Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “cost of wind”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 793 records · Page 44

A simple method for modelling fatigue spectra of small wind turbine blades

Small-scale wind turbines have market opportunities in distributed energy generation applications but face future challenges in remaining cost competitive compared with solar photovoltaic systems. High unit costs can be attributed to design conservatism when calculating fatigue loads of key structural components such as the blades. In this study, we use the aeroelastic software FAST to highlight limitations of the International Electrotechnical Commission 61400-2:2013 small wind turbine design standard for calculating fatigue life using the simplified load model. We present a modified method for calculating the fatigue spectra of small wind turbine blades. An advantage of this method is that it does not require complex aeroelastic simulations or field measurements. This modified method is intended to be implemented early in the blade design stage, such as during rotor optimization simulations, allowing for multiple rotor configurations to be rapidly compared.

17 WIND ENERGY↗

Challenges in Rotor Aerodynamic Modeling for Non-Uniform Inflow Conditions

Within an international collaboration framework, the accuracy of rotor aerodynamic models used for design load calculations of wind turbines is being assessed. Where the use of high-fidelity computation fluid dynamics (CFD) and mid-fidelity free-vortex wake (FVW) models has become commonplace within the wind energy community, these still fail to meet the requirements in terms of execution time and computational cost needed for design load calculations. The fast but engineering fidelity blade-element/momentum (BEM) method can therefore still be considered the industry workhorse for design load simulations. At the same time, upscaling of wind turbine rotors makes inflow non-uniformities (e.g. shear, veer, turbulence) more important. The objective of this work is to assess model accuracy in non-uniform inflow conditions, which violate several BEM assumptions. Thereto a comparison in turbulent inflow has been executed including a wide variety of codes, focusing on the DanAero field measurements, where a 2.3-MW turbine was equipped with, among other sensors, a pressure measurement apparatus. The results indicate that, although average load patterns are in good agreement, this does not hold for the unsteady loads that drive fatigue damage and aero-elastic stability. A simplified comparison round in vertical shear was initiated to investigate the observed differences in a more controlled manner. A consistent offset in load amplitude was observed between CFD and free-vortex codes on the one hand and BEM-type codes on the other hand. To shed more light on the observations, dedicated efforts are ongoing to pinpoint the cause for these differences, in the end leading to guidelines for an improved BEM implementation.

17 WIND ENERGY↗

Local Power: Comparing County-Level Renewable Energy Potential to Consumption Using the SLOPE Platform

Wide-scale deployment of renewable energy technologies has the potential to significantly reduce greenhouse gas emissions and mitigate the effects of climate change. Many communities have ambitious clean energy goals with targets for locally generated renewable energy. To inform state and local clean energy planning, analysts from the Joint Institute for Strategic Energy Analysis (JISEA) and National Renewable Energy Laboratory (NREL) used data from NREL's State and Local Planning for Energy (SLOPE) platform to compare annual technical generation potential of renewable energy technologies to modeled electricity consumption in every county of the contiguous United States. Annual costs were calculated to produce a 20% share of electricity consumed annually from each technology to examine localized cost effectiveness of a diversified mix of generation sources. For example, combining distributed and utility-scale wind and solar generation can offset the need for storage and nonintermittent fossil resources to achieve high deployment of renewables. This county-level analysis provides insight into where localized renewable energy generation could cost-effectively match annual electricity consumption.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

The metallurgical structure and mechanical properties at low temperature of Nitronic 40 with particular reference to its use in the construction of models for cryogenic wind tunnels

Nitronic 40 was chosen for the construction of Pathfinder I, an R & D model for use in the National Transonic Facility, because of its good mechanical properties at cryogenic temperatures. Nitronic 40 contains delta ferrite and is in a sensitized condition. Heat treatments carried out to remove residual stresses also caused further sensitization. Experiments showed that heat treatment followed by cryoquenching removed the sensitization without creating residual stresses. Heat treatment at temperatures of 2200 F was used to remove the delta ferrite but with little success and at the cost of massive grain growth. The implications of using degraded Nitronic 40 for cryogenic wind tunnel models are discussed, together with possible acceptance criteria.

