Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “accelerator applications”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 793 records · Page 44

Bridging the Gap Between Modern UX Design and Particle Accelerator Control Room Interfaces

Accelerator control systems often represent relatively complex and safety-sensitive human-machine interfaces within process control industries. These systems are technically robust and reflect the cumulative integration of solutions built and adapted across decades. One of the regular, unfortunate casualties of provisional accelerator control system updates is their human-system interfaces (HSIs) which often lag behind modern usability and design standards. An additional challenge is that although there is a multitude of established human factors (HF), and user experience (UX) principles for everyday digital applications, there are very few (if any) established principles for complex and safety-critical applications for an accelerator. This paper argues for the importance of established HF and UX principles (herein referred to as human-centered design principles) into the development of accelerator HSIs, emphasizing the need for clarity, consistency, responsiveness, and cognitive accessibility. Drawing from HF/UX best practices and human-centered design, this paper discusses how these approaches can enhance operator performance, reduce human error, and improve accelerator personnel collaboration. Case studies from Accelerator Control Operations Research Network (ACORN) at Fermilab are explored to demonstrate how interfaces built with human-centered design principles can scale with system complexity while remaining intuitive and efficient for diverse user roles including operators, machine experts, and engineers. By bridging the gap between traditional control system design and modern human-centered design methods, this paper provides a roadmap for evolving accelerator HSIs into more usable, maintainable, and effective tools.

Hill, Rachael [Idaho Natl. Lab.]↗

Forecast model applications of retrieved three dimensional liquid water fields

Forecasts are made for tropical storm Emily using heating rates derived from the SSM/I physical retrievals described in chapters 2 and 3. Average values of the latent heating rates from the convective and stratiform cloud simulations, used in the physical retrieval, are obtained for individual 1.1 km thick vertical layers. Then, the layer-mean latent heating rates are regressed against the slant path-integrated liquid and ice precipitation water contents to determine the best fit two parameter regression coefficients for each layer. The regression formulae and retrieved precipitation water contents are utilized to infer the vertical distribution of heating rates for forecast model applications. In the forecast model, diabatic temperature contributions are calculated and used in a diabatic initialization, or in a diabatic initialization combined with a diabatic forcing procedure. Our forecasts show that the time needed to spin-up precipitation processes in tropical storm Emily is greatly accelerated through the application of the data.

Raymond, William H.↗

Facility for Advanced Accelerator Experimental Tests at SLAC (FACET) Conceptual Design Report

This Conceptual Design Report (CDR) describes the design of FACET. It will be updated to stay current with the developing design of the facility. This CDR begins as the baseline conceptual design and will evolve into an 'as-built' manual for the completed facility. The Executive Summary, Chapter 1, gives an introduction to the FACET project and describes the salient features of its design. Chapter 2 gives an overview of FACET. It describes the general parameters of the machine and the basic approaches to implementation. The FACET project does not include the implementation of specific scientific experiments either for plasma wake-field acceleration for other applications. Nonetheless, enough work has been done to define potential experiments to assure that the facility can meet the requirements of the experimental community. Chapter 3, Scientific Case, describes the planned plasma wakefield and other experiments. Chapter 4, Technical Description of FACET, describes the parameters and design of all technical systems of FACET. FACET uses the first two thirds of the existing SLAC linac to accelerate the beam to about 20GeV, and compress it with the aid of two chicanes, located in Sector 10 and Sector 20. The Sector 20 area will include a focusing system, the generic experimental area and the beam dump. Chapter 5, Management of Scientific Program, describes the management of the scientific program at FACET. Chapter 6, Environment, Safety and Health and Quality Assurance, describes the existing programs at SLAC and their application to the FACET project. It includes a preliminary analysis of safety hazards and the planned mitigation. Chapter 7, Work Breakdown Structure, describes the structure used for developing the cost estimates, which will also be used to manage the project. The chapter defines the scope of work of each element down to level 3.

