Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “central receiver”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 793 records · Page 44

Sequencing of Local Therapy Affects the Pattern of Treatment Failure and Survival in Children With Atypical Teratoid Rhabdoid Tumors of the Central Nervous System

Purpose: To assess the pattern of treatment failure associated with current therapeutic paradigms for childhood atypical teratoid rhabdoid tumors (AT/RT). Methods and Materials: Pediatric patients with AT/RT of the central nervous system treated at our institution between 1987 and 2007 were retrospectively evaluated. Overall survival (OS), progression-free survival, and cumulative incidence of local failure were correlated with age, sex, tumor location, extent of disease, and extent of surgical resection. Radiotherapy (RT) sequencing, chemotherapy, dose, timing, and volume administered after resection were also evaluated. Results: Thirty-one patients at a median age of 2.3 years at diagnosis (range, 0.45-16.87 years) were enrolled into protocols that included risk- and age-stratified RT. Craniospinal irradiation with focal tumor bed boost (median dose, 54 Gy) was administered to 18 patients. Gross total resection was achieved in 16. Ten patients presented with metastases at diagnosis. RT was delayed more than 3 months in 20 patients and between 1 and 3 months in 4; 7 patients received immediate postoperative irradiation preceding high-dose alkylator-based chemotherapy. At a median follow-up of 48 months, the cumulative incidence of local treatment failure was 37.5% {+-} 9%; progression-free survival was 33.2% {+-} 10%; and OS was 53.5% {+-} 10%. Children receiving delayed RT ({>=}1 month postoperatively) were more likely to experience local failure (hazard ratio [HR] 1.23, p = 0.007); the development of distant metastases before RT increased the risk of progression (HR 3.49, p = 0.006); and any evidence of disease progressionbefore RT decreased OS (HR 20.78, p = 0.004). Disease progression occurred in 52% (11/21) of children with initially localized tumors who underwent gross total resection, and the progression rate increased proportionally with increasing delay from surgery to RT. Conclusions: Delayed RT is associated with a higher rate of local and metastatic disease progression in children with AT/RT. Current treatment regimens for pediatric patients with AT/RT are distinctly age stratified; novel protocols investigating RT volumes and sequencing are needed.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SIMULATING X-RAY SUPERCAVITIES AND THEIR IMPACT ON GALAXY CLUSTERS

Recent X-ray observations of hot gas in the galaxy cluster MS 0735.6+7421 reveal huge radio-bright, quasi-bipolar X-ray cavities having a total energy {approx}10{sup 62} erg, the most energetic active galactic nucleus (AGN) outburst currently known. We investigate the evolution of this outburst with two-dimensional axisymmetric gas dynamical calculations in which the cavities are inflated by relativistic cosmic rays (CRs). Many key observational features of the cavities and associated shocks are successfully reproduced. The radial elongation of the cavities indicates that CRs were injected into the cluster gas by a (jet) source moving out from the central AGN. AGN jets of this magnitude must be almost perfectly identically bipolar. The relativistic momentum of a single jet would cause a central AGN black hole of mass 10{sup 9} M{sub sun} to recoil at {approx}6000 km s{sup -1}, exceeding kick velocities during black hole mergers, and be ejected from the cluster-center galaxy. Observed deviations from bipolar symmetry in the radio cavities can be caused by subsonic flows in the ambient cluster gas, but reflection shocks between symmetric cavities are likely to be visible in deep X-ray images. When the cavity inflation is complete, 4PV underestimates the total energy received by the cluster gas. Deviations of the cluster gas from hydrostatic equilibrium are most pronounced during the early cavity evolution when the integrated cluster mass found from the observed gas pressure gradient can have systematic errors near the cavities of {approx}10%-30%. The creation of the cavity with CRs generates a long-lasting global cluster expansion that reduces the total gas thermal energy below that received from the cavity shock-even this most energetic AGN event has a net cooling effect on cluster gas. One gigayear after this single outburst, a gas mass of {approx}6 x 10{sup 11} M{sub sun} is transported out beyond a cluster radius of 500 kpc. Such post-cavity outflows can naturally produce the discrepancy observed between the cluster gas mass fraction and the universal baryon fraction inferred from Wilkinson Microwave Anisotropy Probe observations.

