Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “coherence imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 793 records · Page 44

Diffraction image formation in optical systems with polarization aberrations. I - Formulation and example

This paper is the first in a series that will examine image formation in optical systems with polarization aberrations. The present paper derives the point-spread function (PSF) and the optical transfer function for optical systems with polarization aberration and explores how image formation depends on the coherence and polarization state of the source. It is shown that the scalar PSF of Fourier optics can be generalized in the presence of polarization aberration to a 4 x 4 point-spread matrix (PSM) in Mueller matrix notation. A similar 4 x 4 optical transfer matrix (OTM) is shown to be an appropriate generalization of the optical transfer function. The PSM and the OTM are associated with the optical system and are independent of the incident polarization state but dependent on the coherence of the illumination. Since an optical system with polarization aberrations will have a different PSF and optical transfer function for different incident polarization states, the PSM and the OTM act as filters with regard to the incident polarization state. Example calculations are performed for a circularly retarding lens.

Mcguire, James P., Jr.↗

Large area QNDE inspection for airframe integrity

Quantitative Nondestructive Evaluation (QNDE) technology is being developed to provide new options for cost effective inspection of airframes. An R&D effort based on five NDE technologies is addressing questions of structural bonding assessment, corrosion detection, multisite damage detection, and fatigue characterization. The research/applications are being conducted by prioritized focussing and staging of the following technologies: (1) thermal NDE; (2) ultrasonic NDE; (3) coherent optical NDE; (4) magnetic imaging NDE; and (5) radiographic NDE. The focus here is on the most recent applications of thermal NDE technology to large area inspection of lap-joint and stiffener bonds. The approach is based on pulsed radiant heating of the airframe and measurement of the surface temperature of the structure with an infrared imager. Several advantages of the technique are that it is noncontacting, inspects one square meter area in a period of less than 2 minutes and has no difficulty inspecting typical curvatures of the fuselage. Numerical models of heat flow in these geometries are used to determine appropriate techniques for reduction of the infrared images, thereby delineating regions of disbonds. These models are also used to determine the optimum heating and measurement times for maximizing the contrast between bonded and unbonded structures. Good agreement is found between these results and experimental measurements, and a comparison of the two are presented. Also presented are results of measurements on samples with fabricated defects which show the technique is able to clearly indicate regions of disbonds. Measurements on an airframe also clearly image subsurface structure.

Winfree, William P.↗

Interocular velocity difference contributes to stereomotion speed perception

Two experiments are presented assessing the contributions of the rate of change of disparity (CD) and interocular velocity difference (IOVD) cues to stereomotion speed perception. Using a two-interval forced-choice paradigm, the perceived speed of directly approaching and receding stereomotion and of monocular lateral motion in random dot stereogram (RDS) targets was measured. Prior adaptation using dysjunctively moving random dot stimuli induced a velocity aftereffect (VAE). The degree of interocular correlation in the adapting images was manipulated to assess the effectiveness of each cue. While correlated adaptation involved a conventional RDS stimulus, containing both IOVD and CD cues, uncorrelated adaptation featured an independent dot array in each monocular half-image, and hence lacked a coherent disparity signal. Adaptation produced a larger VAE for stereomotion than for monocular lateral motion, implying effects at neural sites beyond that of binocular combination. For motion passing through the horopter, correlated and uncorrelated adaptation stimuli produced equivalent stereomotion VAEs. The possibility that these results were due to the adaptation of a CD mechanism through random matches in the uncorrelated stimulus was discounted in a control experiment. Here both simultaneous and sequential adaptation of left and right eyes produced similar stereomotion VAEs. Motion at uncrossed disparities was also affected by both correlated and uncorrelated adaptation stimuli, but showed a significantly greater VAE in response to the former. These results show that (1) there are two separate, specialised mechanisms for encoding stereomotion: one through IOVD, the other through CD; (2) the IOVD cue dominates the perception of stereomotion speed for stimuli passing through the horopter; and (3) at a disparity pedestal both the IOVD and the CD cues have a significant influence.

