treatments of morphological parameters calculated for damages by image analysis tools gave the results efficient for material characterization as the traditional one.

36 MATERIALS SCIENCE↗

A Preliminary Analysis of LANDSAT-4 Thematic Mapper Radiometric Performance

Analysis was performed to characterize the radiometry of three Thematic Mapper (TM) digital products of a scene of Arkansas. The three digital products examined were the NASA raw (BT) product, the radiometrically corrected (AT) product and the radiometrically and geometrically corrected (PT) product. The frequency distribution of the digital data; the statistical correlation between the bands; and the variability between the detectors within a band were examined on a series of image subsets from the full scene. The results are presented from one 1024 x 1024 pixel subset of Realfoot Lake, Tennessee which displayed a representative range of ground conditions and cover types occurring within the full frame image. Bands 1, 2 and 5 of the sample area are presented. The subsets were extracted from the three digital data products to cover the same geographic area. This analysis provides the first step towards a full appraisal of the TM radiometry being performed as part of the ESA/CEC contribution to the NASA/LIDQA program.

Justice, C.↗

Evaluating LANDSAT-4 MSS and TM data

Interband line pixel misregistrations were determined for the four MSS bands of the Mistassini, Ontario scene and multitemporal registration of LANDSAT-4 products were tested for two different geocoded scenes. Line and pixel misregistrations are tabulated as determined by the manual ground control points and the digital band to band correlation techniques. A method was developed for determining the spectral information content of TM images for forestry applications.

Strome, W. M.↗

Symmetric Phase Only Filtering for Improved DPIV Data Processing

The standard approach in Digital Particle Image Velocimetry (DPIV) data processing is to use Fast Fourier Transforms to obtain the cross-correlation of two single exposure subregions, where the location of the cross-correlation peak is representative of the most probable particle displacement across the subregion. This standard DPIV processing technique is analogous to Matched Spatial Filtering, a technique commonly used in optical correlators to perform the crosscorrelation operation. Phase only filtering is a well known variation of Matched Spatial Filtering, which when used to process DPIV image data yields correlation peaks which are narrower and up to an order of magnitude larger than those obtained using traditional DPIV processing. In addition to possessing desirable correlation plane features, phase only filters also provide superior performance in the presence of DC noise in the correlation subregion. When DPIV image subregions contaminated with surface flare light or high background noise levels are processed using phase only filters, the correlation peak pertaining only to the particle displacement is readily detected above any signal stemming from the DC objects. Tedious image masking or background image subtraction are not required. Both theoretical and experimental analyses of the signal-to-noise ratio performance of the filter functions are presented. In addition, a new Symmetric Phase Only Filtering (SPOF) technique, which is a variation on the traditional phase only filtering technique, is described and demonstrated. The SPOF technique exceeds the performance of the traditionally accepted phase only filtering techniques and is easily implemented in standard DPIV FFT based correlation processing with no significant computational performance penalty. An "Automatic" SPOF algorithm is presented which determines when the SPOF is able to provide better signal to noise results than traditional PIV processing. The SPOF based optical correlation processing approach is presented as a new paradigm for more robust cross-correlation processing of low signal-to-noise ratio DPIV image data."

Wernet, Mark P.↗

Autonomous planetary landing guidance by optical correlation

We describe our planned use of optical correlation in landmark navigation associated with planetary landing. Standard correlation provides 'pointing-to' information, giving the vector to the landmark from the spacecraft in the spacecraft frame. The synthetic estimation filter (SEF) provides 'pointing-from' information, estimating the vector from the landmark to the spacecraft. Digital and optical SEFs were constructed and compared using a Martian-like 3D modelboard to provide test images. The digital SEF worked reasonably well, but the optical SEF did not perform as expected. The optical SEF was implemented with a liquid crystal television (LCTV) correlator that had been used successfully in previous SEF experiments using a spacecraft model. The results suggest the SLM model for the LCTV needs further refinements. Both the digital and optical filter provided good pointing-to results. We did not plot the correlation surface for the digital SEF response, and though it is less sharp than the POF, it had only a one-pixel variation in the peak location. Surface plots for the conventional optical phase-only filter produced a correlation peak that was sharp enough to be located within two pixels.

