Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “accelerator diagnostics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 793 records · Page 44

Source size measurement options for low-emittance light sources

Radiation-based techniques for measuring electron source sizes are widely used as emittance diagnostics at existing synchrotron sources. Three of these techniques, namely, pinhole imaging, double-slit interferometry, and a K-edge filter-based beam position and size monitor system (ps-BPM), are evaluated for measuring source sizes at low-emittance storage rings. Each technique is reviewed with a detailed system description, design optimization, and practical considerations targeted for small source sizes. Pinhole imaging has the simplest setup and gives the beam profile in both transverse dimensions but with limited resolution. Double-slit interferometry has the highest resolution but with a limited detectable size range. The ps-BPM system shows reasonable resolution for monitoring small source sizes and divergence and can give real-time information of the source position and angle. New facilities may consider an integrated system that combines some or all of these techniques.

43 PARTICLE ACCELERATORS↗

Strong ultrafast nonlinear optical response from megaelectronvolt electrons in semiconductors

Understanding radiation–matter interactions on ultrafast timescales is essential for radiation detection technologies, particularly those requiring precise timing, such as plasma monitoring, synchrotron diagnostics and medical imaging. However, the detection of highly ionizing radiation is challenging due to the stochastic nature of the interactions, resulting in dispersed energy deposition. Here we show a nonlinear optical response in semiconductors induced by 150-fs, 4.2-MeV electrons that generate highly localized charge carriers. The induced sub-10-ps optical modulation reached up to 24.5%, accompanied by a blueshift in the absorption edge consistent with band filling and carrier densities of 10 18 cm −3 . These carrier densities are 100-fold higher than expected from the deposited energy, indicating the extreme spatial localization of carriers at inelastic collisions along the ionization trajectories, thereby leading to the observed modulation. The strong nonlinearity of the MeV-electron-induced optical response enables the precise spatiotemporal detection of ionizing radiation at room temperature using common semiconductors and laser systems.

Jeong, D. [Stanford Univ., CA (United States)] (OR↗

Development Of Non-Invasive Beam Diagnostics By Quantum Optics-Based Detection

We report our effort and latest progress developing diagnostics using quantum optics-based detection method for determining the spatial properties and current of electron beams. As electrons pass through a dilute vapor of rubidium atoms, their magnetic field perturb the atomic spin’s quantum state and causes polarization rotation of a laser resonant with an optical transition of the atoms. By measuring the polarization rotation angle across the laser beam, we recreate a 2D projection of the magnetic field and use it to determine the e-beam position, size and total current. We tested this method for an e-beam with currents ranging from 30 to 110 µA. Our study shows this approach is insensitive to electron kinetic energy, and is initially verified experimentally between 10 to 20 keV. A different approach was also performed with highly excited rubidium atoms in Rydberg states through a coherent two photon process. We use this detection scheme to measure the electric field generated by a

Zhang, S. [Thomas Jefferson National Accelerator F↗

Summary of the CeC Experiment in RHIC Run 21

The coherent electron cooling (CeC) experiment at RHIC is crucial for determining the feasibility of this technique for cooling the hadron beam in the electron-ion collider (EIC) and reaching the luminosity of 10 34 cm -1 s -1 . During RHIC Run 21, various progresses have been made including successfully commissioning the time resolved diagnostic beam line (TRDBL), achieving the key performance parameters (KPP) of the system and the development of novel methods for accurate alignment of the electron beam with the ion beam. While the longitudinal cooling of the ion beam with cooling time of 100 hours was observed during Run 21, it was related to the traditional electron cooling since the cooling rate was not as sensitive to the energy of the electron beam as what one would expect from the CeC. In Run 21, we were not able to observe the longitudinal cooling of the ion beam caused by CeC and the main challenges are identified as the insufficient stability of the electrons' energy. The sources of the energy jitter have been identified and we are making improvements to the stability of the CeC system for Run 22.