Vision, Binocular/physiology↗

Evaluation of Tablet-Based Methods for Assessment of Contrast Sensitivity

Some astronauts have suffered degradation of vision during long-duration space flight, suffering from a condition that has come to be known as Spaceflight Associated Neuro-ocular Syndrome (SANS). While related morphological changes can be observed with imaging technologies such as optical coherence tomography (OCT), it may be useful to have a rapid method for functional vision assessment. In this paper, we compare three tablet-based methods for rapid assessment of contrast sensitivity. First, a relatively novel method developed expressly for touch screens, in which the subject ”swipes” a frequency/contrast sweep grating to indicate the boundary between visible and invisible patterns; second, a method-of-adjustment task in which the subject adjusts the contrast of a grating patch up and down to bracket the visual threshold; and third, a traditional temporal two-alternative forced choice (2AFC) task, in which the subject is presented with a near-threshold stimulus in one of two intervals, and must report the interval containing the stimulus. The swipe method shows variability comparable to the 2AFC method, and shows good agreement in estimates of the spatial frequency of peak sensitivity. The absolute sensitivity estimated with the swipe method is higher than that of the other methods, perhaps because subjects are biased to trace outside of the visible pattern region, or perhaps due to stimulus differences.

Mulligan, Jeffrey B.↗

Viewing-angle effects in radar images

A quantitative determination of the effect of viewing angle on the detectability of topographic linears in radar imagery is presented. Variations of azimuth and aspect angles of an imaging radar antenna relative to a topographic linear were simulated using low-angle illumination of controlled linear features on polystyrene sheets. The several model surfaces represented idealized versions of surface types that may be expected in areas of geologic interest. Fourier transform spectra of the radar image simulations were obtained using a coherent-optics system. These spectra were found to correlate with a detectability factor obtained directly from the radar image simulations. Fourier transform spectra of a linear feature observed from multiple viewing angles by a K-band imaging radar were also obtained and a detectability factor was estimated which agreed closely with theoretical predictions.

Eppes, T. A.↗

A theoretical study on phase-contrast mammography with Thomson-scattering x-ray sources

Purpose: The x-ray transmitted beam from any material/tissue depends on the complex refractive index (n=1-{delta}+i{beta}), where {delta} is responsible for the phase shift and {beta} is for the beam attenuation. Although for human tissues, the {delta} cross section is about 1000 times greater than the {beta} ones in the x-ray energy range from 10 to 150 keV, the gain in breast tumor visualization of phase-contrast mammography (PCM) with respect to absorption contact imaging (AI) is limited by the maximum dose that can be delivered to the patient. Moreover, in-line PC imaging (PCI) is the simplest experimental mode among all available x-ray PCI techniques since no optics are needed. The latter is a fundamental requirement in order to transfer the results of laboratory research into hospitals. Alternative to synchrotron radiation sources, the implementation of relativistic Thomson-scattering (TS) x-ray sources is particularly suitable for hospital use because of their high peak brightness within a relatively compact and affordable system. In this work, the possibility to realize PCM using a TS source in a hospital environment is studied, accounting for the effect of a finite deliverable dose on the PC visibility enhancement with respect to AI. Methods: The contrast-to-noise ratio of tumor-tissue lesions in PCM has been studied on the bases of a recent theoretical model, describing image contrast formation by means of both wave-optical theory and the mutual coherence formalism. The latter is used to describe the evolution, during wave propagation, of the coherence of the wave field emitted by a TS source. The contrast-to-noise ratio for both PCI and AI has been analyzed in terms of tumor size, beam energy, detector, and source distances, studying optimal conditions for performing PCM. Regarding other relevant factors which could influence ''tumor'' visibility, the authors have assumed simplified conditions such as a spherical shape description of the tumor inclusion, a constant surrounding background, ideal conditions for the calculus of the contrast-to-noise ratio. Results: The results show the possibility to enhance with PCI the signal-to-noise ratio for features in the submillimeter scale. This finding could give PCM a great advantage with respect to AI, opening the possibility to decrease the number of wrong diagnoses before histological exams. The results agree with experimental evidences obtained by Dreossi et al.[D. Dreossi et al., ''The mammography project at the SYRMEP beamline,'' Eur. J. Radiol. 68, S58-S62 (2008)] with real PCM using synchrotron radiation. Conclusions: The challenging characteristics of TS sources, suitable for PCM, should be fluxes of at least 10{sup 11} photons/s emitted by very small sources of about 10 {mu}m, together with moderate energy spreads (less than 10%) in order to realize both sufficient spatial coherence and enough fluence on the patient, collecting images in reasonable exposure times. These fluxes will be achieved by next generation TS sources which are already under development.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Synthetic aperture radar target detection, feature extraction, and image formation techniques

This report presents new algorithms for target detection, feature extraction, and image formation with the synthetic aperture radar (SAR) technology. For target detection, we consider target detection with SAR and coherent subtraction. We also study how the image false alarm rates are related to the target template false alarm rates when target templates are used for target detection. For feature extraction from SAR images, we present a computationally efficient eigenstructure-based 2D-MODE algorithm for two-dimensional frequency estimation. For SAR image formation, we present a robust parametric data model for estimating high resolution range signatures of radar targets and for forming high resolution SAR images.

