Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SIGNAL NOISE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 793 records · Page 44

GREAT3 results - I. Systematic errors in shear estimation and the impact of real galaxy morphology

The study present first results from the third GRavitational lEnsing Accuracy Testing (GREAT3) challenge, the third in a sequence of challenges for testing methods of inferring weak gravitational lensing shear distortions from simulated galaxy images. GREAT3 was divided into experiments to test three specific questions, and included simulated space- and ground-based data with constant or cosmologically varying shear fields. The simplest (control) experiment included parametric galaxies with a realistic distribution of signal-to-noise, size, and ellipticity, and a complex point spread function (PSF). The other experiments tested the additional impact of realistic galaxy morphology, multiple exposure imaging, and the uncertainty about a spatially varying PSF; the last two questions will be explored in Paper II. The 24 participating teams competed to estimate lensing shears to within systematic error tolerances for upcoming Stage-IV dark energy surveys, making 1525 submissions overall. GREAT3 saw considerable variety and innovation in the types of methods applied. Several teams now meet or exceed the targets in many of the tests conducted (to within the statistical errors). We conclude that the presence of realistic galaxy morphology in simulations changes shear calibration biases by ~1 per cent for a wide range of methods. Other effects such as truncation biases due to finite galaxy postage stamps, and the impact of galaxy type as measured by the Sérsic index, are quantified for the first time. Our results generalize previous studies regarding sensitivities to galaxy size and signal-to-noise, and to PSF properties such as seeing and defocus. Almost all methods’ results support the simple model in which additive shear biases depend linearly on PSF ellipticity.

79 ASTRONOMY AND ASTROPHYSICS↗

Image registration error variance as a measure of overlay quality

When one image (the signal) is to be registered with a second image (the signal plus noise) of the same scene, one would like to know the accuracy possible for this registration. This paper derives an estimate of the variance of the registration error that can be expected via two approaches. The solution in each instance is found to be a function of the effective bandwidth of the signal and the noise, and the signal-to-noise ratio. Application of these results to LANDSAT-1 data indicates that for most cases, registration variances will be significantly less than the diameter of one picture element.

Mcgillem, C. D.↗

Design of RUSL Irradiation Experiment with Free Standing Sample

During FY19, the MIMIC-RUSL TREAT test successfully measured the shift in resonance of a cantilever beam as it underwent a grain restructuring event in the TREAT reactor core. FY20 efforts focused on a new capsule design which would replace the cantilever beam with a free-free beam. The free-free beam configuration eliminates the cantilever boundary condition and enables internal friction measurements. A test capsule was designed which supported the sample beam at the nodal points of the first flexural vibration mode. Initial tests detected the resonance peak but the signal to noise level was not high enough for in-situ measurements. Several detection probes were tested and a significant increase in the signal to noise was achieved. Although adequate signals and clean resonance peaks were measured when the beam was centered, the beam did not self-center when displaced resulting in distorted and inconsistent resonance peaks. It was concluded that the free-free beam approach is likely not suited for in-situ measurements. Measurement of ZGV plate waves is another option for in-situ microstructure monitoring and should be considered for future work.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Space Telescope and Optical Reverberation Mapping Project. VII. Understanding the Ultraviolet Anomaly in NGC 5548 with X-Ray Spectroscopy

During the Space Telescope and Optical Reverberation Mapping Project observations of NGC 5548, the continuum and emission-line variability became decorrelated during the second half of the six-month-long observing campaign. Here we present Swift and Chandra X-ray spectra of NGC 5548 obtained as part of the campaign. The Swift spectra show that excess flux (relative to a power-law continuum) in the soft X-ray band appears before the start of the anomalous emission-line behavior, peaks during the period of the anomaly, and then declines. This is a model-independent result suggesting that the soft excess is related to the anomaly. We divide the Swift data into on- and off-anomaly spectra to characterize the soft excess via spectral fitting. The cause of the spectral differences is likely due to a change in the intrinsic spectrum rather than to variable obscuration or partial covering. The Chandra spectra have lower signal-to-noise ratios, but are consistent with the Swift data. Our preferred model of the soft excess is emission from an optically thick, warm Comptonizing corona, the effective optical depth of which increases during the anomaly. This model simultaneously explains all three observations: the UV emission-line flux decrease, the soft-excess increase, and the emission-line anomaly.

