Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “THERMAL STRESSES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 793 records · Page 44

Chemical composition based machine learning model to predict defect formation in additive manufacturing

With a goal of exploiting additive manufacturing to improve the manufacturing of existing reactor materials, we developed a chemical composition-based machine learning model to predict the printability of any given alloy in laser powder bed fusion (L-PBF) using experimental data from peer-reviewed literature. We defined printability as the ability to avoid defects like cracking, balling, porosity, and lack of fusion, that are caused by thermal stresses (during solidification or liquation), molten pool disintegration into disconnected small beads or lack of heat input respectively. Our models predict the tendency of balling defect formation and porosity percentage for a given composition, under a given set of processing conditions. To predict the likelihood of balling defect, three models: a random forest classifier, a gradient boost regressor and a neural network were trained on a dataset containing both traditional alloys and high entropy alloys. The neural network model showed the highest accuracy of 92.3 % in predicting the balling defect formation. A random forest regressor, gradient boost regressor and neural network were trained and tested on a dataset of various alloys to predict porosity. The random forest regressor showed the best predictions with an R 2 score of 0.97. The models also revealed the relative importance of the input descriptors on defect-formation tendency. Of particular significance was the identification of carbon as an important element in determining the occurrence of balling and percent porosity in alloys like steel, as well as being moderately important to the percentage porosity in other alloys as well as steel. Manganese was also identified as a key descriptor for the percentage of porosity in steel and other alloys. Manganese’s low thermal conductivity and consistent presence in the dataset is the likely cause for its contribution. Carbon’s role is attributable to its relatively high specific heat and high melting temperature. In conclusion, our model serves as a swift, chemistry-based tool to design experiments and find modified compositions better suited for additive manufacturing.

36 MATERIALS SCIENCE↗

Envelope-driven comfort risk in residential demand response

Residential demand response (DR) is a valuable resource for grid reliability, but remains challenging because the highly heterogeneous residential building stock leads to widely varying and hard-to-predict load and comfort responses during DR events. Although prior research has estimated the technical potential of DR-capable technologies for achieving energy demand savings, little is known about how they affect thermal comfort. In particular, it remains unclear how indoor thermal conditions due to DR depend on the thermal envelope characteristics of the housing stock. To address this gap, this study provides a systematic, location-specific assessment of indoor thermal performance during DR-events across the US housing stock using both typical DR weather data and detailed building metadata. We evaluate how envelope characteristics influence indoor temperatures during realistic simulated summer and winter DR events across 37 US locations, applying both temperature threshold and rate of temperature change criteria to estimate region-level probabilities of discomfort. Additionally, we show the impact of distinct weather patterns that intensify or abate thermal stress on comfort outcomes. Results show a near-universal overheating risk in summer DR events, where comfort outcomes are strongly influenced by rapid risk of comfort violations. In contrast, overall winter DR discomfort risk is lower, risk escalation is more gradual and shows greater sensitivity to event duration. These findings offer a data-driven quantification of comfort risk across diverse climates and building envelopes, demonstrating the need for region-specific DR scheduling and discomfort mitigation strategies tailored to local weather patterns and the performance of existing residential buildings.

Demand response↗

Operational Characteristics of Two Commercially Available Personal Cooling Vests

Personal thermoregulatory systems which provide chest cooling are used in the industrial and aerospace environments to alleviate thermal stress. However, little information is available regarding the physiologic and circulatory changes produced by routine operation of these systems. The objectives of this study were to compare the effectiveness of two passive cooling vests, and to measure the body temperature and circulatory changes produced by each cooling vest configuration. A Life Enhancement Technologies, (LET) ice vest garment and a Steele, Inc. vest were used to cool the chest region of 11 male subjects (25 to 55 yr) in this study. Calf, forearm and finger blood flows were measured using a tetrapolar impedance rheograph. The subjects, seated in an upright position at normal room temperature (approximately 21 C) were tested for 60 min. with the cooling system operating at its maximum cooling capacity. Blood flows were recorded continuously using a computer data acquisition system with a sampling frequency of 250 Hz. Oral, right and left ear temperatures and cooling system parameters were logged manually every 5 min. Arm, leg, chest and rectal temperatures; heart rate; respiration; and an activity index were recorded continuously on a U.F.I., Inc. Biolog ambulatory monitor. No significant differences were found in either the oral or ear temperature responses to the two vests. However, the rectal and mean skin temperatures at the end of the cooling period were both significantly lower (P less than 0.05), approximately 0.2 and 1.9 C, respectively for the LET vest than for the Steele garment. These data show that different vest configurations may produce different thermal responses in healthy male subjects which should be considered in the use of these cooling garments.

