Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “beam diagnostics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 793 records · Page 44

Imaging Station Multi-Foil Target

The Axis II Downstream Transport (DST) of the Dual Axis Radiographic Hydrodynamic Testing (DARHT) Facility is the final subassembly of the particle accelerator whose primary objective is to focus the 4-pulse beam as it enters the Target Region. Before the beam reaches the Target Region, it passes through two imaging stations located in the DST. At Imaging Station E (ISE) and Imaging Station C (ISC), diagnostics are conducted and experimenters study beam physics using specialized targets. Different targets are used depending on the objective of the study. The desire to conduct specific experiments has driven a need for a multi-foil target. This new design has been engineered to allow for new capabilities, and diagnostics to be studied at ISC. To accommodate new parameters, three different configurations have been conceived. Although each of the three designs differ from each other, their function and purpose remain consistent. Each target is engineered to secure a variable amount of target foils at variable spacing while Imaging Station experiments are conducted. Beam diagnostics and data from the targets are analyzed through various sized viewports on the imaging stations. The objective of this technical note is to document the purpose and functionality of the targets. Design considerations, assembly instructions, and maintenance recommendations are also discussed. Additionally, each target and its respective advantages and disadvantages are covered in detail.

43 PARTICLE ACCELERATORS↗

A non-invasive beam profile monitor for charged particle beams

Non-interceptive beam profile monitors are highly desirable in almost all particle accelerators. Such techniques are especially valuable in applications where real time monitoring of the beam properties is required while beam preservation and minimal influence on the vacuum are of the greatest importance. This applies to many kinds of accelerators such as high energy machines where the normal diagnostics cannot withstand the beam's power, medical machines where treatment time is valuable and cannot be allocated to diagnostics and also low energy, low intensity accelerators where the beam's properties are difficult to measure. This paper presents the design of a gas-jet based beam profile monitor which was developed and commissioned at the Cockcroft Institute and can operate in a very large background pressure range from 10{sup −7} down to below 10{sup −11} millibars. The functioning principle of the monitor is described and the first experimental results obtained using a 5 keV electron beam are discussed.

43 PARTICLE ACCELERATORS↗

Characterization of Defocused Electron Beams and Welds in Stainless Steel and Refractory Metals using the Enhanced Modified Faraday Cup Diagnostic

As the first part of a project to compare new generation, continuous wave, laser welding technology to traditional electron beam welding technology, electron beam welds were made on commercially pure vanadium refractory metal and 21-6-9 austenitic stainless steel. The electron beam welds were made while employing EB diagnostics to fully characterize the beams so that direct comparisons could be made between electron beam and laser beams and the welds that each process produces.

36 MATERIALS SCIENCE↗

Investigation of mechanism of anode plasma formation in ion diode with dielectric anode

The results of investigation of the anode plasma formation in a diode with a passive anode in magnetic insulation mode are presented. The experiments have been conducted using the BIPPAB-450 ion accelerator (350–400 kV, 6–8 kA, 80 ns) with a focusing conical diode with B{sub r} external magnetic field (a barrel diode). For analysis of plasma formation at the anode and the distribution of the ions beam energy density, infrared imaging diagnostics (spatial resolution of 1–2 mm) is used. For analysis of the ion beam composition, time-of-flight diagnostics (temporal resolution of 1 ns) were used. Our studies have shown that when the magnetic induction in the A-C gap is much larger than the critical value, the ion beam energy density is close to the one-dimensional Child-Langmuir limit on the entire working surface of the diode. Formation of anode plasma takes place only by the flashover of the dielectric anode surface. In this mode, the ion beam consists primarily of singly ionized carbon ions, and the delay of the start of formation of the anode plasma is 10–15 ns. By reducing the magnetic induction in the A-C gap to a value close to the critical one, the ion beam energy density is 3–6 times higher than that calculated by the one-dimensional Child-Langmuir limit, but the energy density of the ion beam is non-uniform in cross-section. In this mode, the anode plasma formation occurs due to ionization of the anode material with accelerated electrons. In this mode, also, the delay in the start of the formation of the anode plasma is much smaller and the degree of ionization of carbon ions is higher. In all modes occurred effective suppression of the electronic component of the total current, and the diode impedance was 20–30 times higher than the values calculated for the mode without magnetic insulation of the electrons. The divergence of the ion beam was 4.5°–6°.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Adaptive Machine Learning for Robust Diagnostics and Control of Time-Varying Particle Accelerator Components and Beams

