Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Signal processing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 793 records · Page 44

Computers in Aerospace Conference, Los Angeles, Calif., October 31-November 2, 1977, Collection of Technical Papers and Addendum

Papers are presented on such topics as nuclear survivability concepts for airborne computers, military aerospace computer trends, a management approach to acquiring computer systems, software acquisition and verification, and future aerospace digital signal processing concepts. Also considered are CCD architecture for spacecraft SAR image processing, avionics software development for the B-1 aircraft, and software sneak analysis.

Source record↗

Satellite onboard feature classification using CCD's

In this paper discrete time analog signal processing applications of CCD's are discussed. The types of computations which can be performed in the CCD technology are discussed and compared with respect to their accuracy and required support hardware. The classification problem encountered in the reduction of multispectral data into features of terrestrial interest are decomposed into a CCD technology based hardware solution. The resulting system is readily implemented with existing and anticipated CCD devices. This system will be projected to spacecraft application.

Benz, H. F.↗

The HEAO-B Monitor Proportional Counter Instrument

The Monitor Proportional Counter Instrument for the HEAO-B X-ray Telescope satellite is designed to observe celestial X-ray sources in the range of 1 to 20 keV with intensities exceeding .0002 Crab. It provides both spectral and temporal data, to complement the data from the other HEAO-B instruments, to compare with observations from previous flights, as well as to allow detailed study of time variant X-ray phenomena. The basic detector is a large area proportional counter system, consisting of two counters, high voltage power supplies and preamplifiers, mounted behind a collimator with a 2/3 degree square field of view. The signal processing, power distribution and control electronics are contained in a separate unit, which includes circuitry to perform pulse height analysis, background rejection, time interval measurement, redundancy switching and control, housekeeping and telemetry interfacing.

Gaillardetz, R.↗

Azimuth correlator design for IC chip

Azimuth correlator circuit synthetic-aperature radar (SAR) is designed for single integrated circuit (IC) chip. Azimuth correlator modules constructed with sets of such chips could make real-time signal processing possible. Primary advantages are realized in areas of weight and power requirement reductions.

Tyree, V. C.↗

Frequency domain measurement systems

Stable frequency sources and signal processing blocks were characterized by their noise spectra, both discrete and random, in the frequency domain. Conventional measures are outlined, and systems for performing the measurements are described. Broad coverage of system configurations which were found useful is given. Their functioning and areas of application are discussed briefly. Particular attention is given to some of the potential error sources in the measurement procedures, system configurations, double-balanced-mixer-phase-detectors, and application of measuring instruments.

Eischer, M. C.↗

CCD research

The fundamental problems encountered in designing, fabricating, and applying CCD's are reviewed. Investigations are described and results and conclusions are given for the following: (1) the development of design analyses employing computer aided techniques and their application to the design of a grapped structure; (2) the role of CCD's in applications to electronic functions, in particular, signal processing; (3) extending the CCD to silicon films on sapphire (SOS); and (4) all aluminum transfer structure with low noise input-output circuits. Related work on CCD imaging devices is summarized.

Gassaway, J. D.↗

Development of a microwave multilateration system for VTOL landing guidance

An experimental microwave multilateration system has been developed by NASA to provide highly accurate position and velocity measurements during the approach and landing phase of VTOL aircraft. The system uses an angle modulated ranging signal to provide both range and range rate measurements between an aircraft transponder and multiple ground stations. Range and range rate measurements are converted to coordinate measurements, and the coordinate information is transmitted via an integral data link to the aircraft. This paper describes the development of the multilateration system and the associated digital signal processing techniques. Advantages and disadvantages of several processing techniques are discussed. The operation and accuracy of the system as determined from both analytical studies and flight experiments will be described.

Britt, C. L., Jr.↗

The airborne Laser Absorption Spectrometer - A new instrument of remote measurement of atmospheric trace gases

The Laser Absorption Spectrometer is a portable instrument developed by JPL for remote measurement of trace gases from an aircraft platform. It contains two carbon dioxide lasers, two optical heterodyne receivers, appropriate optics to aim the lasers at the ground and detect the backscattered energy, and signal processing and recording electronics. Operating in the differential-absorption mode, it is possible to monitor one atmospheric gas at a time and record the data in real time. The system can presently measure ozone, ethylene, water vapor, and chlorofluoromethanes with high sensitivity. Airborne measurements were made in early 1977 from the NASA/JPL twin-engine Beechcraft and in May 1977 from the NASA Convair 990 during the ASSESS-II Shuttle Simulation Study. These flights resulted in measurements of ozone concentrations in the lower troposphere which were compared with ground-based values provided by the Air Pollution Control District. This paper describes the details of the instrument and results of the airborne measurements.

Shumate, M. S.↗

A digital strategy for manometer dynamic enhancement

Application of digital signal processing techniques to improve the non-linear dynamic characteristics of a sonar-type mercury manometer is described. The dynamic enhancement strategy quasi-linearizes the manometer characteristics and improves the effective bandwidth in the context of a wind-tunnel pressure regulation system. Model identification data and real-time hybrid simulation data demonstrate feasibility of approach.

Stoughton, J. W.↗

A gas filter correlation analyzer for methane

A fast-response instrument for monitoring CH4 was designed and tested using a modified nondispersive infrared technique. An analysis of the single-beam rotating-cell system is presented along with the signal processing circuit. A calibration of the instrument shows that the technique can be used to measure CH4 concentrations as small as 5 ppm-m and the effects of interfering gases are analyzed.