Ku, Yu-Tsuan E.↗

Technology Solutions Case Study: Cladding Attachment Over Thick Exterior Insulating Sheathing

The addition of insulation to the exterior of buildings is an effective means of increasing the thermal resistance of wood-framed walls and mass masonry wall assemblies. Insulation on the exterior of the structure has many direct benefits, including better effective R-value from reduced thermal bridging, better condensation resistance, reduced thermal stress on the structure, as well as other commonly associated improvements such as increased airtightness and improved water management. Although the approach has proven effective, there is resistance to its widespread implementation due to a lack of research and understanding of the mechanisms involved in the development of the vertical displacement resistance capacity. In addition, the long-term in-service performance of the system has been questioned due to potential creep effects of the assembly under the sustained dead load of the cladding and effects of varying environmental conditions. In addition, the current International Building Code (IBC) and International Residential Code (IRC) do not have a provision that specifically allows this assembly. In this project, researchers from Building Science Corporation, a Building America team, investigated these issues to better understand the mechanics behind this method of cladding attachment

BSC↗

Secondary Fragmentation of Comet Shoemaker-Levy 9 and the Ramifications for the Progenitor's Breakup in July 1992

Comprehensive analysis of discrete events of secondary fragmentation leads to a conceptually new understanding of the process of disintegration of comet Shoemaker-Levy 9. We submit that the jovian tidal forces inflicted extensive cracks throughout the interior of the original nucleus but did not split it apart. The initial disruption was apparently accomplished by stresses exerted on the cracked object by its fast rotation during the early post-perijove period of time. We argue that this disruption was in fact a rapid sequence of episodes during July 1992 that gave birth to the 12 on-train, or primary, fragments: A, C, D, E, G, H, K, L, Q (later Q(sub 1)), R, S, and W. The discrete events of secondary fragmentation, which gave birth to the off-train fragments, are understood in this scenario as stochastic manifestations of the continuing process of progressive disintegration. Of the 13 off-train fragments considered, nine were secondary--B, F, G(sub 2), M, N, P (later P(sub 2) or P(sub 2a)), Q(sub 2), U, and V--and four tertiary (J, P(sub 1), P(sub 2b), and T). The separation parameters of 11 off-train fragments were determined. The vectorial distribution of separation velocities of these fragments shows a strong concentration toward a great circle, unquestionably an effect of the approximately conserved angular momentum of the progenitor comet since the time of its initial disruption. Also apparent is their clumping (except for P(sub 1)) to a segment along the great circle, implying that the fragments were consistently released from one side of their parents, thus explaining for the first time why the off-train fragments preferentially appeared on one side of the nuclear train. In order to obtain a consistent solution, our model requires that the points of separation be on the antisolar side of the parent fragments, where thermal stresses are likely to enhance the effect of rotation. The episodes of secondary fragmentation are found to have nine months after the close encounter with Jupiter in early July 1992, and the separation velocities ranged between 0.36 and 1.7 m/s. The spin-axis position is determined to have been nearly in the jovicentric orbit plane, which rules out the Asphaug-Benz-Solem strengthless aggregate model as a plausible breakup hypothesis. Since the separation velocities are rotational in nature, they cannot substantially exceed the critical limit for centrifugal breakup and offer an estimate for the original nuclear dimensions. The comet's nucleus is found to have been approximately 10 km in diameter and spinning rapidly. With the exception of P(sub 1) and apparently also P(sub 2) and F, no nongravitational deceleration was detected in the motions of the off-train fragments. Serious doubts are cast on continuing appreciable activity of any of these fragments. Indeed, when it was necessary to introduce a deceleration into the equations of motion, the effect appears to have been due to the action of solar radiation pressure on the centroid of centimeter-sized particulates in the disintegrating condensations.