79 ASTRONOMY AND ASTROPHYSICS↗

High Statistics Analysis using Anisotropic Clover Lattices: (I) Single Hadron Correlation Functions

We present the results of high-statistics calculations of correlation functions generated with single-baryon interpolating operators on an ensemble of dynamical anisotropic gauge-field configurations generated by the Hadron Spectrum Collaboration using a tadpole-improved clover fermion action and Symanzik-improved gauge action. A total of 292,500 sets of measurements are made using 1194 gauge configurations of size 20^3 x 128 with an anisotropy parameter \xi= b_s/b_t = 3.5, a spatial lattice spacing of b_s=0.1227\pm 0.0008 fm, and pion mass of m_\pi ~ 390 MeV. Ground state baryon masses are extracted with fully quantified uncertainties that are at or below the ~0.2%-level in lattice units. The lowest-lying negative-parity states are also extracted albeit with a somewhat lower level of precision. In the case of the nucleon, this negative-parity state is above the N\pi threshold and, therefore, the isospin-1/2 \pi N s-wave scattering phase-shift can be extracted using Luescher's method. The disconnected contributions to this process are included indirectly in the gauge-field configurations and do not require additional calculations. The signal-to-noise ratio in the various correlation functions is explored and is found to degrade exponentially faster than naive expectations on many time-slices. This is due to backward propagating states arising from the anti-periodic boundary conditions imposed on the quark-propagators in the time-direction. We explore how best to distribute computational resources between configuration generation and propagator measurements in order to optimize the extraction of single baryon observables.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A Micromegas-based low-background x-ray detector coupled to a slumped-glass telescope for axion research

Here, we report on the design, construction and operation of a low background x-ray detection line composed of a shielded Micromegas detector of the microbulk technology. The detector is made from radiopure materials and is placed at the focal point of a ~ 5 cm diameter, 1.5 m focal-length, cone-approximation Wolter I x-ray telescope (XRT) assembled from thermally-formed (or "slumped") glass substrates deposited with multilayer coatings. The system has been conceived as a technological pathfinder for the future International Axion Observatory (IAXO), as it combines two of the techniques (optic and detector) proposed in the conceptual design of the project. It is innovative for two reasons: it is the first time an x-ray optic has been designed and fabricated specifically for axion research, and the first time a Micromegas detector has been operated with an x-ray optic. The line has been installed at one end of the CERN Axion Solar Telescope (CAST) magnet and is currently looking for solar axions. Furthermore, the combination of the XRT and Micromegas detector provides the best signal-to-noise ratio obtained so far by any detection system of the CAST experiment with a background rate of 5.4×10 –3 counts per hour in the energy region-of-interest and signal spot area.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Dynamic programming based time-delay estimation technique for analysis of time-varying time-delay

A new time-delay estimation (TDE) technique based on dynamic programming is developed to measure the time-varying time-delay between two signals. The dynamic programming based TDE technique provides a frequency response five to ten times better than previously known TDE techniques, namely, those based on time-lag cross-correlation or wavelet analysis. Effects of frequency spectrum, signal-to-noise ratio, and amplitude of time-delay on response of the TDE technique (represented as transfer function) are studied using simulated data signals. The transfer function for the technique decreases with increase in noise in signal; however it is independent of signal spectrum shape. The dynamic programming based TDE technique is applied to the beam emission spectroscopy diagnostic data to measure poloidal velocity fluctuations, which led to the observation of theoretically predicted zonal flows in high-temperature tokamak plasmas.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Capacity of Pulse-Position Modulation (PPM) on Gaussian and Webb Channels

