Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “TIME MEASUREMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 793 records · Page 44

SU-D-BRA-01: Feasibility Study for Swallowing Prediction Using Pressure Sensors

Purpose: To develop a swallowing prediction system (SPS) using force sensing sensors and evaluate its feasibility. Methods: The SPS developed consists of force sensing sensor units, a thermoplastic mask, a signal transport device and a control PC installed with an in-house software. The SPS is designed to predict the pharyngeal stage of swallowing because it is known that internal organ movement occurs in pharyngeal stage. To detect prediction signal in the SPS, the force sensing sensor units were attached on both the submental muscle region and thyroid cartilage region of the thermoplastic mask. While the signal from the thyroid cartilage region informs the action of swallowing, the signal from the submental muscle region is utilized as a precursor for swallowing. Since the duration of swallowing is relatively short, using such precursor (or warning) signals for machine control is considered more beneficial. A volunteer study was conducted to evaluate the feasibility of the system. In this volunteer study, we intended to verify that the system could predict the pharyngeal stage of the swallowing. We measured time gaps between obtaining the warning signals in the SPS and starting points of the pharyngeal stage of swallowing. Results: The measured data was examined whether the time gaps were in reasonable order to be easily utilized. The mean and standard deviation values of these time gaps were 0.550 s ± 0.183 s. in 8 volunteers. Conclusion: The proposed method was able to predict the on-set of swallowing of human subjects inside the thermoplastic mask, which has never been possible with other monitoring systems such as camera-based monitoring system. With the prediction ability of swallowing incorporated into the machine control mechanism (in the future), beam delivery can be controlled to skip swallowing periods and significant dosimetric gain is expected in head & neck cancer treatments. This work was supported by the Radiation Technology R&D program (No. 2015M2A2A7038291) and by the Mid-career Researcher Program (2014R1A2A1A10050270) through the National Research Foundation of Korea funded by the Ministry of Science, ICT&Future Planning.

60 APPLIED LIFE SCIENCES↗

THE ODTX SYSTEM FOR THERMAL IGNITION AND THERMAL SAFETY STUDY OF ENERGETIC MATERIALS

Understanding the response of energetic material to thermal event is very important for the storage and handling of energetic materials. The One Dimensional Time to Explosion (ODTX) system at the Lawrence Livermore National Laboratory (LLNL) can precisely measure times to explosion and minimum ignition temperatures of energetic materials at elevated temperatures. These measurements provide insight into the relative ease of thermal ignition and allow for the determination of kinetic parameters. The ODTX system can potentialy be a good tool to measure violence of the thermal ignition by monitoring the size of anvil cavity. Recent ODTX experimental data on various energetic materials (solid and liquids) are reported in this paper.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Depth-Penetrating Temperature Measurements of Thermal Barrier Coatings Incorporating Thermographic Phosphors

Thermographic phosphors have been previously demonstrated to provide effective non-contact, emissivity-independent surface temperature measurements. Because of the translucent nature of thermal barrier coatings (TBCs), thermographic phosphor-based temperature measurements can be extended beyond the surface to provide depth-selective temperature measurements by incorporating the thermographic phosphor layer at the depth where the temperature measurement is desired. In this paper, thermographic phosphor (Y2O3:Eu) fluorescence decay time measurements are demonstrated to provide through-the-coating thickness temperature readings up to 1100 C with the phosphor layer residing beneath a 100 micron thick TBC (plasma-sprayed 8wt% yttria-stabilized zirconia). With an appropriately chosen excitation wavelength and detection configuration, it is shown that sufficient phosphor emission is generated to provide effective temperature measurements, despite the attenuation of both the excitation and emission intensities by the overlying TBC. This depth-penetrating temperature measurement capability should prove particularly useful for TBC diagnostics where a large thermal gradient is typically present across the TBC thickness. The fluorescence decay from the Y2O3:Eu layer exhibited both an initial short-term exponential rise and a longer-term exponential decay. The rise time constant was demonstrated to provide better temperature indication below 500 C while the decay time constant was a better indicator at higher temperatures.

