Uncertainty Quantification in Vibro-Acoustics Diagnosis of Alkali-Silica Reaction Degradation in Medium-Sized Concrete Samples

The objectives of this ongoing research project focus on health monitoring and data analytics of concrete slabs containing reactive aggregates and thus subjected to degradation due to alkali-silica reaction (ASR). A controlled concrete slab with four pockets of reactive aggregates (pure silica, wells, placitas, and spratt) was cast at Vanderbilt University and cured in representative conditions to accelerate degradation due to ASR. A set of four concrete samples were also cast and cured at the University of Alabama for ASR testing. Of these four samples, two slabs contained reactive aggregates while the other two had the non-reactive aggregate counterparts mixed throughout the samples. Vibro-acoustic testing was used on these slabs to locate ASR damage within the reactive samples. Vibro-acoustic modulation (VAM) is a vibration-based NDE method that utilizes signatures of nonlinear dynamic interactions on contact surfaces of crack or delamination damage to detect and localize the damage. VAM analysis was conducted on both the Vanderbilt and Alabama samples using multiple variables for damage detection and localization. The results from the data analysis of the vibro-acoustic testing on concrete slabs cured at Vanderbilt University and the University of Alabama are discussed in detail in this report. Results for damage localization are dependent on multiple variables used in the vibro-acoustic modulation experiments. A major focus of this report is to quantify the uncertainty in the diagnosis due to multiple factors and uncertainty sources. The uncertainty quantification methodology presented in this report was applied to VAM-based diagnosis and prognosis. However, the methodology is general, and is capable of being applied to multiple technique that collect spatially distributed data. Future work needs to investigate the incorporation of uncertainty quantification in developing a robust Prognostics and Health Management framework. Digital image correlation is a three-dimensional, full-field, optical NDE technique to measure contour, deformation, vibration, and strain. The application of the digital image correlation technique to study ASR-related degradation on a large concrete specimen at the University of Tennessee is discussed and observations are presented in this report.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Threshold ionization, structural isomers, and electronic states of M{sub 2}O{sub 2} (M = Sc, Y, and La)

M{sub 2}O{sub 2} (M = Sc, Y, and La) were synthesized in a pulsed laser-vaporization molecular beam source and studied by mass-analyzed threshold ionization (MATI) spectroscopy and ab initio calculations. Adiabatic ionization energies (AIEs) and several vibrational frequencies were measured accurately for the first time from the MATI spectra. Six possible structural isomers of M{sub 2}O{sub 2} were considered in the calculations and the three converged structures were used in the spectral analysis. A planar cyclic structure in D{sub 2h} point group was predicted to be the most stable one by the theory and observed by the experiment. The cyclic structure is formed by joining two MO{sub 2} fragments together through two shared oxygen atoms. In forming the ground state clusters, each metal atom loses two (n − 1)d electrons and as a result, has only one ns electron in the metal-based valence orbital. The ground electronic state of Sc{sub 2}O{sub 2} is {sup 1}A{sub g}, and those of Y{sub 2}O{sub 2} and La{sub 2}O{sub 2} are {sup 3}B{sub 1u}. Ionization of both {sup 1}A{sub g} and {sup 3}B{sub 1u} neutral states yields the {sup 2}A{sub g} ion state by removing one of the two ns electrons, and the resultant ion has a similar geometry to the neutral cluster. The AIEs of the clusters are 5.5752 (6), 5.2639 (6), 4.5795 (6) eV for M = Sc, Y, and La, respectively. The vibrational frequencies of the observed modes, including O-M and M-M stretches, are in the range of 200–800 cm{sup −1}.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

PVA and PEG functionalised LSMO nanoparticles for magnetic fluid hyperthermia application