79 ASTRONOMY AND ASTROPHYSICS↗

Integrated tests of a high speed VXS switch card and 250 MSPS flash ADCs

High trigger rate nuclear physics experiments proposed for the 12 GeV upgrade at the Thomas Jefferson National Accelerator Facility create a need for new high speed digital systems for energy summing. Signals from electronic detectors will be captured with the Jefferson Lab FADC module, which collects and processes data from 16 charged particle sensors with 10 or 12 bit resolution at 250 MHz sample rate. Up to sixteen FADC modules transfer energy information to a central energy summing module for each readout crate. The sums from the crates are combined to form a global energy sum that is used to trigger data readout for all modules. The Energy Sum module and FADC modules have been designed using the VITA-41 VME64 switched serial (VXS) standard. The VITA- 41 standard defines payload and switch slot module functions, and offers an elegant engineered solution for Multi-Gigabit serial transmission on a standard VITA-41 backplane. The Jefferson Lab Energy Sum module receives data serially at a rate of up to 6 Giga-bits per second from the FADC modules. Both FADC and Energy Sum modules have been designed and assembled and this paper describes the integrated tests using both high speed modules in unison

43 PARTICLE ACCELERATORS↗

The impact of pulsed RFI on the coded BER performance of the nonlinear satellite communication channel

Communication links from low orbiting spacecraft to a central ground station, via satellite repeater, may be susceptible to significant performance degradation if high-level, pulsed radio frequency interference (RFI) must be contended with. The present paper examines the coded bit error rate (BER) performance of a communication system in which BPSK modulation is employed, pulsed CW or pulsed noise RFI is present, and the transponder contains a nonlinearity characterized by arbitrary AM/AM and AM/PM characteristics. A major result of this paper is an analytic method for determining soft decision statistics of the receiver demodulator output, in which pulsed RFI effects are accounted for. It is demonstrated that this result can be analytically applied to the approximate determination of the BER at the output of a Viterbi decoder, when convolutional coding is employed.

Weinberg, A.↗

A Framework for Simulation of Aircraft Flyover Noise Through a Non-Standard Atmosphere

This paper describes a new framework for the simulation of aircraft flyover noise through a non-standard atmosphere. Central to the framework is a ray-tracing algorithm which defines multiple curved propagation paths, if the atmosphere allows, between the moving source and listener. Because each path has a different emission angle, synthesis of the sound at the source must be performed independently for each path. The time delay, spreading loss and absorption (ground and atmosphere) are integrated along each path, and applied to each synthesized aircraft noise source to simulate a flyover. A final step assigns each resulting signal to its corresponding receiver angle for the simulation of a flyover in a virtual reality environment. Spectrograms of the results from a straight path and a curved path modeling assumption are shown. When the aircraft is at close range, the straight path results are valid. Differences appear especially when the source is relatively far away at shallow elevation angles. These differences, however, are not significant in common sound metrics. While the framework used in this work performs off-line processing, it is conducive to real-time implementation.

Arntzen, Michael↗

Integration of Functional MRI and White Matter Tractography in Stereotactic Radiosurgery Clinical Practice

Purpose: To study the efficacy of the integration of functional magnetic resonance imaging (fMRI) and diffusion tensor imaging tractography data into stereotactic radiosurgery clinical practice. Methods and Materials: fMRI and tractography data sets were acquired and fused with corresponding anatomical MR and computed tomography images of patients with arteriovenous malformation (AVM), astrocytoma, brain metastasis, or hemangioma and referred for stereotactic radiosurgery. The acquired data sets were imported into a CyberKnife stereotactic radiosurgery system and used to delineate the target, organs at risk, and nearby functional structures and fiber tracts. Treatment plans with and without the incorporation of the functional structures and the fiber tracts into the optimization process were developed and compared. Results: The nearby functional structures and fiber tracts could receive doses of >50% of the maximum dose if they were excluded from the planning process. In the AVM case, the doses received by the Broadmann-17 structure and the optic tract were reduced to 700 cGy from 1,400 cGy and to 1,200 cGy from 2,000 cGy, respectively, upon inclusion into the optimization process. In the metastasis case, the motor cortex received 850 cGy instead of 1,400 cGy; and in the hemangioma case, the pyramidal tracts received 780 cGy instead of 990 cGy. In the astrocytoma case, the dose to the motor cortex bordering the lesion was reduced to 1,900 cGy from 2,100 cGy, and therefore, the biologically equivalent dose in three fractions was delivered instead. Conclusions: Functional structures and fiber tracts could receive high doses if they were not considered during treatment planning. With the aid of fMRI and tractography images, they can be delineated and spared.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Transbrachial Access for Radiologic Manipulation of Problematic Central Venous Catheters in a Pediatric Population

