Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SHUNT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 793 records · Page 44

The test facility requirements for the thermal vacuum thermal balance test of the Cosmic Background Explorer Observatory

The Cosmic Background Explorer Observatory (COBE) underwent a thermal vacuum thermal balance test in the Space Environment Simulator (SES). This was the largest and most complex test ever conducted at this facility. The 4 x 4 m (13 x 13 ft) spacecraft weighed approx. 2223 kg (4900 lbs) for the test. The test set up included simulator panels for the inboard solar array panels, simulator panels for the flight cowlings, Sun and Earth Sensor stimuli, Thermal Radio Frequency Shield heater stimuli and a cryopanel for thermal control in the Attitude Control System Shunt Dissipator area. The fixturing also included a unique 4.3 m (14 ft) diameter Gaseous Helium Cryopanel which provided a 20 K environment for the calibration of one of the spacecraft's instruments, the Differential Microwave Radiometer. This cryogenic panel caused extra contamination concerns and a special method was developed and written into the test procedure to prevent the high buildup of condensibles on the panel which could have led to backstreaming of the thermal vacuum chamber. The test was completed with a high quality simulated space environment provided to the spacecraft. The test requirements, test set up, and special fixturing are described.

Milam, Laura J.↗

Development and testing of a source subsystem for the supporting development PMAD DC test bed

The supporting Development Power Management and Distribution (PMAD) DC Test Bed is described. Its benefits to the Space Station Freedom Electrical Power System design are discussed along with a short description of how the PMAD DC Test Bed was systematically integrated. The Source Subsystem of the PMAD DC Test Bed consisting of a Sequential Shunt Unit (SSU) and a Battery Charge/Discharge Unit (BCDU) is introduced. The SSU is described in detail and component level test data is presented. Next, the BCDU's operation and design is given along with component level test data. The Source Subsystem is then presented and early data given to demonstrate an effective subsystem design.

Button, Robert M.↗

Rivers in the sea - Can we quantify pigments in the Amazon and the Orinoco River plumes from space?

Coastal Zone Color Scanner (CZCS) images of the western tropical Atlantic (1979-1982) were combined into monthly mean surface pigment fields. These suggest that Amazon River water flows along northeastern South America directly toward the Caribbean sea early in the year. After June, however, the North Brazil Current is shunted eastward, carrying a large fraction of Amazon water into the North Equatorial Countercurrent (NECC). This eastward flow causes diminished flow through the Caribbean, which permits northwestward dispersal of Orinoco River water due to local Ekman forcing. The Orinoco plume crosses the Caribbean, leading to seasonal variation in surface salinity near Puerto Rico. At least 50 percent of the pigment concentration estimated in these plumes seems due to viable phytoplankton.

Muller-Karger, Frank E.↗

Simulation and dynamic performance of a 20-kHz spacecraft power system

A candidate 20-kHz spacecraft power system which includes a series-parallel combination of four Mapham inverters connected to several types of loads is described. A computer simulation of the power system is used to illustrate its steady-state and dynamic performance on an end-to-end basis. Comparisons with measured data are made. It is shown that significant distortion of the 20-kHz bus voltage can occur due to the switching of the load converters. This distortion can be reduced by including a shunt-connected parallel resonant filter on the 20-kHz side of the load converter. It is also shown that the distortion can be reduced by using a pulse-density-modulated switching strategy.

Wasynczuk, O.↗

Test facility requirements for the thermal vacuum thermal balance test of the Cosmic Background Explorer Observatory

The Cosmic Background Explorer Observatory (COBE) underwant a thermal vacuum thermal balance test in the Space Environment Simulator (SES). This was the largest and most complex test ever conducted at this facility. The 4 x 4 m (13 x 13 ft) spacecraft weighed approx. 2223 kg (4900 lbs) for the test. The test set up included simulator panels for the inboard solar array panels, simulator panels for the flight cowlings, Sun and Earth Sensor stimuli, Thermal Radio Frequency Shield heater stimuli and a cryopanel for thermal control in the Attitude Control System Shunt Dissipator area. The fixturing also included a unique 4.3 m (14 ft) diameter Gaseous Helium Cryopanel which provided a 20 K environment for the calibration of one of the spacecraft's instruments, the Differential Microwave Radiometer. This cryogenic panel caused extra contamination concerns and a special method was developed and written into the test procedure to prevent the high buildup of condensibles on the panel which could have led to backstreaming of the thermal vacuum chamber. The test was completed with a high quality simulated space environment provided to the spacecraft. The test requirements, test set up, and special fixturing are described.

