Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “VENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 793 records · Page 44

Investigation of space shuttle vehicle 140C configuration orbiter (model 16-0) wheel well pressure loads in the Rockwell International 7.75 x 11 foot wind tunnel (OA143)

Experimental aerodynamic investigations were conducted on a sting mounted .0405-scale representation of the 140C outer mold line space shuttle orbiter configuration in the Rockwell International 7.75 x 11.00 foot low speed wind tunnel. The primary test objectives were to define the orbiter wheel well pressure loading and its effects on landing gear thermal insulation and to investigate the pressure environment experienced by both the horizontal flight nose probe and air vent door probes. Steady state and dynamic pressure values were recorded in the orbiter nose gear well, left main landing gear well, horizontal flight nose probe, and both left and right air vent door probe. All steady state pressure levels were measured by Statham differential pressure transducers while dynamic pressure levels were recorded by Kulite high frequency response pressure sensors.

Mennell, R. C.↗

Developments in low-gravity cryogenic propellant acquisition and thermal control systems

Development programs are described for two low-gravity cryogenic propellant acquisition systems: a full-screen liner system, and a refillable start-tank. First, based on experimental LH2 screen flow data, the fluid-dynamic characteristics of an integrated screen/thermodynamic vent system were analyzed for a design compared to 17.5 cu fg supercritical life-support systems, and for a Tug orbital LH2/LQ2 resupply system. Second, the analysis, design, fabrication, and test of a 10 cu ft, annular-screen start-tank with a wall-mounted thermodynamic vent was performed. The test program demonstrated that the system expelled LH2 against 1-g and performed properly over a range of conditions.

Cady, E. C.↗

Shuttle LOX loading transient study. Task 2 milestone report. National space and technology laboratories (NSTL) LOX loading facility analysis

Transient thermodynamic analyses were made of the LOX loading system proposed for the space shuttle main propulsion test article (MPTA). This system is made up of a LOX replenish system and a main LOX line which include the barge tank, the lines, pumps, and valves between the barge and the orbiter (ORB) ground service equipment (GSE) interface, the MPTA fill system, the space shuttle main engine (SSME) chilldown bleed system, and the GSE vent system. System analyses include predictions of system performance sensitivity to operating sequence and LOX flowrate, temperature, and quality at the ORB/GSE interface. The transient thermodynamic conditions at the SSME feed line entrance, ET entrance (tank bottom), and the SSME bleed/GSE vent TEE are also included. The analyses are based on continuous SSME bleed flow during GSE facility chilldown.

Glasgow, V. L.↗

Heat Pipe Technology: A bibliography with abstracts

This bibliography lists 149 references with abstracts and 47 patents dealing with applications of heat pipe technology. Topics covered include: heat exchangers for heat recovery; electrical and electronic equipment cooling; temperature control of spacecraft; cryosurgery; cryogenic, cooling; nuclear reactor heat transfer; solar collectors; laser mirror cooling; laser vapor cavitites; cooling of permafrost; snow melting; thermal diodes variable conductance; artery gas venting; and venting; and gravity assisted pipes.

Source record↗

Experimental evaluation of outer planets probe thermal insulation concepts

An experimental program was conducted to evaluate various thermal insulation concepts for use in the Outer Planets Probe (OPP) during entry and descent into the atmospheres of Jupiter, Saturn, and Uranus. Phenolic fiberglass honeycomb specimens representative of the OPP structure were packed and tested with various fillers: Thermal conductivity measurements were made over a temperature range of 300 K to 483 K and pressures from vacuum up to 10 atmospheres in helium and nitrogen gas environments. The conductivity results could not be fully explained so new test specimens were designed with improved venting characteristics, and tested to determine the validity of the original data. All of the conductivity data showed results that were substantially higher than expected. The original test data in helium were lower than the data from the redesigned specimens, probably due to inadequate venting of nitrogen gas from the original specimens. The thermal conductivity test results show only a marginal improvement in probe thermal protection performance for a filled honeycomb core compared to an unfilled core. In addition, flatwise tension tests showed a severe bond strength degradation due to the inclusion of either the powder or foam fillers. In view of these results, it is recommended that the baseline OPP design utilize an unfilled core.

Grote, M. G.↗

Heat-transfer test results for a .0275-scale space shuttle external tank with a 10 deg/40 deg double cone-ogive nose in the NASA/AMES 3.5-foot hypersonic wind tunnel (FH14), volume 2

A .0275 scale forebody model of the new baseline configuration of the space shuttle external tank vent cap configuration was tested to determine the flow field due to the double cone configuration. The tests were conducted in a 3.5 foot hypersonic wind tunnel at alpha = -5 deg, -4.59 deg, 0 deg, 5 deg, and 10 deg; beta = 0 deg, -3 deg, -5.51 deg, -6 deg, -9 deg, and +6 deg; nominal freestream Reynolds numbers per foot of 1.5 x 1 million, 3.0 x 1 million, and 5.0 x 1 million; and a nominal Mach number of 5. Separation and reattached flow from thermocouple data, shadowgraphs, and oil flows indicate that separation begins about 80% from the tip of the 10 deg cone, then reattaches on the vent cap and produces fully turbulent flow over most of the model forebody. The hardware disturbs the flow over a much larger area than present TPS application has assumed. A correction to the flow disturbance was experimentally suggested from the results of an additional test run.