A transfemoral venous approach is the current standard for accessing malpositioned and fractured central venous catheters (CVCs). The purpose of this study was (1) to describe a transbrachial approach for correction and (2) to assess the success and failure of this method in a pediatric population. A 12-year retrospective review of all patients referred for correction of malpositioned, retained, and fractured CVCs was conducted. Based on the performing interventionalist's preference, transbrachial or transfemoral venous sheaths where placed under ultrasonographic guidance. Diagnostic angiographic catheters and snares were used to manipulate the catheters. Patients who underwent the transfemoral approach received postprocedural monitoring for 4 hours, whereas patients who underwent the transbrachial approach were allowed unrestricted activity immediately after hemostasis was obtained. Technical success of malpositioned lines was defined (1) by final position in the superior vena cava or at the cavoatrial junction on postprocedural imaging or (2) by successful removal of retained catheter fragments, if present. Transbrachial approach was used for access in 11 patients. Problematic lines included malpositioned (n = 10) and retained (n = 1) lines. The ipsilateral arm was used for transbrachial entry in 7 patients. Initial use of angiographic catheters was attempted in 7 cases, of which 4 were successful. All 3 unsuccessful cases had tips positioned in the contralateral brachiocephalic vein, and these were successfully repositioned using snares. A combination of snares and angiographic catheters was used in 2 cases. Snares were used for all other cases. Technical success by way of the transbrachial approach was observed in all cases. Periprocedural follow-up demonstrated no immediate complications. We conclude that the transbrachial approach is a suitable alternative to the transfemoral approach for catheter tip position correction. Tip malposition in the contralateral brachiocephalic vein suggests higher rate of conversion to use of snare devices.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The MJO-ENSO Relationship: A Re-assessment

Noting the similarities among the spatial patterns of outgoing longwave radiation among MJO and ENSO, Lau and Chan speculated a possible relationship between the two phenomena. This speculation received a substantial boost in credibility after the 1997-98 El Nino, when MJO activities were found to be substantially enhanced prior to the onset of the warm phase, and clear signals of oceanic Kelvin waves forced by MJO induced anomalous surface wind were detected as possible triggers of ENSO. Yet statistical and modeling studies have so far yielded either nil or at best, very weak relationship between MJO activities and SST. Recently Kessler suggested using an MJO index which includes convective variability in the equatorial central Pacific lead to a more robust MJO-ENSO relationship. Clearly, while MJO might have been instrumental in triggering some El Nino, there are other events that can occur without any MJO trigger.

Lau, William K. M.↗

Current and future ozone risks to global terrestrial biodiversity and ecosystem processes

Abstract Risks associated with exposure of individual plant species to ozone (O 3 ) are well documented, but implications for terrestrial biodiversity and ecosystem processes have received insufficient attention. This is an important gap because feedbacks to the atmosphere may change as future O 3 levels increase or decrease, depending on air quality and climate policies. Global simulation of O 3 using the Community Earth System Model ( CESM ) revealed that in 2000, about 40% of the Global 200 terrestrial ecoregions ( ER ) were exposed to O 3 above thresholds for ecological risks, with highest exposures in North America and Southern Europe, where there is field evidence of adverse effects of O 3 , and in central Asia. Experimental studies show that O 3 can adversely affect the growth and flowering of plants and alter species composition and richness, although some communities can be resilient. Additional effects include changes in water flux regulation, pollination efficiency, and plant pathogen development. Recent research is unraveling a range of effects belowground, including changes in soil invertebrates, plant litter quantity and quality, decomposition, and nutrient cycling and carbon pools. Changes are likely slow and may take decades to become detectable. CESM simulations for 2050 show that O 3 exposure under emission scenario RCP 8.5 increases in all major biomes and that policies represented in scenario RCP 4.5 do not lead to a general reduction in O 3 risks; rather, 50% of ER s still show an increase in exposure. Although a conceptual model is lacking to extrapolate documented effects to ER s with limited or no local information, and there is uncertainty about interactions with nitrogen input and climate change, the analysis suggests that in many ER s, O 3 risks will persist for biodiversity at different trophic levels, and for a range of ecosystem processes and feedbacks, which deserves more attention when assessing ecological implications of future atmospheric pollution and climate change.

