Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “WIRING SYSTEM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 793 records · Page 44

A free-standing wire scattering technique to monitor calibration variations of the DIII-D density profile reflectometer

Real-time phase calibration of the ITER profile reflectometer is essential due to the long plasma duration and expected waveguide path length changes during a discharge. Progress has been recently made in addressing this issue by employing a phase calibration technique on DIII-D that monitors calibration variations that occur during each plasma discharge. By installing a thin free-standing metallic wire (1 mm diameter) near the end of the overmoded waveguide transmission system (oriented perpendicular to the waveguide axis), the round-trip phase shift from the wire is detected simultaneously with the plasma phase shifts. Variations in the reflectometer round trip path length (-26 m) are then calculated after each DIII-D plasma discharge, allowing the calibration phase to be accurately monitored and updated. The round-trip reflectometer path length is observed to vary by -3 mm (root mean square value) during a typical DIII-D discharge. Using the variations in calibration phase, the density profile measurement accuracy can be improved. Since the wire retro-reflected power is -0.01 of the plasma signal, minimal effect is observed on the reflected signal from the plasma. Importantly, through a suitable choice in wire diameter, the calibration signal can be made approximately independent of the V-band reflectometer launch polarization. Furthermore, this is particularly important on DIII-D since orthogonal X- and O-mode polarized beams are coupled into the same transmission waveguide and launch antenna.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Heliopause Electrostatic Rapid Transit System (HERTS)

A recent six month investigation focused on: "Determining the benefits of propelling a scientific spacecraft by an 'Electric Sail' propulsion system to the edge of our solar system (the Heliopause), a distance of 100 to 120 AU, in ten years or less" has recently been completed by the Advance Concepts Office at NASA's MSFC. The concept investigated has been named the Heliopause Electrostatic Rapid Transit System (HERTS) by the MSFC team. The HERTS is a revolutionary propellant-less propulsion concept that is ideal for deep space missions to the Outer Planets, Heliopause, and beyond. It is unique in that it uses momentum exchange from naturally occurring solar wind protons to propel a spacecraft within the heliosphere. The propulsion system consists of an array of electrically positively-biased wires that extend outward 20 km from a rotating (one revolution per hour) spacecraft. It was determined that the HERTS system can accelerate a spacecraft to velocities as much as two to three times that possible by any realistic extrapolation of current state-of-the-art propulsion technologies- including solar electric and solar sail propulsion systems. The data produced show that a scientific spacecraft could reach distances of 100AU in less than 10 years. Moreover, it can be reasonably expected that this system could be developed within a decade and provide meaningful Heliophysics Science and Outer Planetary Science returns in the 2025-2035 timeframe.

Wiegmann, Bruce M.↗

A Novel Data System for Verification of Internal Parameters of Motor Design

Three major obstacles have limited the amount of information that can be obtained from inside an operating solid rocket motor. The first is a safety issue due to the presence of live propellant interacting with classical, electrical instrumentation. The second is a pressure vessel feed through risk arising from bringing a large number of wires through the rocket motor wall safely. The third is an attachment/protection issue associated with connecting gages to live propellant. Thiokol has developed a highly miniaturized, networked, electrically isolated data system that has safely delivered information from classical, electrical instrumentation (even on the burning propellant surface) to the outside world. This system requires only four wires to deliver 80 channels of data at 2300 samples/second/channel. The feed through leak path risk is massively reduced from the current situation where each gage requires at least three pressure vessel wire penetrations. The external electrical isolation of the system is better than that of the propellant itself. This paper describes the new system.

Smith, Doug↗

Dosimetric characterization of Ir-192 LDR elongated sources

Ir-192 wires have been used in low-dose-rate brachytherapy for many years. Commercially available treatment planning systems approximate the dose rate distribution of the straight or curved wires applying the superposition principle using one of the following methods: (i) The wire is modeled as a set of point sources, (ii) the wire is modeled as a set of small straight segment wires, (iii) the values of the parameters and functions of the American Association of Physicists in Medicine (AAPM) Task Group 43 protocol are obtained for wire lengths between 3 and 7 cm assuming some simplifications. The dose rate distributions obtained using these methods for linear wires of different lengths and U-shaped wires present significant deviations compared to those obtained by Monte Carlo. In the present study we propose a new method to model {sup 192}Ir wires of any length and shape, named the Two Lengths based Segmented method. This method uses the formalism stated in the AAPM Task Group 43 protocol for two straight wires only, 0.5 and 1 cm, to obtain the dose rate distribution around wires of any length (down to 0.3 cm and up to 10 cm) improving on the results of the aforementioned ones. This method can easily be applied to dose calculations around other wires, such as Pd-103 ones.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

