Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Volume Constraint”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 793 records · Page 44

Evaluation of routing and scheduling considerations for possible future commercial hypersonic transport aircraft

Travel markets which would be served by high speed commercial transport aircraft and the ability of the airlines to schedule and route the aircraft in a way that would achieve good daily utilization and productivity are examined. The following areas are considered: (1) identification of the major long-haul city pairs that would most likely demand nonstop service; (2) selection of flight tracks observing alternative sonic boom restrictions; (3) estimation of flight times for all city pairs for the various sonic boom constraints; (4) impact of airport curfews on possible departure and arrival schedules; (5) projection of passenger traffic volumes on the selected city pairs; and (6) potential daily utilization and aircraft productivity.

Feir, J. B.↗

A method and data for video monitor sizing

The paper outlines an approach consisting of using analytical methods and empirical data to determine monitor size constraints based on the human operator's CRT viewing requirements in a context where panel space and volume considerations for the Space Shuttle aft cabin constrain the size of the monitor to be used. Two cases are examined: remote scene imaging and alphanumeric character display. The central parameter used to constrain monitor size is the ratio M/L where M is the monitor dimension and L the viewing distance. The study is restricted largely to 525 line video systems having an SNR of 32 db and bandwidth of 4.5 MHz. Degradation in these parameters would require changes in the empirically determined visual angle constants presented. The data and methods described are considered to apply to cases where operators are required to view via TV target objects which are well differentiated from the background and where the background is relatively sparse. It is also necessary to identify the critical target dimensions and cues.

Kirkpatrick, M., III↗

Human Research Program Advanced Exercise Concepts (AEC) Overview

Exercise countermeasures provide benefits that are crucial for successful human spaceflight, to mitigate the spaceflight physiological deconditioning which occurs during exposure to microgravity. The NASA Human Research Program (HRP) within the Human Exploration and Operations Mission Directorate (HEOMD) is managing next generation Advanced Exercise Concepts (AEC) requirements development and candidate technology maturation to Technology Readiness Level (TRL) 7 (ground prototyping and flight demonstration) for all exploration mission profiles from Multi Purpose Crew Vehicle (MPCV) Exploration Missions (up to 21 day duration) to Mars Transit (up to 1000 day duration) missions. These validated and optimized exercise countermeasures systems will be provided to the ISS Program and MPCV Program for subsequent flight development and operations. The International Space Station (ISS) currently has three major pieces of operational exercise countermeasures hardware: the Advanced Resistive Exercise Device (ARED), the second-generation (T2) treadmill, and the cycle ergometer with vibration isolation system (CEVIS). This suite of exercise countermeasures hardware serves as a benchmark and is a vast improvement over previous generations of countermeasures hardware, providing both aerobic and resistive exercise for the crew. However, vehicle and resource constraints for future exploration missions beyond low Earth orbit will require that the exercise countermeasures hardware mass, volume, and power be minimized, while preserving the current ISS capabilities or even enhancing these exercise capabilities directed at mission specific physiological functional performance and medical standards requirements. Further, mission-specific considerations such as preservation of sensorimotor function, autonomous and adaptable operation, integration with medical data systems, rehabilitation, and in-flight monitoring and feedback are being developed for integration with the exercise countermeasures systems. Numerous technologies have been considered and evaluated against HRP-approved functional device requirements for these extreme mission profiles, and include wearable sensors, exoskeletons, flywheel, pneumatic, and closed-loop microprocessor controlled motor driven systems. Each technology has unique advantages and disadvantages. The Advanced Exercise Concepts project oversees development of candidate next generation exercise countermeasures hardware, performs trade studies of current and state of the art exercise technologies, manages and supports candidate systems physiological evaluations with human test subjects on the ground, in flight analogs and flight. The near term goal is evaluation of candidate systems in flight, culminating in an integrated candidate next generation exercise countermeasures suite on the ISS which coalesces research findings from HRP disciplines in the areas of exercise performance for muscle, bone, cardiovascular, sensorimotor, behavioral health, and nutrition for optimal benefit to the crew.

