Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “STORAGE RING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 793 records · Page 44

Reduction of Coherent Betatron Oscillations Using RF Electric Fields in the Fermilab Muon g-2 Experiment

The Fermilab Muon g-2 experiment aims to measure the muon anomalous magnetic moment with a 140 parts-per-billion precision to investigate the greater than 3 standard deviation difference between the Standard Model prediction and the previous measurement by the BNL Muon g-2 experiment. The coherent betatron oscillation (CBO) beam effects must be corrected for in the decay-positron time spectra fits used in high precision muon storage ring based anomalous magnetic moment measurements. This MC simulation study indicates that the application of radio frequency (RF) electric fields to the muon storage ring beam can reduce the CBO amplitude by up to a factor of 10, as well to increase the symmetry of the beam phase space. This is achieved by correcting the mismatched oscillation phases between the high and low momentum muon populations by modulating the muon beam betatron oscillation frequencies with off-resonance RF fields.

43 PARTICLE ACCELERATORS↗

Validation of Analytical Calculations for the NSLS-II Injection Shutters with FLUKA Monte-Carlo Program

The NSLS-II injector consists of a 200 MeV linac and a 3.0 GeV booster synchrotron for beam injection into the 3.0 GeV electron storage ring. The linac serves as the initial accelerator for the facility and is designed to produce 15nC/pulse at 200 MeV. The linac typically operates at a 1Hz rep rate. The linac injects 200 MeV electron pulses to the booster synchrotron to be accelerated to the energy of 3.0 GeV. The injection process to the booster is done through a transfer line from the linac to the booster ring. Similarly, the booster serves as the accelerating synchrotron to ramp up the electron energy to 3.0 GeV before being injected into the storage ring through a transfer line.

36 MATERIALS SCIENCE↗

Development of a Bunched Beam Electron Cooler based on ERL and Circulator Ring Technology for the Jefferson Lab Electron-Ion Collider

Jefferson Lab is in the process of designing an electron ion collider with unprecedented luminosity at a 45 GeV center-of-mass energy. This luminosity relies on ion cooling in both the booster and the storage ring of the accelerator complex. The cooling in the booster will use a conventional DC cooler similar to the one at COSY. The high-energy storage ring, operating at a momentum of up to 100 GeV/nucleon, requires novel use of bunched-beam cooling. There are two designs for such a cooler. The first uses a conventional Energy Recovery Linac (ERL) with a magnetized beam while the second uses a circulating ring to enhance both peak and average currents experienced by the ion beam. This presentation will describe the design of both the Circulator Cooling Ring (CCR) design and that of the backup option using the stand-alone ERL operated at lower charge but higher repetition rate than the ERL injector required by the CCR-based design.

Benson, Stephen V.↗

Development of a bunched beam electron cooler for the Jefferson Lab electron-ion collider

Jefferson Lab is in the process of designing an electron-ion collider with unprecedented luminosity at a 65 GeV center-of-mass energy. This luminosity relies on ion cooling in both the booster and the storage ring of the accelerator complex. The cooling in the booster will use a conventional DC cooler similar to the one at COSY. The high-energy storage ring, operating at a momentum of up to 100 GeV/nucleon, requires novel use of bunched-beam cooling. We will present a new design for a Circulator Cooler Ring for bunched-beam electron cooling. This requires the generation and transport of very high-charge magnetized bunches, acceleration of the bunches in an energy recovery linac, and transfer of these bunches to a circulating ring that passes the bunches 11 times through the proton or ion beam inside cooling solenoids. This design requires the suppression of the effects of space charge and coherent synchrotron radiation using shielding and RF compensation.

Benson, Stephen V.↗

Evaluation of BPM Button Geometry for NSLS-II Project

The NSLS-II storage ring will provide a light source with unprecedented brightness. To utilize fully ultra-low emittance of electron beam we need to keep orbit in the storage ring with high precision. This paper presents mathematical modeling of different geometries of beam position monitor buttons, including button diameter and horizontal separation of button centers. The results of modeling are used for the optimization of BPM sensitivity to beam displacement and estimation of signal levels.