43 PARTICLE ACCELERATORS↗

Single shot cathode transverse momentum imaging in high brightness photoinjectors

In state of the art photoinjector electron sources, thermal emittance from photoemission dominates the final injector emittance. Therefore, low thermal emittance cathode developments and diagnostics are very important. Conventional thermal emittance measurements for the high gradient gun are time-consuming and thus thermal emittance is not measured as frequently as quantum efficiency during the lifetime of photocathodes, although both are important properties for the photoinjector optimizations. In this paper, a single shot measurement of photoemission transverse momentum, i.e., thermal emittance per rms laser spot size, is proposed for photocathode rf guns. By tuning the gun solenoid focusing, the electrons’ transverse momenta at the cathode are imaged to a downstream screen, which enables a single shot measurement of both the rms value and the detailed spectra of the photoelectrons’ transverse momenta. Both simulations and proof of principle experiments are reported.

43 PARTICLE ACCELERATORS↗

Progress on the Plasmoid Thruster Experiment (PTX)

A plasmoid is a compact plasma structure with an integral magnetic field, that may be categorized according to the relative strength of the poloidal and toroidal magnetic field (B(sub p) and B(sub t), respectively). An object with B(sub p)/B(sub t), much much more than 1 is called a Field Reverse Configuration (FRC); if B(sub p) approximately equal to B(sub t), it is called a Spheromak. The thruster operates by repetitively producing plasmoids that are accelerated and ejected at high velocity. As this process is inductive, there are no electrodes. Also, the magnetic structure of the plasmoid should suppress thermal and mass losses to the wall, and improve detachment of the plasma exhaust from the thruster. This concept should be capable of producing an Isp in the range of 5,000 - 10,000 s with thrust densities of order 10(exp 5) N per square meters. The current experiment is designed to produce jet powers in the range of 5-10 kW, although the concept should be scalable into the MW range. In PTX, the plasmoid is formed inside of a single turn conical theta-pinch coil (17.58 cone angle). The coil is driven by a 640 nF, 35 kV capacitor bank, which rings at a frequency of 500 kHz. Previous experiments on PTX were conducted with a static-fill of propellant gas (6% H2 in He), and demonstrated reliable ionization over a pressure range of 40 - 200 mTorr. We are now adding a fast gas-puff valve to load the propellant, and a ringing pre-ionization circuit (f = 5 Mhz) to better control the plasmoid formation. An alternate coil (8.58 cone angle) will also be used, so as to investigate the effect of coil shape on performance. In addition, a variety of propellants will be used, including hydrogen, nitrogen, and argon. The plasmoid mass and velocity will be measured with a variety of diagnostics, including external B-dot probes and flux loops, a high-speed framing camera, and a HeNe laser interferometer. Internal B-dot probes and a quadruple Langmuir probe will provide additional measurements of the plasmoid shape and structure, as well as density, and will be described in a companion paper. The experimental results will be compared to calculations made using a 0-D coil-gun model and also a 2-D time dependent MHD code.

Martin, Adam↗

Ion emission from warm dense matter produced by irradiation with a soft x-ray free-electron laser

Here we report on an experiment performed at the FLASH2 free-electron laser (FEL) aimed at producing warm dense matter via soft x-ray isochoric heating. In the experiment, we focus on study of the ions emitted during the soft x-ray ablation process using time-of-flight electron multipliers and a shifted Maxwell–Boltzmann velocity distribution model. We find that most emitted ions are thermal, but that some impurities chemisorbed on the target surface, such as protons, are accelerated by the electrostatic field created in the plasma by escaped electrons. The morphology of the complex crater structure indicates the presence of several ion groups with varying temperatures. We find that the ion sound velocity is controlled by the ion temperature and show how the ion yield depends on the FEL radiation attenuation length in different materials.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

High precision magnetic field measurement and mapping of the LEReC 180 degree bending magnet using very low field NMR with hall combined probe (140 - 350 gauss)