La{sub 0.7}Sr{sub 0.3}MnO{sub 3} magnetic nanoparticles are synthesized by a solution combustion method and functionalised with polyvinyl alcohol and polyethylene glycol. The induction heating characteristics of coated magnetic nanoparticles (42 °C) were observed at a reasonably low concentration (5 mg/mL). Remarkably, coated magnetic nanoparticles exhibited a promisingly high specific absorption rate with varying magnetic field and constant frequency. The surface analysis is carried out by X-ray photoelectron spectroscopy. A reduction in the agglomeration of the particles was observed when the magnetic nanoparticles were functionalised with polyvinyl alcohol or polyethylene glycol and can be confirmed by transmission electron microscopy and dynamic light scattering studies. Vibrating sample magnetometer measurements indicate superparamagnetic behaviour at room temperature before and after coating. Colloidal stability revealed a considerably higher zeta potential value for coated system. In vitro cytotoxicity test of the magnetic nanoparticles indicates that coated nanoparticles have no significant effect on cell viability within the tested concentrations (1–5 mg mL{sup -1}) as compared to uncoated La{sub 0.7}Sr{sub 0.3}MnO{sub 3}. All these findings explore the potentiality of La{sub 0.7}Sr{sub 0.3}MnO{sub 3} nanoparticles for magnetic fluid hyperthermia. - Highlights: • Surface functionalization of LSMO nanoparticles — first time with PVA • Surface functionalization of LSMO nanoparticles — first time with PEG • BSA protein — first time used as dispersion medium for stability of LSMO nanoparticles • The heating ability observed at low concentration • Improved efficiency of magnetic fluid hyperthermia treatment with surfactants.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Room temperature multiferroic properties of (Fe{sub x}, Sr{sub 1−x})TiO{sub 3} thin films

This letter reports the structural, dielectric, ferroelectric, and magnetic properties of Fe substituted SrTiO{sub 3} thin films in room temperature. The structural data obtained from x-ray diffraction indicates that (Fe{sub x},Sr{sub 1−x})TiO{sub 3}, the so called FST, transforms from pseudocubic to tetragonal structures with increase of the Fe content in SrTiO{sub 3} thin films, featuring the ferroelectricity, while vibrating sample magnetometer measurements show magnetic hysteresis loops for the samples with low iron contents indicating their ferromagnetism. The characterized ferroelectricity and ferromagnetism confirms strong multiferroitism of the single phase FST thin films in room temperature. Also, an FST thin film metal-insulator-metal multiferroic capacitor has been fabricated and characterized in microwave frequencies between 10 MHz and 5 GHz. A capacitor based on Fe{sub 0.1}Sr{sub 0.9}TiO{sub 3} with a thickness of 260 nm shows a high electric tunability of 18.6% at 10 V and a maximum magnetodielectric value of 1.37% at 0.4 mT with a loss tangent of 0.021 at 1 GHz. This high tuning and low loss makes this material as a good candidate for frequency agile microwave devices such as tunable filters, phase shifters, and antennas.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Response of GAS payload (G345 and G347) temperatures to various orbiter flight attitudes

At the beginning of the Get-Away Special (GAS) flight program, the GAS Project flew a Flight Verification Payload on STS-3 to make measurements of the vibrations, acoustic and magnetic environments of the canister, and to obtain thermal profiles of internal and external components of the GAS system. These data were used to verify pre-flight thermal models of the GAS system and results have been published in a GSFC Technical Note, X-732-83-8 (Butler, 1983). On somewhat later flights of the Orbiter, STS-7 and STS-8, the Naval Research Laboratory and the Goddard Space Flight Center jointly developed and flew a GAS payload whose primary objective was to evaluate the performance of ultraviolet-sensitive (Schumann) photographic emulsions in the Orbiter environment, including pre-flight integration, on-orbit exposure to the ambient environment of the Orbiter bay and post-flight conditions before removal of the experiment from the vehicle. These emulsions, used in spectrographs to record solar radiations with wavelengths between 100 A and 2000 A, have low gelatin content and no protective gelatin overcoating in order to maximize their UV sensitivity. Consequently, they are extremely sensitive to environmental conditions. Furthermore, they are exposed directly to space during the observations because any intervening protective window or lense would completely absorb the radiations to be studied. which was prepared at the Naval Research Laboratory under the direction of Robert Kreplin (Kreplin et al., 1984 a) also included two thermal sensors, whose output was recorded once an hour with a precision of 0.7O C. The experiment operated nominally on both missions and provided important data confirming that W - sensitive emulsions could tolerate integration and flight on the Shuttle with relatively little deterioration. The results of these studies have already been reported (Kreplin et al, 1984 b). The temperature measurements also were recorded successfully and are the basis for this paper. They are a useful complement to the thermal observations made on STS-3 and provide additional insight into the reaction of a payload to typical thermal environments that GAS experiments are subject to. Our GAS experiment and the circumstances of its flights were particularly useful in terms of modeling the thermal response of the GAS canister and our instrument. The Orbiter was held (except for interruptions for star tracker alignment, satellite deployments, etc., in specific attitudes for sufficiently long periods of time that the thermal response of the instrument to each attitude was well measured. Two types of GAS canister end cap, one, the insulated end cap and the other a silverized teflon covered end-cap, were used on the two flights so that a direct comparison of the thermal performance of the two types was obtained. This report is an attempt to compare these observations with a simple thermal model of the instrument in the GAS canister in order to assess whether such simple models can be useful to experimenters in predicting the thermal response of their payloads.