36 MATERIALS SCIENCE↗

Evaluation of BPM Button Geometry for NSLS-II Project

The NSLS-II storage ring will provide a light source with unprecedented brightness. To utilize fully ultra-low emittance of electron beam we need to keep orbit in the storage ring with high precision. This paper presents mathematical modeling of different geometries of beam position monitor buttons, including button diameter and horizontal separation of button centers. The results of modeling are used for the optimization of BPM sensitivity to beam displacement and estimation of signal levels.

36 MATERIALS SCIENCE↗

Dielectronic Recombination In Active Galactic Nuclei

XMM-Newton and Chandra observations of active galactic nuclei (AGN) show rich spectra of X-ray absorption lines. These observations have detected a broad unresolved transition array (UTA) between approx. 15-17 A. This is attributed to inner-shell photoexcitation of M-shell iron ions. Modeling these UTA features is currently limited by uncertainties in the low-temperature dielectronic recombination (DR) data for M-shell iron. In order to resolve this issue, and to provide reliable iron M-shell DR data for plasma modeling, we are carrying out a series of laboratory measurements using the heavy-ion Test Storage Ring (TSR) at the Max-Plank-Institute for Nuclear Physics in Heidelberg, Germany. Currently, laboratory measurements of low temperature DR can only be performed at storage rings. We use the DR data obtained at TSR, to calculate rate coefficients for plasma modeling and to benchmark theoretical DR calculations. Here we report our recent experimental results for DR of Fe XIV forming Fe XIII.

Lukic, D. V.↗

Experimental 3-dimensional tracking of the dynamics of a single electron in the Fermilab Integrable Optics Test Accelerator (IOTA)

We present the results of experimental studies on the transverse and longitudinal dynamics of a single electron in the IOTA storage ring. IOTA is a flexible machine dedicated to beam physics experiments with electrons and protons. A method was developed to reliably inject and circulate a controlled number of electrons in the ring. A key beam diagnostic system is the set of sensitive high-resolution digital cameras for the detection of synchrotron light emitted by the electrons. With 60–130 electrons in the machine, we measured beam lifetime and derived an absolute calibration of the optical system. At exposure times of 0.5 s, the cameras were sensitive to individual electrons. Camera images were used to reconstruct the time evolution of oscillation amplitudes of a single electron in all 3 degrees of freedom. The evolution of amplitudes directly showed the interplay between synchrotron-radiation damping, quantum excitations, and scattering with the residual gas. From the distribution of measured single-electron oscillation amplitudes, we deduced transverse emittances, momentum spread, damping times, and beam energy. Estimates of residual-gas density and composition were calculated from the measured distributions of vertical scattering angles. Combining scattering and lifetime data, we also provide an estimate of the aperture of the ring. To our knowledge, this is the first time that the dynamics of a single electron are tracked in all three dimensions with digital cameras in a storage ring.

43 PARTICLE ACCELERATORS↗

NSLS-II SR Commissioning Report

The NSLS-II storage ring (SR) phase I commissioning has been successfully completed in May 12, 2014. In accordance to the project milestone, 25 mA average current was achieved in the storage ring with PETRA III 500 MHz 7-cell PETRA-III RF cavity but w/o ID’s and Landau cavities. In about 5 weeks we delivered a 3 GeV beam to the ring injection straight section, made the 1st turn around the ring, achieved hundreds of turns optimizing injection, stored beam having sextupoles and RF turned ON. Injection efficiency was achieved 95%, close orbit rms value is ~100 um, tune and chromaticity were measured and adjusted as desired, and beam lifetime was a few hours depending on the stored beam current. This report consists of a summary, a chronological part, the injector system performance in Ch3, SR commissioning experience in Ch4 and the outlook of remaining work in Ch5. The SR commissioning experience includes the software experience, hardware (timing, diagnostics, RF, vacuum, PS) operation experience, the strategy for initial injection beam to the stored beam, measurement of the linear optics and control to the desired value, nonlinear beam dynamics study, beam instability study, the subsystem reliability and fault study at different scenarios.

