Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “THERMAL HYDRAULICS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 793 records · Page 44

Modeling nuclear waste disposal in crystalline rocks at the Forsmark and Olkiluoto repository sites – Evaluation of potential thermal–mechanical damage to repository excavations

We conduct coupled thermo-hydro-mechanical modeling of a KBS-3V repository design in crystalline rocks, using data and conditions from the Forsmark in Olkiluoto repository sites in Sweden and Finland. The study focuses on repository performance related to the impact of thermal and hydraulic evolution on the potential for thermal–mechanical damage to underground repository excavations. For the designs and conditions considered at the Forsmark and Olkiluoto repository sites, the simulations show a peak temperature well under the adopted performance target of a 100°C maximum temperature, whereas there is still a high potential for thermal–mechanical damage to the KBS-3V waste deposition holes. The thermal–mechanical damage is much more likely if rock permeability is so low that it delays saturation and swelling of bentonite-clay-based backfill beyond the time for the thermal–mechanical peak, which occurs 50 to 100 years after nuclear waste deposition. We also found that sidewalls of the KBS-3V emplacement tunnels are vulnerable to tensile fracturing due to the combined effect of thermal stressing and backfill swelling. The study highlights a strong interaction between bentonite-based backfill and host rock through capillary suction along with induced rock desaturation. A careful design and selection of the bentonite-clay-based backfill materials for KBS-3V tunnels and deposition holes can facilitate a timely saturation and backfill swelling that in turn can minimize thermal–mechanical damage.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Influence of spatial variability of hydraulic characteristics of soils on surface parameters obtained from remote sensing data in infrared and microwaves

The correct interpretation of thermal and hydraulic soil parameters infrared from remotely sensed data (thermal infrared, microwaves) implies a good understanding of the causes of their temporal and spatial variability. Given this necessity, the sensitivity of the surface variables (temperature, moisture) to the spatial variability of hydraulic soil properties is tested with a numerical model of heat and mass transfer between bare soil and atmosphere. The spatial variability of hydraulic soil properties is taken into account in terms of the scaling factor. For a given soil, the knowledge of its frequency distribution allows a stochastic use of the model. The results are treated statistically, and the part of the variability of soil surface parameters due to that of soil hydraulic properties is evaluated quantitatively.

Brunet, Y.↗

Development of an ERT‐Based Framework for Bentonite Buffers Monitoring From Laboratory Tests: 2. Quantitative Moisture Dynamics Estimation Model

Abstract The long‐term containment of high‐level radioactive waste in geological disposal repositories relies on Engineered Barrier Systems (EBS), with bentonite clay emerging as a candidate material due to its unique properties. Understanding moisture dynamics within bentonite buffers is crucial for EBS performance, as it directly influences the material's swelling capacity, thermal and hydraulic conductivity, mechanical properties, and long‐term evolution under complex thermal‐hydrological‐mechanical (THM) processes. This study develops an advanced Electrical Resistivity Tomography (ERT)‐based framework to quantitatively monitor moisture dynamics under THM conditions. Our framework extends the Waxman‐Smits model to incorporate the coupled effects of temperature, water content, fluid chemistry, and mechanical changes on bentonite's electrical properties. Utilizing HotBENT‐Lab data from our companion paper, which includes electrical conductivity, CT density, and thermocouple measurements, this study offers a novel methodological framework bridging different scales of the model. Our results show that the extended model can estimate water content from ERT data, capturing spatial and temporal variations in moisture distribution within bentonite columns. However, the model tends to overestimate water content compared to CT density‐derived measurements. We address this discrepancy by incorporating a simplified swelling effect model, which improves agreement between ERT and CT density‐based water content estimates. We also discuss model limitations, including simplified treatment of swelling and micropore effects, and propose a conceptual framework for transitioning from laboratory to field applications, addressing challenges such as parameter scalability, field validation methods, and integration of diverse data sources. This ERT‐based framework can potentially advance real‐world moisture monitoring of bentonite‐based EBS in nuclear waste repositories. Plain Language Summary Safely containing high‐level radioactive waste depends on barriers made from materials like bentonite clay, which is effective because it swells and seals in the waste. To ensure these barriers work well over time, it's important to understand how moisture moves through the clay. Our study developed a new method using ERT to monitor moisture levels in bentonite under conditions that mimic those in actual storage sites, including changes in temperature, water content, and mechanical stress. This study improved an existing model to better account for how these factors affect the clay, allowing us to create more accurate moisture maps. Initially, the proposed model overestimated the amount of water in the clay, but its accuracy was improved by factoring in how the clay swells when wet. This study also identified some limitations of the model and suggested ways to adapt it for use in real‐world waste storage sites. This new approach could lead to better monitoring and safety checks for nuclear waste storage systems, helping to ensure long‐term containment. Key Points This work develops an ERT‐based framework extending the Waxman‐Smits model to monitor bentonite moisture dynamics during coupled THM processes The extended model accurately estimates water content from Electrical Resistivity Tomography data, incorporating swelling effects to improve precision This work proposes a conceptual framework for transitioning from laboratory to field applications, advancing EBS monitoring in nuclear waste repositories