Wigley, D. A.↗

Decarbonization and technology cost drivers: considerations for potential future thermoelectric water use in the power sector

The power sector is currently undergoing significant changes, driven by a combination of factors, including decarbonization and technology innovation. This study aims to assess implications of these drivers on U.S. power sector technology futures and the associated water and environmental implications for cooling thermoelectric power plants. Specifically, we evaluate four decarbonization scenarios for the contiguous United States that vary in assumptions concerning demand growth and technology costs, with technology costs driving alternative outcomes that prioritize either technologies that require low amounts of water (such as wind, solar, and battery) or high amounts of water (such as nuclear and carbon capture and storage). These scenarios are executed in a power sector capacity expansion model and compared to two reference scenarios that assume status quo with policy and cost drivers. Our analysis indicates that future U.S. thermoelectric water withdrawals could decrease by 25%–60%, but water consumption could more than triple in some scenarios. These changes are driven by a combination of retirement of some power facilities, shifts in cooling technologies, and new technology deployment. The water use patterns vary across the United States, with the eastern regions demonstrating a lot more variability in water consumption across scenarios than western regions. However, local concerns can influence these possible investments, since increased water consumption can exacerbate water scarcity, leading to conflicts among competing users and affecting regional social, environmental, and economic dynamics. Future work should consider possible costs associated with alternate water sources, as well as improve the representation of water constraints within simulations. Inclusion of extreme events and alternate modeling platforms (e.g. production cost modeling and resource adequacy) may also be warranted to further stress test the robustness of these possible technology futures. Such assessments will be critical for ensuring decarbonization and other infrastructure-oriented investments lead to a reliable and resilient power grid.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Multiscale Electricity Modeling for Evaluating Carbon Capture and Sequestration Technologies (Final Report)

Carbon capture and sequestration (CCS) technologies that can operate with a high degree of operating flexibility could provide necessary electric grid flexibility in a system with high shares of variable renewables. This project examines the deployment and dispatch potential of twelve unique flexible CCS (FLECCS) technologies that encompass post-combustion carbon dioxide (CO 2 ) capture designs, concepts using a storage media to enable energy arbitrage, and hybrid processes that integrate CCS with direct air capture (DAC) for flexibility with net zero or negative CO 2 emissions. FLECCS technology potential is explored with a multi-model, multi-scale framework including the Regional Energy Deployment System (ReEDS) electric sector capacity expansion model (CEM) and the PLEXOS production cost model (PCM). Innovative methods were developed to represent FLECCS technology operating modes, performance, and cost in the two models. ReEDS was then used to simulate nine scenarios for each FLECCS technology, three CO 2 emissions price futures reaching $\$$150, $\$$225, and $\$$300/tCO 2 in 2050; and three scenarios for FLECCS technology deployment favorability relative to competing technologies. For each CO 2 price and reference FLECCS favorability, the 2050 infrastructures from ReEDS model are downscaled and implemented in PLEXOS to examine hourly dispatch under detailed operational constraints that are not included in ReEDS. FLECCS technologies exhibited a wide range of deployment potential ranging from none to several hundred gigawatts of capacity, with outcomes highly sensitive to input cost and performance parameters that are inherently highly uncertain. When deployed, FLECCS tended to displace a combination of wind, solar, and natural gas-based technologies rather than supporting increased renewable deployment. As a result, CO 2 emissions reductions facilitated by FLECCS deployment tended to come with higher overall system costs and electricity prices. When economically competitive, FLECCS technologies can contribute significant flexible generation and firm capacity to the grid, but continued technology development and an expanded analytical scope are necessary to fully understand FLECCS deployment potential its impact on the electric power sector. Follow-on analysis incorporating captured CO 2 tax credit value from the Inflation Reduction Act (IRA) and other potential policy scenarios could be particularly valuable, as this policy can substantially change the relative competitiveness of FLECCS technologies.

03 NATURAL GAS↗

Comparison of Coupled and Uncoupled Modeling of Floating Wind Farms with Shared Anchors

As design options for floating wind farms continue to be explored, shared (or multiline) anchors that secure mooring lines from multiple turbines remain a promising technology that can potentially reduce the number of anchors and overall mooring costs. This study evaluates two methods for analyzing the loads on shared anchors: one in which floating offshore wind turbines are simulated individually (using the software OpenFAST), and one in which an entire floating wind farm is simulated collectively (using the software FAST.Farm). A three-line shared anchor is evaluated for multiple loading scenarios in deep water, using the International Energy Agency 15 MW turbine on the VolturnUS-S semisubmersible platform. While the two methods produce broadly comparable results, the coupled wave loading on platforms within the farm results in wave force cancellations and amplifications that decrease multiline force directional ranges and increase multiline force extreme values (up to 7%) and standard deviations (up to 11%) for wave-driven load cases. The inclusion of wakes in FAST.Farm also reduces the net load on the shared anchor due to the velocity deficit, leading to larger differences between OpenFAST and FAST.Farm (up to 3% difference in mean loads) for load cases with operational turbines.

