Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “STALLING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 793 records · Page 44

High Efficiency Centrifugal Compressor for Rotorcraft Applications

The report "High Efficiency Centrifugal Compressor for Rotorcraft Applications" documents the work conducted at UTRC under the NRA Contract NNC08CB03C, with cost share 2/3 NASA, and 1/3 UTRC, that has been extended to 4.5 years. The purpose of this effort was to identify key technical barriers to advancing the state-of-the-art of small centrifugal compressor stages; to delineate the measurements required to provide insight into the flow physics of the technical barriers; to design, fabricate, install, and test a state-of-the-art research compressor that is representative of the rear stage of an axial-centrifugal aero-engine; and to acquire detailed aerodynamic performance and research quality data to clarify flow physics and to establish detailed data sets for future application. The design activity centered on meeting the goal set outlined in the NASA solicitation-the design target was to increase efficiency at higher work factor, while also reducing the maximum diameter of the stage. To fit within the existing Small Engine Components Test Facility at NASA Glenn Research Center (GRC) and to facilitate component re-use, certain key design parameters were fixed by UTRC, including impeller tip diameter, impeller rotational speed, and impeller inlet hub and shroud radii. This report describes the design effort of the High Efficiency Centrifugal Compressor stage (HECC) and delineation of measurements, fabrication of the compressor, and the initial tests that were performed. A new High-Efficiency Centrifugal Compressor stage with a very challenging reduction in radius ratio was successfully designed, fabricated and installed at GRC. The testing was successful, with no mechanical problems and the running clearances were achieved without impeller rubs. Overall, measured pressure ratio of 4.68, work factor of 0.81, and at design exit corrected flow rate of 3 lbm/s met the target requirements. Polytropic efficiency of 85.5 percent and stall margin of 7.5 percent were measured at design flow rate and speed. The measured efficiency and stall margin were lower than pre-test CFD predictions by 2.4 percentage points (pt) and 4.5 pt, respectively. Initial impressions from the experimental data indicated that the loss in the efficiency and stall margin can be attributed to a design shortfall in the impeller. However, detailed investigation of experimental data and post-test CFD simulations of higher fidelity than pre-test CFD, and in particular the unsteady CFD simulations and the assessment with a wider range of turbulence models, have indicated that the loss in efficiency is most likely due to the impact of unfavorable unsteady impeller/diffuser interactions induced by diffuser vanes, an impeller/diffuser corrected flow-rate mismatch (and associated incidence levels), and, potentially, flow separation in the radial-to-axial bend. An experimental program with a vaneless diffuser is recommended to evaluate this observation. A subsequent redesign of the diffuser (and the radial-to-axial bend) is also recommended. The diffuser needs to be redesigned to eliminate the mismatching of the impeller and the diffuser, targeting a slightly higher flow capacity. Furthermore, diffuser vanes need to be adjusted to align the incidence angles, to optimize the splitter vane location (both radially and circumferentially), and to minimize the unsteady interactions with the impeller. The radial-to-axial bend needs to be redesigned to eliminate, or at least minimize, the flow separation at the inner wall, and its impact on the flow in the diffuser upstream. Lessons were also learned in terms of CFD methodology and the importance of unsteady CFD simulations for centrifugal compressors was highlighted. Inconsistencies in the implementation of a widely used two-equation turbulence model were identified and corrections are recommended. It was also observed that unsteady simulations for centrifugal compressors require significantly longer integration times than what is current practice in industry.

