Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “cooling system”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 793 records · Page 44

Thermal Insulation for a High Temperature Molten Salt Storage Tank in a CSP Plant: Preprint

A ternary molten chloride has been suggested as a high temperature (550-720 °C) sensible heat storage medium for a two-tank system. An effective thermal insulation is proposed to provide an opportunity for the fabrication of both the hot and cold storage tanks from lower cost metals, e.g. A240-347H, by maintaining the tank wall below 500 °C. To achieve this, the hot storage tank mainly comprises of inner shell (11.4 cm of a refractory brick as liner (KX-99 ®), 30 cm of insulation brick) and outer metal shell, where 5 cm of frozen layer of PCM800 (NaCl), and 5 cm of ceramic wool fill the annular space between the shells. Another layer of ceramic wool was introduced at the outer side of the metal shell to keep the temperature lower than 60 °C. ANSYS Fluent was used for the numerical study of the cool down behavior of the system during idle period when tank is quarter-filled. The heat transfer modes were considered as radiation and natural convection heat transfer from the hot molten salt at 720 °C, conduction through the solid layers and convection heat transfer from the outer shell to the environment at 15 °C. The results showed that the proposed insulation system including a frozen layer of PCM800 maintains the temperature at the metal wall lower than 500 °C, and lower than 60 °C at the outer side of the tank. Apart from the insulation property of the frozen layer of PCM800, it absorbs any leak of hot molten salt, acting as a barrier between salt and the metal shell. The thermal performance analysis provide an insight into the benefits of the multilayer insulation.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Statistical chronometry of meteorites. I. A Test of 26 Al homogeneity and the Pb-Pb age of the solar system’s $t=0$

Here, we use rapidly cooled achondrites to test the assumption of 26 Al homogeneity in the solar nebula, by checking if there is a single value of t SS , the absolute “Pb-Pb” age of the Solar System’s t=0, that makes concordant their ages from the Al-Mg and Pb-Pb systems. We find that values t SS =4568.42 ± 0.24 Myr do make these ages concordant, and therefore the hypothesis of homogeneous 26 Al is not falsified. This age, defined to be when the solar nebula had ( 26 Al/ 27 Al) = 5.23 × 10 –5 , is significantly older than the ≈ 4567.3 Myr inferred from direct measurements of Pb-Pb ages in CAIs. Discrepancies between the Al-Mg and Pb-Pb chronometers in chondrules and CAIs have previously been interpreted as arising from heterogeneities in 26 Al, under the presumption that the Al-Mg and Pb-Pb systems in CAIs closed simultaneously. We examine this assumption and show that resetting is to be expected in CAIs. In particular, we quantitatively demonstrate that it is plausible that Pb-Pb ages of CAIs were reset at late times, without resetting the earlier Al-Mg ages, if they were transiently heated in the same manner as chondrules. We critically examine Pb-Pb isochrons, refining data and suggesting best practices for their calculation and reporting. We advocate reporting chronometry as times of formation after t=0 rather than absolute ages, as only the former is useful for astrophysical models of the solar nebula. We advocate averaging of multiple samples, rather than anchoring to individual meteorites, to improve precision.

79 ASTRONOMY AND ASTROPHYSICS↗

High Efficiency Heat Pumps Can Pave the Path for Building Decarbonization in Cold Climates: Preprint

Heat pumps play an instrumental role in buildings decarbonization strategies. Recent advances in heat pump systems employ variable-speed compressor technology and electronically commutated fan motors. Inherently, the heating capacity and efficiency of heat pumps decrease with falling outdoor temperatures. Compared to single-speed heat pumps, variable speed systems can maintain higher heating and cooling efficiencies over a wider range of outdoor temperatures. The goal of this multi-phase project was to determine the energy savings of a high efficiency, variable-speed, air-source, split system heat pump designed for cold climate applications. The first project phase was to evaluate the performance of the heat pump in the laboratory under varying outdoor conditions in heating and cooling modes. The second phase was to translate the laboratory-measured performance into lookup tables for EnergyPlus hourly building simulation engine. Then, two sets of annual building simulations were performed using typical meteorological year weather from the Chicago-O'Hare airport for three different building types (a single-family residence, a strip mall, and a low-rise office building). The first set simulated a standard efficiency heat pump while the second set utilized the phase two performance tables to model a high efficiency heat pump. The high efficiency heat pump produced significant annual heating energy savings in all three buildings. The variable speed compressor and fan control also contributed to cooling energy savings. The simulated annual energy savings ranged from 22% to 35% over their respective baseline. The project's findings helped a Midwest electric utility, Commonwealth Edison (ComEd), design new incentives around high efficiency heat pumps.