Chen, Hang↗

Heat Transfer Experiments of a 1st Stage Blade Cascade for Supercritical CO2 Oxy-Combustion Turbine Application

The results of internally cooled 1st stage blade (S1B) cascade testing in a supercritical CO2 environment is presented. The turbine blade design has been previously established for the end application of an oxy-combustion turbine operating in the Allam-Fetvedt cycle with turbine inlet conditions of 305 bar and 1150°C. The internally cooled blade features leading edge (LE) region impingement cooling, mid-section ribbed serpentine passages, and a pin-finned trailing edge (TE) region before cooling ejection holes. The geometry for the tested blade cascade has a cooled central blade with un-cooled blades on either side to match flowpath areas of the actual turbine. The flowpath reuses internal components previously employed for mid-section region ribbed serpentine passage experiments that established Nusselt number enhancement ratios over a range of Reynolds numbers from 100,000-400,000. New components include flow conditioning plates upstream and downstream of the blade cascade to adequately represent the flow field and blade external heat transfer coefficient profiles for the actual turbine. The cooled central blade utilizes uniform crystal temperature sensors (UCTS) with six sensors each on the blade pressure and suction surfaces distributed radially and from LE to TE. The post-processed UCTS quantified the maximum wall temperature seen at each installed sensor location. The test procedure consisted of establishing supercritical CO2 cooling flow temperature and flow rate and maintaining it throughout the test. The flow rate aims to match that for the actual in-service turbine blade design and is maintained through an orifice restriction to keep the pressure differential between internal cooling flow and external hot flow nearly constant. For the sCO2 flow path external to the blade, temperatures were ramped throughout the test via control of the test loop’s natural gas burner heater. The maximum temperature seen was 468°C and held constant for a duration of 10 minutes at which the blade metal temperature was predicted to be at its maximum before ramping down. For the turbine blade design for service inlet conditions, external flow path computational fluid dynamics (CFD) results and an internal cooling 1-D thermal and hydraulic flow network model using experimentally validated correlations served as thermal finite element (FE) boundary conditions to predict blade metal temperatures. These predicted temperatures were subsequently utilized in a structural FE model to predict blade life ratings dictated by Haynes 282 creep strength data, having a strong dependence on temperature. The boundary conditions experienced during testing are used in the same workflow and compared to the experimental results, with the goal of validating the analysis methodology and providing insight on the uncertainty in local metal temperature predictions.

20 FOSSIL-FUELED POWER PLANTS↗

Estimation of bare soil evaporation using multifrequency airborne SAR

It is shown that for homogeneous areas soil moisture can be derived from synthetic aperture radar (SAR) measurements, so that the use of microwave remote sensing can given realistic estimates of energy fluxes if coupled to a simple two-layer model repesenting the soil. The model simulates volumetric water content (Wg) using classical meterological data, provided that some of the soil thermal and hydraulic properties are known. Only four parameters are necessary: mean water content, thermal conductivity and diffusitivity, and soil resistance to evaporation. They may be derived if a minimal number of measured values of Wg and surface layer temperature (Tg) are available together with independent measurements of energy flux to compare with the estimated values. The estimated evaporation is shown to be realistic and in good agreement with drying stage theory in which the transfer of water in the soil is in vapor form.