RSRA flight control and stabilization

Handling qualities of the RSRA (rotor systems research aircraft), a special test vehicle with optional configurations (forewings, removable horizontal tailplanes, main rotor, tail rotor, and twin engines for forward flight all removable), are described. The aircraft can be fitted to fly as a conventional rotary-wing aircraft, fixed-wing aircraft, or compound helicopter, and is designed for testing existing and future rotor systems in flight. Controls include full-authority fly-by-wire controls and mechanical controls for rotary wing and for fixed wing. Stability augmentation, rotor test measurement systems, variable center of gravity capability, and rotor loading potential of the RSRA are also described.

Linden, A. W.↗

Electrostatic protection of the solar power satellite and rectenna. Part 2: Lightning protection of the rectenna

Computer simulations and laboratory tests were used to evaluate the hazard posed by lightning flashes to ground on the Solar Power Satellite rectenna and to make recommendations on a lightning protection system for the rectenna. The distribution of lightning over the lower 48 of the continental United States was determined, as were the interactions of lightning with the rectenna and the modes in which those interactions could damage the rectenna. Lightning protection was both required and feasible. Several systems of lightning protection were considered and evaluated. These included two systems that employed lightning rods of different lengths and placed on top of the rectenna's billboards and a third, distribution companies; it consists of short lightning rods all along the length of each billboard that are connected by a horizontal wire above the billboard. The distributed lightning protection system afforded greater protection than the other systems considered and was easier to integrate into the rectenna's structural design.

Source record↗

Simple synthesis of ultra-long Ag{sub 2}Te nanowires through solvothermal co-reduction method

Ultra-long single crystal {beta}-Ag{sub 2}Te nanowires with the diameter of about 300 nm were fabricated through a solvothermal route in ethylene glycol (EG) system without any template. The long single crystal wires were curves, with high purity, well-crystallized, and dislocation-free and characterized by using X-ray powder diffraction (XRD), Differential scanning calorimetry (DSC) analysis, X-ray photoelectron spectroscope (XPS), field emission scanning electron microscopy (FE-SEM), transmission electron microscopy (TEM) and high-resolution transmission microscopy (HRTEM). The detailed topotactic transformation process from particles into single crystal wires was studied. Furthermore, the electrical conductivity and Seebeck coefficient have been systematically studied between 300 and 600 K. - Graphical abstract: Ultra-long single crystal {beta}-Ag{sub 2}Te nanowires with the diameter of about 300 nm were fabricated by the solvothermal route in ethylene glycol (EG) system without any template. The diagram displays the variation of the phases and morphologies of products with different reaction time.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Soft X-ray astronomy proportional counter electronics

The X-ray multiwire proportional counter is designed to measure cosmic X-ray fluxes at sounding rocket altitudes in the energy range of 0.1 to 10 keV. Four instruments will be launched in a Black Brant 4 rocket employing different combinations of detector windows and gas. The detector is constructed with two layers of twelve cells. A columnator is mounted on the face of one layer whose cells are wired together alternately to form two main detector sections. The electronics and gas regulation systems are mounted on the face of the second layer whose cells are wired together to form one anticoincidence detector section. Normally X-rays will have short ionization paths in only one of the main detector cells at a time and won't enter the anticoincidence detector cells. To distinguish between X-rays and charged particles, the instrument includes a coincidence discriminator, an anticoincidence discriminator, and a pulse rise time discriminator.