Gorazd Medic↗

High Efficiency Centrifugal Compressor for Rotorcraft Applications

The report "High Efficiency Centrifugal Compressor for Rotorcraft Applications" documents the work conducted at UTRC under the NRA Contract NNC08CB03C, with cost share 2/3 NASA, and 1/3 UTRC, that has been extended to 4.5 years. The purpose of this effort was to identify key technical barriers to advancing the state-of-the-art of small centrifugal compressor stages; to delineate the measurements required to provide insight into the flow physics of the technical barriers; to design, fabricate, install, and test a state-of-the-art research compressor that is representative of the rear stage of an axial-centrifugal aero-engine; and to acquire detailed aerodynamic performance and research quality data to clarify flow physics and to establish detailed data sets for future application. The design activity centered on meeting the goal set outlined in the NASA solicitation-the design target was to increase efficiency at higher work factor, while also reducing the maximum diameter of the stage. To fit within the existing Small Engine Components Test Facility at NASA Glenn Research Center (GRC) and to facilitate component re-use, certain key design parameters were fixed by UTRC, including impeller tip diameter, impeller rotational speed, and impeller inlet hub and shroud radii. This report describes the design effort of the High Efficiency Centrifugal Compressor stage (HECC) and delineation of measurements, fabrication of the compressor, and the initial tests that were performed. A new High-Efficiency Centrifugal Compressor stage with a very challenging reduction in radius ratio was successfully designed, fabricated and installed at GRC. The testing was successful, with no mechanical problems and the running clearances were achieved without impeller rubs. Overall, measured pressure ratio of 4.68, work factor of 0.81, and at design exit corrected flow rate of 3 lbm/s met the target requirements. Polytropic efficiency of 85.5 percent and stall margin of 7.5 percent were measured at design flow rate and speed. The measured efficiency and stall margin were lower than pre-test CFD predictions by 2.4 percentage points (pt) and 4.5 pt, respectively. Initial impressions from the experimental data indicated that the loss in the efficiency and stall margin can be attributed to a design shortfall in the impeller. However, detailed investigation of experimental data and post-test CFD simulations of higher fidelity than pre-test CFD, and in particular the unsteady CFD simulations and the assessment with a wider range of turbulence models, have indicated that the loss in efficiency is most likely due to the impact of unfavorable unsteady impeller/diffuser interactions induced by diffuser vanes, an impeller/diffuser corrected flow-rate mismatch (and associated incidence levels), and, potentially, flow separation in the radial-to-axial bend. An experimental program with a vaneless diffuser is recommended to evaluate this observation. A subsequent redesign of the diffuser (and the radial-to-axial bend) is also recommended. The diffuser needs to be redesigned to eliminate the mismatching of the impeller and the diffuser, targeting a slightly higher flow capacity. Furthermore, diffuser vanes need to be adjusted to align the incidence angles, to optimize the splitter vane location (both radially and circumferentially), and to minimize the unsteady interactions with the impeller. The radial-to-axial bend needs to be redesigned to eliminate, or at least minimize, the flow separation at the inner wall, and its impact on the flow in the diffuser upstream. Lessons were also learned in terms of CFD methodology and the importance of unsteady CFD simulations for centrifugal compressors was highlighted. Inconsistencies in the implementation of a widely used two-equation turbulence model were identified and corrections are recommended. It was also observed that unsteady simulations for centrifugal compressors require significantly longer integration times than what is current practice in industry.

Gorazd Medic↗

Modeling the Deterioration of Engine and Low Pressure Compressor Performance During a Roll Back Event Due to Ice Accretion