Soares, Joao V.↗

Niowave Neutron Source Converter: Lead-Bismuth-Eutectic (LBE) Windowless Target Design and Evaluation

Los Alamos National Laboratory (LANL) is working with Niowave on the design and evaluation of their lead-bismuth-eutectic (LBE) windowless target (i.e., neutron source converter). Niowave plans to use 200 kW electron beam at 40 MeV beam energy to produce neutrons by photonuclear reaction with LBE. Then, the neutrons undergo fission at the surrounding uranium target assembly (UTA) to produce Molybdenum 99 (Mo-99) as a fission product, which eventually decays to Technetium-99 (Tc-99m). Tc-99m is one of important radioisotopes that is used for medical diagnostics. LANL conducted 3D multiphysics analysis for the Niowave neutron converter design and provided design assessment in thermohydraulic aspects. LANL conducted radiation transport calculations using Monte-Carlo N-Particle (MCNP) code with unstructured meshing scheme. The 3D volumetric heating profiles in the LBE and Stainless-Steel (SS) housing were imported into multiphase computational fluid dynamics (CFD) to obtain 3D temperature profiles of LBE and SS through conjugate heat transfer (CHT) analysis. The key findings are: LBE film thickness at the center of the beam is approximately 1.6 cm with a maximum LBE velocity of approximately 1.8 m/s, which is below a 2 m/s limit to avoid erosion issues on supporting structures; Heat deposition in the LBE peaks at ~1 cm depth from the LBE free-surface because of the forward interactions of electron, photon, and neutron with LBE; LBE maximum temperature is ~360 °C, which is below LBE evaporation initiative temperature, ~450 °C; LBE-SS interface temperature is ~350 °C, which is below the safety thermal limit to prevent severe corrosion on SS. The results indicate that Niowave’s neutron converter design satisfies both hydraulic and thermal criteria for safe operation. By virtue of such computational analysis, Niowave can move toward establishing an experimental setup to experimentally test their LBE neutron converter. The following sections describe the detailed work done by LANL.

43 PARTICLE ACCELERATORS↗

Prediction of Thermal Protection System Material Permeability and Hydraulic Tortuosity Factor Using Direct Simulation Monte Carlo

Carbon preforms used in Thermal Protection System (TPS) materials are 80 to 90% porous, allowing for boundary layer and pyrolysis gases to flow through the porous regions. The bulk material properties such as permeability and hydraulic tortuosity factor affect the transport of the boundary layer gases. The use of Direct Simulation Monte Carlo along with the Klinkenberg permeability formulation allows us to compute the continuum permeability and Knudsen correction factor for flow in the transition regime. In this work, we have computed the permeability for two types of carbon preforms, namely, Morgan Felt and FiberForm, and assessed the effect of orientation on the permeability. Since both the materials are anisotropic, the permeability was found to depend on orientation, wherein, the materials are more permeable in the in-plane orientation than the through-thickness orientation. The through-thickness orientation was also more tortuous compared to the in-plane material orientation. Compared to Morgan Felt, FiberForm is less permeable, in both, through thickness and in-plane directions.

Jambunathan, Revathi↗

Safe Affordable Fission Engine-(SAFE-) 100a Heat Exchanger Thermal and Structural Analysis

A potential fission power system for in-space missions is a heat pipe-cooled reactor coupled to a Brayton cycle. In this system, a heat exchanger (HX) transfers the heat of the reactor core to the Brayton gas. The Safe Affordable Fission Engine- (SAFE-) 100a is a test program designed to thermally and hydraulically simulate a 95 Btu/s prototypic heat pipe-cooled reactor using electrical resistance heaters on the ground. This Technical Memorandum documents the thermal and structural assessment of the HX used in the SAFE-100a program.

Steeve, B. E.↗

Thermal Stimulation and Injectivity Testing at Raft River, ID EGS Site

The Raft River geothermal field is the site of an innovative Department of Energy Enhanced Geothermal System (EGS) project to determine the viability of using combined thermal and hydraulic stimulation techniques to improve energy production. Well RRG-9 is currently undergoing a stimulation program using injectate from the US Geothermal Raft River Power Plant and cold water from a cooling tower make-up water well. The stimulation began on 13 June 2013 with injection from the power plant at a temperature of about 39 °C and a pressure of 275 psig. Next, two positive displacement plunger type pumps were used to increase the injection pressure and flow rate for about one month. The highest rate achieved was 258 gpm at a pressure of 741 psig. During this time, fluid from the cooler water well was injected for about 2 weeks at various pressures. Then, the pumps were removed and plant injection resumed on 25 September. Plant injection will continue until the spring of 2014, when a high pressure hydraulic stimulation will be conducted. A series of seismic monitoring stations deployed around the well are providing data on seismic events occurring at the site. Over the past year, 51 microseismic events have been recorded, all less than Magnitude 1. During injection, several diagnostic tests were conducted to gain a better understanding of the well and reservoir. A step-rate test was performed on 22 August to measure the in-situ stress and aid in modeling in-situ fractures. A tracer was injected into the well on 9 September. No tracer was detected in adjacent production wells after several months. A second borehole televiewer survey was conducted for comparison to pre-stimulation images. Here, a third borehole televiewer survey is planned after the high pressure stimulation. Injection test data is evaluated in real time. A modified Hall plot analysis indicates the effective permeability is increasing. The injectivity index supports the results of the modified Hall plot analysis. As the thermal stimulation has continued, the injectivity index has consistently followed an upward trend from 0.1 gpm/psi to 0.53 gpm/psi.