cold climate heat pump↗

First benchmarked electron cooling simulations from first principles

We present the first microscopic electron cooling simulations from first principles with accurate prediction of cooling time. These simulations were performed using our previously developed numerical method, PHAD, which is the first efficient large-scale collisional numerical method in beam physics. The simulation results are benchmarked with the experimental data of the low energy bunched electron cooling of ion beams at the storage ring CSRm at the IMP facility in China. Here, we have accurately considered the nonlinear dynamics in the whole accelerator system in addition to the electron cooling section. As a result, our simulations correctly reproduced cooling times of the experiments from first principles and without any tuning or fitting parameters in the code.

43 PARTICLE ACCELERATORS↗

The Impact of Storms on Legionella pneumophila in Cooling Tower Water, Implications for Human Health

At the U.S. Department of Energy’s Savannah River Site (SRS) in Aiken, SC, cooling tower water is routinely monitored for Legionella pneumophila concentrations using a direct fluorescent antibody (DFA) technique. Historically, 25–30 operating SRS cooling towers have varying concentrations of Legionella in all seasons of the year, with patterns that are unpredictable. Legionellosis, or Legionnaires’ disease (LD), is a pneumonia caused by Legionella bacteria that thrive both in man-made water distribution systems and natural surface waters including lakes, streams, and wet soil. Legionnaires’ disease is typically contracted by inhaling L. pneumophila , most often in aerosolized mists that contain the bacteria. At the SRS, L. pneumophila is typically found in cooling towers ranging from non-detectable up to 10 8 cells/L in cooling tower water systems. Extreme weather conditions contributed to elevations in L. pneumophila to 10 7 –10 8 cells/L in SRS cooling tower water systems in July–August 2017. L. pneumophila concentrations in Cooling Tower 785-A/2A located in SRS A-Area, stayed in the 10 8 cells/L range despite biocide addition. During this time, other SRS cooling towers did not demonstrate this L. pneumophila increase. No significant difference was observed in the mean L. pneumophila mean concentrations for the towers ( p < 0.05). There was a significant variance observed in the 285-2A/A Tower L. pneumophila results ( p < 0.05). Looking to see if we could find “effects” led to model development by analyzing 13 months of water chemistry and microbial data for the main factors influencing the L. pneumophila concentrations in five cooling towers for this year. It indicated chlorine and dissolved oxygen had a significant impact ( p < 0.0002) on cooling tower 785A/2A. Thus, while the variation in the log count data for the A-area tower is statistically greater than that of the other four towers, the average of the log count data for the A-Area tower was in line with that of the other towers. It was also observed that the location of 785A/2A and basin resulted in more debris entering the system during storm events. Our results suggest that future analyses should evaluate the impact of environmental conditions and cooling tower design on L. pneumophila water concentrations and human health.

54 ENVIRONMENTAL SCIENCES↗

Grid Value Analysis of Geothermal Systems for End-Use Applications

Fuel based end-uses for residential, commercial, and industrial consumers require a technology change to achieve economy-wide decarbonization. Space heating accounts for 42% of residential and 32% of commercial energy demand, much of which is currently met through carbon emitting fuels. Industrial energy use is heavily fuel based with electricity currently representing 13% of energy demand. Geothermal heat pumps (GHPs) and geothermal direct use can eliminate the need for CO2 emitting and simultaneously allow for more efficient electrification of end uses. Past work has assessed the impact on total energy costs and generation investments but did not identify specific grid services benefited. Energy usage in residential and commercial structures was assessed by leveraging data from ComStock and ResStock models. These models utilize housing attributes, occupancy patterns, weather data, and sophisticated energy simulations to generate hourly load profiles for individual buildings identified by unique IDs associated with their locations. Industrial sector energy use was evaluated using information from the Manufacturing Energy Consumption Survey (MECS) as well as plant utilization data from the US Census to estimate hourly plant operations. The change in end-use demand for electricity, natural gas, and other fuels was calculated for different technologies that could meet this need. Using the ReEDS capacity expansion model, we produce regional price profiles that capture the grid benefit associated with the amount and timing of energy shifts in the power system from the adoption of geothermal systems relative to other technologies that could meet space heating, space cooling, and process heat requirements. We find that geothermal systems for meeting end-use demand add value to the energy system. In buildings where geothermal systems increase grid costs, these values are offset by reduced fuel costs and benefits to externalities, including emissions and health impacts.