The main focus of this study is to apply a computational tool for the flow analysis of the engine that has been tested with ice crystal ingestion in the Propulsion Systems Laboratory (PSL) of NASA Glenn Research Center. A data point was selected for analysis during which the engine experienced a full roll back event due to the ice accretion on the blades and flow path of the low pressure compressor. The computational tool consists of the Numerical Propulsion System Simulation (NPSS) engine system thermodynamic cycle code, and an Euler-based compressor flow analysis code, that has an ice particle melt estimation code with the capability of determining the rate of sublimation, melting, and evaporation through the compressor blade rows. Decreasing the performance characteristics of the low pressure compressor (LPC) within the NPSS cycle analysis resulted in matching the overall engine performance parameters measured during testing at data points in short time intervals through the progression of the roll back event. Detailed analysis of the fan-core and LPC with the compressor flow analysis code simulated the effects of ice accretion by increasing the aerodynamic blockage and pressure losses through the low pressure compressor until achieving a match with the NPSS cycle analysis results, at each scan. With the additional blockages and losses in the LPC, the compressor flow analysis code results were able to numerically reproduce the performance that was determined by the NPSS cycle analysis, which was in agreement with the PSL engine test data. The compressor flow analysis indicated that the blockage due to ice accretion in the LPC exit guide vane stators caused the exit guide vane (EGV) to be nearly choked, significantly reducing the air flow rate into the core. This caused the LPC to eventually be in stall due to increasing levels of diffusion in the rotors and high incidence angles in the inlet guide vane (IGV) and EGV stators. The flow analysis indicating compressor stall is substantiated by the video images of the IGV taken during the PSL test, which showed water on the surface of the IGV flowing upstream out of the engine, indicating flow reversal, which is characteristic of a stalled compressor.

Jorgenson, Philip C. E.↗

Effects of Double-Leakage Tip Clearance Flow on the Performance of a Compressor Stage with a Large Rotor Tip Gap

Effects of a large rotor tip gap on the performance of a one and half stage axial compressor are investigated in detail with a numerical simulation based on LES and available PIV data. The current paper studies the main flow physics, including why and how the loss generation is increased with the large rotor tip gap. The present study reveals that when the tip gap becomes large, tip clearance fluid goes over the tip clearance core vortex and enters into the next blade's tip gap, which is called double-leakage tip clearance flow. As the tip clearance flow enters into the adjacent blade's tip gap, a vortex rope with a lower pressure core is generated. This vortex rope breaks up the tip clearance core vortex of the adjacent blade, resulting in a large additional mixing. This double-leakage tip clearance flow occurs at all operating conditions, from design flow to near stall condition, with the large tip gap for the current compressor stage. The double-leakage tip clearance flow, its interaction with the tip clearance core vortex of the adjacent blade, and the resulting large mixing loss are the main flow mechanism of the large rotor tip gap in the compressor. When the tip clearance is smaller, flow near the end wall follows more closely with the main passage flow and this double-leakage tip clearance flow does not happen near the design flow condition for the current compressor stage. When the compressor with a large tip gap operates at near stall operation, a strong vortex rope is generated near the leading edge due to the double-leakage flow. Part of this vortex separates from the path of the tip clearance core vortex and travels from the suction side of the blade toward the pressure side of the blade. This vortex is generated periodically at near stall operation with a large tip gap. As the vortex travels from the suction side to the pressure side of the blade, a large fluctuation of local pressure forces blade vibration. Nonsynchronous blade vibration occurs due to this vortex as the frequency of this vortex generation is not the same as the rotor. The present investigation confirms that this vortex is a part of separated tip clearance vortex, which is caused by the double-leakage tip clearance flow.

flow↗

Navier-Stokes Simulation of UH-60A Rotor/Wake Interaction Using Adaptive Mesh Refinement

Time-dependent Navier-Stokes simulations have been carried out for a flexible UH-60A rotor in forward flight, where the rotor wake interacts with the rotor blades. These flow conditions involved blade vortex interaction and dynamic stall, two common conditions that occur as modern helicopter designs strive to achieve greater flight speeds and payload capacity. These numerical simulations utilized high-order spatial accuracy and delayed detached eddy simulation. Emphasis was placed on understanding how improved rotor wake resolution affects the prediction of the normal force, pitching moment, and chord force of the rotor. Adaptive mesh refinement was used to highly resolve the turbulent rotor wake in a computationally efficient manner. Moreover, blade vortex interaction was found to trigger dynamic stall. Time-dependent flow visualization was utilized to provide an improved understanding of the numerical and physical mechanisms involved with three-dimensional dynamic stall.