17 WIND ENERGY↗

The optimum hypersonic wind tunnel

The capabilities of existing hypersonic wind tunnels in the U.S. are assessed to form a basis for recommendations for a new, costly facility which would provide data for modeling the hypervelocity aerodynamics envisioned for the new generation of aerospace vehicles now undergoing early studies. Attention is given to the regimes, both entry and aerodynamic, which the new vehicles will encounter, and the shortcomings of data generated for the Orbiter before flight are discussed. The features of foreign-gas, impulse, aeroballistic range, arc-heated and combustion-heated facilities are examined, noting that in any hypersonic wind tunnel the flow must be preheated to prevent liquefaction upon expansion in the test channel. The limitations of the existing facilities and the identification of the regimes which must be studied lead to a description of the characteristics of an optimum hypersonic wind tunnel, including the operations and productivity, the instrumentation, the nozzle design and the flow quality. Three different design approaches are described, each costing at least $100 million to achieve workability.

Trimmer, L. L.↗

MADE3D: Enabling the next generation of high-torque density wind generators by additive design and 3D printing

Direct-drive wind turbine generators are increasing in popularity, thanks to recent project developments—especially offshore, where reliability and efficiency are major cost drivers. Yet, high capital costs are forcing many original equipment manufacturers to consider lightweight, high-torque density generators for next-generation multi-megawatt turbines that may be difficult to realize by traditional design or manufacturing methods. In this study, we present a new design framework enabled by advanced machine learning and multimaterial additive manufacturing to perform a magnetic topology optimization that maximizes the torque per rotor active mass for a 15-megawatt direct-drive permanent magnet wind generator. A comparison of the proposed approach against conventional topology optimization demonstrated a significant increase in computational efficiency and accuracy in performance predictions. Results using single and multimaterial compositions for rotor core and magnets identify a wider choice of 3D printable designs for a given specification. A hybrid combination of sintered and dysprosium-free polymer-bonded magnets shows good potential for torque performance by saving material costs up to 8.75%. More than 30% improvement in rotor torque densities is identified which can marginally improve the overall generator torque density. With the rapid evolution of multipowder deposition technolgies, this study can greatly inspire a new paradigm for design-driven manufacturing with novel material compositions and lightweight, low-cost, high-strength multimaterial geometries that were previously unexplored for direct-drive generators.

17 WIND ENERGY↗

Shutdown characteristics of the Mod-O wind turbine with aileron controls

Horizontal-axis wind turbines utilize partial or full variable blade pitch to regulate rotor speed. The weight and costs of these systems indicated a need for alternate methods of rotor control. Aileron control is an alternative which has potential to meet this need. The NASA Lewis Research Center has been experimentally testing aileron control rotors on the Mod-U wind turbine to determine their power regulation and shutdown characteristics. Experimental and analytical shutdown test results are presented for a 38 percent chord aileron-control rotor. These results indicated that the 38 percent chord ailerons provided overspeed protection over the entire Mod-O operational windspeed range, and had a no-load equilibrium tip speed ratio of 1.9. Thus, the 38 percent chord ailerons had much improved aerodynamic braking capability when compared with the first aileron-control rotor having 20 percent chord ailerons.

Miller, D. R.↗

Smart Composite Pressure Vessels (SCPV) with Integrated Health Monitoring

The U.S. Department of Energy (DOE) is promoting and developing more energy efficient and environmentally friendly technologies that will enable America to use less petroleum. Hydrogen fuel cells – which directly convert the chemical energy in hydrogen to electricity with only water and heat as byproducts – are a very attractive solution that can enable this to happen. To date, DOE's efforts have culminated in commercial demonstration of on-board vehicular hydrogen storage systems that can allow for a driving range of greater than 300 miles. This requires storing 5 Kgs of hydrogen onboard a light vehicle. In order to store this quantity of hydrogen, the hydrogen gas needs to be stored in a composite overwrapped pressure vessel (COPV) at a very high internal pressure. The objective of the program was to demonstrate continuous and predictable health-monitoring of composite pressure vessels. A higher confidence in the operational safety of the vessels will lead to reduced burst factor of safety imposed by regulatory standards and hence will help reduce the structural wall thickness that drives the cost of the vessel. Highly optimized Type III (metal lined) and Type IV (polymer lined) COPVs that are manufactured using filament winding process have been designed and qualified for the above mentioned application. However, the main structural component of the COPVs is carbon fiber and the high cost of carbon fiber composite in a pressure vessel is a primary challenge in reducing the cost of gaseous hydrogen storage. Continuous and remote monitoring of structural health of the COPVs as well as optimization of the strength translation of carbon fibers have the potential to allow for reduced factor of safety, thereby reduced amount of carbon and associated cost of the vessel. In the current program, the project team including Steelhead Composites (SHC), University of Tennessee, Knoxville (UTK), Teijin Carbon America, Oak Ridge National Laboratory (ORNL) and LUNA designed, fabricated, and tested smart composite pressure vessels with integrated sensors. Iterative loops of design and testing using coupons, subscale STEB vessels and full size vessels proved that a new generation of high performance carbon fiber can be used for efficient design of Type 3 vessels for H2 storage. Novel analysis techniques were developed to predict the initiation and propagation of interlaminar damage inside the composite shell due to impact damage, a real threat in practical operation. Such an analysis scheme is typically not used in tank design but is an essential tool for health monitoring of composite vessels. Remote sensing of the key signatures of the tank’s operating parameters such as pressure, acceleration and humidity was demonstrated using a unique device that can wirelessly transmit and stream the data to a remote server. Fiber optic sensors were successfully integrated during fabrication of the tanks. These sensors provide a wealth of information regarding the structural health of the vessel when it is subsequently pressurized or subjected to impact damage. Excellent correlation was demonstrated between the fiber optic sensor and mechanical strain gage data, and between the measurements and analytical predictions.