The Relativistic Heavy Ion Collider (RHIC) at BNL are using the Low Energy RHIC Electron Cooling (LEReC) to conduct experiments that search for the quantum chromodynamic (QCD) critical point. The first ever electron cooling based on the RF acceleration of electron beams was experimentally demonstrated on April 5, 2019 at LEReC at BNL. The first critical step in obtaining successful 3D non-magnetized cooling of the Au ion bunches in the RHIC cooling section was matching the electron beam energy with a relative error less than 5*10 -4 to the ion beam energy. Part of the LEReC beamline is a dipole magnet that bends the electron beam 180 degree. One of the most outstanding measurement challenges is that the dipole field is so low (≈200 G). Most of the existing NMR probes can only measure fields >400 G. Lower signal-to-noise ratio at low fields is requires the use of larger sample volumes. Working with CAYLAR, a NMR probe has been redesigned and optimized for these low field measurements with high resolution. We report the methods, challenges, and results for extensive magnetic field mappings of the 180 dipole magnet. A combination of NMR and Hall sensors has been successfully implemented to measure uniform field regimes inside the magnet center area and non-uniform field regimes at the magnet ends. Detailed measurement and mapping have been performed at five radii and five heights along the beam trajectory. Meanwhile a finite element magnetic modeling simulation of the magnet using Opera software has been performed. The calculated and measured data are compared, and the calculated data is good reference for measured data over long length mapping from magnet edge to center. The measured magnetic measurement data is directly useful for beam instrumentation, diagnostics and operation.

Magnetic Field Measurement↗

Design and Analysis of a Halo-Measurement Diagnostics

A large dynamical-range diagnostics (LDRD) design at Jefferson Lab will be used at the FAST-IOTA injector to measure the transverse distribution of halo associated with a high-charge electron beam. One important aspect of this work is to explore the halo distribution when the beam has significant angular momentum (i.e. is magnetized). The beam distribution is measured by recording radiation produced as the beam impinges a YAG:Ce screen. The optical radiation is split with a fraction directed to a charged-couple device (CCD) camera. The other part of the radiation is reflected by a digital micromirror device (DMD) that masks the core of the beam distribution. Combining the images recorded by the two cameras provides a measurement of the transverse distribution with over a large dynamical range. The design and analysis of the optical system will be discussed including optical simulation using SRW and the result of a mockup experiment to test the performances of the system will be presented.

43 PARTICLE ACCELERATORS↗

Quadruple Langmuir probe characterization of different fuel gases in a plasma deflagration accelerator

Astrophysical flows may be studied by reproducing similar conditions using a coaxial plasma accelerator operating in the deflagration regime (or plasma deflagration accelerator). This allows for the recreation and investigation of dynamics present in complex highly coupled plasma systems at the laboratory scale. Here we report on measurements of the plasma density, temperature, plasma potential and velocity found using a quadruple Langmuir probe (QLP) on such a deflagration accelerator in the form of the Stanford Coaxial High ENerGy (CHENG) device operating with multiple gases – specifically argon, nitrogen and hydrogen. Experiments show a general decrease in bulk plasma velocity with gas atomic mass from upwards of 120 km s –1 with hydrogen to less than 30 km s –1 with argon. There was an accompanying increase in peak plasma density with increasing atomic mass from ~3 × 10 20 m –3 with hydrogen to ~1.5 × 10 21 m –3 with argon. It was found that the momentum flux and internal energy density also generally increase with atomic mass while the particle flux is constant between shots. Further investigation is needed to understand these correlations and the underlying physics. Lastly, comparisons with scaling laws show that while the CHENG device may be operated in such a way as to simulate the effects of bulk solar wind movement, it may not properly capture the thermal effects.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Real-time plasma monitoring framework for advanced plasma control and ML-research in DIII-D

