Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “detector response”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 793 records · Page 44

Physical dosimetric evaluations in the Apollo 16 microbial response experiment

Texts of high-energy multicharged particle, ultraviolet light, and galactic irradiation fluxes on exposed biological specimens aboard Apollo 16 are described. Passive nuclear track detectors, passive dosimeters, and thermoluminescent dosimeters, respectively, were used for the measurements. Biological phenomena studied ranged from lipolytic alpha toxin production in Bacillus thuringiensis to animal tissue invasion (of human hair by Trichophyton terrestre). Fluxes observed were lower than those recorded by detectors located in the Biostack and in the passive personnel dosimeters worn by the astronauts, suggesting a greater average shielding in the latter two environments.

Taylor, G. R.↗

The detection of X rays from Jupiter

X rays in the energy band 0.2-3.0 keV have been detected coming from both polar regions of Jupiter. The observations were made in 1979 and 1981 by using the imaging proportional counter and high resolution imaging detectors on the Einstein X-ray astronomy satellite. The measured flux density of approximately 0.0006/sq cm-sec at earth corresponds to an X ray luminosity of approximately 4 x 10 to the 9th W in the 0.2- to 3.0-keV energy band. The energy spectrum of the X rays is extremely soft and can be characterized by a power law with an exponent of approximately 2.3. Detector energy resolution is insufficient to distinguish a soft line spectrum from a continuum. However, the shape of the response and the observed X ray power indicate that the source of this auroral emission is not electron bremsstrahlung as on the earth, but is most probably line emission from O and S ions with energies between 0.03 and 4.0 MeV/nucleon precipitating from the outer boundary of the Io plasma torus at L approximately 8.

Metzger, A. E.↗

Differential imaging system

In this study, a technique which enhances image contrast using differentials of radiances being measured from successively overlapping footprints is discussed. One of the immediate advantages of this approach is to improve spatial resolution when the practical size limitation of detectors is reached. When diffraction is considered, radiometric accuracy at the higher spatial frequencies is decreased even though edge response (boundary crossing sharpness) will improve. For instance, an imager system based on this principle could have a primary aperture no larger than 30 cm diameter yet be capable of resolving a ground footprint as small as 2 m from a 780 km altitude.

Kim, Hongsuk H.↗

Infrared-fiber-optic fire sensor developments - Role of measurement uncertainty in evaluation of background limited range

Fire-detector systems based on distributed infrared fiber-sensors have been investigated for potential applications in the aerospace industry. Responsivities to blackbody and flame radiations were measured with various design configurations of an infrared fiber-optic sensor. Signal processing techniques were also investigated, and the results show significant differences in the fire-sensor performance depending on the design configuration. Measurement uncertainties were used to determine the background-limited ranges for the various fire-sensor concepts, and the probability of producing false alarms caused by fluctuations in the background signals were determined using extreme probability theory. The results of the research show that infrared fiber-optic fire sensors are feasible for application on manned spacecraft; however, additional development work will be required to eliminate false alarms caused by high temperature objects such as incandescent lamps.

Tapphorn, Ralph M.↗

Modelling the Soft X-Ray and EUV Emission in Classical Novae: EUVE and ROSAT Observations of V1974 Cygni