Gardner, W. R.↗

Readout Noise of Digital Frequency Multiplexed TES Detectors for CUPID

The superconducting transition-edge sensor (TES) detectors have been the standard in cosmic microwave background (CMB) experiments for almost two decades and are now being adapted for use in nuclear physics, such as neutrinoless double beta decay searches. In this article, we focus on a new high-bandwidth frequency multiplexed TES readout system developed for CUPID, a neutrinoless double beta decay experiment that will replace CUORE. In order to achieve the high energy resolution requirements for CUPID, the readout noise of the system must be kept to a minimum. Low TES operating resistance and long wiring between the readout SQUID and the warm electronics are needed for CUPID, prompting a careful consideration of the design parameters of this application of frequency multiplexing. In this work, we characterize the readout noise of the newly designed frequency multiplexed TES readout system for CUPID and construct a noise model to understand it. Here, we find that current sharing between the SQUID coil impedance and other branches of the circuit, as well as the long output wiring, worsen the readout noise of the system. To meet noise requirements, a SQUID with a low input inductance, high transimpedance, and/or low dynamic impedance is needed, and the wiring capacitance should be kept as small as possible. Alternatively, the option of adding a cryogenic low-noise amplifier at the output of the SQUID should be explored.

CUPID↗

CJ concept for advanced aircraft wiring

The techniques and hardware are described which were developed for facilitating the use of flexible flat conductor cable (FFCC) in commercial air transports. The system was designed as an evolutionary transition from the current round wire harnessing to the use of FFCC harnesses. The equipment discussed includes the pressure crimp barrel designed for terminating FFCC, reel-fed applicator, cable connectors and adaptors, and equipment racks.

Redslob, J.↗

Attachment of lead wires to thin film thermocouples mounted on high temperature materials using the parallel gap welding process

Parallel gap resistance welding was used to attach lead wires to sputtered thin film sensors. Ranges of optimum welding parameters to produce an acceptable weld were determined. The thin film sensors were Pt13Rh/Pt thermocouples; they were mounted on substrates of MCrAlY-coated superalloys, aluminum oxide, silicon carbide and silicon nitride. The entire sensor system is designed to be used on aircraft engine parts. These sensor systems, including the thin-film-to-lead-wire connectors, were tested to 1000 C.

Holanda, Raymond↗

Orbiting transmitter and antenna for spaceborne communications at ELF/VLF to submerged submarines

An orbital emplacement for the transmitter and the antenna of a communications link at ELF (30 to 300 Hz) and VLF (3 kHz to 30 kHz) to submerged submarines has been considered since the very inception of the space age. However, only recently has space technology reached a sufficient level of maturity for system designers to undertake serious studies of this link configuration. The optimistic outlook stems from recent space technology developments, such as the design and construction by NASA of long orbiting tethers, and the testing, onboard Shuttle Orbiter ATLANTIS, of the first spaceborne 20 km metal wire. This is known as the Tethered Satellite System-1 (TSS-1), a space mission that might be possibly followed by other flights, with tether lengths that could reach 100 km. Once deployed at a height of, say, 300 km, from a Shuttle Orbiter, or from another suitable platform, a long, thin tether aligns itself along the local vertical by virtue of the gradient of the Earth gravity field. If made of metal, the tether can function as a VED (Vertical Electric Dipole) transmitting antenna at ELF and VLF.

Bannister, P. R.↗

Reaction control system helium pressure regulator filter failure

The failure analysis of the command module reaction control system helium pressure regulators revealed that the filter element end caps were bulged by the helium pressure surge during activation. Some end caps may bulge and also some wire separation may occur during command module reaction control system activations; however, system performance should not be affected. The reaction control system design is acceptable and no change in hardware, system, or activation procedures is required.

Source record↗

Spiral Development for Safeguards Instrumentation

Safeguards instrumentation is highly specialized, so a common approach in the US has been to develop initial prototypes for performance, operability and security within the US National Laboratories for the IAEA and then seek one or more commercial partners. Transfer of technology from US National Laboratories is a legal requirement for products that have the potential for mass production. Other important objectives include minimizing time to deployment and lifecycle cost, and optimizing product maintainability, sustainability and manufacturability. Unfortunately, the deployment of systems developed via this model has sometimes been seriously delayed or never adopted because of the difficulty of optimizing the significant parameters of the process between the public and private sectors. The authors suggest that forming an R&D partnership between a research laboratory and a commercial company much earlier in the process would provide significant advantages. The present US practice leads to unnecessary expenditures during the early R&D phase since many decisions are made based on research needs that are counterproductive for commercialization and manufacturability. If the ultimate goal of the project is to produce a reliable and cost effective commercial product, the commercial input is needed early and often. The new “model” of developing systems in a closer collaboration with the private sector, in a spiral “Commercialization by Design” approach, should also limit the long term financial mortgages that Member States frequently experience with respect to safeguards instrumentation development using the present process. As a concrete example, the potential for incorporating Wire Integrity Verification Technology into the iCobra Reader System is discussed.

