Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “coverage”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 793 records · Page 44

Dosimetric errors during treatment of centrally located lung tumors with stereotactic body radiation therapy: Monte Carlo evaluation of tissue inhomogeneity corrections

Early experience with stereotactic body radiation therapy (SBRT) of centrally located lung tumors indicated increased rate of high-grade toxicity in the lungs. These clinical results were based on treatment plans that were computed using pencil beam–like algorithms and without tissue inhomogeneity corrections. In this study, we evaluated the dosimetric errors in plans with and without inhomogeneity corrections and with planning target volumes (PTVs) that were within the zone of the proximal bronchial tree (BT). For 10 patients, the PTV, lungs, and sections of the BT either inside or within 2 cm of the PTV were delineated. Two treatment plans were generated for each patient using the following dose-calculation methods: (1) pencil beam (PB) algorithm without inhomogeneity correction (IC) (PB − IC) and (2) PB with inhomogeneity correction (PB + IC). Both plans had identical beam geometry but different beam segment shapes and monitor units (MU) to achieve similar conformal dose coverage of PTV. To obtain the baseline dose distributions, each plan was recalculated using a Monte Carlo (MC) algorithm by keeping MUs the same in the respective plans. The median maximum dose to the proximal BT and PTV dose coverage in the PB + IC plans were overestimated by 8% and 11%, respectively. However, the median maximum dose to the proximal BT and PTV dose coverage in PB − IC plans were underestimated by 15% and 9%. Similar trends were observed in low-dose regions of the lung within the irradiated volume. Our study indicates that dosimetric bias introduced by unit tissue density plans cannot be characterized as underestimation or overestimation of dose without taking the tumor location into account. This issue should be considered when analyzing clinical toxicity data from early lung SBRT trials that utilized unit tissue density for dose calculations.

61 RADIATION PROTECTION AND DOSIMETRY↗

Evaluation of bolus electron conformal therapy compared with conventional techniques for the treatment of left chest wall postmastectomy in patients with breast cancer

Postmastectomy radiation (PMRT) lowers local-regional recurrence risk and improves survival in selected patients with breast cancer. The chest wall and lower axilla are technically challenging areas to treat with homogenous doses and normal tissue sparing. This study compares several techniques for PMRT to provide data to guide selection of optimal treatment techniques. Twenty-five consecutive left-sided patients treated postmastectomy were contoured using Radiation Therapy Oncology Group (RTOG) atlas guidelines then planned using 4 different PMRT techniques: opposed tangents with wedges (3-dimensional [3D] wedges), opposed tangents with field-in-field (FiF) modulation, 8-field intensity modulation radiotherapy (IMRT), and custom bolus electron conformal therapy (BolusECT, .decimal, Inc., Sanford, FL). Required planning target volume (PTV) coverage was held constant, and then dose homogeneity and normal tissue dose parameters were compared among the 4 techniques. BolusECT achieved clincally acceptable PTV coverage for 22 out of 25 cases. Compared with either tangential technique, IMRT and BolusECT provided the lowest heart V{sub 25} doses (3.3% ± 0.9% and 6.6% ± 3.2%, respectively with p < 0.0001). FiF had the lowest mean total lung dose (7.3 ± 1.1 Gy, with p = 0.0013), IMRT had the lowest total lung V{sub 20} (10.3% ± 1.6%, p < 0.0001), and BolusECT had the lowest mean heart dose (7.3 ± 2.0 Gy, p = 0.0002). IMRT provided the optimal dose homogeneity and normal tissue sparing compared with all other techniques for the cases in which BolusECT could not achieve acceptable PTV coverage. IMRT generally exposes contralateral breast and lung to slightly higher doses. Optimal PMRT technique depends upon patient anatomy. Patients whose maximal target volume depth is about 5.7 cm or less can be treated with BolusECT-assisted 12 or 15 MeV electron beams. At these energies, BolusECT has comparable dose-volume statistics as IMRT and lower heart V{sub 25} than opposed tangential beams. Patients with larger depths are best treated with IMRT, which provides significant advantages in both dose homogeneity and normal tissue sparing compared with all other techniques.