UH-60A RotorWake↗

High Efficiency Centrifugal Compressor for Rotorcraft Applications

The report "High Efficiency Centrifugal Compressor for Rotorcraft Applications" documents the work conducted at UTRC under the NRA Contract NNC08CB03C, with cost share 2/3 NASA, and 1/3 UTRC, that has been extended to 4.5 years. The purpose of this effort was to identify key technical barriers to advancing the state-of-the-art of small centrifugal compressor stages; to delineate the measurements required to provide insight into the flow physics of the technical barriers; to design, fabricate, install, and test a state-of-the-art research compressor that is representative of the rear stage of an axial-centrifugal aero-engine; and to acquire detailed aerodynamic performance and research quality data to clarify flow physics and to establish detailed data sets for future application. The design activity centered on meeting the goal set outlined in the NASA solicitation-the design target was to increase efficiency at higher work factor, while also reducing the maximum diameter of the stage. To fit within the existing Small Engine Components Test Facility at NASA Glenn Research Center (GRC) and to facilitate component re-use, certain key design parameters were fixed by UTRC, including impeller tip diameter, impeller rotational speed, and impeller inlet hub and shroud radii. This report describes the design effort of the High Efficiency Centrifugal Compressor stage (HECC) and delineation of measurements, fabrication of the compressor, and the initial tests that were performed. A new High-Efficiency Centrifugal Compressor stage with a very challenging reduction in radius ratio was successfully designed, fabricated and installed at GRC. The testing was successful, with no mechanical problems and the running clearances were achieved without impeller rubs. Overall, measured pressure ratio of 4.68, work factor of 0.81, and at design exit corrected flow rate of 3 lbm/s met the target requirements. Polytropic efficiency of 85.5 percent and stall margin of 7.5 percent were measured at design flow rate and speed. The measured efficiency and stall margin were lower than pre-test CFD predictions by 2.4 percentage points (pt) and 4.5 pt, respectively. Initial impressions from the experimental data indicated that the loss in the efficiency and stall margin can be attributed to a design shortfall in the impeller. However, detailed investigation of experimental data and post-test CFD simulations of higher fidelity than pre-test CFD, and in particular the unsteady CFD simulations and the assessment with a wider range of turbulence models, have indicated that the loss in efficiency is most likely due to the impact of unfavorable unsteady impeller/diffuser interactions induced by diffuser vanes, an impeller/diffuser corrected flow-rate mismatch (and associated incidence levels), and, potentially, flow separation in the radial-to-axial bend. An experimental program with a vaneless diffuser is recommended to evaluate this observation. A subsequent redesign of the diffuser (and the radial-to-axial bend) is also recommended. The diffuser needs to be redesigned to eliminate the mismatching of the impeller and the diffuser, targeting a slightly higher flow capacity. Furthermore, diffuser vanes need to be adjusted to align the incidence angles, to optimize the splitter vane location (both radially and circumferentially), and to minimize the unsteady interactions with the impeller. The radial-to-axial bend needs to be redesigned to eliminate, or at least minimize, the flow separation at the inner wall, and its impact on the flow in the diffuser upstream. Lessons were also learned in terms of CFD methodology and the importance of unsteady CFD simulations for centrifugal compressors was highlighted. Inconsistencies in the implementation of a widely used two-equation turbulence model were identified and corrections are recommended. It was also observed that unsteady simulations for centrifugal compressors require significantly longer integration times than what is current practice in industry.