Sekanina, Z.↗

Physiologic and Functional Responses of MS Patients to Body Cooling Using Commercially Available Cooling Garments

Personal cooling systems are widely used in industrial and aerospace environments to alleviate thermal stress. Increasingly they are also used by heat sensitive multiple sclerosis (HSMS) patients to relieve symptoms and improve quality of life. There are a variety of cooling systems commercially available to the MS community. However, little information is available regarding the comparative physiological changes produced by routine operation of these various systems. The objective of this study was to document and compare the patient response to two passive cooling vests and one active cooling garment. The Life Enhancement Technology, Inc. (LET) lightweight active cooling vest with cap, the MicroClimate Systems (MCS) Change of Phase garment, and the Steele Vest were each used to cool 13 male and 13 female MS subjects (31 to 67 yr.) in this study. The subjects, seated in an upright position at normal room temperature (approximately 22 C), were tested with one of the cooling garments. Oral, fight and left ear temperatures were logged manually every 5 min. An-n, leg, chest and rectal temperatures; heart rate; and respiration were recorded continuously on a U.F.I., Inc. Biolog ambulatory monitor. Each subject was given a series of subjective and objective evaluation tests before and after cooling. The LET and Steele vests test groups had similar, significant (P less than 0.01) cooling effects on oral and ear canal temperature, which decreased approximately 0.4 C, and 0.3 C, respectively. Core temperature increased (N.S.) with all three vests during cooling. The LET vest produced the coldest (P less than 0.01) skin temperature. Overall, the LET vest provided the most improvement on subjective and objective performance measures. These results show that the garment configurations tested do not elicit a similar thermal response in all MS patients. Cooling with the LET active garment configuration resulted in the lowest body temperatures for the MS subjects; cooling with the MCS vest was least effective. For functional responses, the LET test group performed better than the other two vests.

Ku, Yu-Tsuan E.↗

Experimental system for studying temperature gradient-driven fracture of oxide nuclear fuel out of reactor

Temperature gradients in ceramic light water reactor (LWR) uranium dioxide (UO 2 ) nuclear fuel pellets generate thermal stresses that cause fractures in the fuel beginning early in the life of fresh fuel. The combination of heating due to fission and forced convective cooling on the exterior of LWR fuel rods generates a temperature profile that is difficult to replicate outside the reactor environment. In the present study, a state-of-the-art experimental set-up using electrical heating to replicate fission heating was built and surrogate fuel materials such as ceria (CeO 2 ) were used to validate the system. Cracking experiments were conducted on these surrogates by inducing reactivity-initiated-accident (RIA) like temperature gradients in the pellets via induction and direct resistance heating. Induction heating was done using copper coils and molybdenum susceptors which heated the surrogates to a threshold temperature that is sufficiently high for the fuel material to conduct current. Thereafter, direct resistance heating was used by a D.C. power supply to introduce volumetric heating to replicate LWR operating conditions analogous to fission heating. The pellets were held against nickel electrodes and mounted on a boron nitride test-stand. All the tests were carried out in a stainless-steel vacuum chamber. Simultaneous real-time dual imaging of the surrogate pellet surface has been implemented using an optical and infrared camera system which will be mounted along axial and perpendicular directions to the pellet surface respectively. A beam-splitter was used to split the incoming radiation from the sample into two halves. While one of the beams is transmitted from the splitter through a bandpass filter to obtain optical images, the other beam is reflected from the splitter to the thermal camera to capture full field temperature gradients of the as fabricated pellet surface during crack initiation and propagation. In the current series of tests, a 2-color pyrometer was used for recording and comparing the surface and centerline temperatures of the surrogate pellets in lieu of the thermal camera. A LabVIEW data acquisition system has been set up for collecting useful data during experiments.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Physiologic Responses Produced by Active and Passive Personal Cooling Vests