61 RADIATION PROTECTION AND DOSIMETRY↗

Left-sided breast cancer irradiation using rotational and fixed-field radiotherapy

The 3-dimensional conformal radiotherapy (3DCRT) technique is the standard for breast cancer radiotherapy. During treatment planning, not only the coverage of the planning target volume (PTV) but also the minimization of the dose to critical structures, such as the lung, heart, and contralateral breast tissue, need to be considered. Because of the complexity and variations of patient anatomy, more advanced radiotherapy techniques are sometimes desired to better meet the planning goals. In this study, we evaluated external-beam radiation treatment techniques for left breast cancer using various delivery platforms: fixed-field including TomoDirect (TD), static intensity-modulated radiotherapy (sIMRT), and rotational radiotherapy including Elekta volumetric-modulated arc therapy (VMAT) and tomotherapy helical (TH). A total of 10 patients with left-sided breast cancer who did or did not have positive lymph nodes and were previously treated with 3DCRT/sIMRT to the entire breast were selected, their treatment was planned with Monaco VMAT, TD, and TH. Dosimetric parameters including PTV coverage, organ-at-risk (OAR) sparing, dose-volume histograms, and target minimum/maximum/mean doses were evaluated. It is found that for plans providing comparable PTV coverage, the Elekta VMAT plans were generally more inhomogeneous than the TH and TD plans. For the cases with regional node involvement, the average mean doses administered to the heart were 9.2 (± 5.2) and 8.8 (± 3.0) Gy in the VMAT and TH plans compared with 11.9 (± 6.4) and 11.8 (± 9.2) Gy for the 3DCRT and TD plans, respectively, with slightly higher doses given to the contralateral lung or breast or both. On average, the total monitor units for VMAT plans are 11.6% of those TH plans. Our studies have shown that VMAT and TH plans offer certain dosimetric advantages over fixed-field IMRT plans for advanced breast cancer requiring regional nodal treatment. However, for early-stage breast cancer fixed-field radiotherapy is potentially more beneficial in terms of OAR sparing.

61 RADIATION PROTECTION AND DOSIMETRY↗

Optimal beam design on intensity-modulated radiation therapy with simultaneous integrated boost in nasopharyngeal cancer

This study aims to determine the optimal beam design among various combinations of field numbers and beam trajectories for intensity-modulated radiation therapy (IMRT) with simultaneous integrated boost (SIB) technique for the treatment of nasopharyngeal cancer (NPC). We used 10 fields with gantry angles of 155°, 130°, 75°, 25°, 0° L, 0° R, 335°, 285°, 230°, and 205° denoted as F10. To decrease doses in the spinal cord, the F10 technique was designed by featuring 2 pairs of split-opposed beam fields at 155° to 335° and 205° to 25°, as well as one pair of manually split beam fields at 0°. The F10 technique was compared with 4 other common field arrangements: F7E, 7 fields with 50° equally spaced gantry angles; F7, the basis of F10 with 155°, 130°, 75°, 0°, 285°, 230°, and 205°; F9E, 9 fields with 40° equally spaced gantry angles; and FP, 7 posterior fields with 180°, 150°, 120°, 90°, 270°, 240°, and 210°. For each individual case of 10 patients, the customized constraints derived after optimization with the standard F10 technique were applied to 4 other field arrangements. The 4 new optimized plans of each individual case were normalized to achieve the same coverage of planning target volume (PTV){sub 63} {sub Gy} as that of the standard F10 technique. The F10 field arrangement exhibited the best coverage in PTV{sub 70} {sub Gy} and the least mean dose in the trachea-esophagus region. Furthermore, the F10 field arrangement demonstrated the highest level of conformity in the low-dose region and the least monitor unit. The F10 field arrangement performed more outstandingly than the other field arrangements in PTV{sub 70} {sub Gy} coverage and spared the central organ. This arrangement also exhibited the highest conformity and delivery efficiency. The F10 technique is recommended as the standard beam geometry for the SIB-IMRT of NPC.