43 PARTICLE ACCELERATORS↗

Proposed New Accelerator Design for Homeland Security X-Ray Applications

In the security and inspection market, there is a push towards highly mobile, reduced-dose active interrogation scanning and imaging systems to allow operation in urban environments. To achieve these goals, the accelerator system design needs to be smaller than existing systems. A smaller radiation exclusion zone may be accomplished through better beam collimation and an integrated, x-ray-source/detector-array assembly to allow feedback and control of an intensity-modulated x-ray source. A shaped low-Z target in the x-ray source can be used to generate a more forward peaked x-ray beam. Electron-beam steering can then be applied to direct the forward-peaked x rays toward areas in the cargo with high attenuation. This paper presents an exploratory study to identify components and upgrades that would be required to meet the desired specifications, as well as the best technical approach to design and build a prototype.

43 PARTICLE ACCELERATORS↗

Monitoring applications once they are in the user community

Once an application is released into the user community, obtaining prompt and high quality information on application usage, applicability and reliability can be a challenge. Most Linux and Solaris applications used at RHIC and associated accelerators have been instrumented so that application and crash information is gathered, stored and forwarded to the appropriate developer for immediate analysis. To support this process, databases were created to track developer and application information. In order to keep these databases relevant, a web based application release procedure was created to collect information and automatically update the database. Additional capabilities have been developed that utilize and expand on the various components of this system to promote communication between developers and users, and to monitor applications. An application feedback feature allows users to instantly communicate with application developers. An application history system records application usage and reliability.

43 PARTICLE ACCELERATORS↗

MO-FG-303-04: A Smartphone Application for Automated Mechanical Quality Assurance of Medical Accelerators

Purpose: The mechanical quality assurance (QA) of medical accelerators consists of a time consuming series of procedures. Since most of the procedures are done manually – e.g., checking gantry rotation angle with the naked eye using a level attached to the gantry –, it is considered to be a process with high potential for human errors. To remove the possibilities of human errors and reduce the procedure duration, we developed a smartphone application for automated mechanical QA. Methods: The preparation for the automated process was done by attaching a smartphone to the gantry facing upward. For the assessments of gantry and collimator angle indications, motion sensors (gyroscope, accelerator, and magnetic field sensor) embedded in the smartphone were used. For the assessments of jaw position indicator, cross-hair centering, and optical distance indicator (ODI), an optical-image processing module using a picture taken by the high-resolution camera embedded in the smartphone was implemented. The application was developed with the Android software development kit (SDK) and OpenCV library. Results: The system accuracies in terms of angle detection error and length detection error were < 0.1° and < 1 mm, respectively. The mean absolute error for gantry and collimator rotation angles were 0.03° and 0.041°, respectively. The mean absolute error for the measured light field size was 0.067 cm. Conclusion: The automated system we developed can be used for the mechanical QA of medical accelerators with proven accuracy. For more convenient use of this application, the wireless communication module is under development. This system has a strong potential for the automation of the other QA procedures such as light/radiation field coincidence and couch translation/rotations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Alcoa ram fastener: A reusable blind rivet

Results of tensile, shear, fatigue and accelerated weathering tests are presented for the ram fastener, a reusable, single unit blind rivet. The effects of variations in hole size, grip length and sheet thickness on strength properties of the fastener were determined. The test results show these fasteners to have strength characteristics suitable for light structural applications. Exposure to accelerated weathering did not impair their performance.

Dewalt, W. J.↗

Current capabilities and future needs for semiconductor ion implantation (invited)

For many years the largest commercial application for particle accelerators has been semiconductor ion implantation. These tools differ from other accelerators in many respects. In particular they are automated to a very high degree and, in addition to technical performance requirements their success depends on other key metrics including productivity, availability and cost of ownership. These tools also operate with a large variety of species, four orders of magnitude of energy range and five orders of magnitude of dose range. The ion source is a key component of implanters with its own performance metrics that include beam current, lifetime, and materials cost. In this paper, we describe the primary applications for ion implantation and some of the beam line architectures that are used. We describe the ion source that has evolved for this application. Some key future challenges for implanter ion source development are also discussed.