36 MATERIALS SCIENCE↗

Radiometry using synchrotron radiation

It is possible to use synchrotron radiation from electron synchrotrons and electron storage rings as an absolute source, especially in the VUV and soft X-ray regions where other standards are difficult to find. At the NBS, an electron storage ring (SURF-II) has been used to calibrate spectrometers and photometers utilized in solar and aeronomy research and in fusion plasma diagnostics. The radiation incident on these spectrometers can be calculated to uncertainties of 3%, and a technique to exactly determine the number of electrons orbiting in the ring is currently being developed to reduce this uncertainty. Detector calibrations between 5 and 55 nm are routinely performed at SURF-II and transfer standard detectors with 6-10% uncertainties over the range 5-254 nm are supplied.

Saloman, E. B.↗

Measurement of the muon anomalous precession frequency in runs 4, 5, and 6 of the muon ${g}-2$ Experiment at Fermilab

The Fermilab E989 Muon $g-2$ experiment measures the muon's anomalous magnetic moment to a precision of 127 parts per billion, as reported in June 2025. The value is proportional to the difference between the muon's cyclotron frequency and the spin precession frequency in the presence of a uniform magnetic field, for muons contained within the $g-2$ storage ring. Spin precession frequency is extracted from the time distribution of the muon's decay positrons recorded by 24 electromagnetic calorimeters positioned around the inner circumference of the storage ring. The anomalous precession frequency is one of the primary experimental inputs necessary to estimate the anomalous magnetic moment, the other being the measurement of the magnetic field. This dissertation details the anomalous precession frequency extraction, including reconstruction, time-distribution fitting, and treatment of systematic uncertainties for the final three data-collection runs: Run-4, Run-5, and Run-6. This data represents a fourfold increase in statistics over the previous analysis release, halving the statistical uncertainty. The residual slow term from previous analyses is now well understood and documented in a systematic treatment. As of the writing of this dissertation, the theoretical prediction for the SM estimate of the muon's anomalous magnetic moment is under debate, with two competing prediction methods, so a definitive comparison with theory is not available. The results submitted for experimental release use the kernel-ratio asymmetry method, contributing 115 parts per billion to the statistical uncertainty and 34 parts per billion to the systematic uncertainty. When combined with the previous analyses in earlier data runs, this thereby improves the measurement beyond the experimental goal and sets the world's most precise measurement of the muon's anomalous magnetic moment.

Israel, Scott Nathan [Boston U.]↗

Measurement of the muon anomalous precession frequency in runs 4, 5, and 6 of the muon ${g}-2$ Experiment at Fermilab

The Fermilab E989 Muon $g-2$ experiment measures the muon's anomalous magnetic moment to a precision of 127 parts per billion, as reported in June 2025. The value is proportional to the difference between the muon's cyclotron frequency and the spin precession frequency in the presence of a uniform magnetic field, for muons contained within the $g-2$ storage ring. Spin precession frequency is extracted from the time distribution of the muon's decay positrons recorded by 24 electromagnetic calorimeters positioned around the inner circumference of the storage ring. The anomalous precession frequency is one of the primary experimental inputs necessary to estimate the anomalous magnetic moment, the other being the measurement of the magnetic field. This dissertation details the anomalous precession frequency extraction, including reconstruction, time-distribution fitting, and treatment of systematic uncertainties for the final three data-collection runs: Run-4, Run-5, and Run-6. This data represents a fourfold increase in statistics over the previous analysis release, halving the statistical uncertainty. The residual slow term from previous analyses is now well understood and documented in a systematic treatment. As of the writing of this dissertation, the theoretical prediction for the SM estimate of the muon's anomalous magnetic moment is under debate, with two competing prediction methods, so a definitive comparison with theory is not available. The results submitted for experimental release use the kernel-ratio asymmetry method, contributing 115 parts per billion to the statistical uncertainty and 34 parts per billion to the systematic uncertainty. When combined with the previous analyses in earlier data runs, this thereby improves the measurement beyond the experimental goal and sets the world's most precise measurement of the muon's anomalous magnetic moment.