Eldridge, Jeffrey I.↗

The CLAS12 Backward Angle Neutron Detector (BAND)

The Backward Angle Neutron Detector (BAND) of CLAS12 detects neutrons emitted at backward angles of 155° to 175°, with momenta between 200 and 600 MeV$/c_0$. It is positioned 3-m upstream of the target, consists of 18 rows and 5 layers of 7.2-cm by 7.2-cm scintillator bars, and read out on both ends by PMTs to measure time and energy deposition in the scintillator layers. Between the target and BAND there is a 2-cm thick lead wall followed by a 2-cm veto layer to suppress gammas and reject charged particles. This paper discusses the component-selection tests and the detector assembly. Timing calibrations (including offsets and time-walk) were performed using a novel pulsed-laser calibration system, resulting in time resolutions better than 250 ps (150 ps) for energy depositions above 2 MeV (5 MeV). Cosmic rays and a variety of radioactive sources were used to calibration the energy response of the detector. Scintillator bar attenuation lengths were measured. We report the time resolution results in a neutron momentum reconstruction resolution, $δp/p$ < 1.5% for neutron momentum 200 ≤ $p$ ≤ 600 MeV/c. Final performance of the BAND with CLAS12 is shown, including electron–neutral particle timing spectra and a discussion of the off-time neutral contamination as a function of energy deposition threshold.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

EVALUATING CONCENTRATION PROFILES DURING UNSTEADY MIXING

Pulse jet mixing tests to suspend noncohesive solids in Newtonian liquid were conducted at three geometric scales. To understand the solids suspension process an ultrasonic concentration probe was used to measure the concentration of solids in the cloud during a pulse at various elevations and radial positions. The data are being analyzed to provide a model for predicting concentration as a function of elevation. This paper presents a simple single frequency ultrasonic measurement application that demonstrates the ability of ultrasonic sensors to measure slurry concentration based on signal attenuation. Sensor calibration data show that ultrasonic signal attenuation is proportional to the applied frequency and to the slurry volume fraction. Real-time measurements of ultrasonic signal attenuation were used to track the process of slurry mixing using single sensors and sensor arrays. Comparison of means of the ultrasonic measurements with means obtained from discrete extractive measurements show that the distributions overlap and cannot be statistically distinguished. The real-time ultrasonic sensor can be used as a primary measurement method or to reduce reliance upon extractive methods to measure slurry density.

42 ENGINEERING↗

Time-of-flight measurements of metastable state lifetimes.

A time-of-flight method for measurement of the lifetime of metastable molecules is described. The method is applicable to a molecular beam that has molecules in several different metastable excited states. As compared to methods used previously, the method has the advantages that it does not require selective excitation or quenching of the different states; moreover, it does not require a determination of the relative populations or velocity distributions of molecules in the excited states.

Kaslow, D. E.↗

In-line measurements of below-the-surface food deformation during drying with an interference-based optical fiber strain sensor

Real-time measurements of food deformation are important for quality control in drying, yet they pose significant challenges. In this study, we developed an interference-based optical fiber strain sensor to enable in-line, continuous, below-the-surface strain measurements in drying of soft food samples. Compared to a strain resolution of 8 × 10 -4 at zero strain and 7.2 × 10 -3 at 0.20 strain reported in our previously published work, the present study achieves markedly improved resolutions of 1.3 × 10 -4 at zero strain and 7.8 × 10 -4 at 0.25 strain, which strains are the lower and higher boundaries of the dynamic range, respectively. This nearly order-of-magnitude improvement is attributed to the unique interference-based sensing mechanism, no need for calibration to convert optical signals to strain, and the system-design-enabled immunity to fiber-disk misalignments and light source intensity fluctuations. To demonstrate the in-line process monitoring, deformation measurements of fresh banana slices and sugar cookie doughs were carried out in a benchtop oven and an industrial-scale hot-air pilot dryer, respectively. In both dryers, strain measurements were continuously measured during the whole drying process at various depths and radii below the sample surfaces, with the strains up to 25%. Computer vision was used only in the benchtop drying to confirm the faithfulness of the fiber sensor measurements and cannot provide below-the-surface measurements. The measured spatiotemporal deformation allowed us to confirm the shell-hardening effect and to determine the speed and location of large deformation changes in the whole drying process, the latter of which is related to the sample cracking. To the best of the authors’ knowledge, this study is the first to report on an interferometry-based fiber sensor to measure food deformation. This sensor and the sensing mechanism have high potential for real-time process monitoring and control to prevent over-drying or cracking during drying processes.