36 MATERIALS SCIENCE↗

Deployment and validation of predictive 6-dimensional beam diagnostics through generative reconstruction with standard accelerator elements

Understanding the 6-dimensional phase space distribution of particle beams is essential for optimizing accelerator performance. Conventional diagnostics such as use of transverse deflecting cavities offer detailed characterization but require dedicated hardware and space. Generative phase space reconstruction (GPSR) methods have shown promise in beam diagnostics, yet prior implementations still rely on such components. Here we present the first experimental implementation and validation of the GPSR methodology, realized by the use of standard accelerator elements including accelerating cavities and dipole magnets, to achieve complete 6-dimensional phase space reconstruction. Through simulations and experiments at the Pohang Accelerator Laboratory X-ray Free Electron Laser facility, we successfully reconstruct complex, nonlinear beam structures. Furthermore, we validate the methodology by predicting independent downstream measurements excluded from training, revealing the reconstruction closely resembling ground truth. This advancement establishes a pathway for predictive diagnostics across beamline segments while reducing hardware requirements and expanding applicability to various accelerator facilities.

Kim, Seongyeol [Pohang Univ. of Science and Techno↗

ELECTRON ACCELERATION IN PULSAR-WIND TERMINATION SHOCKS: AN APPLICATION TO THE CRAB NEBULA GAMMA-RAY FLARES

The γ -ray flares from the Crab Nebula observed by AGILE and Fermi -LAT reaching GeV energies and lasting several days challenge the standard models for particle acceleration in pulsar-wind nebulae because the radiating electrons have energies exceeding the classical radiation-reaction limit for synchrotron. Previous modeling has suggested that the synchrotron limit can be exceeded if the electrons experience electrostatic acceleration, but the resulting spectra do not agree very well with the data. As a result, there are still some important unanswered questions about the detailed particle acceleration and emission processes occurring during the flares. We revisit the problem using a new analytical approach based on an electron transport equation that includes terms describing electrostatic acceleration, stochastic wave-particle acceleration, shock acceleration, synchrotron losses, and particle escape. An exact solution is obtained for the electron distribution, which is used to compute the associated γ -ray synchrotron spectrum. We find that in our model the γ -ray flares are mainly powered by electrostatic acceleration, but the contributions from stochastic and shock acceleration play an important role in producing the observed spectral shapes. Our model can reproduce the spectra of all the Fermi -LAT and AGILE flares from the Crab Nebula, using magnetic field strengths in agreement with the multi-wavelength observational constraints. We also compute the spectrum and duration of the synchrotron afterglow created by the accelerated electrons, after they escape into the region on the downstream side of the pulsar-wind termination shock. The afterglow is expected to fade over a maximum period of about three weeks after the γ -ray flare.

79 ASTRONOMY AND ASTROPHYSICS↗

Three dimensional intensity modulated brachytherapy (IMBT): Dosimetry algorithm and inverse treatment planning