decarbonization↗

A Hydrokinetic Energy Conversion System using Underwater LLC-type Resonant Converter

The hydrokinetic energy of river and ocean currents is a valuable renewable energy resource. Conventional systems for harvesting hydrokinetic energy usually have bulky passive components, lengthy cables connecting the underwater turbine/generator with onshore power converters, and limited control over power generation. This paper presents a new hydrokinetic energy harvesting system using an LLC-type resonant converter that is placed underwater in close proximity to the generator. By using SiC devices and the soft switching characteristic of LLC resonant converter, the converter operates in 10s of kHz, significantly reducing the passive components. In addition, the LLC converter provides flexible power regulation of the system. Furthermore, the underwater placement of the power converter takes advantage of the cooling provided by the water and simplifies the system by reducing its connecting cable length.

Dai, Hang↗

Niowave Ancillary Systems – FY21: In Partial Fulfillment of the Deliverable Requirement for Niowave Ancillary Systems Support by LANL

Niowave Inc. produces medical radioisotopes within the US. Lead-bismuth eutectic (LBE) is irradiated using an electron beam to produce neutrons that are used in the production of Molybdenum-99 (Mo-99). The medical community relies on a steady supply of Mo-99 which is primarily used in medical diagnostic imaging. The irradiation of LBE results in high temperatures within the molten metal, this work focusses on the design of ancillary systems associated with the liquid metal system. The LBE is initially at a temperature of 200°C and flows over a steel plate to create a waterfall. The electron beam is then aimed at the waterfall to generate neutrons. The peak temperatures of the LBE post irradiation depend on the beam energy of the LINAC. For a 15 MeV and 20 kW beam, the temperatures can range between 300°C and 350°C. The LBE is cycled through the system to create a closed loop that requires the post-irradiation LBE to be cooled back to 200°C. This work focuses on the heat exchanger and condenser system responsible for the cooling of the post-irradiation LBE.

36 MATERIALS SCIENCE↗

Micro environmental control system

A micro environmental control system that can remove or add 30W from or to the near range personal microenvironment of a user. For cooling, the μX uses a micro vapor compression system during the un-occupied period to freeze a phase-change-material in a thermal storage module. A fan then moves air over the phase-change-material to deliver cooled air. Heating is delivered by a small electric heater integrated into a condensing unit. The resulting system is inexpensive to build and uses a limited amount of energy.

42 ENGINEERING↗

Kinetics of amorphous defect phases measured through ultrafast nanocalorimetry

Recognition of the role of extended defects on local phase transitions has led to the conceptualization of the defect phase, localized thermodynamically stable interfacial states that have since been applied in a myriad of material systems to realize significant enhancements in material properties. Here, we explore the kinetics of grain boundary confined amorphous defect phases, utilizing the high temperature and scanning rates afforded by ultrafast differential scanning calorimetry to apply targeted annealing/quenching treatments at high rates capable of capturing the kinetic behavior. Four Al-based nanocrystalline alloys, including two binary systems, Al–Ni and Al–Y, and two ternary systems, Al–Mg–Y and Al–Ni–Y, are selected to probe the materials design space (enthalpy of mixing, enthalpy of segregation, chemical complexity) for amorphous defect phase formation and stability, with correlative transmission electron microscopy applied to link phase evolution and grain stability to nanocalorimetry signatures. A series of targeted isothermal annealing heat treatments is utilized to construct a Time–Temperature-Transformation curve for the Al–Ni system, from which a critical cooling rate of 2400 °C/s was determined for the grain boundary confined disordered-to-ordered transition. Finally, a thermal profile consisting of 1000 repeated annealing sequences was created to quantify the recovery of the amorphous defect phase following sequential annealing treatments, with results indicating remarkable microstructural stability after annealing at temperatures above 90% of the melting temperature. This work contributes to a deeper understanding of grain boundary localized thermodynamics and kinetics, with potential implications for the design and optimization of advanced materials with enhanced stability and performance.