Li, Jian↗

Lasing from Finite Plasmonic Nanoparticle Lattices

Small lasers can generate coherent light for integrated photonics, in-vivo cellular imaging, and solid-state lighting. Unlike conventional lasers, plasmonic lasers can generate coherent light at sub-wavelength scales, although cavity architectures based on metal films and semiconducting gain exhibit large radiative losses and lack directional emission. In contrast, two-dimensional (2D) metal nanoparticle arrays surrounded by organic dyes can support lasing with high directionality at room temperature. Yet, the relationship between the number of nanoparticles in a finite lattice and their lasing emission characteristics is unknown. Here we show that the number of units in 2D gold nanoparticle lattices is critical to generate robust cavity resonances and lasing emission. Narrower lattice plasmons associated with stronger electromagnetic near fields are observed as nanoparticle number increases. Experimentally, we demonstrate lasing from a 30x30 nanoparticle lattice. Semi-quantum modeling indicates lower lasing thresholds and faster population inversion dynamics with higher nanoparticle numbers. These findings indicate that finite lattices of nanoparticles integrated with gain can function as independent, coherent light sources for optical multiplexing and lab-on-a-chip applications.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Perfection of Apoferritin Crystals: An Advanced X-Ray Imaging and Diffraction Study

Ferritin is a well-known iron-storage protein, and is a spherical shell that consists of 24 identical subunits packed in a 432 symmetry. The typically large protein size and its distinction from lysozyme as to chemical and physical characteristics make ferritin an attractive model protein for crystal growth and perfection investigation-as an alternative to the most widely studied lysozyme. In this contribution, the latest results obtained from coherence-based x-ray diffraction imaging and diffraction experiments will be presented on octahedral apoferritin (a demetalized form of ferritin) crystals grown from various growth conditions. Crystal specimens, which have the measured rocking-curve widths varying from a few arcseconds to several tens arcseconds (or more), are comparatively examined by intrinsically highly sensitive mapping of lattice perfection and defects. The richness of the observed defects and growth features offers insight into perfection and growth of protein crystals. Beautiful interference fringe patterns formed in diffraction images and fine oscillation structure of rocking curves observed will be discussed for understanding of physical origins and the underlying impact.

Hu, Z. W.↗

Characterization of a bent Laue double-crystal beam-expanding monochromator

A bent Laue double-crystal monochromator system has been designed for vertically expanding the X-ray beam at the Canadian Light Source's BioMedical Imaging and Therapy beamlines. Expansion by a factor of 12 has been achieved without deteriorating the transverse coherence of the beam, allowing phase-based imaging techniques to be performed with high flux and a large field of view. However, preliminary studies revealed a lack of uniformity in the beam, presumed to be caused by imperfect bending of the silicon crystal wafers used in the system. Results from finite-element analysis of the system predicted that the second crystal would be most severely affected and has been shown experimentally. It has been determined that the majority of the distortion occurs in the second crystal and is likely caused by an imperfection in the surface of the bending frame. Here, measurements were then taken to characterize the bending of the crystal using both mechanical and diffraction techniques. In particular, two techniques commonly used to map dislocations in crystal structures have been adapted to map local curvature of the bent crystals. One of these, a variation of Berg–Berrett topography, has been used to quantify the diffraction effects caused by the distortion of the crystal wafer. This technique produces a global mapping of the deviation of the diffraction angle relative to a perfect cylinder. Finally, this information is critical for improving bending and measuring tolerances of imperfections by correlating this mapping to areas of missing intensity in the beam.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A software-based system which produces SEASAT SAR imagery

A digital processing algorithm and its associated system design for producing images from SEASAT synthetic aperture radar (SAR) data is described. The proposed system uses the fast Fourier transform approach to perform the two dimensional correlation process. The range migration problem can be alleviated by approximating the locus of echoes from a point target by several linear segments. Data corresponding to each segment are correlated separately and the results are coherently summed to produce full resolution images. This processing approach exhibits high computation efficiency and simple processing control functions. It is particularly attractive for software implementation based on general purpose computers. Results of this implementation and examples of digitally correlated SEASAT SAR imagery are discussed.