61 RADIATION PROTECTION AND DOSIMETRY↗

Dosimetric experience with 2 commercially available multilumen balloon-based brachytherapy to deliver accelerated partial-breast irradiation

The purpose of this work was to report dosimetric experience with 2 kinds of multilumen balloon (MLB), 5-lumen Contura MLB (C-MLB) and 4-lumen MammoSite MLB (MS-MLB), to deliver accelerated partial-breast irradiation, and compare the ability to achieve target coverage and control skin and rib doses between 2 groups of patients treated with C-MLB and MS-MLB brachytherapy. C-MLB has 5 lumens, the 4 equal-spaced peripheral lumens are 5 mm away from the central lumen. MS-MLB has 4 lumens, the 3 equal-spaced peripheral lumens are 3 mm away from the central lumen. In total, 43 patients were treated, 23 with C-MLB, and 20 with MS-MLB. For C-MLB group, 8 patients were treated with a skin spacing < 7 mm and 12 patients with rib spacing < 7 mm. For MS-MLB group, 2 patients were treated with a skin spacing < 7 mm and 5 patients with rib spacing < 7 mm. The dosimetric goals were (1) ≥ 95% of the prescription dose (PD) covering ≥ 95% of the target volume (V{sub 95%} ≥ 95%), (2) maximum skin dose ≤ 125% of the PD, (3) maximum rib dose ≤ 145% of the PD (if possible), and (4) the V{sub 150%} ≤ 50 cm{sup 3} and V{sub 200%} ≤ 10 cm{sup 3}. All dosimetric criteria were met concurrently in 82.6% of C-MLB patients, in 80.0% of MS-MLB patients, and in 81.4% of all 43 patients. For each dosimetric parameter, t-test of these 2 groups showed p > 0.05. Although the geometric design of C-MLB is different from that of MS-MLB, both applicators have the ability to shape the dose distribution and to provide good target coverage, while limiting the dose to skin and rib. No significant difference was observed between the 2 patient groups in terms of target dose coverage and dose to organs at risk.

61 RADIATION PROTECTION AND DOSIMETRY↗

Comparison of a new noncoplanar intensity-modulated radiation therapy technique for craniospinal irradiation with 3 coplanar techniques

When standard conformal x-ray technique for craniospinal irradiation is used, it is a challenge to achieve satisfactory dose coverage of the target including the area of the cribriform plate, while sparing organs at risk. We present a new intensity-modulated radiation therapy (IMRT), noncoplanar technique, for delivering irradiation to the cranial part and compare it with 3 other techniques and previously published results. A total of 13 patients who had previously received craniospinal irradiation with standard conformal x-ray technique were reviewed. New treatment plans were generated for each patient using the noncoplanar IMRT-based technique, a coplanar IMRT-based technique, and a coplanar volumetric-modulated arch therapy (VMAT) technique. Dosimetry data for all patients were compared with the corresponding data from the conventional treatment plans. The new noncoplanar IMRT technique substantially reduced the mean dose to organs at risk compared with the standard radiation technique. The 2 other coplanar techniques also reduced the mean dose to some of the critical organs. However, this reduction was not as substantial as the reduction obtained by the noncoplanar technique. Furthermore, compared with the standard technique, the IMRT techniques reduced the total calculated radiation dose that was delivered to the normal tissue, whereas the VMAT technique increased this dose. Additionally, the coverage of the target was significantly improved by the noncoplanar IMRT technique. Compared with the standard technique, the coplanar IMRT and the VMAT technique did not improve the coverage of the target significantly. All the new planning techniques increased the number of monitor units (MU) used—the noncoplanar IMRT technique by 99%, the coplanar IMRT technique by 122%, and the VMAT technique by 26%—causing concern for leak radiation. The noncoplanar IMRT technique covered the target better and decreased doses to organs at risk compared with the other techniques. All the new techniques increased the number of MU compared with the standard technique.

61 RADIATION PROTECTION AND DOSIMETRY↗

Relative plan robustness of step-and-shoot vs rotational intensity–modulated radiotherapy on repeat computed tomographic simulation for weight loss in head and neck cancer