Personal thermoregulatory systems which provide chest cooling are used in the industrial and aerospace environments to alleviate thermal stress. However, little information is available regarding the physiologic and circulatory changes produced by routine operation of these systems. The objectives of this study were to document and compare the subjects' response to three cooling vests in their recommended configurations. The Life Enhancement Tech (LET) lightweight active cooling vest with cap, the MicroClimate Systems Change of Phase garment (MCS), and the Steele Vest were each used to cool the chest regions of 12 male and 8 female Healthy subjects (21 to 69 yr.) in this study. The subjects, seated in an upright position at normal room temperature (approx. 22 C), were tested for 60 min. with one of the cooling garments. The LET active garment had an initial coolant fluid inlet temperature of 60 F, and was ramped down to 50 F. Oral, right and left ear canal temperatures were logged manually every 5 min. Arm, leg, chest and rectal temperatures; heart rate; and respiration were recorded continuously on a U.F.I., Inc. Biolog ambulatory monitor. For men, all three vests had similar, significant cooling effects. Decreases in the average rectal temperature, oral temperature, and ear canal temperatures were approximately 0.2 C, 0.2 C and 0.1 C, respectively. In contrast to the men, the female subjects wearing the MCS and Steel vests had similar cooling responses in which the core temperature remained elevated and oral and ear canal temperatures did not drop. The LET active garment cooled most of the female subjects in this study; rectal, oral and ear temperature decreased about 0.2 C, 0.3 C and 0.3 C, respectively. These results show that the garment configurations tested do not elicit a similar thermal response in all subjects. A gender difference is evident. The LET active garment configuration was most effective in decreasing temperatures of the female subjects; the MCS vest was least effective. For male subjects, the three vests appear to be more nearly equivalent. The active garment system under study included a cooling cap, which may account for some of the difference in response.

Ku, Yu-Tsuan E.↗

Cladding Attachment Over Thick Exterior Insulating Sheathing (Fact Sheet)

The addition of insulation to the exterior of buildings is an effective means of increasing the thermal resistance of wood-framed walls and mass masonry wall assemblies. The location of the insulation on the exterior of the structure has many direct benefits, including better effective R-value from reduced thermal bridging, better condensation resistance, reduced thermal stress on the structure, as well as other commonly associated improvements such as increased airtightness and improved water management. For thick layers of exterior insulation (more than 1.5 in.), the use of wood furring strips attached through the insulation back to the structure has been used by many contractors and designers as a means to provide a convenient cladding attachment location. Although the approach has proven effective, there is significant resistance to its widespread implementation due to a lack of research and understanding of the mechanisms involved in the development of the vertical displacement resistance capacity. In addition, the long-term in-service performance of the system has been questioned due to potential creep effects of the assembly under the sustained dead load of the cladding and effects of varying environmental conditions. In addition, the current International Building Code (IBC) and International Residential Code (IRC) do not have a provision that specifically allows this assembly.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Operational Characteristics of Four Commercially Available Personal Cooling Vests

Personal thermoregulatory systems which provide chest cooling are used in the industrial and aerospace environments to alleviate thermal stress. However, little information is available regarding the physiologic and circulatory changes produced by routine operation of these systems. The objectives of this study were to compare the effectiveness of two passive and two active cooling vests, and to measure the body temperature and circulatory changes produced by each cooling vest configuration. The MicroClimate Systems and the Life Enhancement Tech(LET) lightweight liquid cooling vests, the Steele Vest and LET's Zipper Front Garment were used to cool the chest region of 11 male and 10 female subjects (25 to 55 yr.) in this study. Calf, forearm and finger blood flows were measured using a tetrapolar impedance rheograph. The subjects, seated in an upright position at normal room temperature (approx.21 C), were tested for 60 min. with the cooling system operated at its maximum cooling capacity. Blood flows were recorded continuously using a computer data acquisition system with a sampling frequency of 250 Hz. Oral, right and left ear temperatures and cooling system parameters were logged manually every 5 min. Arm, leg, chest and rectal temperatures; heart rate; respiration; and an activity index were recorded continuously on a URI Inc. Biolog ambulatory monitor. In general, the male and female subjects' rectal and ear temperature responses to cooling were similar for all vest configurations tested. Oral temperatures during the recovery period were significantly (P<0.05) lower than during the control period, approx.0.2 - 0.5 C, for both men and women wearing any of the four different garments. The corresponding car temperatures were significantly (P<0.05) decreased approx.0.2 - 0.3 C by the end of the recovery period. Compared to the control period, no significant differences were found in rectal temperatures during cooling and recovery periods. These results show that all vest configurations elicit a similar thermal response in both male and female subject groups. However, subject population variance was rather large and may have masked differences between the vests. One vest may prove more effective than another for a given individual, and experience is the only means of determining this.