Werner M. Neuper↗

Transient vibration and product formation of photoexcited CS 2 measured by time-resolved x-ray scattering

Here, we have observed details of the internal motion and dissociation channels in photoexcited carbon disulfide (CS 2 ) using time-resolved x-ray scattering (TRXS). Photoexcitation of gas-phase CS 2 with a 200 nm laser pulse launches oscillatory bending and stretching motion, leading to dissociation of atomic sulfur in under a picosecond. During the first 300 fs following excitation, we observe significant changes in the vibrational frequency as well as some dissociation of the C–S bond, leading to atomic sulfur in the both 1 D and 3 P states. Beyond 1400 fs, the dissociation is consistent with primarily 3 P atomic sulfur dissociation. This channel-resolved measurement of the dissociation time is based on our analysis of the time-windowed dissociation radial velocity distribution, which is measured using the temporal Fourier transform of the TRXS data aided by a Hough transform that extracts the slopes of linear features in an image. The relative strength of the two dissociation channels reflects both their branching ratio and differences in the spread of their dissociation times. Measuring the time-resolved dissociation radial velocity distribution aids the resolution of discrepancies between models for dissociation proposed by prior photoelectron spectroscopy work.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

EVALUATION OF A LOW FRICTION - HIGH EFFICIENCY ROLLER BEARING ENGINE

This Low Friction (High Efficiency Roller Bearing) Engine (LFE) report presents the work done by The Timken Company to conduct a technology demonstration of the benefits of replacing hydrodynamic bearings with roller bearings in the crankshaft and camshaft assemblies of an internal combustion engine for the purpose of collecting data sufficient to prove merit. The engines in the present study have been more extensively converted to roller bearings than any previous studies (40 needle roller bearings per engine) to gain understanding of the full potential of application of bearing technology. The project plan called for comparative testing of a production vehicle which was already respected for having demonstrated low engine friction levels with a rollerized version of that engine. Testing was to include industry standard tests for friction, emissions and fuel efficiency conducted on instrumented dynamometers. Additional tests for fuel efficiency, cold start resistance and other measures of performance were to be made in the actual vehicle. Comparative measurements of noise, vibration and harshness (NVH), were planned, although any work to mitigate the suspected higher NVH level in the rollerized engine was beyond the scope of this project. Timken selected the Toyota Avalon with a 3.5L V-6 engine as the test vehicle. In an attempt to minimize cost and fabrication time, a ‘made-from’ approach was proposed in which as many parts as possible would be used or modified from production parts to create the rollerized engine. Timken commissioned its test partner, FEV Engine Technology, to do a feasibility study in which they confirmed that using such an approach was possible to meet the required dimensional restrictions and tolerances. In designing the roller bearing systems for the crank and cam trains, Timken utilized as many production engine parts as possible. The crankshafts were produced from production line forgings, which use Timken steel, modified with special machining and heat treatment. Timken designed and manufactured all of the roller bearing related components such as the thrust bearing package. The production connecting rods and camshafts could not be used for the roller bearing engine, so new ones were produced according to the team’s designs using Timken steel. The remaining miscellaneous components were designed and procured by FEV. Timken prepared a display version of the crankshaft portion of the production engine without connecting rods which could be driven by a motor through a cogged-belt and electrically actuated clutch arrangement. A modified version was also made in which the engine was outfitted with roller bearings on the main bearing positions. Preliminary tests showed that the rollerized engine was running with 1/3 less friction than the standard display engine. Additional friction testing and noise characterization was cut short because of shipping damage to the rollerized engine display and because of other project priorities. The team did successfully demonstrate the ability to package roller bearings satisfactorily in numerous locations in a typical automotive engine. The scope of this project did not include durability demonstration and that subject would have to be addressed in any follow-on work. In the actual test phase, the rollerized engine did show significantly less friction in motored dynamometer tests compared to its production equivalent. The 5-10% improvement measured in this study was about half that seen in other studies. However, the fired test results did not show a reduction in friction which did not match prior experience or expectations. Subsequent teardown and inspection of the rollerized engine revealed potential sources of excessive friction in the experimental application. These features would be eliminated in a design not based on modification of production parts. The team is confident (based on experience) that friction reduction would be realized with proper modifications.