Purpose: The feasibility of intensity modulated brachytherapy (IMBT) to improve dose conformity for irregularly shaped targets has been previously investigated by researchers by means of using partially shielded sources. However, partial shielding does not fully explore the potential of IMBT. The goal of this study is to introduce the concept of three dimensional (3D) intensity modulated brachytherapy and solve two fundamental issues regarding the application of 3D IMBT treatment planning: The dose calculation algorithm and the inverse treatment planning method. Methods: A 3D IMBT treatment planning system prototype was developed using the MATLAB platform. This system consists of three major components: (1) A comprehensive IMBT source calibration method with dosimetric inputs from Monte Carlo (EGSnrc) simulations; (2) a ''modified TG-43'' (mTG-43) dose calculation formalism for IMBT dosimetry; and (3) a physical constraint based inverse IMBT treatment planning platform utilizing a simulated annealing optimization algorithm. The model S700 Axxent electronic brachytherapy source developed by Xoft, Inc. (Fremont, CA), was simulated in this application. Ten intracavitary accelerated partial breast irradiation (APBI) cases were studied. For each case, an ''isotropic plan'' with only optimized source dwell time and a fully optimized IMBT plan were generated and compared to the original plan in various dosimetric aspects, such as the plan quality, planning, and delivery time. The issue of the mechanical complexity of the IMBT applicator is not addressed in this study. Results: IMBT approaches showed superior plan quality compared to the original plans and the isotropic plans to different extents in all studied cases. An extremely difficult case with a small breast and a small distance to the ribs and skin, the IMBT plan minimized the high dose volume V{sub 200} by 16.1% and 4.8%, respectively, compared to the original and the isotropic plans. The conformity index for the target was increased by 0.13 and 0.04, respectively. The maximum dose to the skin was reduced by 56 and 28 cGy, respectively, per fraction. Also, the maximum dose to the ribs was reduced by 104 and 96 cGy, respectively, per fraction. The mean dose to the ipsilateral and contralateral breasts and lungs were also slightly reduced by the IMBT plan. The limitations of IMBT are the longer planning and delivery time. The IMBT plan took around 2 h to optimize, while the isotropic plan optimization could reach the global minimum within 5 min. The delivery time for the IMBT plan is typically four to six times longer than the corresponding isotropic plan. Conclusions: In this study, a dosimetry method for IMBT sources was proposed and an inverse treatment planning system prototype for IMBT was developed. The improvement of plan quality by 3D IMBT was demonstrated using ten APBI case studies. Faster computers and higher output of the source can further reduce plan optimization and delivery time, respectively.

60 APPLIED LIFE SCIENCES↗

Acceleration of energetic particles at solar wind shocks

A review of the acceleration of energetic ions at interplanetary shocks is presented with an emphasis on the theory of diffusive shock acceleration and interplanetary traveling shocks. The basic theory is discussed briefly, including wave excitation. Ten predictions of the theory as outlined by Kennel et al. (1985) are presented and found to compare favorably with the observations of the 11, 12 November 1978 event. Some problems are presented which should be addressed by future theoretical/experimental work. A simple illustrative application of diffusive acceleration theory is made to the acceleration of ions at shocks in the distant heliosphere and compared qualitatively with the intensity profiles observed by Pioneer 10. Finally, Some brief thoughts on shock acceleration at high solar latitudes are presented.

Lee, M. A.↗

High-energy protons from submicron-sized targets

Improving of intensity contrast ratio of intense short laser pulses is making it possible to use submicron-sized targets, both spherical and plane, in the interest of proton acceleration for different applications. The way of improving of the ion beam quality is utilization of targets with two ion species - heavy ions (majority) and light ions, e.g. protons, (minority). Two different approaches, analytical theory and particle-in-cell simulations (PIC) are presented for studying the characteristics of laser-triggered ions due to the Coulomb-like mechanism of particle acceleration from submicron-sized targets. The comparative analysis of explosions of heterogeneous (layered) and homogeneously mixed targets for production of best quality ion bunches has been performed. We also found the regime of anisotropic proton acceleration from spherical targets with light and heavy ions relevant to the experiments with submicron-diameter droplets from water spray target irradiated by an ultrashort intense laser pulse.

43 PARTICLE ACCELERATORS↗

Multi-objective optimization with an integrated electromagnetics and beam dynamics workflow

In particle accelerators, RF cavities are used to accelerate charged particle beams to designed high energy for physical applications. In a typical accelerator design, the optimization of RF cavities and the optimization of beam dynamics are carried out in separate studies. For a more general and unrestricted accelerator design, a coupled optimization of the RF cavities and the beam parameters is required. For this coupled optimization problem, we have developed an integrated electromagnetics and beam dynamics workflow management system. Within this system, the geometries for a set of cavity components are first adjusted; the field modes are then computed with an electromagnetics program, and imported into a beam dynamics program for beam dynamics simulation. This workflow is encapsulated into a parallel multi-objective optimizer to achieve the integrated accelerator design optimization. A multi fidelity strategy is developed to improve the speed of the optimizer. Furthermore, this integrated global optimization capability is illustrated using a photoinjector design example and yields an improved design.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A cryogenically cooled high voltage DC photoemission electron source