Knopp, Jerome↗

Markerless tracking of small lung tumors for stereotactic radiotherapy

Purpose: (1) To validate retrospective markerless tracking software for small lung tumors by comparing tracked motion in 4-dimensional planning computed tomography (4DCT) derived kV projection images and known tumor motion in the same 4DCT. (2) To evaluate variability of tumor motion using kV projection images from cone-beam computed tomography (CBCT) scans acquired on different days. Methods: Nonclinical tumor tracking software (TTS) used a normalized cross correlation algorithm to track the tumor on enhanced kV projection images (e.g., from a CBCT scan). The reference dataset consisted of digitally reconstructed radiographs (DRRs) from one phase of a planning 4DCT. TTS matches two in-plane coordinates and obtains the out-of-plane coordinate by triangulating with match results from other projections. (1) To validate TTS, tracking results were compared with known 4DCT tumor motion for two patients (A and B). Projection images (1 image/1°) were digitally reconstructed for each 4DCT phase. From these, kV projection series were composed simulating full breathing cycles every 20° of gantry rotation [breathing period = 20°/(6°/s) = 3.33 s]. Reference templates were 360 “tumor enhanced” DRRs from the 4DCT expiration phase. TTS-derived tumor motion was compared to known tumor motion on 4DCT. (2) For five patients, TTS-assessed motion during clinical CBCT acquisition was compared with motion on the planning 4DCT, and the motion component in the Y (cranio–caudal)-direction was compared with the motion of an external marker box (RPM, real-time position management). Results: (1) Validation results: TTS for case A (tumor 6.2 cm{sup 3}, 32 mm axial diameter) over 360° showed mean motion X (medial–lateral) = 3.4, Y = 11.5, and Z (ventral–dorsal) = 4.9 mm (1 SD < 1.0 mm). Corresponding 4DCT motion was X = 3.1, Y = 11.3, and Z = 5.1 mm. Correlation coefficients between TTS tumor motion and displacement of the tumor’s center of mass (CoM) on 4DCT were 0.64, 0.96, and 0.82 (X, Y, and Z, respectively). For case B (4.1 cm{sup 3}, 20 mm diameter), due to temporarily decreased tumor visibility preventing TTS from resolving the tumor, robust tracking data were only available between angles 300°–40° and 120°–220°. Mean motion according to TTS was X = 2.0, Y = 7.7, and Z = 8.2 mm (1 SD < 0.9 mm). Tumor motion on 4DCT was X = 1.8, Y = 7.6, and Z = 9.5 mm and correlation coefficients between TTS motion and CoM displacement were 0.59, 0.95, and 0.93 (X, Y, and Z, respectively). (2) Clinical results: TTS revealed a mean intrafraction variation in tumor motion in Y-direction of >2.0 mm (1 SD) in four of five patients. In addition, clinical tumor motion amplitude differed from that seen on planning 4DCT. Internal and external structures that create abrupt density change (e.g., table-top edge, interface between lung/mediastinum and lung/heart) were observed to prevent 360° tracking of the tumor. Correlation coefficients between TTS motion in the Y-direction and the RPM signal (22 observations) ranged from 0.78 to 0.96. In 2D, 241 TTS matches at end-inspiration and end-expiration were visually validated: mean difference was 0.8 mm (SD = 0.7) for both. Conclusions: TTS can track small lung tumors if these are visible in kV projections. A 4DCT dataset can be used to validate kV tracking of moving targets. TTS and 4DCT displacement agreed to within 2 mm. TTS and RPM motion were closely associated but tumor motion during CBCT can vary from the planning 4DCT.

60 APPLIED LIFE SCIENCES↗

In situ high-temperature 3D imaging of the damage evolution in a SiC nuclear fuel cladding material

Silicon carbide (SiC)-based nuclear fission fuel rod cladding has been considered as one of the possible designs for accident tolerant fuels. It is in the form of a SiC fibre reinforced SiC matrix composite tube (SiC f -SiC m ) with monolithic SiC outer and/or inner coating layers. This study focuses on the deformation and fracture processes in this material using in situ X-ray micro-computed tomography (XCT) at room temperature (RT) and 1200 °C in an inert gas environment in a C-ring compression loading configuration. Prior to testing, local properties and residual stresses were characterised using nanoindentation and Raman spectroscopy since they can impact the mechanical behaviour of the material. The 3D strain distribution, crack formation and propagation processes including the toughening mechanisms (e.g., crack deflection, micro-cracking, crack bridging and bifurcation) are investigated in the coating and underlying composites at RT and 1200 °C. There is no particular sequence which toughening mechanism occurs first – this is very different from the conventional toughening theory in ceramic-matrix composites under uniaxial tension loading. Indeed, no evidence of fibre pull-out or fibre fracture was observed in this SiC f -SiC m nuclear cladding material in the current C-ring compression configuration. The correlation between local measurements and bulk mechanical behaviour are discussed.

