Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “X RADIATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 793 records · Page 44

Improved Tensor Current Limit from 8 B 𝛽 Decay Including New Recoil-Order Calculations

A precision measurement of the 𝛽 + decay of 8 B was performed using the Beta-decay Paul Trap to determine the 𝛽−𝜈 angular correlation coefficient 𝑎 𝛽⁢𝜈 . The experimental results were combined with new ab initio symmetry-adapted no-core shell-model calculations to yield the second-most precise measurement from Gamow-Teller decays, 𝑎 𝛽⁢𝜈 = −0.3345 ± 0.001⁢9 stat ± 0.002⁢1 syst . This value agrees with the standard model value of −1/3 and improves uncertainties in 8 B by nearly a factor of 2. By combining results from 8 B and 8 Li , a tight limit on tensor current coupling to right-handed neutrinos was obtained. A recent global evaluation of all other precision 𝛽 decay studies suggested a nonzero value for right-handed neutrino coupling in contradiction with the standard model at just above 3⁢𝜎. Finally, the present results are of comparable sensitivity and do not support this finding.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Simulated X-Ray Radiographic Performance of a Bismuth-Loaded PVT Array

Recent material advancements in organic plastic scintillators enable marked increases in material detection efficiency, light yield, and pulse shape discrimination properties. These advances may resolve significant capability gaps for lowcost, portable, and durable dual-particle imaging (DPI) systems for nuclear safety, security, and safeguard purposes. One such material, a 21% bismuth-loaded polyvinyl toluene (BiPVT), is computationally evaluated as a small, pixelated radiographic array using Monte Carlo N-Particle (MCNP) and Zemax OpticStudio, and it is compared to identical evaluations of EJ-200 and EJ-256 arrays. MCNP software enables estimates of particle interaction and energy deposition, while OpticStudio computes optical light transport within each material. Here, computational estimates of spatial resolution and relative light collection at 370 kVp are found to agree with experimental results for both EJ-200 and EJ-256 arrays, thereby validating predictions of the same for the BiPVT array. As such, for equivalent exposures at 370 kVp, a BiPVT array may provide ~20× the light collection expected from EJ-200 and ~10× that expected from EJ-256. Similar comparisons of estimated light collection are also computed at 150 and 270 kVp, and these results suggest that BiPVT will provide significantly improved performance over EJ-200 and EJ-256 across all energies practical for portable X-ray radiography.

42 ENGINEERING↗

2020 Medical Device Sterilization Workshop: Continuing the Conversation, Summary Report

Technical advancements are making accelerator-based sources of radiation viable candidates for sterilization of medical devices. Electron beams and x-rays are becoming more cost-competitive and new facilities are being built to provide needed capacity and redundancy. As the industry becomes more receptive to these modalities, there is a need for information and data to enable prospective users to evaluate these options for their products. The workshops offered in 20191 and now in 2020 strive to foster conversation between device manufacturers, equipment and service providers on needs, capabilities, and knowledge.

43 PARTICLE ACCELERATORS↗

2024-03U-JWS01 - Initial Abstract

Abstract for recently approved CRADA joint work statement 2024-03U-JWS01 with University of Nevada Reno. Publication of abstract at time of approval satisfies requirements of DOE O 483.1B.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Using neutrons and x rays to measure plasma conditions in a solid sphere of deuterated polyethylene compressed to densities of 35 g/cc at temperatures of 2 keV and pressures of 40 Gbar

