Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SCaN”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 793 records · Page 44

Fast Scanning Diamond Detector for Electron Beam Profile Monitoring

The first prototype of a fast scanning diamond beam profile detector (DBPD) suitable for invasive high power CW electron beam core profile measurements in transmittance mode was developed. It consists of a multi-strip solid state diamond detector to scan with high speed (up to 1 m/s) and precision (about 5 μm) through the core of an electron beam. The diamond sensor was made from a thin polycrystalline diamond (PCD) plate with highly B-doped diamond conductive strips both grown by CVD. Transient currents from the multi-strip detector were measured with fast digitizing electrometers. Successful operation of the DBPD was demonstrated for pulsed (5 Hz) and CW (78 kHz) CeC beams, including the detector’s ability to withstand a 20 sec insertion into the CW CeC beam core. The X-Y beam spatial profile was measured in one scan. Thermal modelling demonstrated a manageable thermal impact even from a relatively long insertion of the diamond sensor into the CW CeC core and very short (0.2 s) insertion into the CW LEReC beam core. Electrical impedance modelling of the detector and vacuum chamber assembly demonstrated minimal impact on beam line impedance with diamond sensor insertion.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Application of Quad-Scan Measurement Techniques to Muon Beams in the Muon g-2 Experiment

Determination of the properties of a beam during transport is a vital process for most accelerator-related experiments; for example Fermilab's Muon g-2 experiment requires large numbers of muons to be stored in a storage ring of 7 meter radius, and the transmission fraction has been shown to depend strongly on the properties of the beam, specifically the Twiss parameters. The current equipment in the muon campus beamlines allows only measurement of beam profiles which limits how well propagation can be predicted, however by using the well-studied quad-scan technique it is possible to obtain all of the Twiss parameters at a point using these profiles. Experimental quad-scans of muon beams have not yet been reported, this paper introduces the quad-scan technique and then goes on to discuss the analysis of one such experiment and the results obtained, showing that such a technique is applicable in the muon g-2 experiment to obtain the Twiss parameters without requiring installation of new equipment.

43 PARTICLE ACCELERATORS↗

Analysis of Vernier Scans during RHIC Run-13 (pp at 255 GeV/beam)

At RHIC the collision rate per IP is measured by the Zero Degree Calorimeters (ZDC). Both, STAR and PHENIX, contain those detectors that are of identical design but are equipped with different Photo Multiplier Tubes (PMT) and operated with individually different HV setups and also slightly different read-out electronics. The collision rate, as measured by the ZDC, corresponds to the rate of mutual forward neutral particles above a variable threshold and within a certain coincidence window. Due to the differences in the detector electronics the two devices are calibrated individually every year by the use of vernier scans. During the RHIC polarized proton Run in 2013 a total of 6 vernier scans per experiment were performed. This note presents the data and summarizes the results, i.e. effective ZDC cross section and emittance measurements, from those scans.

43 PARTICLE ACCELERATORS↗

Sensitivity of Beam Parameters to a Station C Solenoid Scan on Axis II

Magnet scans are a standard technique for determining beam parameters in accelerators. Beam parameters are inferred from spot size measurements using a model of the beam optics. The sensitivity of the measured beam spot size to the beam parameters is investigated for typical DARHT Axis II beam energies and currents. In a typical S4 solenoid scan, the downstream transport is tuned to achieve a round beam at Station C with an envelope radius of about 1.5 cm with a very small divergence with S4 off. The typical beam energy and current are 16.0 MeV and 1.625 kA. Figures 1-3 show the sensitivity of the bean size at Station C to the emittance, initial radius and initial angle respectively. To better understand the relative sensitivity of the beam size to the emittance, initial radius and initial angle, linear regressions were performed for each parameter as a function of the S4 setting. The results are shown in Figure 4. The measured slope was scaled to have a maximum value of 1 in order to present the relative sensitivities in a single plot. Figure 4 clearly shows the beam size at the minimum of the S4 scan is most sensitive to emittance and relatively insensitive to initial radius and angle as expected. The beam emittance is also very sensitive to the beam size of the converging beam and becomes insensitive to the beam size of the diverging beam. Measurements of the beam size of the diverging beam provide the greatest sensitivity to the initial beam radius and to a lesser extent the initial beam angle. The converging beam size is initially very sensitive to the emittance and initial angle at low S4 currents. As the S4 current is increased the sensitivity to the emittance remains strong while the sensitivity to the initial angle diminishes.

43 PARTICLE ACCELERATORS↗

Nearest Neighbor Averaging and its Effect on the Critical Level and Minimum Detectable Concentration for Scanning Radiological Survey Instruments that Perform Facility Release Surveys.