We have conducted an extensive analysis of the observability of Classical Novae with the EUVE Lex/B and Al/Ti/C detectors. Predicted count rates have been computed using optically thin, isothermal plasma models for solar and metal-rich compositions, and hot ONeMg white dwarf model atmospheres. We find EUVE to be quite sensitive to both the EUV and soft X-ray emission emitted by the underlying hot white dwarf during novae outbursts, except for the coolest temperatures with very high intervening hydrogen column density. These results are used to interpret the emission detected during the EUVE all-sky survey of Nova Cygni 1992 (approx. = V1974 Cyg), 279-290 days after visual maximum. We find the best fit to the observed emission from V1974 Cyg arises from a hot ONeMg white dwarf with surface temperature approx. 4 x l0(exp 5) K and a mas of approx. 1.2 solar mass, and derive an interstellar hydrogen column density of approx. 3 x 10(exp 21)/sq cm. Virtually all this emission arises from supersoft X-rays rather than the EUV. We also report the detection of V1974 Cyg with the EUVE Deep Survey detector at 549 days after visual maximum. This observation is compatible with the above properties, indicating that the mechanism responsible for the soft X-ray emission, connected with the underlying white dwarf, had not yet entirely turned off. We also present analysis of a ROSAT PSPC observation which is contemporaneous with the EUVE survey observations; this independently confirms the high column density we derived from the EUVE survey observation. Light curves for the EUVE and ROSAT observations are presented. Statistical tests for variability show that all of these observations are indeed highly variable over various time scales. The EUVE survey data shows one day variations, the EUVE DS data show approx. 30 minute fluctuations, while the ROSAT data vary rapidly on time scales of seconds. The EUVE data shows no periodic variability on any time scale. The implications of the rapid variability are briefly discussed.

Stringfellow, Guy S.↗

A new method for internal calibration of nuclear track detectors

A new technique is proposed for an internal calibration of a two-layer detector assembly. Spatially coincident pairs of conical tracks on one surface and overetched tracks on the adjacent surface are selected for measurement. Both the etch rate ratio and the particle range can be obtained from the minor and major diameters of the elliptical track and the radii of the circular tracks for two etching steps. This technique was applied to CR-39 detectors exposed to fast neutrons and those flown on a high altitude balloon in order to evaluate the proton response. An improvement by using multi-step etching was also carried out. It was found that not only a single set of the etch rate ratio and the range but also the response curve could be estimated in an extended region by analyzing combined growth curves.

NASA Discipline Radiation Health↗

AWG Filter for Wavelength Interrogator

A wavelength interrogator is coupled to a circulator which couples optical energy from a broadband source to an optical fiber having a plurality of sensors, each sensor reflecting optical energy at a unique wavelength and directing the reflected optical energy to an AWG. The AWG has a detector coupled to each output, and the reflected optical energy from each grating is coupled to the skirt edge response of the AWG such that the adjacent channel responses form a complementary pair response. The complementary pair response is used to convert an AWG skirt response to a wavelength.

Black, Richard J.↗

Optical Measurement of Mass Flow of a Two-Phase Fluid

An optoelectronic system utilizes wavelength-dependent scattering of light for measuring the density and mass flow of a two-phase fluid in a pipe. The apparatus was invented for original use in measuring the mass flow of a two-phase cryogenic fluid (e.g., liquid hydrogen containing bubbles of hydrogen gas), but underlying principles of operation can readily be adapted to non-cryogenic two-phase fluids. The system (see figure) includes a laser module, which contains two or more laser diodes, each operating at a different wavelength. The laser module also contains beam splitters that combine the beams at the various wavelengths so as to produce two output beams, each containing all of the wavelengths. One of the multiwavelength output beams is sent, via a multimode fiberoptic cable, to a transmitting optical coupler. The other multiwavelength output beam is sent, via another multimode fiber-optic cable, to a reference detector module, wherein fiber-optic splitters split the light into several multiwavelength beams, each going to a photodiode having a spectral response that is known and that differs from the spectral responses of the other photodiodes. The outputs of these photodiodes are digitized and fed to a processor, which executes an algorithm that utilizes the known spectral responses to convert the photodiode outputs to obtain reference laser-power levels for the various wavelengths. The transmitting optical coupler is mounted in (and sealed to) a hole in the pipe and is oriented at a slant with respect to the axis of the pipe. The transmitting optical coupler contains a collimating lens and a cylindrical lens that form the light emerging from the end of the fiber-optic cable into a fan-shaped beam in a meridional plane of the pipe. Receiving optical couplers similar to the transmitting optical couplers are mounted in the same meridional plane at various longitudinal positions on the opposite side of the pipe, approximately facing the transmitting optical coupler along the same slant. Light collected by each receiving optical coupler is sent, via a multimode fiber-optic cable, to a detector module similar to the reference detector module. The outputs of the photodiodes in each detector module are digitized and processed, similarly to those of the reference detector module, to obtain indications of the amounts of light of each wavelength scattered to the corresponding receiving position. The value for each wavelength at each position is also normalized to the reference laser-power level for that wavelength. From these normalized values, the density and the mass flow rate of the fluid are estimated.