Countermeasures↗

Determining the Transport of Magnetic Helicity and Free Energy in the Sun's Atmosphere

The most important factors determining solar coronal activity are believed to be the availability of magnetic free energy and the constraint of magnetic helicity conservation. Direct measurements of the helicity and magnetic free energy in the coronal volume are difficult, but their values may be estimated from measurements of the helicity and free energy transport rates through the photosphere. We examine these transport rates for a topologically open system such as the corona, in which the magnetic fields have a nonzero normal component at the boundaries, and derive a new formula for the helicity transport rate at the boundaries. In addition, we derive new expressions for helicity transport due to flux emergence/submergence versus photospheric horizontal motions. The key feature o four formulas is that they are manifestly gauge invariant. Our results are somewhat counterintuitive in that only the lamellar electric field produced by the surface potential transports helicity across boundaries, and the solenoidal electric field produced by a surface stream function does not contribute to the helicity transport. We discuss the physical interpretation of this result. Furthermore, we derive an expression for the free energy transport rate and show that a necessary condition for free energy transport across a boundary is the presence of a closed magnetic field at the surface, indicating that there are current systems within the volume. We discuss the implications of these results for using photospheric vector magnetic and velocity field measurements to derive the solar coronal helicity and magnetic free energy, which can then be used to constrain and drive models for coronal activity.

Schuck, Peter W.↗

Localization of Binary Black Hole Mergers with Known Inclination

The localization of stellar-mass binary black hole mergers using gravitational waves is critical in understanding the properties of the binaries' host galaxies, observing possible electromagnetic emission from the mergers, or using them as a cosmological distance ladder. The precision of this localization can be substantially increased with prior astrophysical information about the binary system. In particular, constraining the inclination of the binary can reduce the distance uncertainty of the source. Here we present the first realistic set of localizations for binary black hole mergers, including different prior constraints on the binaries' inclinations. We find that prior information on the inclination can reduce the localization volume by a factor of 3. We discuss two astrophysical scenarios of interest: (i) follow-up searches for beamed electromagnetic/neutrino counterparts and (ii) mergers in the accretion disks of active galactic nuclei.

Corley, K. Rainer↗

Fundamental Problems In SmallSat Concept Development

The standardization of launch opportunities as secondary payloads, coupled with the miniaturization of digital electronics due to Moore’s law, has enabled a new class of space missions at greatly reduced costs – SmallSat missions. Unfortunately, the desires of concept developers are often in conflict with the limited technical budgets afforded within the constraints of a SmallSat mission. Chief amongst these limited technical budgets, ironically, are the limited mass and volume budgets that enable them in the first place.Mass and volume budgets are consumed in closure of the other technical budgets in space systems: science error budgets, delta-v and propellent budgets, power and energy budgets, and thermal budgets, to name a few. Most aspects of these budgets are unaffected by the miniaturization of digital electronics enabled by modern physics, but are instead governed by the laws of classical physics, worked out by Europeans, long since dead.The fundamental laws of classical physics provide the couplings between these budgets, and provide a way to help potential users realize the practical limitations inherent in SmallSat systems. Understanding the fundamental limitations better positions concept developers to find innovative solutions with these systems and not inefficiently pursue infeasible approaches to their needs.

Austin, Alexander↗

Performance Considerations for Alternatives to 3He-Based Neutron Counters for Safeguards Applications

Worldwide, significant effort has been expended to develop replacement technologies for 3He-filled proportional counters used as neutron detectors and employed extensively in applications as diverse as Homeland Security portal monitoring to fundamental scientific research. Far less attention has been paid to the specific needs of safeguards measurement systems to meet mission objectives such as international obligations under the Nuclear Non-Proliferation Treaty. The measurement configuration, operational environments, and performance requirements for the typical safeguards assay system are sufficiently different from those of other applications that the new generation of neutron detectors is not generally suitable for use in demanding safeguards applications. To illustrate the performance needs for any viable replacement neutron detector technology, the operational constraints for several typical safeguards measurement systems are considered. Key attributes include achieving adequate efficiency per unit volume and minimal parasitic losses, along with gamma-ray immunity in a unit with high reliability and low maintenance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Inflation and Early Dark Energy with a Stage II Hydrogen Intensity Mapping experiment