Machine learning (ML) is growing in popularity for various particle accelerator applications including anomaly detection such as faulty beam position monitor or RF fault identification, for non-invasive diagnostics, and for creating surrogate models. ML methods such as neural networks (NN) are useful because they can learn input-output relationships in large complex systems based on large data sets. Once they are trained, methods such as NNs give instant predictions of complex phenomenon, which makes their use as surrogate models especially appealing for speeding up large parameter space searches which otherwise require computationally expensive simulations. However, quickly time varying systems are challenging for ML-based approaches because the actual system dynamics quickly drifts away from the description provided by any fixed data set, degrading the predictive power of any ML method, and limits their applicability for real time feedback control of quickly time-varying accelerator components and beams. In contrast to ML methods, adaptive model-independent feedback algorithms are by design robust to un-modeled changes and disturbances in dynamic systems, but are usually local in nature and susceptible to local extrema. In this work, we propose that the combination of adaptive feedback and machine learning, adaptive machine learning (AML), is a way to combine the global feature learning power of ML methods such as deep neural networks with the robustness of model-independent control. We present an overview of several ML and adaptive control methods, their strengths and limitations, and an overview of AML approaches.

97 MATHEMATICS AND COMPUTING↗

Active Beam Spectroscopy

Charge eXchange Recombination Spectroscopy (CXRS) plays a pivotal role in the diagnostics of hot fusion plasmas and is implemented currently in most of the operating devices. In the present report the main features of CXRS are summarized and supporting software packages encompassing 'Spectral Analysis Code CXSFIT', 'Charge Exchange Analysis Package CHEAP', and finally 'Forward Prediction of Spectral Features' are described.Beam Emission Spectroscopy (BES) is proposed as indispensable cross-calibration tool for absolute local impurity density measurements and also for the continuous monitoring of the neutral beam power deposition profile. Finally, a full exploitation of the 'Motional Stark Effect' pattern is proposed to deduce local pitch angles, total magnetic fields and possibly radial electric fields.For the proposed active beam spectroscopy diagnostic on ITER comprehensive performance studies have been carried out. Estimates of expected spectral signal-to-noise ratios are based on atomic modelling of neutral beam stopping and emissivities for CXRS, BES and background continuum radiation as well as extrapolations from present CXRS diagnostic systems on JET, Tore Supra, TEXTOR and ASDEX-UG.Supplementary to thermal features a further promising application of CXRS has been proposed recently for ITER, that is a study of slowing-down alpha particles in the energy range up to 2 MeV making use of the 100 keV/amu DNB (Diagnostic Neutral Beam) and the 500 keV/amu HNB (Heating Neutral Beam). Synthetic Fast Ion Slowing-Down spectra are evaluated in terms of source rates and slowing-down parameters.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Wide-field turbulence imaging with beam emission spectroscopy

Imaging of the size, shape, time-averaged, and time-resolved dynamics of long-wavelength density turbulence structures is accomplished with an expanded, high-sensitivity, wide-field beam emission spectroscopy (BES) diagnostic on DIII-D. A 64-channel BES system is configured with an 8x8 grid of discrete channels that image an approximately 7x9 cm region at the outboard midplane. The grid covers multiple correlation lengths and each channel shape matches the measured radial-poloidal correlation length asymmetry of turbulent eddies. The wide field 8x8 imaging capability allows for sampling of essentially the full two-dimensional spatial correlation function for typical plasma conditions. The sampled area can be radially scanned over 0.4<r/a<1, including the core (n-tilde/n<1%), pedestal, and scrape-off-layer. The resulting time-resolved visualizations of turbulence and flows provide critical data on turbulence dynamics.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