Introduction: Interfractional anatomical alterations may have a differential effect on the dose delivered by step-and-shoot intensity-modulated radiotherapy (IMRT) and volumetric-modulated arc therapy (VMAT). The increased degrees of freedom afforded by rotational delivery may increase plan robustness (measured by change in target volume coverage and doses to organs at risk [OARs]). However, this has not been evaluated for head and neck cancer. Materials and methods: A total of 10 patients who required repeat computed tomography (CT) simulation and replanning during head and neck IMRT were included. Step-and-shoot IMRT and VMAT plans were generated from the original planning scan. The initial and second CT simulation scans were fused and targets/OAR contours transferred, reviewed, and modified. The plans were applied to the second CT scan and doses recalculated without repeat optimization. Differences between step-and-shoot IMRT and VMAT for change in target volume coverage and doses to OARs between first and second CT scans were compared by Wilcoxon signed rank test. Results: There were clinically relevant dosimetric changes between the first and the second CT scans for both the techniques (reduction in mean D{sub 95%} for PTV2 and PTV3, D{sub min} for CTV2 and CTV3, and increased mean doses to the parotid glands). However, there were no significant differences between step-and-shoot IMRT and VMAT for change in any target coverage parameter (including D{sub 95%} for PTV2 and PTV3 and D{sub min} for CTV2 and CTV3) or dose to any OARs (including parotid glands) between the first and the second CT scans. Conclusions: For patients with head and neck cancer who required replanning mainly due to weight loss, there were no significant differences in plan robustness between step-and-shoot IMRT and VMAT. This information is useful with increased clinical adoption of VMAT.

61 RADIATION PROTECTION AND DOSIMETRY↗

Dosimetric comparison of helical tomotherapy, intensity-modulated radiation therapy, volumetric-modulated arc therapy, and 3-dimensional conformal therapy for the treatment of T1N0 glottic cancer

Various radiotherapy planning methods for T1N0 laryngeal cancer have been proposed to decrease normal tissue toxicity. We compare helical tomotherapy (HT), linac-based intensity-modulated radiation therapy (IMRT), volumetric-modulated arc therapy (VMAT), and 3-D conformal radiotherapy (3D-CRT) techniques for T1N0 laryngeal cancer. Overall, 10 patients with T1N0 laryngeal cancer were selected and evaluated. Furthermore, 10 radiotherapy treatment plans have been created for all 10 patients, including HT, IMRT, VMAT, and 3D-CRT. IMRT, VMAT, and HT plans vs 3D-CRT plans consistently provided superior planning target volume (PTV) coverage. Similar target coverage was observed between the 3 IMRT modalities. Compared with 3D-CRT, IMRT, HT, and VMAT significantly reduced the mean dose to the carotid arteries. VMAT resulted in the lowest mean dose to the submandibular and thyroid glands. Compared with 3D-CRT, IMRT, HT, and VMAT significantly increased the maximum dose to the spinal cord It was observed that the 3 IMRT modalities studied showed superior target coverage with less variation between each plan in comparison with 3D-CRT. The 3D-CRT plans performed better at the D{sub max} of the spinal cord. Clinical investigation is warranted to determine if these treatment approaches would translate into a reduction in radiation therapy–induced toxicities.

61 RADIATION PROTECTION AND DOSIMETRY↗

Whole breast nodal irradiation using supine VMAT and prone 3D planning: A case study

The purpose of this study was to compare the variations in doses to the ipsilateral lung and heart between the supine whole breast and nodal volumetric-modulated arc therapy (VMAT) technique and the prone 3-dimensional conformal radiation therapy (3DCRT) technique. In this study, 3 patients who were simulated in the prone and supine positions were planned using supine VMAT and prone 3DCRT techniques to compare planning target volume (PTV) coverage as well as dose to organs at risk (ORs), including the heart and ipsilateral lung. Although all constraints were met, the ideal treatment technique depended on the patient's anatomy and lumpectomy location. Supine VMAT provided excellent coverage to the target structures but encountered difficulty in limiting dose to the ipsilateral lung and heart. When compared with the supine VMAT technique, the prone 3DCRT limited dose to the ipsilateral lung and heart but provided less dose coverage to the target volumes.

61 RADIATION PROTECTION AND DOSIMETRY↗

Study for reducing lung dose of upper thoracic esophageal cancer radiotherapy by auto-planning: volumetric-modulated arc therapy vs intensity-modulated radiation therapy