Wiley, John↗

Characterization of Advanced Avalanche Photodiodes for Water Vapor Lidar Receivers

Development of advanced differential absorption lidar (DIAL) receivers is very important to increase the accuracy of atmospheric water vapor measurements. A major component of such receivers is the optical detector. In the near-infrared wavelength range avalanche photodiodes (APD's) are the best choice for higher signal-to-noise ratio, where there are many water vapor absorption lines. In this study, characterization experiments were performed to evaluate a group of silicon-based APD's. The APD's have different structures representative of different manufacturers. The experiments include setups to calibrate these devices, as well as characterization of the effects of voltage bias and temperature on the responsivity, surface scans, noise measurements, and frequency response measurements. For each experiment, the setup, procedure, data analysis, and results are given and discussed. This research was done to choose a suitable APD detector for the development of an advanced atmospheric water vapor differential absorption lidar detection system operating either at 720, 820, or 940 nm. The results point out the benefits of using the super low ionization ratio (SLIK) structure APD for its lower noise-equivalent power, which was found to be on the order of 2 to 4 fW/Hz(sup (1/2)), with an appropriate optical system and electronics. The water vapor detection systems signal-to-noise ratio will increase by a factor of 10.

Refaat, Tamer F.↗

Method and Apparatus for Determining Position Using Global Positioning Satellites

A global positioning satellite receiver having an antenna for receiving a L1 signal from a satellite is presented. The L1 signal is processed by a preamplifier stage including a band pass filter and a low noise amplifier and output as a radio frequency (RF) signal. A mixer receives and de-spreads the RF signal in response to a pseudo-random noise code, i,e., Gold code, generated by an internal pseudo-random noise code generator. A microprocessor enters a code tracking loop, such that during the code tracking loop, it addresses the pseudorandom code generator to cause the pseudo-random code generator to sequentially output pseudo-random codes corresponding to satellite codes used to spread the L1 signal, until correlation occurs. When an output of the mixer is indicative of the occurrence of correlation between the RF signal and the generated pseudo-random codes, the microprocessor caters an operational state which slows the receiver code sequence to stay locked with the satellite cede sequence. The output of the mixer is provided to a detector which, in turn, controls certain routines of the microprocessor. The microprocessor will output pseudo range information according to an interrupt routine in response detection of correlation. The pseudo range information is to be telemetered to a ground station which determines the position of the global positioning satellite receiver.

John L Ward↗

Method and apparatus for determining position using global positioning satellites

A global positioning satellite receiver having an antenna for receiving a L1 signal from a satellite. The L1 signal is processed by a preamplifier stage including a band pass filter and a low noise amplifier and output as a radio frequency (RF) signal. A mixer receives and de-spreads the RF signal in response to a pseudo-random noise code, i.e., Gold code, generated by an internal pseudo-random noise code generator. A microprocessor enters a code tracking loop, such that during the code tracking loop, it addresses the pseudo-random code generator to cause the pseudo-random code generator to sequentially output pseudo-random codes corresponding to satellite codes used to spread the L1 signal, until correlation occurs. When an output of the mixer is indicative of the occurrence of correlation between the RF signal and the generated pseudo-random codes, the microprocessor enters an operational state which slows the receiver code sequence to stay locked with the satellite code sequence. The output of the mixer is provided to a detector which, in turn, controls certain routines of the microprocessor. The microprocessor will output pseudo range information according to an interrupt routine in response detection of correlation. The pseudo range information is to be telemetered to a ground station which determines the position of the global positioning satellite receiver.