enhanced geothermal systems↗

TEDS Test Plan for Performance Characterization of Packed-bed Thermal Energy Storage Unit

This report proposes a set of test plans for performance measurement and characterization of the packed-bed thermal energy storage (TES) unit for TEDS. The main goals of this test plan are three-fold: (i) support the high-fidelity data measurement for TEDS, (ii) characterize thermal and structural performance of the TEDS TES unit, and (iii) produce high quality validation-oriented data. To achieve the goals, it is first suggested to revisit the instrument calibration and data sampling protocols applied during the startup and commissioning tests of TEDS, based on the observation from the recent CFD validation study using the TEDS TES operational data. The uncertainty quantification of the thermal and hydraulic measurements is also suggested. Lastly, test matrices are provided for charge, discharge, and standby modes of the packed-bed TES unit, respectively, to characterize the thermal and structural performances during the envisioned TEDS operations.

25 ENERGY STORAGE↗

Temperature Oscillations in Loop Heat Pipes - A Revisit

Three types of temperature oscillation have been observed in the loop heat pipes. The first type is an ultra-high frequency temperature oscillation with a period on the order of seconds or less. This type of temperature oscillation is of little significance in spacecraft thermal control because the amplitude is in the noise level. The second type is a high frequency, low amplitude temperature oscillation with a period on the order of seconds to minutes and an amplitude on the order of one Kelvin. It is caused by the back-and-forth movement of the vapor front near the inlet or outlet of the condenser. The third type is a low frequency, high amplitude oscillation with a period on the order of hours and an amplitude on the order of tens of Kelvin. It is caused by the modulation of the net heat load into the evaporator by the attached large thermal mass which absorbs and releases energy alternately. Several papers on LHP temperature oscillation have been published. This paper presents a further study on the underlying physical processes during the LHP temperature oscillation, with an emphasis on the third type of temperature oscillation. Specifically, equations governing the thermal and hydraulic behaviors of LHP operation will be used to describe interactions among LHP components, heat source, and heat sink. The following sequence of events and their interrelationship will also be explored: 1) maxima and minima of reservoir and thermal mass temperatures; 2) the range of the vapor front movement inside the condenser; 3) rates of change of the reservoir and thermal mass temperatures; 4) the rate of heat absorption and heat release by the thermal mass and the rate of vapor front movement; and 5) inflection points of the reservoir and thermal mass temperatures.

Fluid Mechanics and Thermodynamics↗

Advancing 1D thermo-hydraulic tools for large cryogenic facilities

The Cryogenic Division at Fermilab develops large-scale cryogenic systems for particle accelerators and superconducting test facilities. To support design and diagnostics, a Python-based code was created to calculate pressure drops in components such as valves and pipes. This paper presents recent enhancements to the code, including new heat transfer functions that improve the accuracy of thermal and hydraulic predictions. The first application models pressure and temperature changes in PIP-II relief pipes, aiding pipe sizing and protecting relief valves. The second example analyzes heat load evolution in a pipe carrying sub-atmospheric helium, helping interpret temperature sensor data and understand gas return behavior to cold compressors. These improvements significantly expand the tool’s capabilities, offering a practical resource for designing and troubleshooting cryogenic systems under dynamic thermal and flow conditions.

Beckwith, Rosalyn [Fermilab]↗

Advancing 1D thermo-hydraulic tools for large cryogenic facilities

The Cryogenic Division at Fermilab develops large-scale cryogenic systems for particle accelerators and superconducting magnet test facilities. To support design and diagnostics, a Python-based code was created to calculate pressure drops in components such as valves and pipes. This paper presents recent enhancements to the code, including new heat transfer functions that improve the accuracy of thermal and hydraulic predictions. The first application models pressure and temperature changes in Proton Improvement Plant PIP-II relief pipes, aiding pipe sizing and protecting relief valves. The second example analyses heat load evolution in a pipe carrying sub-atmospheric helium, helping interpret temperature sensor data and understand gas return behavior to cold compressors. These improvements significantly expand the tool's capabilities, offering a practical resource for designing and troubleshooting cryogenic systems under dynamic thermal and flow conditions.