47 OTHER INSTRUMENTATION↗

Core-to-valence spectroscopic detection of the CH{sub 2}Br radical and element-specific femtosecond photodissociation dynamics of CH{sub 2}IBr

Element-specific single photon photodissociation dynamics of CH{sub 2}IBr and core-to-valence absorption spectroscopy of CH{sub 2}Br radicals are investigated using femtosecond high-harmonic extreme ultraviolet (XUV) transient absorption spectroscopy. Photodissociation of CH{sub 2}IBr along both the C–I or C–Br reaction coordinates is observed in real-time following excitation at 266 nm. At this wavelength, C–I dissociation is the dominant reaction channel and C–Br dissociation is observed as a minor pathway. Both photodissociation pathways are probed simultaneously through individual 4d(I) N{sub 4/5} and 3d(Br) M{sub 4/5} core-to-valence transitions. The 3d(Br) M{sub 4/5} pre-edge absorption spectrum of the CH{sub 2}Br radical photoproduct corresponding to the C–I dissociation channel is characterized for the first time. Although the radical's singly occupied molecular orbital (SOMO) is mostly localized on the central carbon atom, the 3d(Br) → π{sup *}(SOMO) resonances at 68.5 eV and 69.5 eV are detected 2 eV below the parent molecule 3d(Br) → σ{sup *}(LUMO) transitions. Core-to-valence XUV absorption spectroscopy provides a unique probe of the local electronic structure of the radical species in reference to the Br reporter atom. The measured times for C–I dissociation leading to I and I{sup *} atomic products are 48 ± 12 fs and 44 ± 4 fs, respectively, while the measured C–Br dissociation time leading to atomic Br is 114 ± 17 fs. The investigation performed here demonstrates the capability of femtosecond time-resolved core-level spectroscopy utilizing multiple reporter atoms simultaneously.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Prototype Systems for Measuring Outdoor Air Intake Rates in Rooftop Air Handlers

The widespread absence of systems for real-time measurement and feedback control, of minimum outdoor air intake rates in HVAC systems contributes to the poor control of ventilation rates in commercial buildings. Ventilation rates affect building energy consumption and influence occupant health. The project designed fabricated and tested four prototypes of systems for measuring rates of outdoor air intake into roof top air handlers. All prototypes met the ±20% accuracy target at low wind speeds, with all prototypes accurate within approximately ±10% after application of calibration equations. One prototype met the accuracy target without a calibration. With two of four prototype measurement systems, there was no evidence that wind speed or direction affected accuracy; however, winds speeds were generally below usually 3.5 m s -1 (12.6 km h -1 ) and further testing is desirable. The airflow resistance of the prototypes was generally less than 35 Pa at maximum RTU air flow rates. A pressure drop of this magnitude will increase fan energy consumption by approximately 4%. The project did not have resources necessary to estimate costs of mass produced systems. The retail cost of components and materials used to construct prototypes ranged from approximately $1,200 to $1,700. The test data indicate that the basic designs developed in this project, particularly the designs of two of the prototypes, have considerable merit. Further design refinement, testing, and cost analysis would be necessary to fully assess commercial potential. The designs and test results will be communicated to the HVAC manufacturing community.

42 ENGINEERING↗

Urey: to measure the absolute age of Mars

UREY, a proposed NASA Mars Scout mission will, for the first time, measure the absolute age of an identified igneous rock formation on Mars. By extension to relatively older and younger rock formations dated by remote sensing, these results will enable a new and better understanding of Martian geologic history.