This study aimed to investigate the dosimetric differences and lung sparing between volumetric-modulated arc therapy (VMAT) and intensity-modulated radiation therapy (IMRT) in the treatment of upper thoracic esophageal cancer with T3N0M0 for preoperative radiotherapy by auto-planning (AP). Sixteen patient cases diagnosed with upper thoracic esophageal cancer T3N0M0 for preoperative radiotherapy were retrospectively studied, and 3 plans were generated for each patient: full arc VMAT AP plan with double arcs, partial arc VMAT AP plan with 6 partial arcs, and conventional IMRT AP plan. A simultaneous integrated boost with 2 levels was planned in all patients. Target coverage, organ at risk sparing, treatment parameters including monitor units and treatment time (TT) were evaluated. Wilcoxon signed-rank test was used to check for significant differences (p 20 ), 25 Gy (V{sub 25}), 30 Gy (V{sub 30}), 35 Gy (V{sub 35}), 40 Gy (V{sub 40}), and without increasing the value of V{sub 10}, V{sub 13}, and V{sub 15}. For V{sub 5} of total lung value, pVMAT was similar to aIMRT, and it was better than fVMAT. Both pVMAT and fVMAT improved the target dose coverage and significantly decreased maximum dose for the spinal cord, monitor unit, and TT. No significant difference was observed with respect to V{sub 10} and V{sub 15} of body. VMAT AP plan was a good option for treating upper thoracic esophageal cancer with T3N0M0, especially partial arc VMAT AP plan. It had the potential to effectively reduce lung dose in a shorter TT and with superior target coverage and dose homogeneity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Photon optimizer (PO) vs progressive resolution optimizer (PRO): a conformality- and complexity-based comparison for intensity-modulated arc therapy plans

This study aimed to provide guidance on the advantages and limitations of a new optimizer, “photon optimizer” (PO), when compared with its predecessor, “progressive resolution optimizer” (PRO), for intensity-modulated arc therapy (IMAT) plans. Eleven study plans that included a cohort of prostate, head and neck, and brain treatment sites were optimized using both PRO and PO algorithms. A plan template using the same objectives for the same number of iterations was used for each optimized plan to obtain hypothetical treatment plans that would be comparable with a clinical plan. Analysis was performed using plan conformity-based parameters such as target volume coverage factor, conformation number and homogeneity indices, and plan complexity assessment parameters such as small aperture score, modulation indices, and monitor unit variation with arc angle for prostate, brain and head, and neck IMAT treatment plans. Plan conformality analysis demonstrated that conformation numbers, target volume coverage factors, and homogeneity indices produced by the 2 optimizers were comparable for most anatomic sites. IMAT treatment plans produced using the PRO optimizer were found to be less complex than plans produced using the PO optimizer, in terms of multileaf collimator (MLC) leaf position variability and modulation complexity scores. Similarly, the PRO optimizer was shown to produce treatment plans that used fewer monitor units (and generally fewer monitor unit per degree of arc rotation) than PO optimizer. This study demonstrated that the PO optimizer can produce IMAT treatment plans with a similar degree of dose conformity to the target volume and generally improved organ at risk sparing, compared with the PRO optimizer. Better coverage to organs at risk produced by plans optimized using PO was observed to have higher MLC variability and monitor units. Therefore, careful evaluation of treatment plan conformity and complexity before assessing its deliverability is recommended when implementing the routine use of PO optimizer.

61 RADIATION PROTECTION AND DOSIMETRY↗

A muon–ion collider at BNL: The future QCD frontier and path to a new energy frontier of μ + μ – colliders

In this work, we propose the development and construction of a novel muon–ion collider (MuIC) at Brookhaven National Laboratory (BNL) in the USA as an upgrade to succeed the electron–ion collider (EIC) that is scheduled to commence in the early 2030s, by a joint effort of the nuclear and particle physics communities. The BNL facility could accommodate a muon storage beam with an energy up to about 1 TeV with existing magnet technology. When collided with a 275 GeV hadron beam, the MuIC center-of-mass energy of about 1 TeV will extend the kinematic coverage of deep inelastic scattering physics at the EIC (with polarized beams) by more than an order of magnitude in Q 2 and x, opening a new QCD frontier to address many fundamental scientific questions in nuclear and particle physics. This coverage is comparable to that of the proposed Large Hadron–Electron Collider (LHeC) at CERN, but with complementary lepton and hadron kinematics, ion species, and beam polarization. Additionally, the development of a MuIC at BNL will focus the worldwide R&D efforts on muon collider technology and serve as a demonstrator toward a future muon–antimuon collider at O(10) TeV energy, which is an attractive option to reach the next high energy frontier in particle physics at an affordable cost and a smaller footprint than a future circular hadron collider. We discuss here the possible design parameters of the MuIC, kinematic coverage, science cases, and detector design considerations including resolution estimates on DIS kinematic variables. A possible road map toward the future MuIC and muon–antimuon colliders is also presented.