Centrifugal compressor↗

Adaptive Hexapod Simulator Motion Based on Aircraft Stability

This paper determined the feasibility of an adaptive hexapod simulator motion algorithm based on aircraft roll stability. An experiment was conducted that used a transport aircraft model in the Vertical Motion Simulator at NASA Ames Research Center. Eighteen general aviation pilots flew a heading-capture task and a stall task consecutively under four motion configurations: baseline hexapod, adaptive hexapod, optimized hexapod, and full motion. The adaptive motion was more similar to the baseline hexapod motion in the heading-capture task when the aircraft was more stable, and more similar to the optimized hexapod motion in the stall task when the aircraft was more unstable. Pilot motion ratings and task performance in the heading-capture task under the adaptive hexapod motion were more similar to baseline hexapod motion compared to optimized hexapod motion. However, motion ratings and task performance in the stall task under the adaptive motion were not significantly more similar to the optimized hexapod motion compared to baseline hexapod motion. Motion ratings and overall task performance under optimized hexapod motion as opposed to baseline hexapod motion were always more similar to the full motion condition. This paper showed that adaptive motion based on aircraft stability is feasible and can be implemented in a straightforward way. More research is required to test the adaptive motion algorithm in different tasks.

Zaal, Peter M. T.↗

Evaluation of Technology Concepts for Energy, Automation, and System State Awareness in Commercial Airline Flight Decks

A pilot-in-the-loop flight simulation study was conducted at NASA Langley Research Center to evaluate flight deck systems that (1) provide guidance for recovery from low energy states and stalls, (2) present the current state and expected future state of automated systems, and/or (3) show the state of flight-critical data systems in use by automated systems and primary flight instruments. The study was conducted using 13 commercial airline crews from multiple airlines, paired by airline to minimize procedural effects. Scenarios spanned a range of complex conditions and several emulated causal and contributing factors found in recent accidents involving loss of state awareness by pilots (e.g., energy state, automation state, and/or system state). Three new technology concepts were evaluated while used in concert with current state-of-the-art flight deck systems and indicators. The technologies include a stall recovery guidance algorithm and display concept, an enhanced airspeed control indicator that shows when automation is no longer actively controlling airspeed, and enhanced synoptic pages designed to work with simplified interactive electronic checklists. An additional synoptic was developed to provide the flight crew with information about the effects of loss of flight critical data. Data was collected via questionnaires administered at the completion of flight scenarios, audio/video recordings, flight data, head and eye tracking data, pilot control inputs, and researcher observations. This paper presents findings derived from the questionnaire responses and subjective data measures including workload, situation awareness, usability, and acceptability as well as analyses of two low-energy flight events that resulted in near-stall conditions.

Kramer, Lynda J.↗

TPSAS-NF1676L-15194-DND

Technical Motivation - 1950s: Indication of large lateral (roll/yaw) acceleration (“β-dot”) dynamic derivatives for configurations with strong vortex flows in the stall region (Lichtenstein, Campbell, Riley)! - 1960s: Increased emphasis on use of long-range missiles tempered by aircraft losses in close-in air combat - 1970s: - Effect of lateral acceleration derivatives on aircraft stability (Nguyen) - Characteristics and air combat advantages of rapid controlled large-amplitude maneuvering at low speeds near maximum lift shown in piloted simulations (Herbst) - 1980s: - Dynamic (forced-oscillation, rotary balance, curved- and rolling-flow) wind tunnel tests (Grafton, Lutze, Hultberg) - Incorporation of test data into computer simulations (Kalviste) - Technologies developed for controlled maneuvers at stall, post-stall angles of attack - Concern that conventional math modeling inadequately represented the dynamic component of these motions - Need to evaluate dependency of control laws on accurate computer simulations and motion prediction