This white paper envisions a revolutionary post-DESI, post-LSST dark energy program based on intensity mapping of the redshifted 21 cm emission line from neutral hydrogen out to redshift z ~ 6 at radio frequencies. The proposed intensity mapping survey has the unique capability to quadruple the volume of the Universe surveyed by optical programs, provide a percent-level measurement of the expansion history to z ~ 6, open a window to explore physics beyond the concordance {\\Lambda}CDM model, and to significantly improve the precision on standard cosmological parameters. In addition, characterization of dark energy and new physics will be powerfully enhanced by cross-correlations with optical surveys and cosmic microwave background measurements. The rich dataset obtained by the proposed intensity mapping instrument will be simultaneously useful in exploring the time-domain physics of fast radio transients and pulsars, potentially in live "multi-messenger" coincidence with other observatories. The core Dark Energy/Inflation science advances enabled by this program are the following: i) Measure the expansion history of the universe in the pre-acceleration era at the same precision as at lower redshifts, providing an unexplored window for new physics. ii) Observe, or constrain, the presence of inflationary relics in the primordial power spectrum, improving existing constraints by an order of magnitude; iii) Observe, or constrain, primordial non-Gaussianity with unprecedented precision, improving constraints on several key numbers by an order of magnitude. Detailed mapping of the enormous, and still largely unexplored, volume of space observable in the mid-redshift (z ~ 2 - 6) range will thus provide unprecedented information on fundamental questions of vacuum energy and early-universe physics.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-T-355: A Comparative Study of Robotic and Linac-Based Stereotactitc Body Radiation Therapy for Lumbar Spinal Tumors

Purpose: Dosimetrically compare CyberKnife (CK) and linac-based (LB) stereotactic body radiotherapy (SBRT) plans for lumbar spine. Methods: Ten patient plans with lumbar spine tumors treated with CK were selected and retrospectively optimized using three techniques: CK, volumetric modulated arc (VMAT, three arcs), and 9-field-intensity modulated radiotherapy (IMRT). For the LB plans, the target volume was expanded by 1mm to accommodate additional uncertainty in patient positioning. All plans were optimized to a prescription dose of 27Gy in 3 fractions covering 90% of the PTV. If the dose constraints to the cauda equina (cauda) were not met, the prescription dose was lowered to 24Gy. Parameters evaluated included Paddick Conformity-Index (CI) and Gradient-Index (GI). A two-tailed paired t-test was used to establish statistically significant differences in cauda doses. Results: Target volumes for LB plans were on average 38% larger. In terms of the indices, the closer the index values to unity the steeper the dose falloff and the higher the dose conformity to the target. The results showed that LB plans were in general statistically superior to CK plans. The IMRT plan showed the best average gradient index of 2.995, with VMAT and CK GI values of 3.699 and 5.476, respectively. Similarly, the same trend occurs with the average CI results: 0.821, 0.814, and 0.758, corresponding to IMRT, VMAT, and CK. Notably, in one CK plan the target dose was reduced to 24Gy to meet cauda constraints. Additionally, there was a statistically significant dose difference for the cauda between the CK and LB plans. Conclusion: This study demonstrates that LB plans for lumbar spine SBRT can be as effective or even better than CK plans. Despite the expansion of the target volume, the LB plans did not demonstrate dosimetric inferiority. The LB plans Resultin 2-to-3 fold decrease of treatment time.