43 PARTICLE ACCELERATORS↗

Hydrogen adsorption on Ru(001) studied by Scanning TunnelingMicroscopy

The adsorption of hydrogen on Ru(001) was studied by scanning tunneling microscopy at temperatures around 50 K. Hydrogen was found to adsorb dissociatively forming different ordered structures as a function of coverage. In order of increasing coverage {theta} in monolayers (ML) these were ({radical}3 x {radical}3)r30{sup o} at {theta} = 0.3 ML; (2 x 1) at {theta} = 0.50 ML, (2 x 2)-3H at {theta} = 0.75, and (1 x 1) at {theta} = 1.00. Some of these structures were observed to coexist at intermediate coverage values. Close to saturation of 1 ML, H-vacancies (unoccupied three fold fcc hollow Ru sites) were observed either as single entities or forming transient aggregations. These vacancies diffuse and aggregate to form active sites for the dissociative adsorption of hydrogen.

36 MATERIALS SCIENCE↗

Reactions of Vinyl Groups on a Model Chromia Surface: Vinyl Chloride on Stoichiometric Alpha-Cr2O3 (1012)

The thermal reaction of vinyl chloride on nearly-stoichiometric ?-Cr2O3 View the MathML source produces gas phase acetylene, ethylene, 1,3-butadiene, and dihydrogen, and results in the deposition of chlorine adatoms. No surface carbon or combustion products (CO, CO2, H2O) are observed. Thermal desorption and spectroscopic studies indicate that the surface reaction of vinyl chloride proceeds through C-Cl bond cleavage to form Cl adatoms and surface vinyl groups which dehydrogenate to acetylene, hydrogenate to ethylene, and couple to form butadiene. Cl adatoms affect surface reactivity in two ways: (1) by increasing the barrier to vinyl dehydrogenation from 145 to 160 kJ/mol, and (2) by blocking Cr3+ sites which shuts down the surface chemistry. Selectivity to butadiene is dependent on Cl adatom coverage, where the increased stability of vinyl intermediates at lower Cl coverages gives rise to more butadiene coupling product. At higher Cl coverages, Cl appears to inhibit the mobility of surface vinyl and decreases the reaction probability for coupling. Photoemission and near edge X-ray absorption fine structure (NEXAFS) spectra show that a mixed monolayer of molecular and dissociated vinyl chloride is formed at 130 K. The polarization dependence of the NEXAFS indicates that vinyl chloride ?-bonds with the molecular plane nominally parallel to the surface, while vinyl intermediates ?-bond at Cr centers with the molecular plane nominally perpendicular to the surface, in agreement with DFT predictions of the adsorption geometries.

36 MATERIALS SCIENCE↗

Photochemistry of Methyl Bromide on the α-Cr2O3(0001) Surface

The photochemical properties of the Cr-terminated α-Cr2O3(0001) surface were explored using methyl bromide (CH3Br) as a probe molecule. CH3Br adsorbed and desorbed molecularly from the Cr-terminated α-Cr2O3(0001) surface without detectable thermal decomposition. Temperature programmed desorption (TPD) revealed a CH3Br desorption state at 240 K for coverages up to 0.5 ML, followed by more weakly bound molecules desorbing at 175 K for coverages up to 1 ML. Multilayer exposures led to desorption at ~130 K. The CH3Br sticking coefficient was unity at 105 K for coverages up to monolayer saturation, but decreased as the multilayer formed. In contrast, pre-oxidation of the surface (using an oxygen plasma source) led to capping of surface Cr3+ sites and near complete removal of CH3Br TPD states above 150 K. The photochemistry of chemisorbed CH3Br was explored on the Cr-terminated surface using post-irradiation TPD and photon stimulated desorption (PSD). Irradiation of adsorbed CH3Br with broad band light from a Hg arc lamp resulted in both photodesorption and photodecomposition of the parent molecule at a combined cross section of ~10-22 cm2. Parent PSD was indicative of molecular photodesorption, but CH3 was also detected in PSD and Br atoms were left on the surface, both reflective of photo-induced CH3-Br bond dissociation. Use of a 385 nm cut-off filter effectively shut down the photodissociation pathway but not the parent molecule photodesorption process. From these observations it is inferred that d-to-d transitions in α-Cr2O3, occurring at photon energies <3 eV, are not responsible for photodecomposition of 2 adsorbed CH3Br. It is unclear to what extent band-to-band versus direct CH3Br photolysis play in CH3-Br bond dissociation initiated by more energetic photons.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Visible Light Induced Photodesorption of NO from the α-Cr2O3(0001) Surface