Mars chronology geology↗

Nuclear waste calorimeter for very large drums with 385 litres sample volume

Calorimetry is a very precise and well adapted tool for the classification of drums containing nuclear waste material depending on their level of activities (low, medium, high). A new calorimeter has been developed by SETARAM Instrumentation and the CEA Valduc in France. This new calorimeter is designed for drums having a volume bigger than 100 liters. It guarantees high operator safety by optimizing drum handling and air circulation for cooling, and optimized software for direct measurement of the quantity of nuclear material. The LVC1380 calorimeter makes it possible to work over the range 10 to 3000 mW, which corresponds to approximately 0.03 to 10 g of tritium or 3 to 955 g of {sup 241}Pu in a volume up to 385 liters. This calorimeter is based on the heat flow measurement using Peltier elements which surround the drum in the 3 dimensions and therefore measure all the heat coming from the radioactive stuff whatever its position inside the drum. Calorimeter's insulating layers constitute a thermal barrier designed to filter disturbances until they represent less than 0.001 Celsius degrees and to eliminate long term disturbances associated, for example, with laboratory temperature variations between day and night. A calibration device based on Joule effect has also been designed. Measurement time has been optimized but remains long compared with other methods of measurement such as gamma spectrometry but its main asset is to have a good accuracy for low level activities.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Noncontacting device to indicate deflection of turbopump internal rotating parts

Phase 2 (development) which was concluded for the ultrasonic Doppler device and the light-pipe-reflectance device is reported. An ultrasonic Doppler breadboard system was assembled which accurately measured runout in the J-2 LOX pump impeller during operation. The transducer was mounted on the outside of the pump volute using a C-clamp. Vibration was measured by conducting the ultrasonic wave through the volute housing and through the fluid in the volute to the impeller surface. The impeller vibration was also measured accurately using the light-pipe probe mounted in an elastomeric-gland fitting in the pump case. A special epoxy resin developed for cryogenic applications was forced into the end of the fiber-optic probe to retain the fibers. Subsequently, the probe suffered no damage after simultaneous exposure to 2150 psi and 77 F. Preliminary flash X-radiographs were taken of the turbine wheel and the shaft-bearing-seal assembly, using a 2-megavolt X-ray unit. Reasonable resolution and contrast was obtained. A fast-neutron detector was fabricated and sensitivity was measured. The results demonstrated that the technique is feasible for integrated-time measurements requiring, perhaps, 240 revolutions to obtain sufficient exposure at 35,000 rpm. The experimental verification plans are included.

Hamilton, D. B.↗

An intercalibration of Meteosat-1 and GOES-2 visible and infrared measurements

An intercomparison between radiative parameters determined from visible and infrared channels of the Meteosat-1 and GOES-2 geosynchronous satellites has been carried out using data obtained over the central Atlantic Ocean for 5 November 1978. Hourly visible-infrared measurement pairs at a nominal resolution of 5 km (Meteosat) or 8 km (GOES) have been stored in 1 deg x 1 deg longitude-latitude regions. For the infrared intercomparisons, the GOES 11.5 micron radiance has been compared to Meteosat infrared counts. The scatter in partly cloudy regions is interpreted as being caused by meteorological differences arising from differences in measurement time between the two data sets. For the visible intercomparison, the GOES measurements for clear and cloudy scenes have first been converted with the aid of scene-dependent angular reflectance and albedo models to estimates of the filtered shortwave radiance that GOES would have measured had it been in the Meteosat position. This value has then been compared to Meteosat counts for the shortwave channel. The results indicate that earlier Meteosat calibrations made from airplane overflights of a limited variety of surfaces are applicable to much larger areas of cloud and ocean.

Brooks, D. R.↗

Fiber Optical Solar Simulator

A new solar simulator is described whose output closely matches a desired solar spectrum for testing photovoltaic cells. The accurate simulation of the spectrum is attained by combining three light beams, each tailored to have suitable spectral content. The three light beams, derived from two sources, are filtered and 'mixed' by means of a trifurcated, randomized fiber cable so that when superimposed they add up to the desired solar spectrum. The fiber optic solar simulator (FOSS) simplifies solar cell testing by greatly reducing measurement time, obviating need for spectral mismatch corrections, and improving the accuracy of measurement. Other applications of FOSS are also described.

Sopori, Bhushan L.↗

Methods of Constructing a Blended Performance Function Suitable for Formation Flight

Two methods for constructing performance functions for formation fight-for-drag-reduction suitable for use with an extreme-seeking control system are presented. The first method approximates an a prior measured or estimated drag-reduction performance function by combining real-time measurements of readily available parameters. The parameters are combined with weightings determined from a minimum squares optimization to form a blended performance function.

control systems↗