Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SCINTILLATIONS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 793 records · Page 44

Temperature and dopant concentration effects on proton light quenching in rare-earth inorganic scintillators [Slides]

Rare-earth inorganic scintillators have characteristics that offer optimal detection qualities for space applications as long a quenching is considered; Incident proton and electron response was measured in four different rare-earth inorganic scintillators of interest; We observed: A temperature effect on quenching for GAGG type detectors. A dopant concentration/decay time effect on quenching for GAGG detectors; Extracting the Birks’ factor for future detectors will improve the analysis of data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Tritium Betavoltaic Powered Sensor Platforms: Power Augmentation with Scintillating Particles

Betavoltaics (BV) are long-life power sources that typically convert beta particle radiation into electricity. Largely, the radioactive decays within the source go unharvested by the device. This work seeks to augment the power generation of BV devices by integration of scintillating particles within the radiative getter to convert beta emission which would otherwise not leave the getter into usable light for power generation. Silica-covered barium fluoride scintillating particles were integrated into a tritiated water getter. Power generation was increased from 100s of nW to µW levels with the addition of 0.2 wt. % particles into the getter. Nanowatt-scale sensor platforms were demonstrated with the µW BV devices and the maximum possible lifetime of such platforms was estimated. As this technique enables higher power density BV devices from conventional Si semiconductors (compared to wider bandgap BVs), the further implementation may lower the barrier-to-deployment of these long-life power/sensor platforms.

42 ENGINEERING↗

Hadron-Induced Radiation Damage in Fast Heavy Inorganic Scintillators

Fast and heavy inorganic scintillators with suitable radiation tolerance are required to face the challenges presented at future hadron colliders of high energy and intensity. Up to 5 GGy and 5 × 1018 neq/cm2 of one-MeV-equivalent neutron fluence is expected by the forward calorimeter at the Future Hadron Circular Collider. This paper reports the results of an investigation of proton- and neutron-induced radiation damage in various fast and heavy inorganic scintillators, such as LYSO:Ce crystals, LuAG:Ce ceramics, and BaF2 crystals. The experiments were carried out at the Blue Room with 800 MeV proton fluence up to 3.0 × 1015 p/cm2 and at the East Port with one MeV equivalent neutron fluence up to 9.2 × 1015 neq/cm2, respectively, at the Los Alamos Neutron Science Center. Experiments were also carried out at the CERN PS-IRRAD proton facility with 24 GeV proton fluence up to 8.2 × 1015 p/cm2. Research and development will continue to develop LuAG:Ce ceramics and BaF2:Y crystals with improved optical quality, F/T ratio, and radiation hardness.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Interplanetary Scintillation

Interplanetary scintillation (IPS) has been used as a diagnostic of solar wind speed and interplanetary plasma turbulence, allowing inference of speed and electron density power spectrum close to the Sun and out of the ecliptic. In that context, IPS is 'signal' and provides scientifically interesting data. IPS is also of interest because amplitude and phase perturbations imposed on radio waves are 'noise' for telemetry and precision Doppler tracking of deep space probes and for some radio astronomical observations. This paper briefly reviews the connection between scattering observables and the electron density power spectrum. Interplanetary phase scintillation on time scales of 100 to 10 000 seconds is an important noise in mass determinations of small solar system bodies during space-probe fly-bys and in searches for low-frequency gravitational radiation.

waves deep space probes electron density power spe↗

A Global Model for Estimating Atmospheric Phase Scintillation Statistics

Since 2007, the National Aeronautics and Space Administration (NASA) has been collecting atmospheric phase turbulence data from various NASA ground stations throughout the world. The goal of these measurement campaigns has been to generate statistics to characterize the local site turbulence conditions and their impact on widely distributed ground based antenna arrays. This is of critical importance for the situation of uplink arraying, in which a priori knowledge of the fast varying turbulent conditions of water vapor in the troposphere may not be known, and will impact the power combining efficiency of ground based transmitting arrays. Therefore, the design of these type of systems will be dependent on the local climatology of the particular ground station site. Based on the 30+ station years of data collected characterizing atmospheric phase scintillation statistics at various sites, a global model is presented which attempts to predict the average phase statistics of a generic site based on local surface weather data, such as surface pressure, temperature, relative humidity, wind speed, and median wind direction. A model is proposed and based on a standard log power distribution similar to amplitude scintillation models trained on the existing data sets and shows reasonable accuracy against existing data sets.

propagation↗

Fast Neutron Spectroscopy with Organic Scintillation Detectors in a High-Radiation Environment