Amorphous defect phases↗

Metamagnetism and kinetic arrest in a long-range ferromagnetically ordered multicaloric double perovskite Y 2 CoMnO 6

A systematic magnetic study of the double perovskite oxide Y 2 CoMnO 6 (YCMO) has been performed. A monoclinic P21/n phase of YCMO was synthesized using a sol-gel method. Neutron diffraction (ND) measurements evidence the onset of long-range ferromagnetic (FM) ordering at TC ~ 76 K, which persists down to 5 K. The presence of 25% antisite disorder, estimated from the ND data, leads to the appearance of short-range antiferromagnetic (AFM) interactions. The existence of thermal hysteresis due to competing interactions between FM and AFM phases is observed in the M vs. T measurements. The pinning of magnetic domain walls at the Co/Mn antiphase boundaries results in a metamagnetic-like behavior. The field dependence of thermomagnetic irreversibility and the nature of virgin curves indicate the occurrence of a kinetic arrest phenomenon, which is further verified via cooling and heating of the system in an unequal fields (CHUF) protocol. In full agreement with the ND data, a detailed analysis of critical exponents near the paramagnetic (PM)-FM phase transition also establishes YCMO as a long-range interacting mean-field system. A close examination of the temperature- and field-dependent magnetic entropy change yields an in-depth understanding of coexisting magnetically ordered and disordered phases in YCMO, leading to a comprehensive magnetic phase diagram of this multifunctional double perovskite system.

36 MATERIALS SCIENCE↗

Numerical study of multi-component flow and mixing in a scaled fission product venting system

Numerical simulation of isothermal multi-component gas flow was conducted to study fluid flow and mixing in a scaled low-pressure, low-temperature test facility for the fission product venting system (FPVS) of a gas cooled fast reactor (GFR). The geometry of FPVS test facility was an open loop including gradual expansion coupling and two 90°pipe elbows. First, the validation of large eddy simulation (LES) wall-adapting local eddy-viscosity (WALE) turbulent model was performed for transitional flow in a circular pipe with gradual expansion. The reactingFOAM solver in OpenFOAM v8 was employed. By introducing appropriate turbulence disturbance at the flow inlet, such as turbulence intensity, the numerical results showed good agreement in (1) the velocity profile downstream of the pipe expansion measured by particle image velocimetry (PIV) in this study, and (2) the reattachment length reported in the literature. Using this validated model, the numerical simulation of flow and component mixing was performed for the FPVS with an inlet flowrate corresponding to a Reynolds number of 2,400 to investigate the flow behavior and component mixing. Standard deviation of the mass fraction of component, referred to as absolute mixing index (AMI), was calculated to quantify the mixing of components, showing that the component mixing length determined by AMI is related to the reattachment length downstream of the expansion. Additionally, this study was able to identify the best location in the FPVS test facility to measure the velocity and concentration profies where multicomponent flow is well mixed.

15 GEOTHERMAL ENERGY↗

Commissioning plan for LCLS II 2 K cold box

Commissioning of the LCLS II cryogenic plant has been planned with respect to electrical and mechanical systems checkout, equipment cleanup, cool-down, and individual performance evaluation. This plant consists of warm and cold storage, helium compressors, 4.5 K and 2 K cold boxes, and all auxiliaries typical for helium refrigeration processes. The 2 K cold box, consisting of five cold compressors in series to produce the flow and pressures necessary for 2K operation, will be the last equipment installed and, along with an additional 10,000 L helium dewar, will allow the entire plant to be commissioned as a single entity. The pre-commissioning stages, commissioning plan for 2 K cold box without connecting to the LCLS II LINAC, additional test equipment needed to simulate the loads, all process studies and associated results are described herein.

36 MATERIALS SCIENCE↗

Sodium Hydrogen Sensor and Acoustic Flow Sensor Development

This report documents the development of diffusion-type hydrogen meters (DTHMs) as part of a steam generator leak detection system (SGLDS) of sodium-cooled fast reactors (SFR) and the demonstration of the capabilities of acoustic flowmeters, including a commercial UTFM (Flexim FLUXUS F721) and an Argonne HT acoustic flowmeter running on shear-to-longitudinal mode. It also evaluates two Argonne permanent magnet flowmeters (PMFMs).

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Gear Test Assembly – Experimental Testing and Gear Analysis (FY2021 Year End Report)

The Gear Test Assembly (GTA) is an experimental apparatus designed to test mechanical components used in fuel handling systems of liquid-sodium cooled fast-spectrum nuclear reactors. The performance and lifetime of gears, bearings, and dynamic seals are the primary focus of study. Three experimental campaigns have been completed since the start of operation in 2019, and the GTA is currently assembled and ready to begin the fourth experimental campaign. Sodium operations at the Mechanisms Engineering Test Loop (METL) have been paused while repairs are made to the Building 308 Alkali Metal Scrubber. This work is nearly complete, and once METL is brought back into operation the GTA will begin sodium testing immediately.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Submersible Multistage Centrifugal Pump for Versatile Test Reactor Cartridge Test Loop