02 PETROLEUM↗

Sensing of fluid viscoelasticity from piezoelectric actuation of cantilever flexural vibration

An experimental method is proposed to measure the rheological properties of fluids. The effects of fluids on the vibration actuated by piezoelectric patches were analyzed and used in measuring viscoelastic properties. Fluid-structure interactions induced changes in the beam vibration properties and frequency-dependent variations of the complex wavenumber of the beam structure were used in monitoring these changes. To account for the effects of fluid-structure interaction, fluids were modelled as a simple viscoelastic support at one end of the beam. The measured properties were the fluid’s dynamic shear modulus and loss tangent. Using the proposed method, the rheological properties of various non-Newtonian fluids were measured. The frequency range for which reliable viscoelasticity results could be obtained was 10–400 Hz. Viscosity standard fluids were tested to verify the accuracy of the proposed method, and the results agreed well with the manufacturer’s reported values. The simple proposed laboratory setup for measurements was flexible so that the frequency ranges of data acquisition were adjustable by changing the beam’s mechanical properties.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fine structure of current noise spectra in nanoelectromechanical resonators

Here, we study the frequency-dependent noise of a suspended carbon nanotube quantum dot nanoelectromechanical resonator induced by electron-vibration coupling. Using a rigorous Keldysh diagrammatic technique, we establish a formal framework connecting the vibrational properties to electrical measurements. We find that the noise power spectrum exhibits a narrow resonant peak at the frequency of the vibrational modes. However, this fine structure tends to disappear due to a coherent cancellation effect when the tunneling barriers are tuned to a symmetric point. Notably, measuring the electrical current noise spectra provides a sensitive alternative method for detecting the damping and dephasing of quantum vibrational modes.

Electric measurements↗

Infrared vibration-rotation spectra of the ClO radical using tunable diode laser spectroscopy

Tunable diode laser spectroscopy is used to measure the infrared vibration-rotation spectra of the ClO radical. The radical is generated in a flow system where a Cl2-He mixture passes through a microwave discharge to dissociate the Cl2. An O3-O2 mixture from an ozone generator is injected into the system downstream of the microwave discharge where O3 combines with Cl to form ClO. By adjusting the gas flow rates to yield an excess of Cl atoms, all the ozone is combined. ClO concentration is measured with UV absorption at 2577 and 2772 A and a deuterium lamp as a continuous source. Total cell pressure is 5.5 torr. The diode laser spectrometer is calibrated with ammonia lines as a reference where possible. The frequency of vibration-rotation lines is expressed as a function of rotational quantum number, fundamental vibrational frequency, and the rotational constants of the upper and lower vibrational states.

Rogowski, R. S.↗

Influence of Temperature on Sr{sub 0.35}La{sub 0.40}Ca{sub .25}Fe{sub 11.6}Co{sub 0.4}O{sub 19} Hexagonal Ferrites Against Structural, Morphological and Magnetic Properties Prepared by Conventional Ceramic Reaction Methodology

Conventional Ceramic Reaction Methodology has been utilized for the preparation of M-type hexagonal ferrites of Sr{sub 0.35}La{sub 0.40}Ca{sub 0.25}Fe{sub 11.6}Co{sub 0.4}O{sub 19} magnets. X-ray diffraction has been performed for phase determination of the magnetic powders. At calcination temperatures ranging from 1220 to 1330 {sup ∘}C, the synchronize compost of the magnetic powders comprised of M-type hexagonal ferrites together with a small amount of impurity phase such as α-Fe{sub 2}O{sub 3} were co-existed. At calcination temperature above 1270 {sup ∘}C, single-phase M-type hexaferrites can be obtained. The particles seemed to be in a hexagonal plate-like mould which spread-out homogeneously were examined by field emission scanning electron microscopy. The magnetic edibility of the magnetic powders was intended by permanent magnetic measurement test equipment vibrating sample magnetometer. Magnetic properties, such as specific saturation magnetization, coercivity and remanence were temperature-dependent. However, with the increase of sintering temperature, i.e. above 1270 {sup ∘}C, saturation magnetization was increased while the coercivity showed reversed order.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Domain Texture of the Orthorhombic Phase of La 2-x Ba x CuO 4