Fuhrer, Jürg↗

Standard and Nonstandard Craniospinal Radiotherapy Using Helical TomoTherapy

Purpose: To show the advantages of planning and delivering craniospinal radiotherapy with helical TomoTherapy (TomoTherapy Inc., Madison, WI) by presenting 4 cases treated at our institution. Methods and Materials: We first present a standard case of craniospinal irradiation in a patient with recurrent myxopapillary ependymoma (MPE) and follow this with 2 cases requiring differential dosing to multiple target volumes. One of these, a patient with recurrent medulloblastoma, required a lower dose to be delivered to the posterior fossa because the patient had been previously irradiated to the full dose, and the other required concurrent boosts to leptomeningeal metastases as part of his treatment for newly diagnosed MPE. The final case presented is a patient with pronounced scoliosis who required spinal irradiation for recurrent MPE. Results: The four cases presented were planned and treated successfully with Helical Tomotherapy. Conclusions: Helical TomoTherapy delivers continuous arc-based intensity-modulated radiotherapy that gives high conformality and excellent dose homogeneity for the target volumes. Increased healthy tissue sparing is achieved at higher doses albeit at the expense of larger volumes of tissue receiving lower doses. Helical TomoTherapy allows for differential dosing of multiple targets, resulting in very elegant dose distributions. Daily megavoltage computed tomography imaging allows for precision of patient positioning, permitting a reduction in planning margins and increased healthy tissue sparing in comparison with standard techniques.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Mapping Patterns of Local Recurrence After Pancreaticoduodenectomy for Pancreatic Adenocarcinoma: A New Approach to Adjuvant Radiation Field Design

Purpose: To generate a map of local recurrences after pancreaticoduodenectomy (PD) for patients with resectable pancreatic ductal adenocarcinoma (PDA) and to model an adjuvant radiation therapy planning treatment volume (PTV) that encompasses a majority of local recurrences. Methods and Materials: Consecutive patients with resectable PDA undergoing PD and 1 or more computed tomography (CT) scans more than 60 days after PD at our institution were reviewed. Patients were divided into 3 groups: no adjuvant treatment (NA), chemotherapy alone (CTA), or chemoradiation (CRT). Cross-sectional scans were centrally reviewed, and local recurrences were plotted to scale with respect to the celiac axis (CA), superior mesenteric artery (SMA), and renal veins on 1 CT scan of a template post-PD patient. An adjuvant clinical treatment volume comprising 90% of local failures based on standard expansions of the CA and SMA was created and simulated on 3 post-PD CT scans to assess the feasibility of this planning approach. Results: Of the 202 patients in the study, 40 (20%), 34 (17%), and 128 (63%) received NA, CTA, and CRT adjuvant therapy, respectively. The rate of margin-positive resections was greater in CRT patients than in CTA patients (28% vs 9%, P=.023). Local recurrence occurred in 90 of the 202 patients overall (45%) and in 19 (48%), 22 (65%), and 49 (38%) in the NA, CTA, and CRT groups, respectively. Ninety percent of recurrences were within a 3.0-cm right-lateral, 2.0-cm left-lateral, 1.5-cm anterior, 1.0-cm posterior, 1.0-cm superior, and 2.0-cm inferior expansion of the combined CA and SMA contours. Three simulated radiation treatment plans using these expansions with adjustments to avoid nearby structures were created to demonstrate the use of this treatment volume. Conclusions: Modified PTVs targeting high-risk areas may improve local control while minimizing toxicities, allowing dose escalation with intensity-modulated or stereotactic body radiation therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Structural Aspects of Neutron Survival Probabilities

The neutron survival probability (and related quantities including probabilities of extinction and initiation) is a central element of the broader stochastic theory of neutron populations and finds application in fields including reactor start-up, analysis of reactor power bursts and criticality accidents, and safeguards. In a full neutron transport formulation, the equation governing the single-neutron survival probability is a backward or adjoint-like integro-partial differential equation with the added complexity of being highly nonlinear. Analogous formulations of this equation exist in the context of many approximate theories of neutron transport, with the point kinetics formulation having received significant theoretical attention since the 1940s. This work continues this tradition by providing a novel analysis of the single-neutron survival probability equation using the tools of boundary layer theory. The analysis reveals that the “fully dynamic” solution of the single-neutron survival probability equation—and some key probability distributions derived from it—may be cast as a singular perturbation around the underlying quasi-static single-neutron probability of initiation. In this perturbation solution, the expansion parameter is the ratio of the neutron generation time to a macroscopic time scale characterizing the overall system evolution; this interpretation illuminates some of the fundamental structural aspects of neutron survival phenomena.