Marilyn E Ogburn↗

Exploring Airfoil Table Generation using XFOIL and OVERFLOW

The rotorcraft design process is a continuously evolving field of research that incorporates a number of software programs. An accurate airfoil table is critical in the design and testing process for rotorcraft. With multiple flow solvers available and flow conditions of multirotor UAM vehicles potentially covering a wide range of Reynolds and Mach numbers, a documented approach for developing airfoil tables is needed. Using benchmark data from legacy airfoil tables and wind tunnel tests for comparison, simulations for a comprehensive test matrix could guide rotorcraft design engineers in generating their own airfoil tables using the XFOIL and OVERFLOW solvers. The motivation for this study is to investigate flow solver features to develop a best practices document for airfoil table generation. The study uses the OVERFLOW and XFOIL flow solvers, coupled with the airfoil table generator AFTGen, to analyze three airfoils for a specific Reynolds numbers flow regime and provide details on how well each flow solver performs within a specific angle of attack range, Mach number range, Reynolds number range, and in different flow conditions, such as turbulent and transitional flow. OVERFLOW analyses in AFTGen for fully turbulent and transition flow are compared with XFOIL results and experimental test data for the section lift, section drag, and pressure coefficients. XFOIL ultimately yields results that are accurate within the linear angle of attack range and below a Mach number of 0.4 but tends to overpredict lift and underpredict drag unless the flow is in the compressible regime. XFOIL cannot accurately model stall and post-stall conditions due to the nature of the solver. This is evident in nearly every case run with XFOIL, where the linear range is usually predicted acceptably and the lift coefficient is overpredicted as the stall angle of attack is approached (with the exception being the generally poor correlation with most of the SSC-A09 cases). OVERFLOW is limited at low Mach numbers, and appears to perform best at Mach numbers of 0.4 and above. The exploration of airfoil table generation using XFOIL and OVERFLOW yielded moderately successful results for the NACA 0012 airfoil, reasonably good results for the RC(4)-10 airfoil, and less accurate results for the SSC-A09 airfoil.

Airfoil Table Generation↗

Space Suit Portable Life Support System Thermal Control Valve Ball Design

A Thermal Control Valve (TCV) has been in development for the Exploration Extravehicular Mobility Unit Portable Life Support System (xEMU PLSS). The xEMU PLSS TCV controls flow going to the liquid cooling and ventilation garment that the crew member wears during extra-vehicular activity to expel waste heat. A pervious TCV version with a linear actuator and diverter valve has been tested extensively to attempt to control the flow accurately. The previous TCV diverter valve has a non-linear flow response relative to valve position and has struggled to accurately meet the setpoints desired for precision thermal control. While many diverter valve design variations have been attempted, previous designs have all had difficulty in meeting set points. Additionally, high precision machining is required for these diverter valves to create a metal-on-metal seal which has its own drawbacks and doesn’t always meet requirements for internal leakage. This metal compression seal also requires stalling the linear actuator to load the seal in compression or tension which has demonstrated valve sticking failures when stalled. The xEMU PLSS TCV implements a new approach and design for a TCV which uses a rotational ball to control flow and has demonstrated a much more precise and linear flow control. The design functions like a two-way ball valve with two Teflon seats that cradle and compress the ball for sealing. A new geometric design modification to the ball outlet can create a set-able orifice like hole which is more predictable at controlling flow than using an annulus with the previous diverter valve. Additionally, the Teflon seat performs much better for preventing internal leakage than the metal seal and prevents sticking by having a large range in which it is sealed without having to stall the actuator. This paper will review a new proposed xEMU PLSS TCV ball design and compare it with previous iterations of the design.

Ryan Ogilvie↗

Comparison of Aerodynamic Analysis Tools Applied to a Propeller-Blown Wing

This paper describes initial results from an ongoing activity comparing two aerodynamic analysis tools: OVERFLOW, a Navier-Stokes flow solver, and FlightStream, a viscous surface-vorticity, unstructured panel method flow solver. Both tools are applied to analyses of an unblown wing and a propeller-blown wing, and then comparisons are performed between the predicted aerodynamic loads and moments from each tool. Computational performance and efficiencies of each tool and their usability in conceptual and preliminary air vehicle design are also discussed. A description of the workflow, underlying theoretical foundations, and best practices are provided. In comparing FlightStream and OVERFLOW, reasonable agreement between predicted performance is observed for flow regimes of interest at high angle of attack prior to stall, including blown wing aero-propulsive effects on lift augmentation and stall delay. In the post-stall regions, FlightStream appears to underestimate the effects of turbulent flow separation that contribute heavily to drag. However, as expected for a high-fidelity, time-accurate solver, the setup and computation time are substantially greater for OVERFLOW than for FlightStream.