Organic scintillators with pulse shape discrimination capability are widely used in both research and practical applications of neutron detection. The neutron and gamma-ray identification performance of the detector depends on the classification algorithms, noise filters and pileup rejection criteria in a high-flux bremsstrahlung radiation environment. In this paper, a technique has been developed and implemented for the neutron detection with multiple filter and discrimination steps, which to a high confidence level eliminates counting of gamma-ray pulses. Such a technique is merited when making measurements in a high flux bremsstrahlung and secondary fluorescence environment. The EJ-309 and stilbene detectors coupled to the digital data acquisition system were used for the calibration assessments with standard gamma-ray and neutron sources such as 137Cs, 60Co, 252Cf, and Am-Be. The MCNPX-PoliMi and GEANT4 toolkits were used to simulate the light output and the optical photon transport in the scintillators and create detector response functions for each type of detector. The neutron spectrum unfolding algorithm, GRAVELW, was used to recreate and calibrate with the Am-Be as final step before applying the neutron detection system to extract fusion neutron spectra generated in an intense bremsstrahlung radiation environment. This new technique described offers the user the ability to measure neutron spectra in a high-flux gamma-ray field and tune the parameters to meet required filtering needs.

Neutron Detector, Organic Scintillator, PulseShape↗

Impacts of Atmospheric Ultrafast Kelvin Waves on Radio Scintillations in the Equatorial Ionosphere

We present a statistical analysis of the amplitudes of GPS scintillations (S4 index) observed throughout 2008–2010 using the satellite radio occultation measurements of the Constellation Observing System for Meteorology, Ionosphere, and Climate (COSMIC). Here, for the first time, periodic variability in the occurrence of S4 is investigated using these data. Significant variations of S4 with periods of 2.5-4 days (quasi-3 days) are identified from the observations during postsunset hours (1900-2400 local time) between 15°S-15°N magnetic latitude during this 3-year interval. Coherence analyses of these variations with the geomagnetic Ap index, solar EUV irradiance, and atmospheric wind measurements from an equatorial mesosphere meteor radar at Thumba, India (8.5°N, 77°E) are performed, providing a measure of the relationship between variations in the scintillations and potential drivers. The quasi-3-day variations in S4 are found to covary with the variations of the three drivers examined. In particular, the S4 signatures are found to be coherent with the atmospheric ultrafast Kelvin (UFK) planetary waves characterized by the zonal wind measurements of the radar. This study shows that these UFK waves are as important as the solar and geomagnetic drivers in forcing the day-to-day variations of the occurrence of equatorial spread F.

Ultra Fast Kelvin planetary wave↗

Room-temperature scintillation properties of cerium-doped REOX (RE=Y, La, Gd, and Lu; X=F, Cl, Br, and I)

The scintillation properties of cerium-doped oxyhalides following the general formula REOX (RE=Y, La, Gd, and Lu; X=F, Cl, Br, and I) are reported. These materials were synthesized under dry conditions as microcrystalline powders from conventional solid state reactions. The room temperature X-ray excited emission and scintillation decay curves were measured and analyzed for each material. Additionally, the hygroscopic nature of the oxychlorides and oxybromides was compared to that of their corresponding rare earth halides. The yttrium, lanthanum, and gadolinium oxychlorides, and all of the oxybromides and oxyiodides are found to be activated by Ce{sup 3+}. GdOBr doped with 0.5% Ce{sup 3+} has the highest light output with a relative luminosity of about one-half that of LaBr{sub 3}: Ce{sup 3+}. It displays a single exponential decay of 30 ns.

36 MATERIALS SCIENCE↗

Investigation of the neutron response anisotropy in crystalline organic scintillators.

An anisotropy in the response of crystalline organic scintillators such as anthracene to neutron elastic scattering interactions has been known for some time. Both the amplitude and the time structure of the scintillation light pulse vary with the direction of the proton recoil with respect to the crystalline axes. In principle, this effect could be exploited to develop compact, high-efficiency fast neutron detectors that have directional sensitivity via a precise measurement of the pulse shape. We are investigating the feasibility and sensitivity of such a detector, particularly for neutrons in the fission energy spectrum. Here we will report new measurements of the pulse shape dependence on proton recoil angle in anthracene and stilbene single crystals, for proton energies in the few MeV range. Digital pulse acquisition and processing are used to allow an exploration of different pulse shape analysis techniques.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Scintillating 99Tc Selective Ion Exchange Resins