60 APPLIED LIFE SCIENCES↗

Instability analysis and free volume simulations of shear band directions and arrangements in notched metallic glasses

As a commonly used method to enhance the ductility in bulk metallic glasses (BMGs), the introduction of geometric constraints blocks and confines the propagation of the shear bands, reduces the degree of plastic strain on each shear band so that the catastrophic failure is prevented or delayed, and promotes the formation of multiple shear bands. The clustering of multiple shear bands near notches is often interpreted as the reason for improved ductility. Experimental works on the shear band arrangements in notched metallic glasses have been extensively carried out, but a systematic theoretical study is lacking. Using instability theory that predicts the onset of strain localization and the free-volume- based nite element simulations that predict the evolution of shear bands, this work reveals various categories of shear band arrangements in double edge notched BMGs with respect to the mode mixity of the applied stress fields. In conclusion, a mechanistic explanation is thus provided to a number of related experiments and especially the correlation between various types of shear bands and the stress state.

36 MATERIALS SCIENCE↗

Observational constraints on early dark energy

In this paper, we review and update constraints on the Early Dark Energy (EDE) model from cosmological data sets, in particular Planck PR3 and PR4 cosmic microwave background (CMB) data and large-scale structure (LSS) data sets including galaxy clustering and weak lensing data from the Dark Energy Survey, Subaru Hyper Suprime-Cam and KiDS+VIKING-450, as well as BOSS/eBOSS galaxy clustering and Lyman-[Formula: see text] forest data. We detail the fit to CMB data, and perform the first analyses of EDE using the CAMSPEC and Hillipop likelihoods for Planck CMB data, rather than Plik, both of which yield a tighter upper bound on the allowed EDE fraction than that found with Plik. We then supplement CMB data with LSS data in a series of new analyses. All these analyses are concordant in their Bayesian preference for [Formula: see text]CDM over EDE, as indicated by marginalized posterior distributions. We perform a series of tests of the impact of priors in these results, and compare with frequentist analyses based on the profile likelihood, finding qualitative agreement with the Bayesian results. All these tests suggest prior volume effects are not a determining factor in analyses of EDE. This work provides both a review of existing constraints and several new analyses.

Astronomy & Astrophysics↗

A Positive-Definite, WENO-Limited, High-Order Finite Volume Solver for 2-D Transport on the Cubed Sphere Using an ADER Time Discretization

Modern computer architectures reward added computation if it reduces algorithmic dependence, reduces data movement, increases accuracy/robustness, and improves memory accesses. The driving motive for this study is to develop a numerical algorithm that respects these constraints while improving accuracy and robustness. This study introduces the ADER-DT (Arbitrary DERivatives in time and space-differential transform) time discretization to positive-definite, weighted essentially nonoscillatory (WENO)-limited, finite volume transport on the cubed sphere in lieu of semidiscrete integrators. The cost of the ADER-DT algorithm is significantly improved from previous implementations without affecting accuracy. A new function-based WENO implementation is also detailed for use with the ADER-DT time discretization. While ADER-DT costs about 1.5 times more than a fourth-order, five-stage strong stability preserving Runge-Kutta (SSPRK4) method, it is far more computationally dense (which is advantageous on accelerators such as graphics processing units), and it has a larger effective maximum stable time step. ADER-DT errors converge more quickly with grid refinement than SSPRK4, giving 6.5 times less error in the L ∞ norm than SSPRK4 at the highest refinement level for smooth data. For nonsmooth data, ADER-DT resolves C 0 discontinuities more sharply. For a complex flow field, ADER exhibits less phase error than SSPRK4. In conclusion, improving both accuracy and robustness as well as better respecting modern computational efficiency requirements, we believe the method presented herein is competitive for efficiently transporting tracers over the sphere for applications targeting modern computing architectures.