Ward, John↗

Astronomical application of IR CID technology

A portable microcomputer data system was developed to test a 2 x 64-element Si:Bi charge injection device (CID) infrared detector array on the Lick Observatory Shane telescope. An existing 0.5 m spectrograph was used for the tests after modification, and a spectral resolution of 1000 was achieved. Slow device response, due to the low background conditions in the spectrograph were shown. Astronomical data were later obtained, and a device read noise on the order of a few hundred electrons was achieved. The signal to noise ratios of the resulting spectra were about a factor of five lower than what could have been achieved with discrete photoconductive detectors. It is concluded that the CID array is competitive for applications in backgrounds lower than those used in the tests.

Rank, D. M.↗

Automated Test Systems for Toxic Vapor Detectors

The NASA Toxic Vapor Detection Laboratory (TVDL) at the Kennedy Space Center (KSC), Florida, has been using Personal Computer based Data Acquisition and Control Systems (PCDAS) for about nine years. These systems control the generation of toxic vapors of known concentrations under controlled conditions of temperature and humidity. The PCDAS also logs the test conditions and the test article responses in data files for analysis by standard spreadsheets or custom programs. The PCDAS was originally developed to perform standardized qualification and acceptance tests in a search for a commercial off-the-shelf (COTS) toxic vapor detector to replace the hydrazine detectors for the Space Shuttle launch pad. It has since become standard test equipment for the TVDL and is indispensable in producing calibration standards for the new hydrazine monitors at the 10 part per billion (ppb) level. The standard TVDL PCDAS can control two toxic vapor generators (TVG's) with three channels each and two flow/temperature/humidity (FIFH) controllers and it can record data from up to six toxic vapor detectors (TVD's) under test and can deliver flows from 5 to 50 liters per minute (L/m) at temperatures from near zero to 50 degrees Celsius (C) using an environmental chamber to maintain the sample temperature. The concentration range for toxic vapors depends on the permeation source installed in the TVG. The PCDAS can provide closed loop control of temperature and humidity to two sample vessels, typically one for zero gas and one for the standard gas. This is required at very low toxic vapor concentrations to minimize the time required to passivate the sample delivery system. Recently, there have been several requests for information about the PCDAS by other laboratories with similar needs, both on and off KSC. The purpose of this paper is to inform the toxic vapor detection community of the current status and planned upgrades to the automated testing of toxic vapor detectors at the Kennedy Space Center.

Mattson, C. B.↗

Automated Test Systems for Toxic Vapor Detectors

The NASA Toxic Vapor Detection Laboratory (TVDL) at the Kennedy Space Center (KSC), Florida, has been using Personal Computer based Data Acquisition and Control Systems (PCDAS) for about nine years. These systems control the generation of toxic vapors of known concentrations under controlled conditions of temperature and humidity. The PCDAS also logs the test conditions and the test article responses in data files for analysis by standard spreadsheets or custom programs. The PCDAS was originally developed to perform standardized qualification and acceptance tests in a search for a commercial off-the-shelf (COTS) toxic vapor detector to replace the hydrazine detectors for the Space Shuttle launch pad. It has since become standard test equipment for the TVDL and is indispensable in producing calibration standards for the new hydrazine monitors at the 10 part per billion (ppb) level. The standard TVDL PCDAS can control two toxic vapor generators (TVG's) with three channels each and two flow/ temperature / humidity (FTH) controllers and it can record data from up to six toxic vapor detectors (TVD's) under test and can deliver flows from 5 to 50 liters per minute (L/m) at temperatures from near zero to 50 degrees Celsius (C) using an environmental chamber to maintain the sample temperature. The concentration range for toxic vapors depends on the permeation source installed in the TVG. The PCDAS can provide closed loop control of temperature and humidity to two sample vessels, typically one for zero gas and one for the standard gas. This is required at very low toxic vapor concentrations to minimize the time required to passivate the sample delivery system. Recently, there have been several requests for information about the PCDAS by other laboratories with similar needs, both on and off KSC. The purpose of this paper is to inform the toxic vapor detection community of the current status and planned upgrades to the automated testing of toxic vapor detectors at the Kennedy Space Center.