Israel, Scott Nathan [Boston U.]↗

Measurement of the muon anomalous precession frequency in Runs 4, 5, and 6 of the Muon g-2 experiment at Fermilab

The Fermilab E989 Muon g − 2 experiment measures the muon’s anomalous magnetic moment to a precision of 127 parts per billion, as reported in June 2025. The value is proportional to the difference between the muon’s cyclotron frequency and the spin precession frequency in the presence of a uniform magnetic field, for muons contained within the g − 2 storage ring. Spin precession frequency is extracted from the time distribution of the muon’s decay positrons recorded by 24 electromagnetic calorimeters positioned around the inner circumference of the storage ring. The anomalous precession frequency is one of the primary experimental inputs necessary to estimate the anomalous magnetic moment, the other being the measurement of the magnetic field. This dissertation details the anomalous precession frequency extraction, including reconstruction, time-distribution fitting, and treatment of systematic uncertainties for the final three data-collection runs: Run-4, Run-5, and Run-6. This data represents a fourfold increase in statistics over the previous analysis release, halving the statistical uncertainty. The residual slow term from previous analyses is now well understood and documented in a systematic treatment. As of the writing of this dissertation, the theoretical prediction for the SM estimate of the muon’s anomalous magnetic moment is under debate, with two competing prediction methods, so a definitive comparison with theory is not available. The results submitted for experimental release use the kernel-ratio asymmetry method, contributing 115 parts per billion to the statistical uncertainty and 34 parts per billion to the systematic uncertainty. When combined with the previous analyses in earlier data runs, this thereby improves the measurement beyond the experimental goal and sets the world’s most precise measurement of the muon’s anomalous magnetic moment.

Israel, Scott Nathan [Boston U.]↗

Measurement of the muon anomalous precession frequency $\omega_a$ in the Fermilab $g-2$ experiment

The Fermilab Muon $g-2$ Experiment was designed to measure the muon's anomalous magnetic moment $a_{\mu} = (g-2)/2$ to 140 parts per billion. The value of $a_{\mu}$ is proportional to the difference frequency $\omega_a=\omega_s-\omega_c$ between the muon's cyclotron frequency and spin precession frequency in the uniform magnetic field of the $g-2$ storage ring. The frequency $\omega_a$ is extracted from the time distribution of the mu-decay positrons recorded by 24 electromagnetic calorimeters positioned around the inner circumference of the storage ring. We will discuss the various approaches to the frequency determination including the reconstruction, fitting of time distributions, and procedures for handling the effects of gain changes, positron pileup and beam dynamics. We also discuss the data consistency checks and the strategy for the averaging of $\omega_a$ across the different analyses.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Component Database for the APS Upgrade

The Advanced Photon Source Upgrade (APS-U) project will replace the existing APS storage ring with a multi-bend achromat (MBA) lattice to provide extreme transverse coherence and extreme brightness x-rays to its users. As the time to replace the existing storage ring accelerator is of critical concern, an aggressive one-year removal/installation/testing period is being planned. To aid in the management of the thousands of components to be installed in such a short time, the Component Database (CDB) application is being developed with the purpose to identify, document, track, locate, and organize components in a central database. Three major domains are being addressed: Component definitions (which together make up an exhaustive "Component Catalog"), Designs (groupings of components to create subsystems), and Component Instances (“Inventory”). Relationships between the major domains offer additional "system knowledge" to be captured that will be leveraged with future tools and applications. It is imperative to provide sub-system engineers with a functional application early in the machine design cycle. Topics discussed in this paper include the initial design and deployment of CDB, as well as future development plans.