Real-time and adaptive plasma control is crucial for robust tokamak operation, requiring sensitivity and tolerance measurements of the plasma state. This paper presents the implementation of an integrated real-time plasma monitoring framework on the DIII-D tokamak to support advanced control approaches, including machine-learning (ML) methods. The system is built on the SHIELD framework, a high-performance modular architecture that provides a unified pipeline for integrating diverse diagnostics. The framework leverages high-bandwidth digitizers, fast numerical processing, and deterministic, low-latency interconnects to stream high-fidelity data from diagnostics such as electron cyclotron emission (ECE), beam emission spectroscopy (BES), CO interferometers, and a visible tangential divertor camera (TangTV). The system’s validity is demonstrated through direct comparisons of real-time and offline data. Furthermore, we present two key applications of the developed plasma monitoring system with ML-based plasma control strategies, including real-time divertor detachment and active Alfvén Eigenmode control. As a result, this work presents a robust and scalable approach for integrating high-frequency, multidimensional diagnostics into advanced control algorithms for future fusion devices.

AI/ML↗

Inverse model based error detection in beamline optics

Optics tuning in transfer lines and LINACs can be challenging due to the fact that multiple combinations of machine settings can lead to the same diagnostic output. Moreover, the lack of a periodic solution can limit the ability to infer optics in the same way as rings from BPM signals. Model based approaches are often used to assist with the optics tuning in combination with optimization or parameter estimation. Here we have developed a novel approach using machine learning inverse models trained on a known configuration to detect variations in quadrupole settings without explicitly including them in the model. This paper shows a comparison of neural network models and linear models on both a simulation based study and experimental studies conducted at the AGS to RHIC transfer line at Brookhaven National Lab.

43 PARTICLE ACCELERATORS↗

Presound: UAV Diagnostic System Enabled by Vibration-Based Machine Learning

A low-weight, inexpensive small unmanned aerial system (sUAS) that takes off, performs a mission, lands, and safely stows and recharges itself has myriad future applications ranging from agricultural imaging to last-mile package delivery. Likewise, Urban Air Mobility (UAM) systems will enable people to take air taxis from point to point in cities, rapidly moving commuters long distances without concern for road traffic and congestion. Fully electric aviation systems will be cleaner and quieter than ground transport. Cities could eliminate cars and buses, and convert roads to higher capacity bike and pedestrian throughways. Yet, for sUAS as well as UAM, system reliability and assurance is a limiting factor to deploying affordable autonomous flight systems. For this bright future of aviation to be realized, aircraft must be able to autonomously and accurately self-diagnose health issues both before takeoff and during flight. The GreenSight PreSound system is designed to identify defects on aircraft through intelligent analysis of vibration. It accomplishes this by measuring structural vibrations induced by the vehicle’s own propellers, and analyzing that data using a machine learning model that determines whether a defect is present. The PreSound system is designed to require no human oversight, and to operate across a wide array of vehicles through re-training of the model for each target aircraft. PreSound has been developed and seen limited early success using data collected from the GreenSight Dreamer sUAS, a 5lb quadrotor vehicle designed for aerial imaging applications. The final detection model, trained on data with props spinning at 50% throttle, achieves excellent performance with over 99% average accuracy in detecting blade damage using a single FFT vector input. It demonstrates the ability to generalize to new types of blade damage, correctly classifying a different type of blade damage with 98% accuracy. Full test pulses were classified with 100% accuracy, and in live testing, all sets of data during blade movement were classified accurately with over 95% confidence. When trained on in-flight data, the same model achieves an average accuracy of 85% in distinguishing between undamaged and blade-damaged states in flight. The authors believe that these accuracies show significant potential of this approach to expand unmanned flight safety, with significant potential benefits in accelerating Advanced Aerial Mobility (AAM) and UAM aviation applications.