Bragg Coherent Diffraction Imaging (BCDI) experiments have been carried out at the Advanced Photon Source using a new cryostat system developed to achieve high mechanical stability and low vibrations. Here, we measured the (012) LTO Bragg peak which is unique to the low-temperature orthorhombic (LTO) phase of micron-sized crystals of the High-temperature Superconductor La 2-x Ba x CuO 4 (LBCO) to study the formation of structural domains. Each time the sample was cooled into the orthorhombic phase, the diffraction pattern of domains was different. Finally, this confirms the interpretation of pinning of the lower-temperature Charge Density Wave domains observed in coherent resonant X-ray speckle correlation analysis experiments.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

One-dimensional NiCuZn ferrite nanostructures: Fabrication, structure, and magnetic properties

Ni{sub 0.5-x}Cu{sub x}Zn{sub 0.5}Fe{sub 2}O{sub 4} (0.0{<=}x{<=}0.5) ferrite nanofibers with diameters of 80-160 nm have been prepared by electrospinning and subsequent heat treatment. Both the average grain size and lattice parameter are found to increase with the addition of copper. Fourier transform infrared spectra indicate that the portion of Fe{sup 3+} ions at the tetrahedral sites move to the octahedral sites as some of the substituted Cu{sup 2+} ions get into the tetrahedral sites. Vibrating sample magnetometer measurements show that the coercivity of these ferrite nanofibers decreases with increasing Cu concentration, whereas the specific saturation magnetization initially increases, reaches a maximum value at x=0.2 and then decreases with the Cu content further increase. Notable differences in magnetic properties at room temperature (298 K) and 77 K for the Ni{sub 0.3}Cu{sub 0.2}Zn{sub 0.5}Fe{sub 2}O{sub 4} nanofibers and corresponding powders are observed and mainly arise from the grain size and morphological variations between these two materials. - Graphical abstract: NiCuZn ferrite nanofibers with diameters of 80-160 nm have been prepared by electrospinning technique and their magnetic behavior is different from that of the corresponding powder sample.

36 MATERIALS SCIENCE↗

Ferromagnetic behavior of copper oxide-nanowire-covered carbon fibre synthesized by thermal oxidation

Copper oxide nanowires were synthesized on carbon fibre surfaces by annealing of copper thin films at 400 deg. C for 4 h in air. The nanowires were characterized with field emission scanning electron microscope (FESEM), transmission electron microscope (TEM) and X-ray diffraction (XRD). The magnetic properties of CuO nanowires were measured with a vibrating sample magnetometer (VSM). Its diameters range covered 40-100 nm and lengths range covered 1-3 {mu}m. It is interesting that the CuO nanowires on the carbon fibres showed ferromagnetism at room temperature.

36 MATERIALS SCIENCE↗

Growth, spectroscopic properties and laser performance of Nd{sup 3+}-doped potassium ytterbium tungstate laser crystal

The 5 at.% Nd{sup 3+}-doped potassium ytterbium tungstate (Nd{sup 3+}:KYb(WO{sub 4}){sub 2}, hereafter Nd:KYbW) laser crystal with the dimension up to 28 mm x 15 mm x 12 mm was grown by the top seeded solution growth (TSSG) method. The infrared spectrum of crystal sample was measured, and the vibrational peaks were assigned. According to the absorption and emission spectra of crystal sample, the absorption and emission cross-sections are 16.03 x 10{sup -20} cm{sup 2} at 808 nm and 10.72 x 10{sup -20} cm{sup 2} at 1067 nm, respectively. The fluorescence life of {sup 4}F{sub 3/2} energy level is 196.33 {mu}s, and the fluorescence branching ratio for the {sup 4}F{sub 3/2}-{sup 4}I{sub 11/2} transition at 1067 nm is 55.74%. The energy transfer between Nd{sup 3+} and Yb{sup 3+} ions was observed from the fluorescence spectra pumped by 808 and 980 nm LD sources and the Stark levels of Yb{sup 3+} in Nd:KYbW crystal were determined. Highly efficient laser output up to 305 mW of Nd:KYbW crystal at 1067 nm has been achieved under pumping by a CW 808 nm laser diode at room temperature. The optical-optical conversion efficiency is 33.9% and the slope efficiency is 46.8%.