Koskelo, M.↗

Changes in Polymeric Tether Properties Due to Atomic Oxygen

The Propulsive Small Expendable Deployer System (ProSEDS) mission is designed to provide an on-orbit demonstration of the electrodynamic propulsion capabilities of tethers in space. The ProSEDS experiment will be a secondary payload on a Delta II unmanned expendable booster. A 5-km conductive tether is attached to the Delta II second stage and collects current fiom the low Earth orbit (LEO) plasma to facilitate de-orbit of the spent stage. The conductive tether is attached to a 10-km non-conductive tether, which is then attached to an endmass containing several scientific instruments. Atomic oxygen (AO) erodes most organic materials. As the orbit of the Delta II second stage decas, the AO flux (atoms/sq cm sec) increases. A nominal AO fluence of 1 x l0(exp 21) atoms/sq cm was agreed upon by the investigators as an adequate level for evaluating the performance of the tether materials. A test series was performed to determine the effect of atomic oxygen (AO) on the mechanical integrity and possible strength loss of ProSEDS tether materials. The tether materials in this study were Dyneema, an ultra-high molecular weight polyethylene material used as the non-conducting portion of the ProSEDS tether, and the Kevlar core strength fiber used in the conductive tether. Samples of Dyneema and Kevlar were exposed to various levels of atomic oxygen up to 1.07 x 10(exp 21) atoms/sq cm in the Marshall Space Flight Center Atomic Oxygen Beam Facility (AOBF). Changes in mass were noted after AO exposure. The tethers were then tensile-tested until failure. AO affected both the Dyneema and Kevlar tether material strength. Dyneema exposed to 1.07 x 10(exp 21) atoms/sq cm of atomic oxygen failed due to normal handling when removed fiom the AOBF and was not tensile-tested. Another test series was performed to determine the effect of AO on the electrical properties of the ProSEDS conductive tether. The conductive tether consists of seven individually coated strands of 28 AWG 1350-0 aluminum wire. The conductive coating, developed by Triton Systems, Inc., is a mix of polyanaline and COR, a clear AO-resistant polymer.

Finckenor, Miria M.↗

Integrated Application of Active Controls (IAAC) technology to an advanced subsonic transpot project-demonstration act system definition

The 1985 ACT airplane is the Final Active Controls Technology (ACT) Airplane with the addition of three-axis fly by wire. Thus it retains all the efficiency features of the full ACT system plus the weight and cost savings accruing from deletion of the mechanical control system. The control system implements the full IAAC spectrum of active controls except flutter-mode control, judged essentially nonbeneficial, and incorporates new control surfaces called flaperons to make the most of wing-load alleviation. This redundant electronic system is conservatively designed to preserve the extreme reliability required of crucial short-period pitch augmentation, which provides more than half of the fuel savings.

Hanks, G. W.↗

Thermal management of long-length HTS cable systems

Projections of electric power production suggest a major shift to renewables, such as wind and solar, which will be in remote locations where massive quantities of power are available. One solution for transmitting this power over long distances to load centers is direct current (dc), high temperature superconducting (HTS) cables. Electric transmission via dc cables promises to be effective because of the low-loss, highcurrent- carrying capability of HTS wire at cryogenic temperatures. However, the thermal management system for the cable must be carefully designed to achieve reliable and energyefficient operation. Here we extend the analysis of a superconducting dc cable concept proposed by the Electric Power Research Institute (EPRI), which has one stream of liquid nitrogen flowing in a cryogenic enclosure that includes the power cable, and a separate return tube for the nitrogen. Refrigeration stations positioned every 10 to 20 km cool both nitrogen streams. Both go and return lines are contained in a single vacuum/cryogenic envelope. Other coolants, including gaseous helium and gaseous hydrogen, could provide potential advantages, though they bring some technical challenges to the operation of long-length HTS dc cable systems. A discussion of the heat produced in superconducting cables and a system to remove the heat are discussed. Also, an analysis of the use of various cryogenic fluids in long-distance HTS power cables is presented.

08 HYDROGEN↗