Through the SNL New Mexico Small Business Assistance (NMSBA) program, several Sandia engineers worked with the Environmental Restoration Group (ERG) Inc. to verify and validate a novel algorithm used to determine the scanning Critical Level (L c ) and Minimum Detectable Concentration (MDC) (or Minimum Detectable Areal Activity) for the 102F scanning system. Through the use of Monte Carlo statistical simulations the algorithm mathematically demonstrates accuracy in determining the L c and MDC when a nearest-neighbor averaging (NNA) technique was used. To empirically validate this approach, SNL prepared several spiked sources and ran a test with the ERG 102F instrument on a bare concrete floor known to have no radiological contamination other than background naturally occurring radioactive material (NORM). The tests conclude that the NNA technique increases the sensitivity (decreases the L c and MDC) for high-density data maps that are obtained by scanning radiological survey instruments.

Fournier, Sean Donovan↗

Proceedings of RIKEN BNL Research Center Workshop: Theory and Modeling for the Beam Energy Scan: From Exploration to Discovery (Volume 121)

The Relativistic Heavy Ion Collider (RHIC) at Brookhaven National Laboratory has concluded phase I of its Beam Energy Scan (BES) program. The goal of the RHIC BES program is to explore the phase diagram of strongly interacting matter at high baryonic densities and search for the QCD critical point by performing systematic scans at lower beam energies. Results from the RHIC BES I program are intriguing. There indeed seem to be several signals suggesting a softening of the equation of state, which may result from a first-order transition, as well as possible indications of a critical point. In light of these intriguing results, several accelerator and detector upgrades have been planned to conduct the phase II of the RHIC BES during the period 2017-2020. The goal of the RHIC BES II is discovery of the QCD critical point by performing high luminosity scans within the interesting beam energy range revealed through explorations at RHIC BES I. Past experience has proven that even qualitative understanding of the physics encoded within the RHIC experimental data requires substantial theoretical input based on QCD calculations as well as detailed, quantitative modeling of the medium created at the RHIC. However, the coordinated theoretical and modeling efforts necessary for comprehensive understanding of the RHIC BES data is presently lacking. The purpose of this workshop was to gather a small group of expert theorists, phenomenologists and experimentalists to identify the necessary theoretical and modeling developments required for RHIC BES, to delineate a clear path towards extracting concrete physics utilizing the RHIC BES data, and to kick-start collaborations among theorists, phenomenologists and experimentalists to ensure that the necessary theoretical and modeling developments can be achieved before the start of the RHIC BES II experimental program.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Scanning Angle Raman spectroscopy in polymer thin film characterization

The focus of this thesis is the application of Raman spectroscopy for the characterization of thin polymer films. Chapter 1 provides background information and motivation, including the fundamentals of Raman spectroscopy for chemical analysis, scanning angle Raman scattering and scanning angle Raman scattering for applications in thin polymer film characterization. Chapter 2 represents a published manuscript that focuses on the application of scanning angle Raman spectroscopy for the analysis of submicron thin films with a description of methodology for measuring the film thickness and location of an interface between two polymer layers. Chapter 3 provides an outlook and future directions for the work outlined in this thesis. Appendix A, contains a published manuscript that outlines the use of Raman spectroscopy to aid in the synthesis of heterogeneous catalytic systems. Appendix B and C contain published manuscripts that set a foundation for the work presented in Chapter 2.

36 MATERIALS SCIENCE↗

Analysis of the effect of spherical aberrations on a solenoid scan

Solenoid scans are often used to determine the beam emittance of an intense relativistic electron beam (IREB). In a solenoid scan, the beam size is measured at a location downstream of the solenoid as a function of the strength of the solenoid magnetic field. The emittance is then inferred using a beam optics model of the transport of the beam through the solenoid magnet to the imaging location. This requires precise knowledge of the field strength and shape as a function of the current supplied to the solenoid. The beam optics model for an IREB needs to include an accurate model of the magnetic field. Unfortunately, most beam optics models do not include the effect of spherical aberrations which are inherent in a solenoid magnet. Spherical aberrations are manifested as an essentially quadratic increase in the solenoid magnetic field as a function of radius. One consequence of this is that the focal length will be dependent on the beam radius. This note examines the sensitivity of a typical solenoid scan performed on DARHT axis 2 to spherical aberrations. The sensitivity to spherical aberrations is examined as a function of the beam envelope size and the drift distance from the solenoid magnet to the imaging station.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Effective ZDC cross section derived from Vernier Scans during the RHICf run with polarized protons at 255 GeV in 2017

At RHIC the collision rate per IP is measured by the Zero Degree Calorimeters (ZDC). The collision rate, as measured by the ZDC, corresponds to the rate of mutual forward neutral particles above a variable threshold and within a certain coincidence window. During run 17 the detector was operated for the RHICf experiment in a slightly different configuration from the earlier standard polarized proton run. Due to the different configuration the ZDC detector was calibrated for the rhicf setup by performing a set of dedicated vernier scans. A total of 9 vernier scans were performed. This note presents the data and summarizes the results, i.e. effective ZDC cross section from those scans for the rhicf running period.