Nitric oxide chemistry and photochemistry on the Cr-terminated surface of α-Cr2O3(0001) was examined using temperature programmed desorption (TPD), sticking coefficient measurements and photodesorption. NO adsorbed at 100 K binds at surface Cr cation sites forming a strongly bound surface species that thermally desorbs at 320-340 K, depending on coverage. No thermal decomposition was detected in TPD in agreement with previous results in the literature. Sticking probability measurements of NO at 100 K indicated near unity sticking for NO coverages up to ~1.3 ML, with additional adsorption with higher exposures at decreased sticking probability. These results suggest that each surface Cr cation site on the α-Cr2O3(0001) surface was capable of binding more than one NO molecule, although it is unclear whether this was as separate NO molecules or as dimers. Photodesorption of adsorbed NO was examined for surface coverages below the 1 ML point. Both visible and UV light were shown to photodesorb NO without detectable NO photodecomposition. Visible light photodesorption of NO occurred with a cross section of ~2x10-19 cm2, which was estimated to greater than that obtained with UV light. The visible light photodesorption event was not associated with bandgap excitation in α-Cr2O3(0001), but instead was linked to excitation of a surface Cr3+-NO- charge transfer complex. These results illustrate that localized photoabsorption events at surface sites with unique optical properties (relative to the bulk) can result in unexpected surface photochemistry. This work was supported by the US Department of Energy, Office of Basic Energy Sciences, Division of Chemical Sciences, Geosciences & Biosciences. Pacific Northwest National Laboratory is operated by Battelle for the US Department of Energy.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Structural and electronic properties of ultrathin picene films on the Ag(100) surface

In this study we investigate using scanning tunneling microscopy and electronic structure calculations the growth, assembly, and electronic properties of picene molecules on the Ag(100), Ag(111), and Cu(111) surfaces, with particular emphasis on Ag(100). In each case, the picene molecules are found to lie parallel to the surface at coverages up to half a monolayer and to adopt alternating parallel and tilted orientations at full monolayer coverage. In the latter case, the arrangement of the molecules is roughly similar to that in the bulk crystal, making ultrathin films of picene interesting model systems and worthwhile to explore its electronic properties. On the 2 metal surfaces considered, the growth mode of picene is quite different from that of its structural isomer pentacene, which forms bilayer coverage on top of a dense monolayer of flat-lying molecules on metal surfaces. Tunneling spectroscopy measurements provide estimates of the energies of several low-lying molecular orbitals as well as of the highest unoccupied molecular orbital of the absorbed picene molecules. From analysis of these results, we establish that the on-site Coulomb repulsion for picene decreases by ~ 2 eV in going from the gas phase to the full monolayer on Ag(100), bringing it close to that of the undoped bulk crystal.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Hydrogen Adsorption and Reaction on RuO2(110)

Ruthenium dioxide is used extensively as a co-catalyst in a wide range of photocatalytic water splitting systems. As such, understanding how it promotes the evolution of hydrogen and oxygen is of high importance. In this study, we employ scanning tunneling microscopy to study the adsorption and reaction of hydrogen on a model RuO2(110) surface. We find that at low coverages H2 dissociates heterolytically to hydride-hydroxyl pairs even at 5 K. The onset temperature for the low coverage H2 dissociation is surprising as it is not expected based on prior temperature programmed desorption studies. At higher coverages, H2 chemisorbs molecularly on bare ruthenium sites that are neighboring the hydride-hydroxyl pairs. Upon annealing, the chemisorbed H2 disappears by 120 K, primarily due to H2 desorption from the surface. Further annealing between 120 K and 295 K leads to the conversion of hydride species to bridging hydroxyls. The bridging hydroxyls ultimately recombine between 450 and 600 K to form water yielding clean RuO2(110) with oxygen vacancies.

Dahal, Arjun P.↗