Ku, Yu-Tsuan E.↗

Temperature Rise on Liner Surfaces of Fuel Cell Electric Vehicle Tanks during Fueling Process

Herein, the temperature of the inner tank walls, or plastic liners, of composite pressure tanks in fuel cell electric vehicles during fueling using three‐dimensional computational fluid dynamics (CFD) models is evaluated. The liner materials are limited to 85.0 °C to prevent thermal stress causing material failure that would result in a hydrogen leak. Therefore, the temperature of hydrogen gas must be limited to below 85.0 °C during the fueling process as dictated by the current fueling protocol. However, there are limited experimental or simulation data confirming that the temperature changes do not exceed the threshold. Herein, the liner temperatures with CFD tank models for two sizes of type IV tanks representative of the upper and lower system bounds that are close to the SAE J2601 fueling protocol (36.0 and 244.0 L) are evaluated. First, each model's reliability is validated with experimental data and then analyzed, and the data are used to evaluate the maximum hydrogen and liner temperatures under real‐world fueling conditions. The evaluation shows that the maximum liner surface temperature of each tank model is at least 7 °C lower than that of the hydrogen. Additionally, there is at least 12 °C difference found between the upper limit and actual liner temperatures.

33 ADVANCED PROPULSION SYSTEMS↗

System-Level Heat Transfer Analysis, Thermal- Mechanical Cyclic Stress Analysis, and Environmental Fatigue Modeling of a Two-Loop Pressurized Water Reactor. A Preliminary Study

This report provides an update on an assessment of environmentally assisted fatigue for light water reactor components under extended service conditions. This report is a deliverable in April 2015 under the work package for environmentally assisted fatigue under DOE's Light Water Reactor Sustainability program. In this report, updates are discussed related to a system level preliminary finite element model of a two-loop pressurized water reactor (PWR). Based on this model, system-level heat transfer analysis and subsequent thermal-mechanical stress analysis were performed for typical design-basis thermal-mechanical fatigue cycles. The in-air fatigue lives of components, such as the hot and cold legs, were estimated on the basis of stress analysis results, ASME in-air fatigue life estimation criteria, and fatigue design curves. Furthermore, environmental correction factors and associated PWR environment fatigue lives for the hot and cold legs were estimated by using estimated stress and strain histories and the approach described in NUREG-6909. The discussed models and results are very preliminary. Further advancement of the discussed model is required for more accurate life prediction of reactor components. This report only presents the work related to finite element modelling activities. However, in between multiple tensile and fatigue tests were conducted. The related experimental results will be presented in the year-end report.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Hybrid Solar System (Final Scientific/Technical Report)

GTI Energy (GTI) teamed with the University of California at Merced (UCM) to scaleup the hybrid solar system (HSS) technology for demonstrating its performance at the US Gypsum (USG) plant in Plaster City, California. The technology integrates two-stage concentrating solar collector with matching particle thermal transport and storage (TSS) system to deliver cost-effective, and on-demand distributed high temperature industrial process heat up to 600°C with solar thermal, in this case to a gypsum kettle, to reduce its fuel use and carbon footprint. Current solar technologies, which reach these temperatures, are not distributable (towers) or cost-effective (dish). The research team developed a conceptual system design for host site retrofit, including preliminary heat balance, process flow diagram, particle to process heat exchanger and equipment placements at the site. Subsequently, parallel efforts were carried out at UCM to design, build and test a 12 m long commercial scale prototype concentrating thermal-only collector system and at GTI to design, build and test a matching 650°C capable particle TTS system. The nominal 50 kWth collector consists of a parabolic trough and three 4 m long two-stage receivers in series. Prior to on-sun testing, a 4 m long receiver was fabricated and successfully tested at 650 °C in a laboratory setting for 100 hrs of continuous operation showing less than 15% radiation loss. A 7 m wide x 17 m long parabolic trough was then installed at UCM for on-sun testing of the 12 m long receiver, and concurrently several 4 m long receivers were built. The optics of the parabolic trough were calibrated, and on-sun test were carried out on 12 m long receivers. During tests, the intense solar radiation (53x) caused the absorber tubes in the receivers to bend, reducing the overall optical efficiency. To address the bending issue, a self-consistent algorithm that includes ray tracing, thermal and deformation models was developed to perform thermal stress analysis on absorbers for parabolic solar collectors. Results obtained with this algorithm showed a dramatic rise in deformation as absorber tube length increases. A combined efficiency parameter that includes the occluded area for the mounts was developed to obtain an optimized tube length obtained. Based on the results, a length of 2.7 m for the absorber + 0.2 m for the coupler was chosen to minimize any bending and optimize optical efficiency while maintaining ease of mounting. The associated particle TTS system was designed, built and successfully tested at GTI. It includes storage, receiving and lock hoppers and piping that simulates the transfer of captured solar energy to an actual industrial furnace. Tests over 77 charge-discharge cycles demonstrated <2% particle degradation, with no problematic particle accumulations and no flow interruptions. The piping pressure drop was about 5 psi. The team also worked with Stanley Consultants (Stanley) to prepare conceptual and preliminary engineering packages to facilitate follow-on development and commercialization efforts. These include process and instrumentation diagram’s (P&ID’s), general arrangements, electrical one-line, project definitions document, equipment data sheets, schedule, and construction cost estimate for 2 MWth system. Updated HSS technology commercialization and customer engagement plans and detailed costs and evaluated market trade-offs and manufacturing.