97 MATHEMATICS AND COMPUTING↗

Background based Gaussian mixture model lesion segmentation in PET

Purpose: Quantitative {sup 18}F-fluorodeoxyglucose positron emission tomography is limited by the uncertainty in lesion delineation due to poor SNR, low resolution, and partial volume effects, subsequently impacting oncological assessment, treatment planning, and follow-up. The present work develops and validates a segmentation algorithm based on statistical clustering. The introduction of constraints based on background features and contiguity priors is expected to improve robustness vs clinical image characteristics such as lesion dimension, noise, and contrast level. Methods: An eight-class Gaussian mixture model (GMM) clustering algorithm was modified by constraining the mean and variance parameters of four background classes according to the previous analysis of a lesion-free background volume of interest (background modeling). Hence, expectation maximization operated only on the four classes dedicated to lesion detection. To favor the segmentation of connected objects, a further variant was introduced by inserting priors relevant to the classification of neighbors. The algorithm was applied to simulated datasets and acquired phantom data. Feasibility and robustness toward initialization were assessed on a clinical dataset manually contoured by two expert clinicians. Comparisons were performed with respect to a standard eight-class GMM algorithm and to four different state-of-the-art methods in terms of volume error (VE), Dice index, classification error (CE), and Hausdorff distance (HD). Results: The proposed GMM segmentation with background modeling outperformed standard GMM and all the other tested methods. Medians of accuracy indexes were VE <3%, Dice >0.88, CE <0.25, and HD <1.2 in simulations; VE <23%, Dice >0.74, CE <0.43, and HD <1.77 in phantom data. Robustness toward image statistic changes (±15%) was shown by the low index changes: <26% for VE, <17% for Dice, and <15% for CE. Finally, robustness toward the user-dependent volume initialization was demonstrated. The inclusion of the spatial prior improved segmentation accuracy only for lesions surrounded by heterogeneous background: in the relevant simulation subset, the median VE significantly decreased from 13% to 7%. Results on clinical data were found in accordance with simulations, with absolute VE <7%, Dice >0.85, CE <0.30, and HD <0.81. Conclusions: The sole introduction of constraints based on background modeling outperformed standard GMM and the other tested algorithms. Insertion of a spatial prior improved the accuracy for realistic cases of objects in heterogeneous backgrounds. Moreover, robustness against initialization supports the applicability in a clinical setting. In conclusion, application-driven constraints can generally improve the capabilities of GMM and statistical clustering algorithms.

60 APPLIED LIFE SCIENCES↗

Reconstruction of 3D lung models from 2D planning data sets for Hodgkin's lymphoma patients using combined deformable image registration and navigator channels

Purpose: Late complications (cardiac toxicities, secondary lung, and breast cancer) remain a significant concern in the radiation treatment of Hodgkin's lymphoma (HL). To address this issue, predictive dose-risk models could potentially be used to estimate radiotherapy-related late toxicities. This study investigates the use of deformable image registration (DIR) and navigator channels (NCs) to reconstruct 3D lung models from 2D radiographic planning images, in order to retrospectively calculate the treatment dose exposure to HL patients treated with 2D planning, which are now experiencing late effects. Methods: Three-dimensional planning CT images of 52 current HL patients were acquired. 12 image sets were used to construct a male and a female population lung model. 23 ''Reference'' images were used to generate lung deformation adaptation templates, constructed by deforming the population model into each patient-specific lung geometry using a biomechanical-based DIR algorithm, MORFEUS. 17 ''Test'' patients were used to test the accuracy of the reconstruction technique by adapting existing templates using 2D digitally reconstructed radiographs. The adaptation process included three steps. First, a Reference patient was matched to a Test patient by thorax measurements. Second, four NCs (small regions of interest) were placed on the lung boundary to calculate 1D differences in lung edges. Third, the Reference lung model was adapted to the Test patient's lung using the 1D edge differences. The Reference-adapted Test model was then compared to the 3D lung contours of the actual Test patient by computing their percentage volume overlap (POL) and Dice coefficient. Results: The average percentage overlapping volumes and Dice coefficient expressed as a percentage between the adapted and actual Test models were found to be 89.2{+-}3.9% (Right lung=88.8%; Left lung=89.6%) and 89.3{+-}2.7% (Right=88.5%; Left=90.2%), respectively. Paired T-tests demonstrated that the volumetric reconstruction method made a statistically significant improvement to the population lung model shape (p<0.05). The error in the results were also comparable to the volume overlap difference observed between inhale and exhale lung volumes during free-breathing respiratory motion (POL:p=0.43; Dice:p=0.20), which implies that the accuracies of the reconstruction method are within breathing constraints and would not be the confining factor in estimating normal tissue dose exposure. Conclusions: The result findings show that the DIR-NC technique can achieve a high degree of reconstruction accuracy, and could be useful in approximating 3D dosimetric representations of historical 2D treatment. In turn, this could provide a better understanding of the biophysical relationship between dose-volume exposure and late term radiotherapy effects.