36 MATERIALS SCIENCE↗

Magnetic force microscopy study of domain walls in Co{sub 2}Z ferrite

Graphical abstract: - Highlights: • Hexaferrite Co{sub 2}Z is synthesized through the modified Pechini method. • Magnetic domains are observed in anisotropic Co{sub 2}Z single grain using MFM. • Observed single grain domain thickness is in good agreement with Dotsh model. - Abstract: Hexaferrite Co{sub 2}Z was synthesized through the modified Pechini method. Partially oriented samples were obtained after consolidation with uniaxial pressing and calcination/sintering at 1300 °C/1330 °C. The sample composition and morphology was identified with X-ray diffractometry (XRD) and scanning electron microscopy (SEM) with energy-dispersive X-ray spectrometry (EDS). MFM studies of the single grains revealed a domain structure with 0.7 μm wide. The Co{sub 2}Z static magnetization was measured with a vibrating sample magnetometer (VSM), and was used to calculate a single grain domain with a thickness of 4.8 μm. This result is in good agreement with SEM observations of the single grain thickness.

36 MATERIALS SCIENCE↗

Quaternary M{sub 0.25}Cu{sub 0.25}Mg{sub 0.5}Fe{sub 2}O{sub 4} (M = Ni, Zn, Co, Mn) ferrite oxides: Synthesis, characterization and magnetic properties

Highlights: • Superparamagnetic quaternary nanoferrite (M{sub 0.25}Cu{sub 0.25}Mg{sub 0.5}Fe{sub 2}O{sub 4,} where M = Mn, Zn, Co, Ni) were obtained. • C, O, H and metals were observed by XPS analysis. • Phases purity were confirmed by XRD diffraction and crystallite size (3–10 nm) were determind. - Abstract: We report the synthesis of M{sub 0.25}Cu{sub 0.25}Mg{sub 0.5}Fe{sub 2}O{sub 4} (where M = Mn, Zn, Co, Ni) nanoparticles using the coprecipitation method in the presence of carboxymethyl cellulose (CMC) as the in-situ surfactant. The crystalline structure and surface morphology were examined by means of X-ray diffraction (XRD) and scanning electron microscopy (SEM) and it was established that the average diameter of the magnetic nanoparticles (MNPs) is in the range of 3–10 nm. X-ray photoelectron spectroscopy (XPS) and Fourier transform infrared spectroscopy (FTIR) show that the MNPs are activated by the hydrophilic groups of the surfactant, which coat them and enhance their stability. The vibrating sample magnetometry measurements show the superparamagnetic behavior of the nanoparticles. Due to their small crystallite size, which implies large surface area, and their functionalization with organic groups, the obtained nanoparticles could have medical and catalytic applications.

36 MATERIALS SCIENCE↗

Electric-Field Control of the Tautomerization and Metal Ion Binding Reactivity of 8-Hydroxyquinoline Immobilized to an Electrode Surface

Surface-enhanced Raman scattering (SERS) spectra of a metal-complexing ligand, immobilized to a silver electrode surface, exhibits significant structural changes upon application of modest potentials. A detailed spectroscopic investigation shows that the potential applied to the electrode surface governs the tautomerization equilibrium of the immobilized ligand, p-((8-hydroxyquinoline)azo)benzenethiol (SHQ). Potential-dependent SERS spectra reveal that SHQ exists predominantly in a keto–hydrazone tautomeric form at applied potentials that are negative of –300 mV (vs Ag/AgCl), while the enol–azo tautomer is strongly favored at potentials positive of this value. The observed switching of the tautomer population occurs within a narrow range of applied potentials, ~200 mV (Ag/AgCl). Electrical control over the tautomerization equilibrium of immobilized SHQ governs the reactivity of the ligand toward metal ion complexation, where the enol–azo tautomer exhibits much greater affinity for metal ion binding compared to its keto–hydrazone counterpart. Accordingly, the potential applied to the electrode can be used to influence metal ion binding of immobilized SHQ through control over the tautomerization equilibrium, to produce an electrically switchable surface for metal ion complexation. Large differences in the electric dipole moment of the two tautomers, estimated from density functional theory calculations, suggested a model where the potential dependence arises from the interaction of the ligand dipole with electric fields that exist at a polarized electrode surface. Furthermore, this model accurately predicts the relative tautomer populations versus applied potential, at interfacial electric fields that are consistent with previous measurements of the vibrational Stark effect at polarized interfaces. Potential applications of this technology to several areas of analytical chemistry are considered.