08 HYDROGEN↗

Conceptual design of HTS magnets for fusion nuclear science facility

Second-generation high temperature superconductors (HTS) are available for producing >20 T at the magnet bore compared to 13–16 T for lower temperature superconducting (LTS) toroidal field magnets proposed in recent fusion energy systems studies (FESS) of Fusion Nuclear Science Facility (FNSF). HTS may enable higher fusion power density and smaller device size. High current density cables of multi-layered REBCO tapes have achieved >10 kA at 4–20 K operation in short sample tests for fusion. High current density cables are required for engineering design of FNSF to allow space for interior plasma components. High current density HTS magnets are particularly attractive in reducing the size of a fusion device, beneficial for compact tokamaks, due to their space constraints. Successful HTS magnet development may enable the design of smaller and cheaper fusion pilot plants with a mission of demonstrating net electricity. It may also offer significant cost and performance advantages in non-fusion applicants such as nuclear magnetic resonance (NMR) and magnetic resonance imaging (MRI). Furthermore, we developed HTS magnet design concepts for a compact FNSF radial build in order to define the coil size, winding pack mechanical loading and engineering requirements. Partnering with vendors in the US, PPPL is also testing high current cable prototypes aiming at enabling low cost cable technology toward 100 A/mm 2 engineering current density over the winding pack desired in high field model coil development for compact fusion pilot plants.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Opportunities and Implications for Low-Cost Hydrogen Production from Water Electrolysis in a Decarbonizing Power Sector

Increased deployment of renewable power generation such as wind and solar photovoltaics along with electrification of transportation and other sectors are driving changes in the operation and economics of the electric power sector. Simultaneously, efforts to decarbonize other sectors of the economy such as steelmaking and heavy duty transportation will require significant amounts of electricity to drive electrons to molecules processes. Hydrogen production via water splitting electrolysis is a key near-term technology for decarbonization that interfaces between the power sector and decarbonization efforts in industrial sectors. This poster examines the implications for increased deployment of water electrolyzers in a rapidly evolving energy system. The economic opportunities for low-cost hydrogen production from electrolysis that are facilitated by highly renewable grids will be examined and discussed. Durability, cost, and operational strategies for electrolyzers interacting in these future energy systems are key to enabling hydrogen at scale. This poster will overview these considerations and ongoing work within the U.S. Department of Energy’s H2NEW consortium that is focused on addressing them.

electrolysis↗

A Model-Free Frequency Control Approach for Diesel-Wind Powered Microgrids

Islanded microgrids usually consist of diesel generators and renewable energy sources (RES) to reduce the operating cost. Such microgrids have shown values for powering remote locations, but introduced unique challenges for frequency control of the grid due to the variability of renewable energy as well as the decoupled design of converter interface in RES. So, supportive control in RES becomes mandatory in such networks. This paper proposes a new dynamic control strategy, based on model-free control (MFC) approach, to support the primary frequency control of such islanded microgrids. The practical values of MFC have been discussed in various domains due to its control capability without modeling procedure and its efficient computation. In particular, we consider the diesel-wind system and the proposed MFC strategy is utilized as an online controller, which computes supplementary control signals for the rotor-side converter of the available wind turbine generators (WTGs). The calculated input signals allow WTGs to respond to frequency variations and improve the frequency response of the system. The controller is implemented and verified using the modified IEEE 33-bus full nonlinear model of the three-phase diesel-wind system in Simulink. Simulation results show the enhanced frequency response from the MFC strategy.