This paper describes an experiment that shock compresses the center of a solid deuterated polyethylene sphere, CD 2 , to densities of 35 g/cc and temperatures of 2 keV with corresponding pressure of 40 Gbar. The design employs a strong spherically converging shock launched through a solid ball of material using a Hohlraum radiation drive. As the shock coalesces at the center it produces a hot spot that we characterize by measuring the x-ray self-emission and 2.45 MeV neutrons emitted. Two-dimensional images and time-resolved measurements of the x rays emitted determine the size and time duration of the hot spot, leading to an estimated 2k eV electron temperature. The neutron time of flight spectrometer measures an average ion temperature of 1.06 ± 0.15 keV and neutron yield of 7.0 (±0.5) × 10 9 DD neutrons. Our new distribution function tool enables us to create a forward model of the experimental data based on 1D radiation-hydrodynamic simulations, leading to a better understanding of the plasma conditions that produce the measured neutrons and x rays. Furthermore, our simulations indicate that the x rays are produced in a short-lived hot-dense core over tens of picoseconds, whereas the neutron emission continues for about 200 ps, as the hot core starts to expand, thereby leading to a lower mean temperature of the plasma during neutron production. This finding is in agreement with the experimental data, and we therefore conclude that the forward-modeling is a useful tool for inferring the conditions of the hot spot in a laser-driven implosion during burn.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A case study of using x-ray Thomson scattering to diagnose the in-flight plasma conditions of DT cryogenic implosions

The design of inertial confinement fusion ignition targets requires radiation-hydrodynamics simulations with accurate models of the fundamental material properties (i.e., equation of state, opacity, and conductivity). Validation of these models is required via experimentation. A feasibility study of using spatially integrated, spectrally resolved, x-ray Thomson scattering measurements to diagnose the temperature, density, and ionization of the compressed DT shell of a cryogenic DT implosion at two-thirds convergence was conducted. Synthetic scattering spectra were generated using 1D implosion simulations from the LILAC code that were post processed with the x-ray scattering model, which is incorporated within SPECT3D. Analysis of two extreme adiabat capsule conditions showed that the plasma conditions for both compressed DT shells could be resolved.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Interferometric bunch length measurements of 3 MeV picocoulomb electron beams

We report picosecond bunch length measurements using an interferometric method for a 3 MeV electron beam having bunch charge ranging from 1 to 14 pC. The method senses the single-cycle sub-terahertz (THz) pulse emitted by each electron bunch as coherent transition radiation which, in turn, is analyzed using a Michelson-type interferometer, forming an interferogram that is then processed to yield the nominal electron bunch length. This sub-THz coherent radiation intensity was measured using a quasi-optical detector (QOD) operated at room temperature. This experiment was quite challenging since the divergence angle of the sub-THz pulse emitted by the low-energy electron bunch exceeds ±10°, and its pulse energy at the entrance to the detector was as low as 100 pJ. When compared to a conventional helium-cooled silicon composite bolometer designed for frequencies above 0.5 THz, the QOD provided much better signal-to-noise ratio in the ~80 GHz frequency range, which was critical for the successful measurement of the bunch length.

36 MATERIALS SCIENCE↗

Parameter estimation for X-ray scattering analysis with Hamiltonian Markov Chain Monte Carlo

Bayesian-inference-based approaches, in particular the random-walk Markov Chain Monte Carlo (MCMC) method, have received much attention recently for X-ray scattering analysis. Hamiltonian MCMC, a state-of-the-art development in the field of MCMC, has become popular in recent years. It utilizes Hamiltonian dynamics for indirect but much more efficient drawings of the model parameters. We described the principle of the Hamiltonian MCMC for inversion problems in X-ray scattering analysis by estimating high-dimensional models for several motivating scenarios in small-angle X-ray scattering, reflectivity, and X-ray fluorescence holography. Hamiltonian MCMC with appropriate preconditioning can deliver superior performance over the random-walk MCMC, and thus can be used as an efficient tool for the statistical analysis of the parameter distributions, as well as model predictions and confidence analysis.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

X-ray phase contrast and absorption imaging for the quantification of transient cavitation in high-speed nozzle flows