61 RADIATION PROTECTION AND DOSIMETRY↗

Level-Set Topology Optimization with Aeroelastic Constraints

Level-set topology optimization is used to design a wing considering skin buckling under static aeroelastic trim loading, as well as dynamic aeroelastic stability (flutter). The level-set function is defined over the entire 3D volume of a transport aircraft wing box. Therefore, the approach is not limited by any predefined structure and can explore novel configurations. The Sequential Linear Programming (SLP) level-set method is used to solve the constrained optimization problems. The proposed method is demonstrated using three problems with mass, linear buckling and flutter objective and/or constraints. A constraint aggregation method is used to handle multiple buckling constraints in the wing skins. A continuous flutter constraint formulation is used to handle difficulties arising from discontinuities in the design space caused by a switching of the critical flutter mode.

Dunning, Peter D.↗

Pore-Scale and Multiscale Numerical Simulation of Flow and Transport in a Laboratory-Scale Column

Pore-scale models are useful for studying relationships between fundamental processes and phenomena at larger (i.e., Darcy) scales. However, the size of domains that can be simulated with explicit pore-scale resolution is limited by computational and observational constraints. Direct numerical simulation of pore-scale flow and transport is typically performed on millimeter-scale volumes at which X-ray computed tomography (XCT), often used to characterize pore geometry, can achieve micrometer resolution. In contrast, the scale at which a continuum approximation of a porous medium is valid is usually larger, on the order of centimeters to decimeters. Furthermore, laboratory experiments that measure continuum properties are typically performed on decimeter-scale columns. At this scale, XCT resolution is coarse (tens to hundreds of micrometers) and prohibits characterization of small pores and grains. We performed simulations of pore-scale processes over a decimeter-scale volume of natural porous media with a wide range of grain sizes, and compared to results of column experiments using the same sample. Simulations were conducted using high-performance codes executed on a supercomputer. Two approaches to XCT image segmentation were evaluated, a binary (pores and solids) segmentation and a ternary segmentation that resolved a third category (porous solids with pores smaller than the imaged resolution). We used a mixed Stokes-Darcy simulation method to simulate the combination of Stokes flow in large open pores and Darcy-like flow in porous solid regions. Simulations based on the ternary segmentation provided results that were consistent with experimental observations, demonstrating our ability to successfully model pore-scale flow over a column-scale domain.

CFD↗

A trait syndrome ties cell morphology to glycolysis across the yeast subphylum

Co-variation of traits provides fundamental insights into constraints governing their evolution. An inverse correlation between glucose uptake rates (GURs) and cell surface area-to-volume (SA:V) ratios across 11 yeast species was recently reported. Here, we expand the analysis to 282 species to assess the generalizability of this correlation across Saccharomycotina yeasts and the contribution of shared evolutionary history to the co-variation of these traits. Using phylogenetic regression models, we found extracellular acidification rates (ECARs, used as a proxy for GURs) were weakly, but significantly, correlated with SA:V across Saccharomycotina. ECARs were also correlated with genome sizes and growth rates. Our findings support the reported correlation between GURs and SA:V ratios, but suggest other associated traits, including genome sizes. Specifically, yeasts that consume glucose faster tend to have lower SA:V, faster growth rates, and larger genomes, suggesting a trait syndrome governing several metabolic, genomic, and morphological traits across the yeast subphylum.

biological sciences↗