Carroll, H. R.↗

Experiments on the properties of superfluid helium in zero gravity

The paper describes a research program designed to study the behavior of superfluid liquid helium in low and zero gravity in order to determine the properties which are critically important to its use as a stored cryogen for cooling scientific instruments aboard spacecraft for periods up to several months. The experiment program consists of a series of flights of an experiment package on a free-fall trajectory both on an aircraft and on a rocket. The objectives are to study thickness of thin films of helium as a function of acceleration, heat transfer in thin films, heat transfer across copper-liquid helium interfaces, fluid dynamics of bulk helium in high and low accelerations and under various conditions of rotations, alternate methods of separation of liquid and vapor phases and of efficient venting of the vapor, and undesirable thermomechanical oscillations in the vent pipes. Preliminary results from aircraft tests are discussed.

Mason, P.↗

Boundary layer analysis of a Centaur standard shroud

An analytical boundary layer investigation was carried out in conjunction with an experimental wind tunnel test to determine the discharge characteristics of the Centaur shroud ascent vent system on the Titan/Centaur launch vehicle. This involved estimating the effect of the local boundary layers on the vent discharge for vehicle Mach numbers ranging from 0.8 to 1.56. The growth of the boundary layer along the vehicle was influenced by the interaction with flanges protruding into the flow and by the longitudinal corrugations in the vehicle surface. The effects of the flange and corrugations were treated by approximate techniques. In addition, boundary layer calculations were made for a 3 percent model of the launch vehicle compared with experimental results.

Hingst, W. R.↗

Reduction of liquid hydrogen boiloff: Optimal reliquefaction system design and cost study

The refrigeration cycles investigated are referred to as Joule-Thomson cycles because they depend on the J-T effect to produce the low temperatures. Two basic competitive refrigeration cycles were evaluated. The first vents a portion of cold H2 gas to achieve the required precooling; the second uses LN2 for precooling. Both open loop and closed loop cycles were evaluated as well as combinations of venting to supplement the LN2 precooling. All cycles use a H2 compressor to achieve the desired high pressure (1325 psig). The heat compression was removed by cooling water. The high pressure H2 gas was cooled in counter flow heat exchangers by flowing cold H2 to the compressor. Further cooling was achieved for cycles using LN2 by passing H2 vapors through a LN2 heat exchanger. Finally, the high pressure H2 gas was expanded through a J-T valve where a portion of H2 was liquefied. The low pressure H2 gas flow back through the heat exchangers to the compressor is that portion not liquefied and makes up hydrogen gas from the dewar.

Source record↗

Filling of orbital fluid management systems

A study was performed with three objectives: (1) analyze fluid management system fill under orbital conditions; (2) determine what experimentation is needed; and (3) develop an experimental program. The fluid management system was a 1.06m (41.7 in) diameter pressure vessel with screen channel device. Analyses were conducted using liquid hydrogen and N2O4. The influence of helium and autogenous pressurization systems was considered. Analyses showed that fluid management system fill will be more difficult with a cryogen than with an earth storable. The key to a successful fill with cryogens is in devising techniques for filling without vent liquid, and removing trapped vapor from the screen device at tank fill completion. This will be accomplished with prechill, fill, and vapor condensation processes. Refill will require a vent and purge process, to dilute the residual helium, prior to introducing liquid. Neither prechill, chill, nor purge processes will be required for earth storables.

Merino, F.↗

Determination of overcharge protection

Nylon separator degradation was examined as a function of temperature. Electrochemically active uncharged excess negative (overcharge protection)was measured by charging a cell venting it until it became fully charged, and continuing to overcharge the vent gas. The gas was analyzed as a function of time. The amount of hydrogen evolved was examined, and the cell voltage was observed as the oxygen and/or hydrogen evolved from the cell.

Scott, W. R.↗

Cryogenic helium 2 systems for space applications

Two cryogenic systems are described which will provide cooling for experiments to be flown on Spacelab 2 in the early 1980's. The first system cools a scanning infrared telescope by the transfer of cold helium gas from a separate superfluid helium storage dewar. The flexible design permits the helium storage dewar and transfer assembly to be designed independent of the infrared experiment. Where possible, modified commerical apparatus is used. The second cryogenic system utilizes a specially designed superfluid dewar in which a superfluid helium experiment chamber is immersed. Each dewar system employs a porous plug as a phase separator to hold the liquid helium within the dewar and provide cold gas to a vent line. To maintain the low vapor pressure of the superfluid, each system requires nearly continuous prelaunch vacuum pump service, and each will vent to space during the Spacelab 2 flight.