Scintillating technetium (99Tc) selective ion exchange resins have been developed and evaluated for equilibrium capacities and detection efficiencies. These resins can be utilized for the in-situ concentration and detection of low levels of pertechnetate anions (99TcO4-) in natural waters. Three different polystyrene type resin support materials were impregnated with varying amounts of tricaprylmethylammonium chloride (Aliquat 336) extractant, several different scintillating fluors and wavelength shifters. The prepared resins were contacted batch-wise to equilibrium over a wide range of 99TcO4- concentrations in natural water. The measured capacities were used to develop Langmuir adsorption isotherms for each resin. 99Tc detection efficiencies were determined and up to 71.4 ± 2.6% was achieved with some resins. The results demonstrate that a low level detection limit for 99TcO4- in natural waters can be realized.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Radoptic Effect in InP and GaN for Ultrafast Scintillator Applications

Ultrafast scintillators are the subject of current research in an effort to better resolve ultrafast phenomena in high-energy density physics (HEDP) experiments. Despite extensive research on new scintillator materials, the essential mechanism of energy absorption, excitation, and photo-emission has remained unchanged for over 50 years. Recently, a new class of semiconductor detector has been developed using the radoptic effect, or the change of refractive index when subjected to radiation, in an attempt to record events faster than conventional scintillators.1 This study was designed for the observation of the radoptic effect by optical interferometry in different semiconductors (InP, InP:S, GaN, and GaN:Mg) to experimentally determine the fastest and most sensitive materials for the optimization of current radsensors.

InP, GaN, radoptic, scintillator, ultrafast↗

Feasibility Testing of Delayed Scintillator Screens for Indirect Digital Neutron Radiography of Irradiated Nuclear Fuel

Neutron radiography provides information about the internal condition of irradiated nuclear fuels. Traditionally, neutron radiography of highly radioactive irradiated nuclear fuels has been done with film using indirect radiography methods.[1] While indirect film neutron radiography is insensitive to gamma radiation from radioactive samples, it is a time-consuming and labor-intensive process. Digital neutron radiography requires a fraction of the time to produce a neutron radiograph compared to film-based processes. However, electronic components of digital radiography systems can easily be damaged by gamma radiation, which typically precludes use of digital systems for examination of highly radioactive objects, though recent work has demonstrated that some digital neutron radiography systems can indeed directly examine such samples.[2,3] This paper describes experiments performed using a hybrid transfer-digital method with an activated scintillator screen that can record an image that is subsequently read by a digital camera. The screens used in this study use a dysprosium neutron converter that records a latent image in the form of activation while in a neutron beam, then is physically transported away from the beam and sample to a digital camera elsewhere to record the image while the activated dysprosium decays and the adjacent scintillator produces light from interactions with the decay radiation. This approach could accelerate radiographic examination of irradiated nuclear fuels compared to the current transfer method with film. Current indirect imaging infrastructure was modified and augmented with a digital system. A digital neutron radiograph of a highly-radioactive irradiated nuclear fuel pins was produced in ~20 minutes, which is a significant improvement compared to the current process that takes almost a full day to produce a radiograph.

99 GENERAL AND MISCELLANEOUS↗

Efficiency Calculation for an In-situ Beta Nuclide Monitoring System Based on a Plastic Scintillator - 18193

A plastic scintillator performance for an in-situ measurement system was analyzed using both simulation and experimental methods. The measurement results of four major pure beta-emitting radionuclides - namely H-3. C-14, P-32 and Sr-90/Y-90 - were compared with those from a Monte Carlo N-particle (MCNP) code simulation. Good agreement between the simulation and experimental results was observed for P-32 and Sr-90/Y-90. However, due to the short range of their beta particles in water, the efficiency for both H-3 and C-14 was rather low, and these radionuclides could not be detected. The optimal thickness for the plastic scintillator was identified, as was its suggested diameter. The effect of water depth on system performance was also considered. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Water Scintillation under Proton Beam Exposure

Ionizing radiation has been accepted as an effective way to treat cancer patients by killing malignant tumors through localized energy deposition. Intensity modulated proton therapy is an advanced radiation delivery technique that provides a highly conformal dose, which converges to the target with less integral dose to normal tissue and organs. Radiation therapy treatments all require an extensive quality assurance (QA) program to ensure that the patient treatment plan is safe and could achieve its objective. Part of this process requires measuring and validating that the dose is reaching the target accurately and with the proper dose. Established QA methods are either costly, inconvenient or time consuming. Scintillation of water when exposed to gamma rays and electron beams has been observed and several QA methods have proposed to take advantage of this phenomena. The water scintillation phenomenon has recently been observed for proton beams as well. This study measured the light produced by proton beam passing water using a cooled charged-coupled device (CCD) camera and demonstrated how these finding could be used to develop a low-cost, efficient, and accurate QA process to verify proton beam spot location, spot shape, and 3D dose distribution. (authors)