MAST YAG Thomson scattering upgrade alignment system

The recent upgrade to the MAST YAG Thomson scattering while enhancing the diagnostic capabilities increased the complexity of the system. There are eight YAG lasers now operational, doubling the number from the previous setup. This means alignment between each laser individually and reference points is essential to guarantee data quality and diagnostic reliability. To address this issue an alignment system was recently installed. It mimics the beams alignment in MAST by sampling 1% of the laser beam that is sent into a telescope which demagnifies by a factor of 8. The demagnified beam is viewed with a CCD camera. By scanning the camera the profile and position of the beams in the scattering zone and in a range of several meters inside MAST can be determined. Therefore alignment is checked along the beam path without having to sample it inside the vessel. The experimental apparatus and test procedures are described.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Analysis of CT Numbers and Relative Proton Stopping Powers for Real Tissue Samples

The accuracy of computer planning of clinical proton dose distribution is partly determined by the precision of the conversion of CT Hounsfield Units to relative proton stopping powers. The calibration curves from three different sources were compared. We have found about 5% differences between proton stopping power values in the range from -700 HU to 0 HU. Calibration data for several soft tissues and phantom materials were also experimentally measured. The data for the tissues are in a good agreement with the calibration curves however data for phantom materials have significant deviations.

07 ISOTOPE AND RADIATION SOURCES↗

Advanced Control Methods for Particle Accelerators (ACM4PA) 2019

Los Alamos is currently developing novel particle accelerator controls and diagnostics algorithms to enable higher quality beams with lower beam losses than is currently possible. The purpose of this workshop was to consider tuning and optimization challenges of a wide range of particle accelerators including linear proton accelerators such as the Los Alamos Neutron Science Center (LANSCE), rings such as the Advanced Photon Source (APS) synchrotron, free electron lasers (FEL) such as the Linac Coherent Light Source (LCLS) and LCLS-II, the European X-ray Free Electron Laser (EuXFEL), the Swiss FEL, and the planned MaRIE FEL, and plasma wake- eld accelerators such as FACET, FACET-II, and AWAKE at CERN. One major challenge is an the ability to quickly create very high quality, extremely intense, custom current and energy pro le beams while working with limited real time non-invasive diagnostics and utilizing time-varying uncertain initial beam distributions and accelerator components. Currently, a few individual accelerator labs have been developing and applying their own diagnostics tools and custom control and ML algorithms for au- tomated machine tuning and optimization. The goal of this workshop was to bring together a group of accelerator physicists and accelerator related control and ML experts in order to de ne which controls and diagnostics would be most useful for existing and future accelerators and to create a plan for developing a new family of algorithms that can be shared and maintained by the community.

43 PARTICLE ACCELERATORS↗

A multiple gap plasma cathode electron gun and its electron beam analysis in self and trigger breakdown modes

In the present paper, a pseudospark discharge based multiple gap plasma cathode electron gun is reported which has been operated separately in self and trigger breakdown modes using two different gases, namely, argon and hydrogen. The beam current and beam energy have been analyzed using a concentric ring diagnostic arrangement. Two distinct electron beams are clearly seen with hollow cathode and conductive phases. The hollow cathode phase has been observed for ∼50 ns where the obtained electron beam is having low beam current density and high energy. While in conductive phase it is high current density and low energy electron beam. It is inferred that in the hollow cathode phase the beam energy is more for the self breakdown case whereas the current density is more for the trigger breakdown case. The tailor made operation of the hollow cathode phase electron beam can play an important role in microwave generation. Up to 30% variation in the electron beam energy has been achieved keeping the same gas and by varying the breakdown mode operations. Also, up to 32% variation in the beam current density has been achieved for the trigger breakdown mode at optimized trigger position by varying the gas type.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Recent Experiments At Ndcx-II: Irradiation Of Materials Using Short, Intense Ion Beams