In this work, high-flux synchrotron radiation has been employed in a time-resolved manner to characterise the distinct topology features and dynamics of different cavitation regimes arising in a throttle orifice with an abrupt flow-entry contraction. Radiographs obtained though both X-ray phase- contrast and absorption imaging have been captured at 67,890 frames per second. The flow lied in the turbulent regime (Re=35,500), while moderate (CN=2.0) to well-established (CN=6.0) cavitation conditions were examined encompassing the cloud and vortical cavitation regimes with pertinent transient features, such as cloud-cavity shedding. X-ray Phase-Contrast Imaging (XPCI), exploiting the shift in the X-ray wave phase during interactions with matter, offers sharp-refractive index gradients in the interface region. Hence, it is suitable for capturing fine morphological fluctuations of transient cavitation structures. Nevertheless, the technique cannot provide information on the quantity of vapour within the orifice. Such data have been obtained utilising absorption imaging, where beam attenuation is not associated with scattering and refraction events, and hence can be explicitly correlated with the projected vapour thickness in line-of-sight measurements. A combination of the two methods is proposed, as it has been found is capable of quantifying the vapour content arising in the complex nozzle flow, while also faithfully illustrating the dynamics of the highly-transient cavitation features.

42 ENGINEERING↗

Instrumentation and experimental procedures for robust collection of X-ray diffraction data from protein crystals across physiological temperatures

Traditional X-ray diffraction data collected at cryo-temperatures have delivered invaluable insights into the three-dimensional structures of proteins, providing the backbone of structure–function studies. While cryo-cooling mitigates radiation damage, cryo-temperatures can alter protein conformational ensembles and solvent structure. Furthermore, conformational ensembles underlie protein function and energetics, and recent advances in room-temperature X-ray crystallography have delivered conformational heterogeneity information that can be directly related to biological function. Given this capability, the next challenge is to develop a robust and broadly applicable method to collect single-crystal X-ray diffraction data at and above room temperature. This challenge is addressed herein. The approach described provides complete diffraction data sets with total collection times as short as ~5 s from single protein crystals, dramatically increasing the quantity of data that can be collected within allocated synchrotron beam time. Its applicability was demonstrated by collecting 1.09–1.54 Å resolution data over a temperature range of 293–363 K for proteinase K, thaumatin and lysozyme crystals at BL14-1 at the Stanford Synchrotron Radiation Lightsource. Here, the analyses presented here indicate that the diffraction data are of high quality and do not suffer from excessive dehydration or radiation damage.

36 MATERIALS SCIENCE↗

Low-divergence femtosecond X-ray pulses from a passive plasma lens

Electron and X-ray beams originating from compact laser-wakefield accelerators have very small source sizes that are typically on the micrometre scale. Therefore, the beam divergences are relatively high, which makes it difficult to preserve their high quality during transport to applications. To improve on this, tremendous efforts have been invested in controlling the divergence of the electron beams, but no mechanism for generating collimated X-ray beams has yet been demonstrated experimentally. Here we propose and realize a scheme where electron bunches undergoing focusing in a dense, passive plasma lens can emit X-ray pulses with divergences approaching the incoherent limit. Furthermore, compared with conventional betatron emission, the divergence of this so-called plasma lens radiation is reduced by more than an order of magnitude in solid angle, while maintaining a similar number of emitted photons per electron. This X-ray source offers the possibility of producing brilliant and collimated few-femtosecond X-ray pulses for ultra-fast science, in particular for studies based on X-ray diffraction and absorption spectroscopy.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Optimization of echo-enabled harmonic generation toward coherent EUV and soft X-ray free-electron laser at NSLS-II

Prebunching via echo-enabled harmonic generation (EEHG) is an efficient way to reduce the radiator length and improve the longitudinal coherence as well as output stability in storage-ring-based free-electron lasers. We propose a conceptual design, which uses two straight sections to seed coherent extreme-ultraviolet (EUV) and soft X-ray emission with nearly MHz repetition rate. To take the large energy spread (10 –3 ) of a storage ring into account and utilize the existing bending magnets between the two straight sections as the first chicane, we implement a special modeling tool, named EEHG optimizer. This tool has been successfully applied to maximize the prebunching with a reasonably low energy modulation, thereby generating intense coherent X-ray pulses within a short undulator length (a few meters) limited by the available space of a storage ring. Numerical simulations confirm that the optimized EEHG parameters can be directly applied to generate a 10 MW scale peak power with fully coherent ultrafast EUV to soft X-ray pulses based on the NSLS-II parameters. This method can be easily extended to other types of diffraction-limited storage rings.