This article computes the capacity of various idealized soft-decision channels modeling an optical channel using an avalanche photodiode detector (APD) and pulse-position modulation (PPM). The capacity of this optical channel depends in a complicated way on the physical parameters of the APD and the constraints imposed by the PPM orthogonal signaling set. This article attempts to identify and separate the effects of several fundamental parameters on the capacity of the APD-detected optical PPM channel. First, an overall signal-to-noise ratio (SNR) parameter is de ned such that the capacity as a function of a bit-normalized version of this SNR drops precipitously toward zero at quasi-brick-wall limits on bit SNR that are numerically the same as the well-understood brick-wall limits for the standard additive white Gaussian noise (AWGN) channel. A second parameter is used to quantify the effects on capacity of one unique facet of the optical PPM channel (as compared with the standard AWGN channel) that causes the noise variance to be higher in signal slots than in nonsignal slots. This nonuniform noise variance yields interesting capacity effects even when the channel model is AWGN. A third parameter is used to measure the effects on capacity of the difference between an AWGN model and a non-Gaussian model proposed by Webb (see reference in [2]) for approximating the statistics of the APD-detected optical channel. Finally, a fourth parameter is used to quantify the blending of a Webb model with a pure AWGN model to account for thermal noise. Numerical results show that the capacity of M-ary orthogonal signaling on the Webb channel exhibits the same brick-wall Shannon limit, (M ln 2)=(M 1), as on the AWGN channel ( 1:59 dB for large M). Results also compare the capacity obtained by hard- and soft-output channels and indicate that soft-output channels o er a 3-dB advantage.

Dolinar, S.↗

A semiempirical linear model of indirect, flat-panel x-ray detectors

Purpose: It is important to understand signal and noise transfer in the indirect, flat-panel x-ray detector when developing and optimizing imaging systems. For optimization where simulating images is necessary, this study introduces a semiempirical model to simulate projection images with user-defined x-ray fluence interaction. Methods: The signal and noise transfer in the indirect, flat-panel x-ray detectors is characterized by statistics consistent with energy-integration of x-ray photons. For an incident x-ray spectrum, x-ray photons are attenuated and absorbed in the x-ray scintillator to produce light photons, which are coupled to photodiodes for signal readout. The signal mean and variance are linearly related to the energy-integrated x-ray spectrum by empirically determined factors. With the known first- and second-order statistics, images can be simulated by incorporating multipixel signal statistics and the modulation transfer function of the imaging system. To estimate the semiempirical input to this model, 500 projection images (using an indirect, flat-panel x-ray detector in the breast CT system) were acquired with 50-100 kilovolt (kV) x-ray spectra filtered with 0.1-mm tin (Sn), 0.2-mm copper (Cu), 1.5-mm aluminum (Al), or 0.05-mm silver (Ag). The signal mean and variance of each detector element and the noise power spectra (NPS) were calculated and incorporated into this model for accuracy. Additionally, the modulation transfer function of the detector system was physically measured and incorporated in the image simulation steps. For validation purposes, simulated and measured projection images of air scans were compared using 40 kV/0.1-mm Sn, 65 kV/0.2-mm Cu, 85 kV/1.5-mm Al, and 95 kV/0.05-mm Ag. Results: The linear relationship between the measured signal statistics and the energy-integrated x-ray spectrum was confirmed and incorporated into the model. The signal mean and variance factors were linearly related to kV for each filter material (r{sup 2} of signal mean to kV: 0.91, 0.93, 0.86, and 0.99 for 0.1-mm Sn, 0.2-mm Cu, 1.5-mm Al, and 0.05-mm Ag, respectively; r{sup 2} of signal variance to kV: 0.99 for all four filters). The comparison of the signal and noise (mean, variance, and NPS) between the simulated and measured air scan images suggested that this model was reasonable in predicting accurate signal statistics of air scan images using absolute percent error. Overall, the model was found to be accurate in estimating signal statistics and spatial correlation between the detector elements of the images acquired with indirect, flat-panel x-ray detectors. Conclusions: The semiempirical linear model of the indirect, flat-panel x-ray detectors was described and validated with images of air scans. The model was found to be a useful tool in understanding the signal and noise transfer within indirect, flat-panel x-ray detector systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Inversion of data from diffraction-limited multiwavelength remote sensors. I - Linear case