03 NATURAL GAS↗

MHz free electron laser x-ray diffraction and modeling of pulsed laser heated diamond anvil cell

A new diamond anvil cell experimental approach has been implemented at the European x-ray Free Electron Laser, combining pulsed laser heating with MHz x-ray diffraction. In this report we use this setup to determine liquidus temperatures under extreme conditions, based on the determination of time-resolved crystallization. The focus is on a Fe-Si-O ternary system, relevant for planetary cores. This time-resolved diagnostic is complemented by a finite-element model, reproducing temporal temperature profiles measured experimentally using streaked optical pyrometry. This model calculates the temperature and strain fields by including (i) pressure and temperature dependencies of material properties, and (ii) the heat-induced thermal stress, including feedback effect on material parameter variations. Making our model more realistic, these improvements are critical as they give 7000 K temperature differences compared to previous models. Laser intensities are determined by seeking minimal deviation between measured and modeled temperatures. Combining models and streak optical pyrometry data extends temperature determination below detection limit. The presented approach can be used to infer the liquidus temperature by the appearance of SiO 2 diffraction spots. In addition, temperatures obtained by the model agree with crystallization temperatures reported for Fe–Si alloys. Our model reproduces the planetary relevant experimental conditions, providing temperature, pressure, and volume conditions. Those predictions are then used to determine liquidus temperatures at experimental timescales where chemical migration is limited. This synergy of novel time-resolved experiments and finite-element modeling pushes further the interpretation capabilities in diamond anvil cell experiments.

36 MATERIALS SCIENCE↗

Effects of Initial Powder Size on the Mechanical Properties and Microstructure of As-Extruded GRCop-84

GRCop-84 was developed to meet the mechanical and thermal property requirements for advanced regeneratively cooled rocket engine main combustion chamber liners. It is a ternary Cu- Cr-Nb alloy having approximately 8 at% Cr and 4 at% Nb. The chromium and niobium constituents combine to form 14 vol% Cr2Nb, the strengthening phase. The alloy is made by producing GRCop-84 powder through gas atomization and consolidating the powder using extrusion, hot isostatic pressing (HIP) or vacuum plasma spraying (VPS). GRCop-84 has been selected by Rocketdyne, Ratt & Wlutney and Aerojet for use in their next generation of rocket engines. GRCop-84 demonstrates favorable mechanical and thermal properties at elevated temperatures. Compared to NARloy-Z, the currently used inaterial in the Space Shuttle, GRCop-84 has approximately twice the yield strength, 10-1000 times the creep life, and 1.5-2.5 times the low cycle fatigue life. The thermal expansion of GRCop-84 is 7515% less than NARloy-Z which minimizes thermally induced stresses. The thermal conductivity of the two alloys is comparable at low temperature but NARloy-Z has a 20-50 W/mK thermal conductivity advantage at typical rocket engine hot wall temperatures. GRCop-84 is also much more microstructurally stable than NARloy-Z which translates into better long term stability of mechanical properties. Previous research into metal alloys fabricated by means of powder metallurgy (PM), has demonstrated that initial powder size can affect the microstructural development and mechanical properties of such materials. Grain size, strength, ductility, size of second phases, etc., have all been shown to vary with starting powder size in PM-alloys. This work focuses on characterizing the effect of varying starting powder size on the microstructural evolution and mechanical properties of as- extruded GRCop-84. Tensile tests and constant load creep tests were performed on extrusions of four powder meshes: +140 mesh (great3er than l05 micron powder size), -140 mesh (less than or equal to 105 microns), -140 plus or minus 270 (53 - 105 microns), and - 270 mesh (less than or equal to 53 microns). Samples were tested in tension at room temperature and at 500 C (932 F). Creep tests were performed under vacuum at 500 C using a stress of 111 MPa (16.1 ksi). The fracture surfaces of selected samples from both tests were studied using a Scanning Electron Microscope (SEM). The as-extruded materials were also studied, using both optical microscopy and SEM analysis, to characterize changes within the microstructure.