Milam, Laura J.↗

Galileo spacecraft power management and distribution system

The Galileo PMAD (power management and distribution system) is described, and the design drivers that established the final as-built hardware are discussed. The spacecraft is powered by two general-purpose heat-source-radioisotope thermoelectric generators. Power bus regulation is provided by a shunt regulator. Galileo PMAD distributes a 570-W beginning of mission (BOM) power source to a user complement of some 137 load elements. Extensive use of pyrotechnics requires two pyro switching subassemblies. They initiate 148 squibs which operate the 47 pyro devices on the spacecraft. Detection and correction of faults in the Galileo PMAD is an autonomous feature dictated by requirements for long life and reliability in the absence of ground-based support. Volatile computer memories in the spacecraft command and data system and attitude control system require a continuous source of backup power during all anticipated power bus fault scenarios. Power for the Jupiter Probe is conditioned, isolated, and controlled by a Probe interface subassembly. Flight performance of the spacecraft and the PMAD has been successful to date, with no major anomalies.

Detwiler, R. C.↗

Modeling and simulation of the space platform power system

A comprehensive computer-aided modeling and simulation technique for the space platform power system is described. Large-signal and small-signal modeling is presented for the system components. The component models have been integrated to form the complete power system model. The system model is shown to be a powerful tool in simulating the behavior of the system with variation of illumination level and load. It can be used to study the bus regulation in each mode and to observe mode changes as the solar array is subjected to transitions from sunlight to eclipse and back to sunlight. System simulations show how the bus regulation is maintained by activating the shunt switching unit, the charger, or the discharger, depending on the available illumination level. The system model is suitable for verifying hardware results of for analyzing the performance of a proposed system where hardware testing is not feasible. The EASY5 dynamic analysis program is used as the host software for the modeling and simulation.

Patil, A. R.↗

All high Tc edge-geometry weak links utilizing Y-Ba-Cu-O barrier layers

High quality YBa2Cu3O(7-x) normal-metal/YBa2Cu3O(7-x) edge-geometry weak links have been fabricated using nonsuperconducting Y-Ba-Cu-O barrier layers deposited by laser ablation at reduced growth temperatures. Devices incorporating 25-100 A thick barrier layers exhibit current-voltage characteristics consistent with the resistively shunted junction model, with strong microwave and magnetic field response at temperatures up to 85 K. The critical currents vary exponentially with barrier thickness, and the resistances scale linearly with Y-Ba-Cu-O interlayer thickness and device area, indicating good barrier uniformity, with an effective mormal metal coherence length of 20 A.

Hunt, B. D.↗

Improved Capacitive Liquid Sensor

Improved capacitive sensor used to detect presence and/or measure thickness of layer of liquid. Electrical impedance or admittance of sensor measured at prescribed frequency, and thickness of liquid inferred from predetermined theoretical or experimental relationship between impedance and thickness. Sensor is basically a three-terminal device. Features interdigitated driving and sensing electrodes and peripheral coplanar ground electrode that reduces parasitic effects. Patent-pending because first to utilize ground plane as "shunting" electrode. System less expensive than infrared, microwave, or refractive-index systems. Sensor successfully evaluated in commercial production plants to characterize emulsions, slurries, and solutions.

Waldman, Francis A.↗

The evolution of power management architecture for missions to the outer planets

Outer planet spacecraft have unique requirements that differentiate them from inner planet and Earth orbiter spacecraft. To meet these requirements, the Voyager and Galileo Power Management And Distribution (PMAD) architectures employed shunt regulation and carried on the Mariner tradition of AC power distribution to many of the user loads. Also, autonomous fault recovery was achieved by automatic responses in hardware and software recovery routines. Finally, power distribution switching was expanded to allow for removal of the most trivial load element as the nuclear source depleted itself. The design cycle has begun for a third generation spacecraft set named Comet Rendezvous Asteroid Flyby (CRAF) and Cassini (a saturn orbiter). In their power systems, AC power distribution, relay/fuse load switching, and fault protection will give way to the advantages of DC power and solid state load switches.

Detwiler, R. C.↗

Whiskerless Schottky diode

A Schottky diode for millimeter and submillimeter wave applications is comprised of a multi-layered structure including active layers of gallium arsenide on a semi-insulating gallium arsenide substrate with first and second insulating layers of silicon dioxide on the active layers of gallium arsenide. An ohmic contact pad lays on the silicon dioxide layers. An anode is formed in a window which is in and through the silicon dioxide layers. An elongated contact finger extends from the pad to the anode and a trench, preferably a transverse channel or trench of predetermined width, is formed in the active layers of the diode structure under the contact finger. The channel extends through the active layers to or substantially to the interface of the semi-insulating gallium arsenide substrate and the adjacent gallium arsenide layer which constitutes a buffer layer. Such a structure minimizes the effect of the major source of shunt capacitance by interrupting the current path between the conductive layers beneath the anode contact pad and the ohmic contact. Other embodiments of the diode may substitute various insulating or semi-insulating materials for the silicon dioxide, various semi-conductors for the active layers of gallium arsenide, and other materials for the substrate, which may be insulating or semi-insulating.