36 MATERIALS SCIENCE↗

Radiatively cooled magnetic reconnection experiments driven by pulsed power

We present evidence for strong radiative cooling in a pulsed-power-driven magnetic reconnection experiment. Two aluminum exploding wire arrays, driven by a 20 MA peak current, 300 ns rise time pulse from the Z machine (Sandia National Laboratories), generate strongly driven plasma flows (MA≈7) with anti-parallel magnetic fields, which form a reconnection layer (SL≈120) at the mid-plane. The net cooling rate far exceeds the Alfvénic transit rate (τcool−1/τA−1≫1), leading to strong cooling of the reconnection layer. We determine the advected magnetic field and flow velocity using inductive probes positioned in the inflow to the layer, and inflow ion density and temperature from analysis of visible emission spectroscopy. A sharp decrease in x-ray emission from the reconnection layer, measured using filtered diodes and time-gated x-ray imaging, provides evidence for strong cooling of the reconnection layer after its initial formation. X-ray images also show localized hotspots, regions of strong x-ray emission, with velocities comparable to the expected outflow velocity from the reconnection layer. These hotspots are consistent with plasmoids observed in 3D radiative resistive magnetohydrodynamic simulations of the experiment. X-ray spectroscopy further indicates that the hotspots have a temperature (170 eV) much higher than the bulk layer (≤75 eV) and inflow temperatures (about 2 eV) and that these hotspots generate the majority of the high-energy (>1 keV) emission.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Local aging effects in PuB 4 : Growing inhomogeneity and slow dynamics of local field fluctuations probed by 239 Pu NMR

Plutonium-based correlated electron materials host exotic physical phenomena ranging from unconventional heavy-fermion superconductivity to topological Kondo insulating states. Self-irradiation damage can influence many properties of such radioactive materials. Structural disorder effects due to α radiation have been frequently studied using techniques such as transport, thermodynamics, and x-ray diffraction. Here, in this study, we use 239 Pu nuclear magnetic resonance (NMR) to study the long-term influence of self-damage on the lattice and local electronic structures in a single crystal of the candidate topological insulator plutonium tetraboride (PuB 4 ). We first characterize the anisotropy of the 239 Pu resonance and confirm the local axial-site symmetry inferred from previous polycrystalline measurements. Aging effects are then evaluated over the time frame of six years. We find that, though the static 239 Pu NMR spectra show a slight modulation in their shape, their field-rotation pattern reveals no change in 239 Pu local site symmetry over time, suggesting that aging has a surprisingly small impact on the spatial distribution of the static hyperfine field. Further, ligand-site 11 B NMR finds little time-dependent change in the size of electric field gradient around 11 B sites. By contrast, aging has a prominent impact on the 239 Pu NMR relaxation processes and signal intensity. Specifically, aging-induced damage manifests itself as an increase in the spin-lattice relaxation time 𝑇 1 , an increased distribution of 𝑇 1 , and a signal intensity that decreases linearly by 20% per year. An effective spin-spin relaxation time 𝑇 2,eff in the aged sample shortens drastically towards lower temperature, suggesting growth of slow fluctuations of the hyperfine field that are linked to radiation-damage-induced inhomogeneity. Our NMR study sheds light on the interplay of radiation damage and local magnetic interactions in correlated insulators.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Quark and gluon helicity evolution at small x: revised and updated