Vivek Ahuja↗

Comparison of Aerodynamic Analysis Tools Applied to a Propeller-Blown Wing

This paper describes initial results from an ongoing activity comparing two aerodynamic analysis tools: OVERFLOW, a Navier-Stokes flow solver, and FlightStream, a viscous surface-vorticity, unstructured panel method flow solver. Both tools are applied to analyses of an unblown wing and a propeller-blown wing, and then comparisons are performed between the predicted aerodynamic loads and moments from each tool. Computational performance and efficiencies of each tool and their usability in conceptual and preliminary air vehicle design are also discussed. A description of the workflow, underlying theoretical foundations, and best practices are provided. In comparing FlightStream and OVERFLOW, reasonable agreement between predicted performance is observed for flow regimes of interest at high angle of attack prior to stall, including blown wing aero-propulsive effects on lift augmentation and stall delay. In the post-stall regions, FlightStream appears to underestimate the effects of turbulent flow separation that contribute heavily to drag. However, as expected for a high-fidelity, time-accurate solver, the setup and computation time are substantially greater for OVERFLOW than for FlightStream.

Vivek Ahuja↗

Space Suit Portable Life Support System Thermal Control Valve Ball Design

A Thermal Control Valve (TCV) has been in development for the Exploration Extravehicular Mobility Unit Portable Life Support System (xEMU PLSS). The xEMU PLSS TCV controls flow going to the liquid cooling and ventilation garment that the crew member wears during extra-vehicular activity to expel waste heat. A previous TCV version with a linear actuator and diverter valve has been tested to attempt to control the flow accurately. The previous valve has a non-linear flow response relative to valve position and has struggled to meet the setpoints desired for precise thermal control. While many diverter valve design variations have been attempted, all previous designs have had difficulty meeting set points. Additionally, high precision machining is required to create a metal-on-metal seal which has its own drawbacks and does not always meet requirements for internal leakage. This metal seal also requires stalling a linear actuator to load the seal in compression or tension which has caused sticking failures when stalled. A new approach and design for a TCV has been developed which uses a rotational ball to control flow and has demonstrated a much more precise and linear flow control. The design functions like a two-way ball valve with two Teflon seats that cradle and compress the ball for sealing. The ball outlet has a unique geometric design to create a set-able orifice like hole which is more predictable at controlling flow. Additionally, the Teflon seat performs much better for preventing internal leakage than the metal seal and prevents sticking by having a large range in which it is sealed without having to stall the actuator. This paper will review a new proposed xEMU PLSS TCV ball design and compare it with previous iterations of the design.

Ryan Ogilvie↗

Space Suit Portable Life Support System Thermal Control Valve Ball Design

A Thermal Control Valve (TCV) has been in development for the Exploration Extravehicular Mobility Unit Portable Life Support System (xEMU PLSS). The xEMU PLSS TCV controls flow going to the liquid cooling and ventilation garment that the crew member wears during extra-vehicular activity to expel waste heat. A previous TCV version with a linear actuator and diverter valve has been tested to attempt to control the flow accurately. The previous valve has a non-linear flow response relative to valve position and has struggled to meet the setpoints desired for precise thermal control. While many diverter valve design variations have been attempted, all previous designs have had difficulty meeting set points. Additionally, high precision machining is required to create a metal-on-metal seal which has its own drawbacks and does not always meet requirements for internal leakage. This metal seal also requires stalling a linear actuator to load the seal in compression or tension which has caused sticking failures when stalled. A new approach and design for a TCV has been developed which uses a rotational ball to control flow and has demonstrated a much more precise and linear flow control. The design functions like a two-way ball valve with two Teflon seats that cradle and compress the ball for sealing. The ball outlet has a unique geometric design to create a set-able orifice like hole which is more predictable at controlling flow. Additionally, the Teflon seat performs much better for preventing internal leakage than the metal seal and prevents sticking by having a large range in which it is sealed without having to stall the actuator. This paper will review a new proposed xEMU PLSS TCV ball design and compare it with previous iterations of the design.