3D imaging↗

Modified-signed-digit optical computing by using fan-out elements

We present a novel three-step modified-signed-digit optical computing system based on the disrete correlation of space-coded input matrices that are multiply-imaged by using optical fan-out elements. The advantages of our method over other approaches include a larger throughput, more flexible operation, and an easier optical implementation.

Zhou, Shaomin↗

Martian lineaments from Mariner 6 and 7 images

Mariner 6 and 7 images are used to investigate the nature and importance of linear surface trends on Mars. Cross correlations of frequency-azimuth distributions of linear trends from different Mariner frames indicate that lineations not recognized as topographic features have a component of artifacts, probably introduced during digital reconstruction of the images. Consequently, topographic and nontopographic lineations should be treated separately prior to interpretation of the data. Similar statistical tests may aid in the analysis of surface trends from future satellites and space probes.

Schultz, P. H.↗

Correlation of the deply technique with the ultrasonic imaging of impact damage in graphite/epoxy composites

A quantitative ultrasonic technique for the nondestructive assessment of impact damage is described. The method, which involves digitizing the entire backscattered ultrasonic wave from a sample, was applied to two test panels removed from a 16-ply graphite/epoxy laminate and impacted with an aluminum ball fired at a velocity of 150 ft/sec. The results of the ultrasonic NDE were compared with the results obtained using the destructive deply technique of Freeman (1984). The NDE method provides through-the-thickness information on damage and only requires access to a single side of the material, while the deply technique gives exact information on the actual damage. Good quantitative agreement between the two techniques was obtained.

Smith, B. T.↗

Geologic analyses of LANDSAT-1 multispectral imagery of a possible power plant site employing digital and analog image processing

A site in the Great Valley subsection of the Valley and Ridge physiographic province in eastern Pennsylvania was studied to evaluate the use of digital and analog image processing for geologic investigations. Ground truth at the site was obtained by a field mapping program, a subsurface exploration investigation and a review of available published and unpublished literature. Remote sensing data were analyzed using standard manual techniques. LANDSAT-1 imagery was analyzed using digital image processing employing the multispectral Image 100 system and using analog color processing employing the VP-8 image analyzer. This study deals primarily with linears identified employing image processing and correlation of these linears with known structural features and with linears identified manual interpretation; and the identification of rock outcrops in areas of extensive vegetative cover employing image processing. The results of this study indicate that image processing can be a cost-effective tool for evaluating geologic and linear features for regional studies encompassing large areas such as for power plant siting. Digital image processing can be an effective tool for identifying rock outcrops in areas of heavy vegetative cover.

Lovegreen, J. R.↗

Digital image analysis to quantify carbide networks in ultrahigh carbon steels

A method has been developed and demonstrated to quantify the degree of carbide network connectivity in ultrahigh carbon steels through digital image processing and analysis of experimental micrographs. It was shown that the network connectivity and carbon content can be correlated to toughness for various ultrahigh carbon steel specimens. The image analysis approach first involved segmenting the carbide network and pearlite matrix into binary contrast representations via a grayscale intensity thresholding operation. Next, the carbide network pixels were skeletonized and parceled into braches and nodes, allowing the determination of a connectivity index for the carbide network. Intermediate image processing steps to remove noise and fill voids in the network are also detailed. The connectivity indexes of scanning electron micrographs were consistent in both secondary and backscattered electron imaging modes, as well as across two different (50 × and 100 ×) magnifications. Results from ultrahigh carbon steels reported here along with other results from the literature generally showed lower connectivity indexes correlated with higher Charpy impact energy (toughness). A deviation from this trend was observed at higher connectivity indexes, consistent with a percolation threshold for crack propagation across the carbide network. - Highlights: • A method for carbide network analysis in steels is proposed and demonstrated. • ImageJ method extracts a network connectivity index from micrographs. • Connectivity index consistent in different imaging conditions and magnifications. • Impact energy may plateau when a critical network connectivity is exceeded.

36 MATERIALS SCIENCE↗