Beckwith, R. [Fermilab]↗

Coupled Thermo–Hydro–Mechanical Modeling of Hydro-Shearing Stimulation in an Enhanced Geothermal System in the Raft River Geothermal Field, USA

The Raft River Enhanced Geothermal System (EGS) demonstration project aims to improve the geothermal production by enhancing the reservoir permeability via shear stimulation in well RRG-9. In this paper, we performed a series of 3D thermo– hydro–mechanical (THM) simulations to investigate the influence of hydraulic and thermal effects on the development of this EGS. The model includes synthetic fracture populations based on borehole televiewer images and in-situ stress measurements from well RRG-9. Fracture permeability evolution is determined using an empirical permeability law developed from laboratory experiments. The model was calibrated by comparing the hydraulic response to field observations, including wellhead pressure, injection rate, and well injectivity. Particularly, we analyzed the enhancement of reservoir permeability and the spatial extent of the stimulation zone for the given injection schedule. Our results indicate that the permeability enhancement of fractured geothermal reservoir is caused by the combined effects of injection-induced cooling and fluid pressure increase. The decrease of temperature plays a dominant role in reactivation of natural fractures under the hydro-shearing mechanism, while the higher injection pressure promotes shear failure and enlarges the stimulation zone. Finally, for the specified extensional stress state, the model favors greatest permeability enhancement along the maximum horizontal principal stress, a moderate vertical enhancement, and a smaller gain along the minimum horizontal principal stress.

58 GEOSCIENCES↗

Performance of Flight Compatible Microlith® Catalytic Oxidizer for Exploration Trace Contaminant Control

Precision Combustion, Inc. (PCI) and NASA Marshall Space Flight Center have been developing, characterizing, and optimizing prototype high temperature catalytic oxidizers based on PCI’s patented Microlith® technology and long-term endurance test data to meet the requirements of future spaceflight exploration missions. Based on the demonstrated performance (20,000+ hours) of a subscale prototype, a next-generation prototype was designed to meet exploration contaminant load control demands while upgrading the prototype form and fit to match flight-compatible interfaces. Prototype design considerations intended to minimize power consumption, impacting process thermal and hydraulic performance, are discussed herein. We also report on performance characteristics of the catalytic oxidizer and future efforts for component packaging and light-weighting.

Trace Contaminants↗

A high-performance lung-inspired ceramic 3D-printed heat exchanger for high-temperature energy-efficient systems

The thermal-to-electric conversion efficiency of next-generation supercritical carbon dioxide and concentrated solar power plants is significantly augmented by operating at temperatures exceeding 1000 °C if durable, compact, high-temperature heat exchangers (HXs) are developed. Whereas metal 3D-printed HXs fail to operate under extreme temperature conditions, ceramic 3D-printed HXs are deemed promising candidates for high-temperature, highly oxidizing environments. Ceramic 3D-printed HXs, however, exhibit a high gas permeability issue through hot and cold separating walls due to an excessive non-volatile photopolymer content utilized. Here, in this work, a novel leak-free lung-inspired ceramic 3D-printed HX employing a highly complex heat transfer topology is introduced for high-temperature energy-efficient systems. The high permeability issue of ceramic 3D-printed HXs is fully eliminated through a uniform zinc-based coating. It was determined that the effective thermal conductivity of the sintered ceramic heat exchangers is affected by the coated layer. The high-temperature thermal and hydraulic characteristics of the lung-inspired ceramic 3D-printed HX are comprehensively examined and compared against a millichannel 3D-printed HX module. Experimental results indicated that the lung-inspired 3D-printed ceramic HX significantly outperforms its millichannel counterpart. The lung-inspired HX shows a volume-based power density of 8.2 MW/m3 at a hot-side inlet air temperature of 700°C, a 71 % improvement compared with that of the millichannel HX. More importantly, the higher thermal duty of the lung-inspired 3D-printed HX is realized at a lower normalized pressure drop penalty of 510 Pa/W, 22 % lower than that of the millichannel ceramic HX. This study accelerates the advancement of high-performance ceramic 3D-printed HXs with complex topologies for high-temperature energy-efficient systems and/or corrosive environments.

42 ENGINEERING↗