43 PARTICLE ACCELERATORS↗

H420 Imager Calibration Procedure: Field of View Scan

Gamma-ray imagers with coded apertures have a finite field of view (FOV) within which an image of a source can be generated. A “FOV scan” is a facet of imager calibration procedure that involves collecting specialized data for a range of source locations filling the FOV in order to understand and correct for differences in imager performance. Systematic distortions reveal relative displacements between internal imager components, which can be accounted for in data analysis. The success of this scan requires a stable imager position during the full measurement duration (~hours). This document summarizes the hardware and software tools required to conduct a FOV calibration scan of an H3D H420 Coded Aperture Gamma-Ray Imager.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

WREF Halo Streamline scanning lidar / Derived data / RHI

This dataset contains streamwise velocity retrieved from the Range Height Indicator (RHI) scans done by the UC Davis scanning Lidar. The quality control of the radial wind speed is performed following the algorithm of Beck & Kuhn (2017). Instantaneous realizations characterized by wind misalignment greater than 60 degrees (based on the closest VAD scan in time) are discarded.

17 WIND ENERGY↗

GPR Imaging for Deeply Buried Objects: A Comparative Study Based on Compositing of Scanning Frequencies and a Chirp Excitation Function

Compositing of ground penetrating radar (GPR) scans of differing frequencies have been found to produce cleaner images at depth using the Gaussian mixture model (GMM) feature of the expectation-maximization (EM) algorithm. GPR scans at various heights (“Stand Off”), as well as ground-based scans, have been studied. In this paper, we compare the GPR response from a chirp excitation function-based radar with the response from the EM GMM algorithm compositing process, using the same mix of frequencies. A chirp excitation pulse was found to be effective in delineating the defined buried object, but the resulting image is less sharp than the GMM EM method.

58 GEOSCIENCES↗

Realistic Noise Generation to Enhance Realism of Virtual Lidar Scans

Many real-world phenomena corrupt light detection and ranging (lidar) measurements, such as laser energy attenuation, variations in aerosol concentration and composition with height, and hard target returns. Accurate studies of lidar scans using virtual lidar methods should include some realistic model of these corrupting effects to generate more realistic simulations of lidar scans. We present a simple model that characterizes noise caused by energy attenuation and aerosol stratification. The model requires limited inputs and is developed for a Halo Photonics Streamline XR lidar but is readily generalizable for other lidar systems. A critical component of this model is a model of the standard deviation of measured wind speed as a function of the backscattered signal’s signal-to-noise ratio. We derive a general model for this behavior that can be adapted to different scan settings.

17 WIND ENERGY↗

Vertical profiles of the 3-D wind velocity retrieved from multiple wind lidars performing triple range-height-indicator scans

Abstract. Vertical profiles of 3-D wind velocity are retrieved from triple range-height-indicator (RHI) scans performed with multiple simultaneous scanning Doppler wind lidars. This test is part of the eXperimental Planetary boundary layer Instrumentation Assessment (XPIA) campaign carried out at the Boulder Atmospheric Observatory. The three wind velocity components are retrieved and then compared with the data acquired through various profiling wind lidars and high-frequency wind data obtained from sonic anemometers installed on a 300 m meteorological tower. The results show that the magnitude of the horizontal wind velocity and the wind direction obtained from the triple RHI scans are generally retrieved with good accuracy. However, poor accuracy is obtained for the evaluation of the vertical velocity, which is mainly due to its typically smaller magnitude and to the error propagation connected with the data retrieval procedure and accuracy in the experimental setup.