Mattson, C. B.↗

Development of High-Performance Detector Technology for UV and IR Applications

Sensing and imaging for ultraviolet (UV) and infrared (IR) bands has many applications for NASA, defense, and commercial systems. Recent work has involved developing UV avalanche photodiode (UVAPD) arrays with high gain for high resolution imaging. Various GaN/AlGaN p-i-n UV-APDs have been fabricated from epitaxial structures grown by metalorganic chemical vapor deposition (MOCVD) on GaN substrates with avalanche gains greater than 5×105, and high responsivities. Similarly, the IR spectral band is useful for measuring ocean temperatures, atmospheric aerosols, forest fires, etc. We are also developing room temperature operating graphene-enhanced PbSe midwave infrared (MWIR) detectors and focal plane arrays (FPAs). These compact and low-cost MWIR sensors can benefit various NASA remote sensing applications. Here we present recent results from these high performance UV- and IR-band detector and FPA technologies.

Sood, Ashok K.↗

Spectral Characterizations of the Clouds and the Earth's Radiant Energy System (CERES) Thermistor Bolometers using Fourier Transform Spectrometer (FTS) Techniques

Fourier Transform Spectrometer (FTS) techniques are being used to characterize the relative spectral response, or sensitivity, of scanning thermistor bolometers in the infrared (IR) region (2 - >= 100-micrometers). The bolometers are being used in the Clouds and the Earth's Radiant Energy System (CERES) program. The CERES measurements are designed to provide precise, long term monitoring of the Earth's atmospheric radiation energy budget. The CERES instrument houses three bolometric radiometers, a total wavelength (0.3- >= 150-micrometers) sensor, a shortwave (0.3-5-micrometers) sensor, and an atmospheric window (8-12-micrometers) sensor. Accurate spectral characterization is necessary for determining filtered radiances for longwave radiometric calibrations. The CERES bolometers spectral response's are measured in the TRW FTS Vacuum Chamber Facility (FTS - VCF), which uses a FTS as the source and a cavity pyroelectric trap detector as the reference. The CERES bolometers and the cavity detector are contained in a vacuum chamber, while the FTS source is housed in a GN2 purged chamber. Due to the thermal time constant of the CERES bolometers, the FTS must be operated in a step mode. Data are acquired in 6 IR spectral bands covering the entire longwave IR region. In this paper, the TRW spectral calibration facility design and data measurement techniques are described. Two approaches are presented which convert the total channel FTS data into the final CERES spectral characterizations, producing the same calibration coefficients (within 0.1 percent). The resulting spectral response curves are shown, along with error sources in the two procedures. Finally, the impact of each spectral response curve on CERES data validation will be examined through analysis of filtered radiance values from various typical scene types.

Thornhill, K. Lee↗

Stripe filters on multispectral linear arrays

Dielectric interference filters deposited directly on top of existing 200 element charge coupled device linear imaging arrays were designed, fabricated and evaluated. The optical performance of the filters was verified with regard to crosstalk between adjacent detector elements. The filters showed an average in-band transmittance greater than 80% and a total out of band transmittance of less than 5%. Filter stability was adequate for operation in a space environment. The filter elements were definable in 12 to 25 micron element size compatible with existing silicon detectors. These type of measurement were made: (1) spectral transmission of the filter as deposited on witness plates; (2) spectral response of the silicon sensing device; (3) any optical interaction between filter and sensing device; (4) the response of the filter/sensor combination; and (5) repeatability and uniformity of filter characteristics. Detailed discussion of these evaluations are given.

Hall, J. H.↗

X-ray optics. II - A technique for high resolution spectroscopy

A novel combination of optical elements and properties is combined to achieve high-spectral resolution using grazing incidence optics of modest quality. Analysis and ray tracing of examples show that using radial groove gratings at high blaze angles in the manner of an echelle spectrograph can provide high spectral resolution. This arrangement is compared to the conventional in-plane designs to show that the off-plane is superior in nearly every respect. Cross dispersion can be provided by the energy resolution of a CCD detector. Additional resolution can be squeezed from the system by strategic placement of gratings to take advantage of the azimuthal response of a Wolter X-ray optic.

Cash, Webster C., Jr.↗