The remote sensing inverse problem is considered in which the sensor does not necessarily view the same area on the earth at each wavelength, and spatial correlations of the geophysical parameters may be present. Under the conditions of linearity and stationary statistics, the minimum mean-square error solution to the problem of inverting such data is a spatial filter of the Wiener-Kolmogorov class. The resulting remote-sensing system can be characterized by an impulse response matrix in ordinary space or by a transfer matrix in frequency space. A signal-to-noise matrix for the geophysical parameters to be sensed is also defined; this matrix depends on the postulated a priori statistics and on the characteristics of the remote-sensing instrument. The system transfer matrix and the signal-to-noise matrix are simultaneously diagonalizable. The optimum transfer matrix filters out of the estimate vector those eigenparameters for which eigenvalues of the signal-to-noise matrix are less than unity.

Rosenkranz, P. W.↗

End-to-End Models for Effects of System Noise on LIMS Analysis of Igneous Rocks

The ChemCam instrument on the Mars Science Laboratory will be the first extraterrestial deployment of laser-induced breakdown spectroscopy (UBS) for remote geochemical analysis. LIBS instruments are also being proposed for future NASA missions. In quantitative LIBS applications using multivariate analysis techniques, it is essential to understand the effects of key instrument parameters and their variability on the elemental predictions. Baseline experiments were run on a laboratory instrument in conditions reproducing ChemCam performance on Mars. These experiments employed Nd:YAG laser producing 17 mJ/pulse on target and an with a 200 {micro}m FWHM spot size on the surface of a sample. The emission is collected by a telescope, imaged on a fiber optic and then interfaced to a demultiplexer capable of >40% transmission into each spectrometer. We report here on an integrated end-to-end system performance model that simulates the effects of output signal degradation that might result from the input signal chain and the impact on multivariate model predictions. There are two approaches to modifying signal to noise (SNR): degrade the signal and/or increase the noise. Ishibashi used a much smaller data set to show that the addition of noise had significant impact while degradation of spectral resolution had much less impact on accuracy and precision. Here, we specifically focus on aspects of remote LIBS instrument performance as they relate to various types of signal degradation. To assess the sensitivity of LIBS analysis to signal-to-noise ratio (SNR) and spectral resolution, the signal in each spectrum from a suite of 50 laboratory spectra of igneous rocks was variably degraded by increasing the peak widths (simulating misalignment) and decreasing the spectral amplitude (simulating decreases in SNR).

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Soft x-ray spectrum unfold of K-edge filtered x-ray diode arrays using cubic splines

Cubic spline interpolation is able to recover temporally and spectrally resolved soft x-ray flux from an array of K-edge filtered x-ray diodes without the need for a priori assumptions about the spectrum or the geometry of the emitting volume. The mathematics of the cubic spline interpolation is discussed in detail. The analytic nature of the cubic spline solution allows for analytical error propagation, and the method of calculating the error for radiation temperature, spectral power, and confidence intervals of the unfolded spectrally resolved flux is explained. An unfold of a blackbody model demonstrates the accuracy of the cubic spline unfold. Tests of cubic spline performance using spectrally convolved detailed atomic model simulation results have been performed to measure the method's ability to conserve spectral power to within a factor of 2 or better in line-dominated regimes. The unfold is also demonstrated to work when information from the x-ray diode array is limited due to high signal-to-noise ratios or lack of signal due to over-attenuation or over-filtration of the x-ray diode signal. Here, the robustness of the unfold with respect to background subtraction and raw signal processing, signal alignment between diode traces, limited signal information, and initial conditions is discussed. Results from an example analysis of a halfraum drive are presented to demonstrate the capabilities of the unfold in comparison with previously established methods.