47 OTHER INSTRUMENTATION↗

Tools for pressure core sub-coring and pore-scale micro-CT (computed tomography) scans

Abstract. The pore habits of gas hydrate in natural sediment matrices provide essential clues for understanding physical (mechanical, thermal, hydraulic, and electrical) properties of hydrate-bearing sediments, yet there are no tools that can directly visualize the pore habits of natural gas hydrate other than indirect interpretation based on core-scale or field-scale observations. A significant challenge is to obtain a mini-core from pressure cores retrieved from natural reservoirs for high-resolution micro-CT (computed tomography) scans while maintaining pressure and temperature conditions required for stability of gas hydrate during all operational steps including manipulation, cutting, transferring, sub-coring and CT scanning. We present a new set of tools for pore-scale micro-CT imaging of natural hydrate-bearing sediments while maintaining pressure and temperature control. The tests with laboratory-prepared cores and pressure cores successfully demonstrate the capability of this set of tools to subsample a mini-core from pressure cores, transfer the mini-core to an X-ray transparent core holder, and conduct micro-CT scans. Successfully obtained CT images prove the functionality of this set of tools.

Seol, Yongkoo↗

Influences of lidar scanning parameters on wind turbine wake retrievals in complex terrain

Abstract. Scanning lidars enable the collection of spatially distributed measurements of turbine wakes and the estimation of wake properties such as magnitude, extent, and trajectory. Lidar-based characterizations, however, may be subject to distortions due to the observational system. Distortions can arise from the resolution of the measurement points across the wake, the projection of the winds onto the beam, averaging along the beam probe volume, and intervening evolution of the flow over the scan duration. Using a large-eddy simulation and simulated measurements with a virtual lidar model, we assess how scanning lidar systems may influence the properties of the retrieved wake using a case study from the Perdigão campaign. We consider three lidars performing range-height indicator sweeps in complex terrain, based on the deployments of lidars from the Danish Technical University (DTU) and German Aerospace Center (DLR) at the Perdigão site. The unwaked flow, measured by the DTU lidar, is well-captured by the lidar, even without combining data into a multi-lidar retrieval. The two DLR lidars measure a waked transect from different downwind vantage points. In the region of the wake, the observation system reacts to the smaller spatial and temporal variations of the winds, allowing more significant observation distortions to arise. While the measurements largely capture the wake structure and trajectory over its 4–5 D extent, limited spatial resolution of measurement points and volume averaging lead to a quicker loss of the two lobes in the near wake, smearing of the vertical bounds of the wake (< 30 m), wake center displacements up to 10 m, and dampening of the maximum velocity deficit by up to a third. The virtual lidar tool, coupled with simulations, provides a means for assessing measurement capabilities in advance of measurement campaigns.

17 WIND ENERGY↗

Mini Micropulse Lidar measurements in vertical and scanning modes

The Atmospheric Radiation Measurement (ARM) program operates ten Sigma Space (currently Droplet Measurement Technologies/DMT) micropulse lidar systems (MPL-4B-IDS/POL-FS series), which detect the backscattered light in two orthogonal linear polarization channels allowing to distinguish between spherical (e.g. water) and non-spherical (e.g. ice) scattering particles. The ARM MPLs have been providing valuable measurements to the aerosol and cloud research community for well over a decade. DMT&rsquo;s Mini-Micropulse lidar (MiniMPL) is a compact version of the standard MPL. It reduces the power-aperture product to minimize cost, size, weight, power requirements and has all the electronics integrated with optics in a single box. Although as a result, it has a lower detection range than the MPL, limiting the measurements to the troposphere, its performance is promised to match that of the standard MPL within the troposphere. The MiniMPL weighs 13 kg, and the complete system, consisting of an optical transceiver and a laptop running the data acquisition and post-processing software, fits in a storm case, allowing its transport on domestic or international flights. This can be especially valuable for short field campaigns or Intensive Operational Periods, where time is of the essence when replacing a faulty instrument. In addition, the scanning polarization lidar capability (MiniMPL-SCAN option) could be of great interest for satisfying ARM measurement needs for certain research topics related to clouds and precipitation. To evaluate its full potential in comparison with co-located remote sensing instruments including the ARM MPL-4B-IDS/POL-FS at SGP, a miniMPL was hosted at the ARM Southern Great Plains (SGP) mega-site in 2020 for approximately 3 months. During this time the miniMPL was tested in both vertical sampling and scanning modes.

54 ENVIRONMENTAL SCIENCES↗

Space astronomy and the slow-scan vidicon

Space astronomy is defined. In particular, the requirements for visual exploration of the Moon and Mars are outlined. The slow-scan vidicon is shown to be particularly useful as an astrophotographic instrument for space astronomy. The special instrumentation requirements for a slow-scan vidicon system are described for a Mars mission. Some of the techniques are illustrated with photos taken with a slow-scan vidicon system using as an optical objective the Mt. Wilson 60-in. telescope.

VIDICON↗