Okoro, Chika L.↗

Si Complies with GaN to Overcome Thermal Mismatches for the Heteroepitaxy of Thick GaN on Si

Heteroepitaxial growth of lattice mismatched materials has advanced through the epitaxy of thin coherently strained layers, the strain sharing in virtual and nanoscale substrates, and the growth of thick films with intermediate strain‐relaxed buffer layers. However, the thermal mismatch is not completely resolved in highly mismatched systems such as in GaN‐on‐Si. Here, geometrical effects and surface faceting to dilate thermal stresses at the surface of selectively grown epitaxial GaN layers on Si are exploited. The growth of thick (19 µm), crack‐free, and pure GaN layers on Si with the lowest threading dislocation density of 1.1 × 10 7 cm −2 achieved to date in GaN‐on‐Si is demonstrated. With these advances, the first vertical GaN metal–insulator–semiconductor field‐effect transistors on Si substrates with low leakage currents and high on/off ratios paving the way for a cost‐effective high power device paradigm on an Si CMOS platform are demonstrated

Tanaka, Atsunori↗

Interface Reconstruction from Ruddlesden–Popper Structures Impacts Stability in Lead Halide Perovskite Solar Cells

The impact of the bulky-cation-modified interfaces on halide perovskite solar cell stability is underexplored. Here, in this work, the thermal instability of the bulky-cation interface layers used in the state-of-the-art solar cells is demonstrated. X-ray photoelectron spectroscopy and synchrotron-based grazing-incidence X-ray scattering measurements reveal significant changes in the chemical composition and structure at the surface of these films that occur under thermal stress. The changes impact charge-carrier dynamics and device operation, as shown in transient photoluminescence, excitation correlation spectroscopy, and solar cells. The type of cation used for surface treatment affects the extent of these changes, where long carbon chains provide more stable interfaces. These results highlight that prolonged annealing of the treated interfaces is critical to enable reliable reporting of performances and to drive the selection of different bulky cations.

36 MATERIALS SCIENCE↗

Solution Processed Ternary Tin (II) Alloy as Hole–Transport Layer of Sn–Pb Perovskite Solar Cells for Enhanced Efficiency and Stability

Tin-lead (Sn-Pb) narrow bandgap (NBG) perovskites show great potential in both single-junction and all-perovskite tandem solar cells. Sn-Pb perovskite solar cells (PSCs) are still limited by low charge collection efficiency and poor stability. Here, we report a ternary Sn (II) alloy of SnOCl as the hole-transport material (HTM) with a work function of 4.95 eV for Sn-Pb PSCs. The solution processed SnOCl layer has a texture structure which not only reduces the optical loss of the devices but also changes grain growth of Sn-Pb perovskites and boosts the carrier diffusion length to 3.63 μm. The formation of small perovskite grains at the HTM/perovskite interface is suppressed. These result in an almost constant internal quantum efficiency of 96 ± 2% across the absorption spectrum of Sn-Pb perovskites. The SnOCl HTM significantly enhances the stability of Sn-Pb PSCs with 87% of its initial efficiency retained after 1-sun illumination for 1,200 h, and keep 85% efficiency under 85°C thermal stress for 1,500 h. Furthermore, the hybrid HTM further improve the stabilized efficiencies of single-function Sn-Pb PSCs and all-perovskite tandem solar cells to 23.2% and 25.9%, respectively. This discovery opens an avenue to the multi-component metal alloys as HTM in PSCs.

36 MATERIALS SCIENCE↗