47 OTHER INSTRUMENTATION↗

Development of plasma bolometers using fiber-optic temperature sensors

Measurements of radiated power in magnetically confined plasmas are important for exhaust studies in present experiments and expected to be a critical diagnostic for future fusion reactors. Resistive bolometer sensors have long been utilized in tokamaks and helical devices but suffer from electromagnetic interference (EMI). Results are shown from initial testing of a new bolometer concept based on fiber-optic temperature sensor technology. A small, 80 μm diameter, 200 μm long silicon pillar attached to the end of a single mode fiber-optic cable acts as a Fabry–Pérot cavity when broadband light, λ{sub o} ∼ 1550 nm, is transmitted along the fiber. Changes in temperature alter the optical path length of the cavity primarily through the thermo-optic effect, resulting in a shift of fringes reflected from the pillar detected using an I-MON 512 OEM spectrometer. While initially designed for use in liquids, this sensor has ideal properties for use as a plasma bolometer: a time constant, in air, of ∼150 ms, strong absorption in the spectral range of plasma emission, immunity to local EMI, and the ability to measure changes in temperature remotely. Its compact design offers unique opportunities for integration into the vacuum environment in places unsuitable for a resistive bolometer. Using a variable focus 5 mW, 405 nm, modulating laser, the signal to noise ratio versus power density of various bolometer technologies are directly compared, estimating the noise equivalent power density (NEPD). Present tests show the fiber-optic bolometer to have NEPD of 5-10 W/m{sup 2} when compared to those of the resistive bolometer which can achieve <0.5 W/m{sup 2} in the laboratory, but this can degrade to 1-2 W/m{sup 2} or worse when installed on a tokamak. Concepts are discussed to improve the signal to noise ratio of this new fiber-optic bolometer by reducing the pillar height and adding thin metallic coatings, along with improving the spectral resolution of the interrogator.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Investigations of stochastic resonance in two-terminal device with vanadium dioxide film

The results of stochastic resonance investigation in a nonlinear system, consisting of a microstructure with a polycrystalline vanadium dioxide (VO{sub 2}) film grown on sapphire and resistor in series are reported. Nonlinearity of the system was provided due to insulator-metal phase transition in VO{sub 2}. In the stochastic resonance regime at 100 Hz signal frequency, the transition coefficient of signal-to-noise ratio reached 87 in contrast to 250 for microstructures with VO{sub 2} films grown on silica in our previous investigations. The measured characteristics of microstructures with VO{sub 2} films grown on silica and sapphire substrates were found to be qualitatively similar. For both substrates, a stochastic resonance was observed at threshold switching voltage from insulating to metallic state of VO{sub 2}. For sapphire substrate the output signal-to-noise ratio rose at higher signal frequencies. The stochastic resonance phenomenon in VO{sub 2} films is explained in terms of the monostable damped oscillator model.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Frequency-Domain Deconvolution for Flight Dynamics Applications

A deconvolution method is presented for estimating input data from measured output data and a model of the dynamic process involved. The method uses an optimal Wiener filter for separating the measured data into signal and noise components, and a high-accuracy Fourier transform for inverting the model dynamics in the frequency domain. The method is an extension of optimal Fourier smoothing, and uses a technique to enhance the contrast between the signal and noise spectra in designing the Wiener filter. The deconvolution method was applied to simulation and flight test data for the purposes of removing unwanted distortions introduced by signal-conditioning filters and sensor dynamics, and for reconstructing turbulence inputs from measured sensor data. Results indicated hat the method performs well given good signal-to-noise levels and accurate models of the dynamic process.