We present an overview of the performance of the Neutralized Drift Compression Experiment-II (NDCX-II) accelerator at Berkeley Lab, and summarize recent studies of material properties created with nanosecond and millimeter-scale ion beam pulses. The scientific topics being explored include the dynamics of ion induced damage in materials, materials synthesis far from equilibrium, warm dense matter and intense beam-plasma physics. We summarize the improved accelerator performance, diagnostics and results of beam-induced irradiation of thin samples of, e.g., tin and silicon. Bunches with over 3x10^10 ions, 1- mm radius, and 2-30 ns FWHM duration have been created. To achieve these short pulse durations and mm-scale focal spot radii, the 1.2 MeV He+ ion beam is neutralized in a drift compression section which removes the space charge defocusing effect during final compression and focusing. Quantitative comparison of detailed particle-in-cell simulations with the experiment play an important role in optimizing accelerator performance; these keep pace with the accelerator repetition rate of ~1/minute.

Seidl, PA↗

Suppression of spurious mode oscillation in mega-watt 77-GHz gyrotron as a high quality probe beam source for the collective Thomson scattering in LHD

Collective Thomson scattering (CTS) diagnostic requires a strong probing beam to diagnose a bulk and fast ion distribution function in fusion plasmas. A mega-watt gyrotron for electron cyclotron resonance heating is used as a probing beam in the large helical device. Spurious mode oscillations are often observed during the turning on/off phase of the modulation. The frequency spectra of the 77-GHz gyrotron output power have been measured, and then one of the spurious modes, which interferes with the CTS receiver system, is identified as the TE{sub 17,6} mode at the frequency of 74.7 GHz. The mode competition calculation indicates that the increase of the magnetic field strength at the gyrotron resonator can avoid such a spurious mode and excite only the main TE{sub 18,6} mode. The spurious radiation at the 74.7 GHz is experimentally demonstrated to be suppressed in the stronger magnetic field than that optimized for the high-power operation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Differential rotation of plasma in the GOL-3 multiple-mirror trap during injection of a relativistic electron beam

Results of spectral and magnetic diagnostics of plasma differential rotation in the GOL-3 multiplemirror trap are presented. It is shown that the maximum frequency of plasma rotation about the longitudinal axis reaches 0.5 MHz during the injection of a relativistic electron beam into the plasma. The data of two diagnostics agree if there is a region with a higher rotation frequency near the boundary of the electron beam. Plasma differential rotation can be an additional factor stabilizing interchange modes in the GOL-3 facility.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Beam Characterization and Coherent Optical Transition Radiation Studies at the Advanced Photon Source Linac

The Advanced Photon Source facility includes a 450-MeV S-band linac with the option for injection from a photocathode (PC) rf gun. A diode-pumped, twice-frequency doubled Nd:glass regen laser (263 nm) is used with the Cu PC to generate the ele ctron beams. Characterization of these beams and studies of the microbunching instability following beam compression in the four-dipole magnetic chicane are described. A suite of diagnostics is employed including a three-screen emittance section, a FIR co herent transition radiation autocorrelator, electron spectrometers, and an optical diagnostics end station. An energy chirp impressed on the beam is used to compress the 1-2 ps, rms bunch as it passes through the chicane. With compression, bunch lengths o f 170-200 fs, rms at 450 pC are measured, and coherent optical transition radiation (COTR) due to the microbunching instability is observed. Mitigation techniques of the COTR in the beam profile diagnostics are demonstrated both spectrally and temporally. At 100 pC without compression normalized transverse emittances of 1.8 and 2.7 microns are observed in the x and y planes, in reasonable agreement with initial ASTRA simulations.

43 PARTICLE ACCELERATORS↗