UAS↗

Global Issues of Radiopharmaceutical Access and Availability: a Nuclear Medicine Global Initiative Project

The Nuclear Medicine Global Initiative (NMGI) was formed in 2012 by 13 international organizations to promote human health by advancing the field of nuclear medicine and molecular imaging by supporting the practice and application of nuclear medicine. The first project focused on standardization of administered activities in pediatric nuclear medicine and resulted in two manuscripts. For its second project the NMGI chose to explore issues impacting on access and availability of radiopharmaceuticals around the world. Methods: Information was obtained by survey responses from 35 countries on available radioisotopes, radiopharmaceuticals and kits for diagnostic and therapeutic use. Issues impacting on access and availability of radiopharmaceuticals in individual countries were also identified. Results: Detailed information on radiopharmaceuticals utilized in each country, and sources of supply, was evaluated. Responses highlighted problems in access particularly due to the reliance on a sole provider, regulatory issues and reimbursement, as well as issues of facilities and workforce particularly in low- and middle-income countries. Conclusion: Finally, strategies to address access and availability of radiopharmaceuticals are outlined, to enable timely and equitable patient access to nuclear medicine procedures worldwide. In the face of disruptions to global supply chains by the COVID-19 outbreak, renewed focus on ensuring reliable supply of radiopharmaceuticals is a major priority for nuclear medicine practice globally.

43 PARTICLE ACCELERATORS↗

Four-dimensional emittance measurement at the Spallation Neutron Source

A coasting hadron beam with an elliptical transverse profile, uniform charge density, and small transverse four-dimensional (4D) emittance could improve accelerator performance in several contexts. A phase space painting method to generate such a distribution is being tested in the Spallation Neutron Source (SNS) accumulator ring. A critical component of these efforts is to measure the 4D emittance of the beam during accumulation. The 4D emittance can be reconstructed from measured beam profiles in two ways: in the multi-optics method, the optics between a reconstruction and measurement location are varied; in the fixed-optics method, multiple measurement locations are used without modifying the optics. The fixed-optics method is faster but can lead to large uncertainty in the reconstructed 4D emittance. In this paper, we implement a variant of the multi-optics method using the four available wire-scanners near the SNS target. We also modify the wire-scanner region to reduce the uncertainty of the fixed-optics method. We then demonstrate the usefulness of the fixed-optics method by reconstructing the 4D emittance evolution during accumulation in the SNS ring.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

One-to-one mapping between the electromagnetic modes of cylindrical and coaxial half-wave cavities

Design of radio frequency (RF) couplers and diagnostics require a good understanding of the electromagnetic mode patterns of RF cavities. This study investigates the adiabatic transformation of transverse magnetic (TM) modes in a cylindrical cavity into transverse electromagnetic (TEM) modes of a coaxial cavity by gradually introducing an inner conductor. Using CST Studio Suite, we simulate the eigenmode evolution as the geometry transforms from a pure cylindrical to a coaxial configuration. We track the behavior of TM010 through TM014 modes to observe the continuous evolution into the corresponding TEM0 through TEM4 modes of the coaxial cavity. The process is governed by the evolution of the electric field orientation as the geometry shifts, enabling the axial TM fields to reorient into the radial electric field configuration of TEM modes. Field patterns, eigen-frequencies, and mode indentities are analyzed throughtout the transition. The results provide simulation-based evidence that TM to TEM conversion occurs without generation of newer eigenmodes, offering a valuable insight into the design of transition regions in superconducting RF (SRF) systems and provides a foundation for experimental validation.

Accelerator Physics↗

Proton imaging of high-energy-density laboratory plasmas

Proton imaging has become a key diagnostic for measuring electromagnetic fields in high-energy-density (HED) laboratory plasmas. Compared to other techniques for diagnosing fields, proton imaging is a measurement that can simultaneously offer high spatial and temporal resolution and the ability to distinguish between electric and magnetic fields without the protons perturbing the plasma of interest. Consequently, proton imaging has been used in a wide range of HED experiments, from inertial-confinement fusion to laboratory astrophysics. An overview is provided on the state of the art of proton imaging, including a discussion of experimental considerations like proton sources and detectors, the theory of proton-imaging analysis, and a survey of experimental results demonstrating the breadth of applications. As a result, topics at the frontiers of proton-imaging development are also described, along with an outlook on the future of the field.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