Bishop, William L.↗

Analysis of shielded CPW discontinuities with air-bridges

The effect of air-bridges on the performance of various coplanar waveguides (CPW) discontinuities is studied. Specifically, the coupled open-end CPW's and the short-end shunt CPW stub discontinuities are considered. The high frequency effect of the air-bridge is evaluated using a hybrid technique. At first, the frequency dependent equivalent circuit of the planar discontinuity without the air-bridge is derived using the Space Domain Integral Equation (SDIE) method. Then, the circuit is modified by incorporating the air-bridge's parasitic inductance and capacitance which are evaluated using a simple quasi-static model. The frequency response of each discontinuity with and without the air-bridge is studied and the scattering parameters are plotted in the frequency range 30-50 GHz for typical CPW dimensions.

Dib, N. I.↗

Ventilation-perfusion relationships in the lung during head-out water immersion

Mechanisms of altered pulmonary gas exchange during water immersion were studied in 12 normal males: 6 young (aged 20-29) and 6 older (aged 40-45). It is concluded that, in young subjects with closing volume (CV) less than expiratory reserve volume (ERV), gas exchange was enhanced during immersion, because normal ventilation-perfusion relations were preserved, and by mass balance, the ventilation/O2 uptake changes elevated arterial P(O2). In older males with CV greater than ERV and 52 percent of tidal volume below CV, immersion-induced airways closure during tidal breathing was associated with minimally increased shunt that did not significantly impair gas exchange. It is suggested that airways closure of this degree is of little importance to gas exchange.

Derion, Toniann↗

All-YBa2Cu3O(7-x) edge-geometry weak links

High quality YBa2Cu3O(7-x)/normal-metal/YBa2Cu3O(7-x) edge-geometry weak links are fabricated using nonsuperconducting Y-Ba-Cu-O barrier layers deposited by laser ablation at reduced growth temperatures. Devices incorporating 25-100-A-thick barrier layers exhibit current-voltage characteristics consistent with the resistively-shunted-junction model, as well as ac Josephson steps. Magnetic field modulation of the critical currents shows Fraunhofer-like behavior with a periodicity which scales with device area. The critical currents vary exponentially with barrier thickness indicating an effective normal metal coherence length of 20 A. The average resistances scale linearly with Y-Ba-Cu-O interlayer thickness and device area. The scaling behavior of the device parameters combined with the well-behaved magnetic field modulation of the critical currents demonstrates good barrier-layer uniformity with low pinhole densities. Near the transition temperature, the critical currents exhibit a temperature dependence proportional to (1 - T/Tc) squared.

Hunt, B. D.↗

Equatorial bubbles updrafting at supersonic speeds

Plasma and electric field observations from two satellite encounters with equatorial plasma bubbles updrafting at velocities of about 2 km/s are presented. These large, upward velocities are consistent with an adaptation of Chandrasekhar's model for the motion of plasma blobs supported against gravity by a magnetic field. Vector magnetic field measurements, available during one of the bubble encounters show a perturbation of about 150 nT, directed radially outward from the earth, near the western wall of deepest plasma depletion. This magnetic variation is too large to be caused by simple shunting of the g x B current along the bubble's edge. Rather, it is Alfvenic in nature, radiating from a generator located near the magnetic equator, in the plasma outside the bubble's leading edge. A heuristic model of a depleted flux tube with constant circular cross section moving upward through a background plasma predicts most of the measurements' qualitative features.

Aggson, Thomas L.↗

Multikilowatt power electronics development for spacecraft

Attention is given to several multikilowatt power electronic components developed by TRW for the Space Station Power Management and Distribution test bed at NASA Lewis Research Center. These components include a 12.5-kW DC-DC converter, a 6.25-kW battery charge/discharge regulator, an 82-channel sequential shunt unit, a 10-A remote power controllers, and three different types of 1-kW load converters. TRW is also monitoring the development of 120-V fuses for space applications. The authors discuss these developments and provide steady-state and dynamic performance parameters.

Decker, D. K.↗

Modeling of Space Station power system components and their interactions

The authors demonstrate that the functional modeling approach is feasible in modeling large-scale spacecraft power systems such as the Space Station electric power system (EPS). The functional models for the solar array sequential shunt unit and the battery charging/discharging unit are presented. The functional modeling approach has also been applied to simulate other major EPS components. The usefulness of this approach in system-level studies has been demonstrated by incorporating these models into a power system model and simulating the system behavior under various conditions. The simulation results are consistent with those obtained experimentally. With larger time step size and reduced model complexity, the computation time required by the functional modeling approach is short. Functional models are effective in simulation studies of system-level issues, especially for large-scale power systems including many power electronic components.

Tam, Kwa-Sur↗

Development and testing of a source subsystem for the supporting development PMAD DC test bed

The supporting Development Power Management and Distribution (PMAD) DC test bed is described. Its benefits to the Space Station Freedom Electrical Power System design are discussed along with a short description of how the PMAD DC test bed was systematically integrated. The source subsystem of the PMAD DC test bed, consisting of a Sequential Shunt Unit (SSU) and a Battery Charge/Discharge Unit (BCDU), is introduced. The SSU is described in detail and component-level test data is presented. Next, the BCDU's operation and design are given along with component-level test data. The Source Subsystem is then presented and early data given to demonstrate an effective subsystem design.

Button, Robert M.↗