Urban, E.↗

Fluctuations in SO2 emission during recent eruptions of Etna

The eruptive activity of July-August 1977 of Mt. Etna consisted of four separate, short eruptive episodes. The rate of SO2 emission during these eruptions was monitored using a remote-sensing correlation spectrometer. The obtained data suggest that fluctuations in the SO2 emission rate provide a means for predicting eruptions of Etna. The July-August 1977 eruptions were confined to the North East Crater vent, while continuous degassing occurred from the central vents. The continuous gas plume was blown downwind immediately after it was emitted while the eruption plumes from the North East Crater rose 500-1,000 m before being blown horizontally. Monitoring began on 24 July, immediately after the first eruptive episode had ended, and continued until 27 August.

Malinconico, L. L., Jr.↗

On the detection of lunar volatile emissions

This letter shows that the Apollo lunar-surface Suprathermal Ion Detection Experiment (SIDE) instruments lack the sensitivity to detect even large emissions of radiogenic gases from the moon if the venting of these gases occurs primarily at a few-well-defined sites of lunar transient phenomena (LTPs). It is suggested that specific flight instruments for the proposed ESA Polar Orbiting Lunar Observatory (POLO) mission, which could detect active venting, would help determine the energy source for LTPs and would increase knowledge of lunar geophysics. A critical-velocity model for the LTP energy source is briefly discussed.

Srnka, L. J.↗

Similar explosive eruptions of lunar and terrestrial volcanoes

A mathematical model of one-dimensional, steady duct flow of a mixture of gas and small solid particles (rock), has been applied to the earth and the moon under geometrically and dynamically similar conditions to simulate explosive eruption conditions. Numerical results for equilibrium two-phase flows for lunar and terrestrial explosive eruptions under similar conditions indicate that: (1) a lunar explosive vent is much larger than the corresponding terrestrial vent, (2) the exit velocity from the lunar explosive flow may be higher than the lunar escape velocity, but the exit velocity of terrestrial explosive flow is much less than that of the lunar case (this result supports the hypothesis that Australian tektites came from the moon as a stream of a mixture of rock and gas of extremely high speed), and (3) the thermal effects on the lunar explosive flows are much larger than those of the terrestrial case.

Pai, S. I.↗

Energy budget of the volcano Stromboli, Italy

The results of the analyses of movies of eruptions at Stromboli, Italy, and other available data are used to discuss the question of its energy partitioning among various energy transport mechanisms. Energy is transported to the surface from active volcanoes in at least eight modes, viz. conduction (and convection) of the heat through the surface, radiative heat transfer from the vent, acoustical radiation in blast and jet noise, seismic radiation, thermal energy of ejected particles, kinetic energy of ejected particles, thermal energy of ejected gas, and kinetic energy of ejected gas. Estimated values of energy flux from Stromboli by these eight mechanisms are tabulated. The energy budget of Stromboli in its normal mode of activity appears to be dominated by heat conduction (and convection) through the ground surface. Heat carried by eruption gases is the most important of the other energy transfer modes. Radiated heat from the open vent and heat carried by ejected lava particles also contribute to the total flux, while seismic energy accounts for about 0.5% of the total. All other modes are trivial by comparison.

Mcgetchin, T. R.↗

Preliminary geological mapping of Io

A preliminary summary of information gained by Voyager 1 on the colored, terrain and landform surface units of Io and their global distribution is presented. Colored units are classified as white to bluish-white regions which may be sulfur or sulfur dioxide deposits, red, orange, or yellow regions thought to contain various sublimates or alterations of sulfur, brownish regions limited to the polar areas and dark brown areas surrounding some vents. Terrain features observed include plains broken by scarps, isolated mountainous regions and volcanic vents resembling terrestrial caldera or pit craters. Maps of the distribution of these features, compiled by photogeological mapping techniques developed for terrestrial volcanic mapping, are presented, and the implications of the surface unit distributions for the volcanology, crustal composition, internal convection patterns and surface age of Io are discussed.

Masursky, H.↗

Lunar mare domes - Classification and modes of origin

In this paper, lunar mare domes (LMDs) are classified according to morphologic and morphometric (primarily diameter) characteristics, and consideration is given to their origin and role in lunar surface processes. In general, they occur either as low, flat, circular structures with convex shapes, slopes less than about 5 deg, and display summit craters, or as irregular structures often adjacent to highland regions and rarely containing summit craters. It is found that LMDs originate through extrusion of lavas through vents to produce low lava shields, or through flooding and draping of preexisting topography to produce kipukas and irregular domes. Smooth, vent-related mare domes range from about 3-17 km in diameter and up to several hundred meters in elevation; they are similar in morphology to small terrestrial lava shields.

Head, J. W.↗