Veseli, S.↗

Dedicated beam position monitor pair for model-independent lattice characterization at NSLS-II

This paper reports recent lattice characterization results obtained at the National Synchrotron Light Source II (NSLS-II) storage ring, conducted without reliance on a lattice model. A pair of beam position monitors (BPMs) with bunch-by-bunch (B×B) resolution, were recently installed in a section of the storage ring free of magnetic fields. The new BPM pair measured the beam, or bunch’s transverse Poincar´e map precisely after the beam was excited. Linear one-turn-matrices (OTM) were then derived, and from these, the 4-dimensional coupled Twiss parameters were extracted at the locations of the BPM pair. By normalizing beam oscillation amplitudes with the Twiss parameters, the global action-variables were obtained. These action-variables facilitated the measurement of the local Twiss parameters observed by other BPMs independent on lattice model. This method is general, and particularly useful in certain scenarios such as a round beam mode in a diffraction-limited light source ring. We applied it to assess both weakly and strongly coupled lattices at the NSLS-II ring. Through analysis of the strongly coupled lattice, the quadrupole tilt errors were estimated to be less than 400 µrad. Utilizing the BPMs’ B×B resolution, for the first time we observed the variations of the linear lattice along a long bunch-train.

43 PARTICLE ACCELERATORS↗

Dedicated beam position monitor pair for model-independent lattice characterization at NSLS-II

This paper reports recent lattice characterization results obtained at the National Synchrotron Light Source II (NSLS-II) storage ring, conducted without reliance on a lattice model. A pair of beam position monitors (BPMs) with bunch-by-bunch (B$\times$B) resolution, were recently installed in a section of the storage ring free of magnetic fields. The new BPM pair measured the beam, or bunch’s transverse Poincaré map precisely after the beam was excited. Linear one-turn-matrices (OTM) were then derived, and from these, the 4-dimensional coupled Twiss parameters were extracted at the locations of the BPM pair. By normalizing beam oscillation amplitudes with the Twiss parameters, the global action-variables were obtained. Additionally, these action-variables facilitated the measurement of the local Twiss parameters observed by other BPMs independent on lattice model. This method is general, and particularly useful in certain scenarios such as a round beam mode in a diffraction-limited light source ring. We applied it to assess both weakly and strongly coupled lattices at the NSLS-II ring. Through analysis of the strongly coupled lattice, the quadrupole tilt errors were estimated to be less than 400 μrad. Utilizing the BPMs’ B$\times$B resolution, for the first time we observed the variations of the linear lattice along a long bunch-train.

36 MATERIALS SCIENCE↗

Vacuum system design, construction, and operation for the Cornell High Energy Synchrotron Source upgrade

During the summer and fall 2018, the Cornell High Energy Synchrotron Source (CHESS), underwent an upgrade that recast the facility as primarily a low emittance X-ray source. The upgrade replaced one sixth of the Cornell Electron Storage Ring (CESR) with six double-bend achromats, featuring four novel CHESS Compact Undulator (CCU) insertion devices, and switched CESR to single particle beam operation. At the time of this writing, the upgraded storage ring has achieved the CHESS-U design goal of operating with 200 mA of positron current at 6.0 GeV beam energy. Additionally, seven out of eleven CHESS-U beamlines are currently in X-ray user operation. The construction and the commissioning of the new section of the CESR accelerator required novel solutions to design, fabrication, and vacuum system operations. Significant design considerations and efforts were made to minimize X-ray ‘dark-time’, returning to operation less than 1 year. This paper describes the important milestones of the process, the solutions implemented, and the present status of CHESS-U.

43 PARTICLE ACCELERATORS↗