97 MATHEMATICS AND COMPUTING↗

Immunotoxicological and neurotoxicological profile of health effects following subacute exposure to geogenic dust from sand dunes at the Nellis Dunes Recreation Area, Las Vegas, NV

Exposure to geogenic particulate matter (PM) comprised of mineral particles has been linked to human health effects. However, very little data exist on health effects associated with geogenic dust exposure in natural settings. Therefore, we characterized particulate matter size, metal chemistry, and health effects of dust collected from the Nellis Dunes Recreation Area (NDRA), a popular off-road vehicle area located near Las Vegas, NV. Adult female B6C3F1 mice were exposed to several concentrations of mineral dust collected from active and vegetated sand dunes in NDRA. Dust samples (median diameter: 4.4 μm) were suspended in phosphate-buffered saline and delivered at concentrations ranging from 0.01 to 100 mg dust/kg body weight by oropharyngeal aspiration. ICP-MS analyses of total dissolution of the dust resulted in aluminum (55,090 μg/g), vanadium (70 μg/g), chromium (33 μg/g), manganese (511 μg/g), iron (21,600 μg/g), cobalt (9.4 μg/g), copper (69 μg/g), zinc (79 μg/g), arsenic (62 μg/g), strontium (620 μg/g), cesium (13 μg/g), lead 25 μg/g) and uranium (4.7 μg/g). Arsenic was present only as As(V). Mice received four exposures, once/week over 28-days to mimic a month of weekend exposures. Descriptive and functional assays to assess immunotoxicity and neurotoxicity were performed 24 h after the final exposure. The primary observation was that 0.1 to 100 mg/kg of this sand dune derived dust dose-responsively reduced antigen-specific IgM antibody responses, suggesting that dust from this area of NDRA may present a potential health risk. - Graphical abstract: During periods of heavy wind erosion, dense dust clouds of locally emitted geogenic dust enrobe the central Nellis Dune Recreation Area dunes. - Highlights: • Toxicological effects were characterized specific to geogenic dust exposure from a recreational sand dune site in Nevada. • The geogenic dust is a mixture of many metals and crystalline silica. • Exposure to geogenic dust dose-responsively decreased IgM antibody responses in a mouse model.

60 APPLIED LIFE SCIENCES↗

Development and Deployment of a Compact Eye-Safe Scanning Differential absorption Lidar (DIAL) for Spatial Mapping of Carbon Dioxide for Monitoring/Verification/Accounting at Geologic Sequestration Sites

A scanning differential absorption lidar (DIAL) instrument for monitoring carbon dioxide has been developed. The laser transmitter uses two tunable discrete mode laser diodes (DMLD) operating in the continuous wave (cw) mode with one locked to the online absorption wavelength and the other operating at the offline wavelength. Two in-line fiber optic switches are used to switch between online and offline operation. After the fiber optic switch, an acousto- optic modulator (AOM) is used to generate a pulse train used to injection seed an erbium doped fiber amplifier (EDFA) to produce eye-safe laser pulses with maximum pulse energies of 66 {micro}J, a pulse repetition frequency of 15 kHz, and an operating wavelength of 1.571 {micro}m. The DIAL receiver uses a 28 cm diameter Schmidt-Cassegrain telescope to collect that backscattered light, which is then monitored using a photo-multiplier tube (PMT) module operating in the photon counting mode. The DIAL instrument has been operated from a laboratory environment on the campus of Montana State University, at the Zero Emission Research Technology (ZERT) field site located in the agricultural research area on the western end of the Montana State University campus, and at the Big Sky Carbon Sequestration Partnership site located in north-central Montana. DIAL data has been collected and profiles have been validated using a co-located Licor LI-820 Gas Analyzer point sensor.