Grauer, Jared A.↗

Analysis of the optical design of the NSLS-II Coherent Hard X-ray beamline

Ultra-low emittance third-generation synchrotron radiation sources such as the NSLS-II offer excellent opportunities for the development of experimental techniques exploiting x-ray coherence. Coherent light scattered by a heterogeneous sample produces a speckle pattern characteristic for the specific arrangement of the scatterers. This may vary over time, and the resultant intensity fluctuations can be measured and analyzed to provide information about the sample dynamics. X-ray photon correlation spectroscopy (XPCS) extends the capability of dynamic light scattering to opaque and turbid samples and extends the measurements of time evolution to nanometer length scales. As a consequence XPCS became crucial in the study of dynamics in systems including, but not being limited to, colloids, polymers, complex fluids, surfaces and interfaces, phase ordering alloys, etc. In this paper we present the conceptual optical design and the theoretical performance of the Coherent Hard X-ray (CHX) beamline at NSLS-II, dedicated to XPCS and other coherent scattering techniques. For the optical design of this beamline, there is a tradeoff between the coherence needed to distinguish individual speckles and the phase acceptance (high intensity) required to measure fast dynamics with an adequate signal-to-noise level. As XPCS is a 'photon hungry' technique, the beamline optimization requires maximizing the signal-to-noise ratio of the measured intensity-intensity autocorrelation function. The degree of coherence, as measured by a two-slit (Young) experiment, is used to characterize the speckle pattern visibilities. The beamline optimization strategy consists of maximization of the on-sample intensity while keeping the degree of coherence within the 0.1-0.5 range. The resulted design deviates substantially from an ad-hoc modification of a hard x-ray beamline for XPCS measurements. The CHX beamline will permit studies of complex systems and measurements of bulk dynamics down to the microsecond time scales. In general, the 10-fold increase in brightness of the NSLS-II, compared to other sources, will allow for measurements of dynamics on time-scales that are two orders of magnitude faster than what is currently possible. We also conclude that the common approximations used in evaluating the transverse coherence length would not be sufficiently accurate for the calculation of the coherent properties of an undulator-based beamline, and a thorough beamline optimization at a low-emittance source such as the NSLS-II requires a realistic wave-front propagation analysis.

36 MATERIALS SCIENCE↗

SDSS-IV MaStar: [α/Fe] for the MaNGA Stellar Library from synthetic model spectra

ABSTRACT We calculate the α-enhancement ratio [α/Fe] for the Mapping Nearby Galaxies at APO (MaNGA) Stellar Library (MaStar) while also fitting for the fundamental atmospheric parameters effective temperature, surface gravity, and metallicity – Teff, log g, [Fe/H]. This approach builds upon a previous catalogue of stellar parameters, whereby only the fundamental atmospheric parameters are fit with solar-scaled models. Here, we use the same Markov Chain Monte Carlo method with the additional free parameter [α/Fe]. Using the full spectral fitting code pPXF, we are able to fit multiple lines sensitive to [α/Fe] for a more robust measurement. Quality flags based on the convergence of the sampler, errors in [α/Fe] and a cut in the χ2 of the model fit are used to clean the final catalogue, returning 17 214 spectra and values in the range of −0.25 < [α/Fe] < 0.48. Comparing our calculated [α/Fe] with literature values reveals a degeneracy in cool stars with log g ≥ ∼4; this comparison is then used to create an alternative and calibrated parameter set. We also plot the final catalogue in an [Fe/H] versus [α/Fe] diagram and recover the expected result of increasing [α/Fe] with decreasing [Fe/H] for Milky Way disc-halo stars. We apply our method to a subsample of spectra of uniform resolution and higher signal to noise that finds that our results are independent of this higher signal to noise. In the context of stellar population models, we are able to cover a parameter space for the creation of intermediate to old age models at solar-scaled [α/Fe], high [Fe/H] and enhanced [α/Fe], low [Fe/H].

79 ASTRONOMY AND ASTROPHYSICS↗

Signal processing of jet noise from flyover test data

Narrow-band spectra characterizing jet noise are constructed from flyover acoustic measurements. Radar and c-band tracking systems provided the aircraft position histories which enabled directivity and smear angles from the aircraft to each microphone to be computed. These angles are based on source emission time and thus give some idea about the directivity of the radiated sound field due to jet noise. Simulated spectra are included in the paper to demonstrate spectral broadening due to smear angle. The acoustic data described in the study has application to community noise analysis, noise source characterization and validation of prediction models. Both broadband-shock noise and turbulent mixing noise are observed in the spectra. A detailed description of the signal processing procedures is provided.

Kelly, Jeffrey J.↗