We revisit the problem of small Bjorken-x evolution of the gluon and flavor-singlet quark helicity distributions in the shock wave (s-channel) formalism. Earlier works on the subject in the same framework resulted in an evolution equation for the gluon field-strength F 12 and quark “axial current” $\overline{\psi}\gamma$ + γ 5 ψ operators (sandwiched between the appropriate light-cone Wilson lines) in the double-logarithmic approximation (summing powers of α s ln 2 (1/x) with α s the strong coupling constant). In this work, we observe that an important mixing of the above operators with another gluon operator, ${}_D{}^{\leftarrow i} {}_D{}^{i}$, also sandwiched between the light-cone Wilson lines (with the repeated transverse index i = 1, 2 summed over), was missing in the previous works. This operator has the physical meaning of the sub-eikonal (covariant) phase: its contribution to helicity evolution is shown to be proportional to another sub-eikonal operator, ${}_D{}^{i} {}_D{}^{\leftarrow i}$, which is related to the Jaffe-Manohar polarized gluon distribution. In this work we include this new operator into small-x helicity evolution, and construct novel evolution equations mixing all three operators (${}_D{}^{i} {}_D{}^{\leftarrow i}$, F 12 , and $\overline{\psi}\gamma$ + γ 5 ψ), generalizing the results of . We also construct closed double-logarithmic evolution equations in the large-N c and large-N c &N f limits, with N c and N f the numbers of quark colors and flavors, respectively. Solving the large-N c equations numerically we obtain the following small-x asymptotics of the quark and gluon helicity distributions ΔΣ and ΔG, along with the g 1 structure function, $$ \Delta \Sigma \left(x,{Q}^2\right)\sim \Delta G\left(x,{Q}^2\right)\sim {g}_1\left(x,{Q}^2\right)\sim {\left(\frac{1}{x}\right)}^{3.66\sqrt{\frac{\alpha_s{N}_c}{2\pi }}} $$ in complete agreement with the earlier work by Bartels, Ermolaev and Ryskin.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Solid-State Transformation of Uranyl Peroxide Materials through High-Level Irradiation

The solid-state transformation of sodium uranyl triperoxide (Na 4 (UO 2 )(O 2 ) 3 ·9H 2 O, NaUT) to sodium uranyl tricarbonate (Na 4 (UO 2 )(CO 3 ) 3 ) by radiolysis was observed for the first time. The exposure of NaUT to 3 MGy gamma irradiation resulted in partial breakdown of the peroxides forming a mixed peroxide and carbonate species. The effects of He-ion irradiation on NaUT were also investigated up to 225 MGy using both hydrated argon and dry argon. The complete conversion to the uranyl tricarbonate phase by 56 MGy was done using hydrated argon, while dry argon did not fully convert showing the importance of water in the system. He-ion irradiated NaUT samples all convert to the tricarbonate phase with time in air post radiation exposure. This transition was monitored via Raman spectroscopy, infrared spectroscopy (IR), and powder X-ray diffraction (PXRD) to further confirm the identity of the final product as the sodium uranyl tricarbonate, čejkaite. Furthermore, this transformation outlines a mechanism for the mobility of uranyl in natural environments and in the Hanford tanks.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Positron Emission Intensity in the Decay of 86 gY for Use in Dosimetry Studies

The β + -emitting radionuclide 86 gY (t 1/2 = 14.7 h) forms a matched-pair with the β – -emitting therapeutic radionuclide 90Y (t 1/2 = 2.7 d) for theranostic application in medicine. This approach demands a precise knowledge of the positron emission probability of the PET nuclide which was until recently rather uncertain for 86 gY. In this work, an 86 gY source of high radionuclidic purity was prepared and a direct measurement of the positron emission intensity per 100 decay of the parent (hereafter “positron emission intensity”) was performed using high-resolution HPGe detector γ-ray spectroscopy. The electron capture intensity was also determined as an additional check by measuring the K α and K β X-rays of energies 14.1 and 15.8 keV, respectively, using a low energy HPGe detector. From those measurements, normalized values of 27.2 ± 2.0% for β + -emission and 72.8 ± 2.0% for EC were obtained. These results are in excellent agreement with values recently reported in the literature based on a detailed decay scheme study.

61 RADIATION PROTECTION AND DOSIMETRY↗