Submersible multistage centrifugal pumps are ideal for pumping in narrow confined spaces and achieving necessary head pressures and flow rates. Once a diameter is determined then manipulation of the number of stages and motor speed are all that are required to meet desired flow conditions. The Versatile Test Reactor (VTR) closed loop cartridge systems will need forced convection cooling independent of the main reactor. A multistage centrifugal pump can meet the necessary flow rates and pumping pressures while minimizing space taken. The pump considered for this work was based off a deep well submersible pump, a variation of a multistage centrifugal pump. We experimented with two pump sizes, 5 cm (2 inch) and 7.5 cm (3 inch) diameters. These diameters were chosen to fit into the inner diameter of standard 5 and 7.5 (2 and 3 inch) Schedule 40 pipe, respectively. This made the design for the test loop both simpler and less expensive as the need for an engineered pump housing was eliminated. Initial test cartridge planning indicated space for only a 5 cm (2 inch) diameter pump, though early testing of this size showed the need for an abnormally high-speed and high-power motor. Fine tuning of the cartridge design allowed a pump size increase to 7.5 cm (3 inches), which was the pump size most extensively tested in this work. The test loop is composed of various sizes of PVC and aluminum piping components in a loop configuration. The pump is driven by a Pittman 250 W (1/3 horsepower) electric motor with maximum speed of 3,450 RPM. Testing consisted of running the pump at a constant motor speed while varying a control valve to restrict flow through the loop, with differential pressure and flow rate recorded. This was done for one and two stage configurations for the 5 cm (2 inch) diameter impeller design and one, two, and three stage configurations for the 7.5 cm (3 inch diameter) impeller design, respectively. Due to pumping power requirements, two and three stage 7.5 cm (3 inch) diameter impeller testing at higher flowrates lowered the motor speed substantially. In regions where motor speed could not be maintained constant, the data were discarded. The test loop was also reconfigured to allow for the pump to be tested for pressure drop in a stalled or inoperable (0 RPM) flow condition. Demonstration of adequate natural convection cooling of the test cartridge fuel type is necessary under accident conditions, and this will depend upon the flow resistance through the impeller assembly when the pump is not operating. Thus, accurate knowledge of the effective impeller assembly loss coefficient is important for safety evaluations. The test loop was modified to provide water inlet and outlets on either side of the pump impeller stack, and a metered flow of lab water was provided in order to measure the pressure drop across the cartridges as a function of flowrate. Data from the pump head curve testing developed as part of this work and supported by analysis using pump head affinity laws indicates that a three stage 7.5 cm (3 inch) pump impeller design will meet target requirements for coolant flow within the VTR cartridge sodium cartridge at full power conditions [1] with margin; this corresponds to a flowrate of 45 l/min (12 gpm) at a pressure drop of 6.1 m (20 feet) of water head. The results of the pressure loss measurements across the impeller assembly when the pump is stationary (i.e., at 0 RPM) indicate that the pressure loss coefficient is 0.921 for a two impeller stack configuration; this value is calculated based on the flow velocity through the minimum available flow area within a single stage of the impeller which corresponds to 1.4 cm2.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Modeling Framework for Data Center

This chapter highlights the critical need for advanced modeling of data centers due to their rapidly increasing energy consumption and impact on grid reliability. Driven by the demand for AI applications, data centers are projected to consume a significant portion of US energy by 2028, putting stress on an already challenged power grid. The chapter emphasizes the importance of "fast" time-scale models to understand the dynamic interactions between data centers and the grid, especially given the rapid power fluctuations of AI workloads. It outlines a modeling framework that includes both offline and real-time EMT domain simulations, detailing the necessary representations for various components like utility interfaces, transformers, IT loads, UPS, cooling loads, Battery Energy Storage Systems (BESS), generators, protection systems, and higher-level control systems. While standard simulation tools like PSCAD offer basic models, custom development is often required to accurately capture the unique and fast-changing behaviors of modern data centers. The chapter also discusses key metrics and test cases for validating these models, focusing on transient load responses, protection relay coordination, and demand flexibility. Finally, it addresses the challenges of modeling large-scale data centers, such as computational complexity and the trade-off between model fidelity and practicality, suggesting hybrid modeling approaches as a solution. The overarching goal is to create a robust framework that helps assess data center impacts on grid stability, identify vulnerabilities, and inform the development of standards for reliable integration of these large loads into the bulk power system.

25 ENERGY STORAGE↗