Linear electron accelerators and their applications such as ultrafast electron diffraction require compact high-brightness electron sources with high voltage and electric field at the photocathode to maximize the electron density and minimize space-charge induced emittance growth. Achieving high brightness from a compact source is a challenging task because it involves an often-conflicting interplay between various requirements imposed by photoemission, acceleration, and beam dynamics. Here we present a new design for a compact high voltage DC electron gun with a novel cryogenic photocathode system and report on its construction and commissioning process. This photoemission gun can operate at ~200 kV at both room temperature and cryogenic temperature with a corresponding electric field of 10 MV/m, necessary for achieving high quality electron beams without requiring the complexity of guns, e.g., based on RF superconductivity. Furthermore, it hosts a compact photocathode plug compatible with that used in several other laboratories opening the possibility of generating and characterizing electron beam from photocathodes developed at other institutions.

47 OTHER INSTRUMENTATION↗

Tunable Plasma Linearizer for Compensation of Nonlinear Energy Chirp

The removal of undesired nonlinear time-energy correlation (energy chirp) present in relativistic electron beams is crucial for many accelerator-based scientific applications, such as free-electron lasers, high-energy electron radiography, and MeV ultrafast electron microscopy. Here, we propose and demonstrate that a low-density plasma section can be used as a passive “linearizer” to significantly compensate for the nonlinear energy chirp imprinted on a beam by the curvature of the radio-frequency field in a conventional accelerator. Physically, the passage of the beam through the plasma excites a strong quasi-cosinoidal longitudinal decelerating wakefield that acts to mitigate the beam’s nonlinear energy chirp by superimposing a reverse chirp on the beam. Time-resolved phase-space measurements, combined with high-fidelity three-dimensional particle-in-cell simulations show that the longitudinal phase space of the beam core is almost completely linearized, leading to a fourfold reduction of the beam overall energy spread from 0.148% to 0.036% (FWHM).

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Proceedings of the 1998 International Computational Accelerator Physics Conference

The 1998 International Computational Accelerator Physics Conference, ICAP’98, was held September 14-18, 1998, at the Monterey Convention Center in Monterey, California. The meeting continued the tradition of four earlier Computational Accelerator Physics conferences, held in La Jolla, California (1988), Los Alamos, New Mexico (1990), Pleasanton, California (1993), and Williamsburg, Virginia (1996). ICAP’98 was organized by the Stanford Linear Accelerator Center (SLAC), Los Alamos National Laboratory (LANL), and the National Energy Research Scientific Computing Center (NERSC), and received support from the U.S. Department of Energy. The aim of this conference series is to discuss recent advances in Computational Accelerator Physics and their applications to solving important problems related to present and future accelerators. The ICAP’98 program included plenary sessions on modeling challenges in next-generation accelerators, state-of-the art methods in computational accelerator physics, and a view of what high-end computing would be like in the 21st century. There were also focused sessions on accelerator design and control, modeling high intensity beam phenomena, electromagnetic modeling, advanced algorithms, software environments and libraries, visualization and graphic interfaces, modeling advanced accelerator concepts, modeling the beam-beam interaction, computing wakefields, and combined particle/field simulations. In addition to these oral sessions there was a poster session and a vendor display. Prior to the start of the technical program, a half-day tutorial on High Performance Computing was hosted by NERSC. The ICAP series recognizes that computing and, in particular, advanced computing, is playing an increasingly important role in the successful design and development of major accelerator facilities, and in research and development leading to advances in accelerator technology. We expect that this new emphasis on high-end computing will continue in future ICAP conferences.

Ko, Kwok↗