Park, Byungkwon↗

Onset of condensation effects in cryogenic wind tunnels

The onset of condensation effects in cryogenic wind tunnels which limits their minimum operating temperatures is examined. If this onset of effects occurs below saturation temperature, then the tunnels may be operated at the lower temperatures and additional benefits to cryogenic tunnel operation resulting in increased Reynolds number capability and reduced operating costs. Both homogeneous and heterogeneous nucleation processes are discussed as they pertain to continuous flow cryogenic wind tunnels. Examples from condensation experiments in the 0.3 m Transonic Cryogenic Tunnel are also reviewed.

Hall, R. M.↗

STOCHASTIC OPTIMAL POWER FLOW FOR REAL-TIME MANAGEMENT OF DISTRIBUTED RENEWABLE GENERATION AND DEMAND RESPONSE (Final Report)

To meet the grand challenge of a sustainable energy future, there has been a surge of interest in renewable energy. Today, the uncertainty associated with renewable resources is handled by using operating reserves. The high penetration of renewable resources, however, introduces difficult-to-control dynamics and challenges for power system operation. Decision support tools are necessary at the bulk system operational level to recognize and efficiently utilize renewable resources and distributed demand response products in concert with traditional grid resources. It is envisaged that responsive load can potentially have very significant cost advantages over either spinning or non-spinning ramping reserve. Critical decisions are made during hour(s)-ahead and real-time power system operation regarding the commitment and dispatch of generators to ensure power delivery is both reliable and economic. These decisions are typically made by a security constrained optimal flow, which determines future generator commitments, dispatches, and ensures adequate reserves are available in the event of a contingency (unexpected outage) or if future system conditions deviate from forecasts. However, security has been always based on a pre-specified subset of contingency constraints whose enforcement does not guarantee security under all possible future possibilities while also giving little or no weight to the likelihood of each contingent event or the severity of its consequences. Existing tools, which are based exclusively on deterministic optimization models, do not yield optimal operational decisions to address these new challenges, in terms of both reliability and cost-effectiveness. This project has focused on developing a stochastic optimal power flow (SOPF) framework, which integrates renewable resource uncertainty, load uncertainty, distributed storage (DS), demand response (DR) products, in a holistic manner to address the uncertainty associated with ever-increasing renewable resources, along with the inclusion of distributed demand response products in future power systems. A proof-of-concept problem was created using the Pennsylvania-Jersey-Maryland (PJM) power system network. Synthetic wind generation was added to the system to simulate 50% wind penetration. A 1-hour test of SOPF operation indicated more than 6% operational cost savings. The project continued by adding the Midwestern Independent System Operator (MISO) as a partner, with focus shifting from SOPF to Stochastic Look-Ahead Unit Commitment (SLAC). Unlike PJM, MISO is faced with significant renewable energy resources within its footprint and is challenged with substantial uncertainty in its operations. The SLAC distinguishes itself from existing tools that operators use. At best, today’s tools solve two to three cases independently, where one or two system parameters, such as forecasted load level (e.g., a low, base, and high forecast), are varied and the resulting scenarios are analyzed independently. The stochastic-based optimization of SLAC leverages statistical information from an ensemble of potential operational scenarios and their respective likelihood. The SLAC output can be translated into valuable information to the operator such as suggested commitments, optimal scheduling and dispatch of resources, reserve requirements at both locational and zonal resolutions, ramping availability and requirements, availability of demand response including operational guidance concerning the near-term and real-time coordination between distributed energy resources, and utilization of distributed storage resources. The developed SOPF/SLAC tool, a stand-alone tool compatible with existing EMSs, will provide system operators with unprecedented visibility, flexibility and predictability to these resources and operational guidance concerning the real-time coordination between DERs and DR/DS products. The game changing and practical impact of this disruptive technology will be dramatic and will usher in a new era in the electric power industry, wherein green energy concepts are fully embraced, and electric power costs are lowered throughout the nation.

42 ENGINEERING↗

A cellular glass substrate solar concentrator

The design of a second generation point focusing solar concentration is discussed. The design is based on reflective gores fabricated of thin glass mirror bonded continuously to a contoured substrate of cellular glass. The concentrator aperture and structural stiffness was optimized for minimum concentrator cost given the performance requirement of delivering 56 kWth to a 22 cm diameter receiver aperture with a direct normal insolation of 845 watts sq m and an operating wind of 50 kmph. The reflective panel, support structure, drives, foundation and instrumentation and control subsystem designs, optimized for minimum cost, are summarized. The use of cellular glass as a reflective panel substrate material is shown to offer significant weight and cost advantages compared to existing technology materials.

Bedard, R.↗