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Measurements with silicon photomultipliers of dose-rate effects in the radiation damage of plastic scintillator tiles in the CMS hadron endcap calorimeter

Measurements are presented of the reduction of signal output due to radiation damage for two types of plastic scintillator tiles used in the hadron endcap (HE) calorimeter of the CMS detector. The tiles were exposed to particles produced in proton-proton (pp) collisions at the CERN LHC with a center-of-mass energy of 13 TeV, corresponding to a delivered luminosity of 50 fb−1. The measurements are based on readout channels of the HE that were instrumented with silicon photomultipliers, and are derived using data from several sources: a laser calibration system, a movable radioactive source, as well as hadrons and muons produced in pp collisions. Results from several irradiation campaigns using 60Co sources are also discussed. The damage is presented as a function of dose rate. Within the range of these measurements, for a fixed dose the damage increases with decreasing dose rate.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Emergence of Uranium as a Distinct Metal Center for Building Intrinsic X‐ray Scintillators

Abstract The combination of high atomic number and high oxidation state in U VI materials gives rise to both high X‐ray attenuation efficiency and intense green luminescence originating from ligand‐to‐metal charge transfer. These two features suggest that U VI materials might act as superior X‐ray scintillators, but this postulate has remained substantially untested. Now the first observation of intense X‐ray scintillation in a uranyl–organic framework ( SCU‐9 ) that is observable by the naked eye is reported. Combining the advantage in minimizing the non‐radiative relaxation during the X‐ray excitation process over those of inorganic salts of uranium, SCU‐9 exhibits a very efficient X‐ray to green light luminescence conversion. The luminescence intensity shows an essentially linear correlation with the received X‐ray intensity, and is comparable with that of commercially available CsI:Tl. SCU‐9 possesses an improved X‐ray attenuation efficiency ( E >20 keV) as well as enhanced radiation resistance and decreased hygroscopy compared to CsI:Tl.

Wang, Yaxing↗

Toward Scintillator High‐Gain Avalanche Rushing Photoconductor Active Matrix Flat Panel Imager ( SHARP ‐ AMFPI ): Initial fabrication and characterization

Purpose We present the first prototype Scintillator High‐Gain Avalanche Rushing Photoconductor Active Matrix Flat Panel Imager ( SHARP ‐ AMFPI ). This detector includes a layer of avalanche amorphous Selenium (a‐Se) ( HARP ) as the photoconductor in an indirect detector to amplify the signal and reduce the effects of electronic noise to obtain quantum noise‐limited images for low‐dose applications. It is the first time avalanche a‐Se has been used in a solid‐state imaging device and poses as a possible solution to eliminate the effects of electronic noise, which is crucial for low‐dose imaging performance of AMFPI . Methods We successfully deposited a solid‐state HARP structure onto a 24 × 30 cm 2 array of thin‐film transistors ( TFT array) with a pixel pitch of 85 μm. The HARP layer consists of 16 μm of a‐Se with a hole‐blocking and electron‐blocking layer to prevent charge injection from the high‐voltage bias and pixel electrodes, respectively. An electric field ( E S e ) up to 105 V μm −1 was applied across the a‐Se layer without breakdown. A 150 μm thick‐structured CsI:Tl scintillator was used to form SHARP ‐ AMFPI . The x‐ray imaging performance is characterized using a 30 kV p Mo/Mo beam. We evaluate the spatial resolution, noise power, and detective quantum efficiency at zero frequency of the system with and without avalanche gain. The results are analyzed using cascaded linear system model ( CLSM ). Results An avalanche gain of 76 ± 5 was measured at E S e = 105 V μm −1 . We demonstrate that avalanche gain can amplify the signal to overcome electronic noise. As avalanche gain is increased, image quality improves for a constant (0.76 mR ) exposure until electronic noise is overcome. Our system is currently limited by poor optical transparency of our high‐voltage electrode and long integrating time which results in dark current noise. These two effects cause high‐spatial frequency noise to dominate imaging performance. Conclusions We demonstrate the feasibility of a solid‐state HARP x‐ray imager and have fabricated the largest active area HARP sensor to date. Procedures to reduce secondary quantum and dark noise are outlined. Future work will improve optical coupling and charge transport which will allow for frequency DQE and temporal metrics to be obtained.

Scheuermann, James R.↗