Sebacher, D. I.↗

Performance analysis of pulse Doppler digital radars with application to the Shuttle Ku-band system

A pulse Doppler digital radar is one of the primary components of the Ku-band integrated radar and communication equipment on the Space Shuttle. The performance of the Ku-band rendezvous radar to be used on the Space Shuttle is analyzed in four parts. First an overall functional block diagram description is presented to illustrate the signal processing in the detection and the tracking modes. The detection capabilities and limitations of the radar are investigated taking all of the system losses into account. A new unified analysis of digital radar tracking loops is developed which takes into consideration the effects of a scintillating target and receiver front end noise. The behavior of the radar is discussed in the presence of thermal noise, amplitude scintillation, and target glint.

Alem, W. K.↗

Nuclear Science Symposium, 25th, and Symposium on Nuclear Power Systems, 10th, Washington, D.C., October 18-20, 1978, Proceedings

Detectors of various types are discussed, taking into account drift chambers, calorimetry, multiwire proportional chambers, signal processing, the use of semiconductors, and photo/optical applications. Circuits are considered along with instrumentation for space, nuclear medicine instrumentation, data acquisition and systems, environmental instrumentation, reactor instrumentation, and nuclear power systems. Attention is given to a new approach to high accuracy gaseous detectors, the current status of electron mobility and free-ion yield in high mobility liquids, a digital drift chamber digitizer system, the stability of oxides in high purity germanium, the quadrant photomultiplier, and the theory of imaging with a very limited number of projections.

Source record↗

A structural model of the adaptive human pilot

A compensatory tracking model of the human pilot is offered which attempts to provide a more realistic representation of the human's signal processing structure than that which is exhibited by pilot models currently in use. Two features of the model distinguish it from other representations of the human pilot. First, proprioceptive information from the control stick or manipulator constitutes one of the major feedback paths in the model, providing feedback of vehicle output rate due to control activity. Implicit in this feedback loop is a model of the vehicle dynamics which is valid in and beyond the region of crossover. Second, error-rate information is continuously derived and independently but intermittently controlled. An output injected remnant model is offered and qualitatively justified on the basis of providing a measure of the effect of inaccuracies such as time variations in the pilot's internal model of the controlled element dynamics. The data from experimental tracking tasks involving five different controlled element dynamics and one nonideal viewing condition were matched with model generated describing functions and remnant power spectral densities.

Hess, R. A.↗

CDS solid state phase insensitive ultrasonic transducer

A phase insensitive ultrasonic transducer which includes a CdS crystal that is annealed for a selected period of time and at a selected temperature to provide substantially maximum acoustic attenuation at the operating frequency of the transducer is described. Two electrodes are attached to the crystal with amplifier means and a signal processing system connected to one of the electrodes to provide an ultrasonic receiver.

Heyman, J. S.↗

Ultramicrowave communications system, phase 2

Communications system design was completed and reviewed. Minor changes were made in order to make it more cost effective and to increase design flexibility. System design activities identified the techniques and procedures to generate and monitor high data rate test signals. Differential bi-phase demodulation is the proposed method for this system. The mockup and packaging designs were performed, and component layout and interconnection constraints were determined, as well as design drawings for dummy parts of the system. The possibility of adding a low cost option to the transceiver system was studied. The communications program has the advantage that new technology signal processing devices can be readily interfaced with the existing radio frequency subsystem to produce a short range radar.

Source record↗

Design, fabrication and testing of an optical temperature sensor

The laboratory breadboard optical temperature sensor based on the temperature dependent absorptive characteristics of a rare earth (europium) doped optical fiber. The principles of operation, materials characterization, fiber and optical component design, design and fabrication of an electrooptic interface unit, signal processing, and initial test results are discussed. Initial tests indicated that, after a brief warmup period, the output of the sensor was stable to approximately 1 C at room temperature or approximately + or - 0.3 percent of point (K). This exceeds the goal of 1 percent of point. Recommendations are presented for further performance improvement.

Morey, W. W.↗

Faint-object spectrograph for Space Telescope

The paper presents the Faint Object Spectrograph (FOS) for the Space Telescope to provide a digitized spectra of faint astronomical objects over the 115 to 700 nm wavelength range at resolving powers of 1000 and 100. A variety of concave gratings and prisms is employed to form nearly stigmatic spectra on one of the two Digicon photon counting detectors which are optimized for two different but overlapping ranges. The scientific goals associated with quasars, active galaxies, and objects within our solar system are discussed, and the FOS optical design features, including detectors, electronics, signal processing, power supplies, and data handling are examined. The FOS structural system, mechanism, and controls are described, along with the predicted performance capabilities in the spectral and spectropolarimetry modes. Finally, system performance parameters, including spatial resolution, time resolution, noise, and efficiency are discussed.

Harms, r. J.↗

DUMAND Summer Workshop, University of California, La Jolla, Calif., July 24-September 2, 1978, Proceedings. Volume 3 - Oceanographic and ocean engineering studies

The DUMAND (Deep Underwater Muon and Neutrino Detector) array, a hexagon 800 m on a side, 673 m high, and consisting of 22,698 sensor modules, is designed to detect neutrinos in the TeV range, hadronic cascades, muons and Cerenkov radiation. Its engineering, signal processing, and logistic aspects are considered, as are its optical detection (photomultiplier tubes) system and electronics. Geological and bottom current surveys were made at two proposed sites for the array (the Maui and Keahole Point basins of Hawaii), and a study of the steady-state response of a sensor string to current drag forces is reported. Biological interference with the DUMAND array, including mechanical entanglement by large animals, bioluminescence, and especially biofouling are considered, as well as the deployment, implantment and maintenance of the array.

Wilkins, G.↗