Ryan Ogilvie↗

Tail-Cone Thruster Fan Rotor Flutter Analysis

The aeroelastic stability of a tail cone thruster fan was analyzed for three structural modes and various nodal diameter patterns. Computational fluid dynamics modeling with blade vibrations was used in the analyses performed at design (peak-efficiency) and two near-stall conditions at the design rotational speed. Aerodynamic damping was used to assess flutter since this integrally bladed rotor design will have minimal structural damping. Aerodynamic damping was found to be low at the design condition. For the first mode, aerodynamic damping was seen to decrease towards stall, vanishing for a zero nodal diameter pattern. Further decrease in mass flow led to negative aerodynamic damping (flutter) for the first and second nodal diameters in the near stall condition. The flowfield at this lowest mass flow rate exhibited some additional unsteadiness at higher frequency. The sensitivity of results to time step and amplitudes of vibration was examined and found to be very satisfactory. The largest uncertainty in the results comes from the observed sensitivity of the aerodynamic damping to details of the variation of grid deformations in the blade passage mesh from the blade passage to the boundaries. For the parametric variations analyzed, the calculated aerodynamic damping is lower if the grid deformations near the blade surface are higher. Further work is needed to understand the cause of this sensitivity and find possible solutions to reduce the effects on flutter predictions.

Fan↗

Dynamic voltage and frequency scaling based on memory channel slack

A processing system scales power to memory and memory channels based on identifying causes of stalls of threads of a wavefront. If the cause is other than an outstanding memory request, the processing system throttles power to the memory to save power. If the stall is due to memory stalls for a subset of the memory channels servicing memory access requests for threads of a wavefront, the processing system adjusts power of the memory channels servicing memory access request for the wavefront based on the subset. By boosting power to the subset of channels, the processing system enables the wavefront to complete processing more quickly, resulting in increased processing speed. Conversely, by throttling power to the remainder of channels, the processing system saves power without affecting processing speed.

Das, Shomit N.↗

High-Fidelity Simulation Aerodynamics Dataset of NACA 0012 and 0021 Airfoils

The repository contains time series data of pressure, viscous and moment forces for the NACA 0012 and 0021 airfoils at angles of attack (AOA), 5, 17, 30, 45, 60 and 90 degrees. The data was generated during the high-fidelity simulations of the airfoils using the open-source CFD code, Nalu-Wind (https://github.com/Exawind/nalu-wind). The research objective was to study the effects of mesh resolution and turbulence model on the three-dimensional deep stall aerodynamics of the airfoils, which has been published in the Journal of Turbulence (https://doi.org/10.1080/14685248.2023.2225141). Several meshes of the O-grid type were generated using the modified Pointwise Glyph script of Carrigan (https://github.com/pointwise/AirfoilMesh) by varying the wall normal and spanwise resolutions. Note that, the geometry was extruded by four chord lengths in the spanwise direction. In the paper, we showed that Improved Delayed Detached Eddy Simulation (IDDES) hybrid RANS/LES turbulence model with a minimum of 24 cells per chord length in the spanwise direction is necessary to correctly predict the loads in the deep stall regime. Under the NACA 0012 airfoil directory, the data for several combinations of wall-normal and spanwise resolutions are presented in each of the AOA subdirectories. The corresponding experimental data for the lift and drag polars can be found in the "exp_data" subdirectory. The directory for the NACA 0021 airfoil consists of CFD force data and airfoil polars for Reynolds numbers 2.7e5 and 2.0e6.

17 WIND ENERGY↗