Wu, C.↗

Conditional guided generative diffusion for particle accelerator beam diagnostics

Abstract Advanced accelerator-based light sources such as free electron lasers (FEL) accelerate highly relativistic electron beams to generate incredibly short (10s of femtoseconds) coherent flashes of light for dynamic imaging, whose brightness exceeds that of traditional synchrotron-based light sources by orders of magnitude. FEL operation requires precise control of the shape and energy of the extremely short electron bunches whose characteristics directly translate into the properties of the produced light. Control of short intense beams is difficult due to beam characteristics drifting with time and complex collective effects such as space charge and coherent synchrotron radiation. Detailed diagnostics of beam properties are therefore essential for precise beam control. Such measurements typically rely on a destructive approach based on a combination of a transverse deflecting resonant cavity followed by a dipole magnet in order to measure a beam’s 2D time vs energy longitudinal phase-space distribution. In this paper, we develop a non-invasive virtual diagnostic of an electron beam’s longitudinal phase space at megapixel resolution (1024 × 1024) based on a generative conditional diffusion model. We demonstrate the model’s generative ability on experimental data from the European X-ray FEL.

43 PARTICLE ACCELERATORS↗

Small mover target detection in synthetic aperture radar imagery

The various technologies presented herein relate to detecting small moving entities or targets in radar imagery. Two SAR images can be captured for a common scene, wherein the scene is imaged twice from the same flight path. The first image is captured at a first instance and the second image is captured at a second instance, and differences between the two images are determined using a complex SAR change measure, excess coherency factor or DeltaC, based in part upon quantification of incoherent (or magnitude) change between the two images. A plurality of operations are performed to enable extraction of coherent change measures relating to the small moving entities from measures relating to large objects, stationary reflective structures, radar focusing artifacts, etc.

Simonson, Katherine M.↗

X-ray nano-holotomography reconstruction with simultaneous probe retrieval

In conventional tomographic reconstruction, the pre-processing step includes flat-field correction, where each sample projection on the detector is divided by a reference image taken without the sample. When using coherent X-rays as a probe, this approach overlooks the phase component of the illumination field (probe), leading to artifacts in phase-retrieved projection images, which are then propagated to the reconstructed 3D sample representation. The problem intensifies in nano-holotomography with focusing optics, which, due to various imperfections creates high-frequency components in the probe function. Here, we present a new iterative reconstruction scheme for holotomography, simultaneously retrieving the complex-valued probe function. Implemented on GPUs, this algorithm results in 3D reconstruction resolving twice thinner layers in a 3D ALD standard sample measured using nano-holotomography.

Nikitin, Viktor↗

Quantitative phase reconstruction from input-output intensities using a shift-invariant linear imaging system

We formulate an iteration scheme for quantitative two-dimensional phase retrieval of complex scalar wave fields from input-output intensity profiles using a coherent rotationally symmetric shift-invariant linear optical imaging system. This method is a generalization of our previous method for quantitative single-image pure phase reconstruction using an imperfect shift-invariant linear imaging system. The method is somewhat analogous to the Gerchberg-Saxton iterative phase-retrieval algorithm, but typically converges much more rapidly. We have demonstrated the efficacy of the method using simulated data in the presence of noise.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Prototype Optical Correlator For Robotic Vision System

Known and unknown images fed in electronically at high speed. Optical correlator and associated electronic circuitry developed for vision system of robotic vehicle. System recognizes features of landscape by optical correlation between input image of scene viewed by video camera on robot and stored reference image. Optical configuration is Vander Lugt correlator, in which Fourier transform of scene formed in coherent light and spatially modulated by hologram of reference image to obtain correlation.

Scholl, Marija S.↗

Time-stretch microscopy based on time-wavelength sequence reconstruction from wideband incoherent source

Time-stretch microscopy has emerged as an ultrafast optical imaging concept offering the unprecedented combination of the imaging speed and sensitivity. However, dedicated wideband and coherence optical pulse source with high shot-to-shot stability has been mandated for time-wavelength mapping—the enabling process for ultrahigh speed wavelength-encoded image retrieval. From the practical point of view, exploiting methods to relax the stringent requirements (e.g., temporal stability and coherence) for the source of time-stretch microscopy is thus of great value. In this paper, we demonstrated time-stretch microscopy by reconstructing the time-wavelength mapping sequence from a wideband incoherent source. Utilizing the time-lens focusing mechanism mediated by a narrow-band pulse source, this approach allows generation of a wideband incoherent source, with the spectral efficiency enhanced by a factor of 18. As a proof-of-principle demonstration, time-stretch imaging with the scan rate as high as MHz and diffraction-limited resolution is achieved based on the wideband incoherent source. We note that the concept of time-wavelength sequence reconstruction from wideband incoherent source can also be generalized to any high-speed optical real-time measurements, where wavelength is acted as the information carrier.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