47 OTHER INSTRUMENTATION↗

Hybrid indirect-drive/direct-drive target for inertial confinement fusion

A hybrid indirect-drive/direct drive for inertial confinement fusion utilizing laser beams from a first direction and laser beams from a second direction including a central fusion fuel component; a first portion of a shell surrounding said central fusion fuel component, said first portion of a shell having a first thickness; a second portion of a shell surrounding said fusion fuel component, said second portion of a shell having a second thickness that is greater than said thickness of said first portion of a shell; and a hohlraum containing at least a portion of said fusion fuel component and at least a portion of said first portion of a shell; wherein said hohlraum is in a position relative to said first laser beam and to receive said first laser beam and produce X-rays that are directed to said first portion of a shell and said fusion fuel component; and wherein said fusion fuel component and said second portion of a shell are in a position relative to said second laser beam such that said second portion of a shell and said fusion fuel component receive said second laser beam.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Hybrid indirect-drive/direct-drive target for inertial confinement fusion

A hybrid indirect-drive/direct drive for inertial confinement fusion utilizing laser beams from a first direction and laser beams from a second direction including a central fusion fuel component; a first portion of a shell surrounding said central fusion fuel component, said first portion of a shell having a first thickness; a second portion of a shell surrounding said fusion fuel component, said second portion of a shell having a second thickness that is greater than said thickness of said first portion of a shell; and a hohlraum containing at least a portion of said fusion fuel component and at least a portion of said first portion of a shell; wherein said hohlraum is in a position relative to said first laser beam and to receive said first laser beam and produce X-rays that are directed to said first portion of a shell and said fusion fuel component; and wherein said fusion fuel component and said second portion of a shell are in a position relative to said second laser beam such that said second portion of a shell and said fusion fuel component receive said second laser beam.

Perkins, Lindsay John↗

Clinical Experience With Radiation Therapy in the Management of Neurofibromatosis-Associated Central Nervous System Tumors

Purpose: Patients with neurofibromatosis (NF) develop tumors of the central nervous system (CNS). Radiation therapy (RT) is used to treat these lesions. To better define the efficacy of RT in these patients, we reviewed our 20-year experience. Methods and Materials: Eighteen patients with NF with CNS tumors were treated from 1986 to 2007. Median follow-up was 48 months. Progression was defined as growth or recurrence of an irradiated tumor on serial imaging. Progression-free survival (PFS) was measured from the date of RT completion to the date of last follow-up imaging study. Actuarial rates of overall survival (OS) and PFS were calculated according to the Kaplan-Meier method. Results: Eighty-two tumors in 18 patients were irradiated, with an average of five tumors/patient. Median age at treatment was 25 years (range, 4.3-64 years). Tumor types included acoustic neuroma (16%), ependymoma (6%), low-grade glioma (11%), meningioma (60%), and schwanomma/neurofibroma (7%). The most common indication for treatment was growth on serial imaging. Most patients (67%) received stereotactic radiosurgery (median dose, 1,200 cGy; range, 1,000-2,400 cGy). The OS rate at 5 years was 94%. Five-year PFS rates were 75% (acoustic neuroma), 100% (ependymoma), 75% (low-grade glioma), 86% (meningioma), and 100% (schwanomma/neurofibroma). Thirteen acoustic neuromas had a local control rate of 94% with a 50% hearing preservation rate. Conclusions: RT provided local control, OS, and PFS rates similar to or better than published data for tumors in non-NF patients. Radiation therapy should be considered in NF patients with imaging progression of CNS tumors.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Electronic transport properties of one dimensional lithium nanowire using density functional theory

Single nanowire electrode devices are a unique platform for studying as energy storage devices. Lithium nanowire is of much importance in lithium ion batteries and therefore has received a great deal of attention in past few years. In this paper we investigated structural and electronic transport properties of Li nanowire using density functional theory (DFT) with SIESTA code. Electronic transport properties of Li nanowire are investigated theoretically. The calculations are performed in two steps: first an optimized geometry for Li nanowire is obtained using DFT calculations, and then the transport relations are obtained using NEGF approach. SIESTA and TranSIESTA simulation codes are used in the calculations correspondingly. The electrodes are chosen to be the same as the central region where transport is studied, eliminating current quantization effects due to contacts and focusing the electronic transport study to the intrinsic structure of the material. By varying chemical potential in the electrode regions, an I-V curve is traced which is in agreement with the predicted behavior. Agreement of bulk properties of Li with experimental values make the study of electronic and transport properties in lithium nanowires interesting because they are promising candidates as bridging pieces in nanoelectronics. Transmission coefficient and V-I characteristic of Li nano wire indicates that Li nanowire can be used as an electrode device.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