Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SCINTILLATION COUNTER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 793 records · Page 44

MINERνA neutrino detector calibration

MINERνA is a neutrino scattering experiment that uses Fermilab’s NuMI beamline. Its goal is to measure cross-sections for neutrino scattering from different nuclei. Precise knowledge of these cross-sections is vital for current and future neutrino oscillation experiments. In order to measure these values to a high degree of accuracy, it is essential that the detector be carefully calibrated. Here, we describe in-situ calibration and cross-checks.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Differential energy spectra of low energy (less than 8.5 MeV per nucleon) heavy cosmic rays during solar quiet times

Explorer 47 satellite observations of carbon, oxygen, and heavier nuclei differential energy spectra below 8.5 MeV/nucleon are presented for solar quiet time periods. A dE/dx vs E method for particle identification and energy determination was used. The instrumentation telescope included an isobutane proportional counter, a surface barrier Si detector, and a cylindrical plastic scintillator anticoincidence shield. The observations were performed outside the bow-shock and in the ecliptic plane. Results show an anisotropy of about 25% at 22 degrees west of the sun with a C/O ratio of 0.5 supporting a solar origin. The low energy portions of the C and O spectra have steep negative slopes, and the corresponding power law is given. Peculiarities in the O spectrum are discussed.

Hovestadt, D.↗

The X-ray Timing Explorer

The capabilities of the X-ray Timing Explorer (XTE) are described with particular attention paid to current scientific problems it will address, from galactic neutron star systems to active galactic nuclei. It features a low-background continuous 2-200 keV response with large apertures (a 0.63 sq m proportional counter array and a 0.16 sq m dual rocking NaI/CsI scintillation array). Rapid response (in hours) to temporal phenomena, e.g., transients, is obtained by virtue of a scanning all-sky monitor and rapid maneuverability. The XTE will carry out detailed energy-resolved studies of phenomena close to neutron stars (e.g., quasi-periodic oscillations) because of its submillisecond timing (to 10 microsec), its high telemetry rates (to 256 kbs), and the high throughput of its data system (to greater than about (200,000 c/sec).

Bradt, H. V.↗

The X-ray Timing Explorer

The capabilities of the X-ray Timing Explorer (XTE) are described with particular attention paid to current scientific problems it will address from galactic neutron star systems to active galactic nuclei. It features a low-background continuous 2-200 keV response with large apertures (a 0.63 sq m proportional counter array and a 0.16 sq m dual rocking NaI/CsI scintillation array). Rapid response (in hours) to temporal phenomena, e.g. transients, is obtained by virtue of a scanning all-sky monitor and rapid maneuverability. XTE will carry out detailed energy-resolved studies of phenomena close to neutron stars (e.g. QPO's) because of its submillisecond timing, its high telemetry rates, and the high throughput of its data system.

Bradt, H. V.↗

Next-generation neutron detection using a 6 Li glass scintillator composite

Neutron detectors are crucial in fundamental science, nuclear security, safeguards, and civil applications. 3 He-filled gas proportional counters are the gold standard for thermal neutron detection, prized for their efficiency, neutron/gamma discrimination, and stability; however, the scarcity of 3 He has prompted the search for alternatives. Here, we introduce a neutron detector design based on a scintillating composite consisting of 6 Li glass scintillator particles dispersed in an organic matrix. A detector consisting of this scintillating composite, photomultiplier tubes (PMTs) for optical detection, and electronics for reading out the PMT signal in both pulse and current modes was prototyped and characterized using various neutron and gamma sources. The prototype achieves a measured intrinsic detection efficiency of 6.70 ± 0.01%, a die-away time of 10.3 ± 0.1 μs, a negligible gamma misidentification probability, and response linearity up to at least 3.7 × 10 6 incident neutrons/s established via a cross-calibration technique. This detector holds the potential to outperform traditional 3 He-gas-based neutron detection systems, offering a viable alternative amidst the ongoing 3 He shortage and promising advancements in neutron detection technology.

47 OTHER INSTRUMENTATION↗

Fast multiplicity counter featuring stilbene detectors for special nuclear material assay

The Treaty on the Nonproliferation of Nuclear Weapons demands for new instruments to prevent diversion of fissile material and safeguard controls. We present a fast neutron multiplicity counting system based on organic scintillators, i.e. liquid EJ-309 and stilbene. The system is able to detect fission correlated counts and photon and neutron multiplets, needed to quantify fissile mass, without the need of complex electronic circuitry and unfolding procedures, required in moderated systems. Moderated system, typically based on helium-3 detectors, feature a gate time of hundreds of microseconds. Conversely, the use of organic scintillators allows an exceptionally short gate time of hundreds of nanoseconds. This results in a reduction of accidental neutron coincidence. In our system, the superior gamma-neutron discrimination capabilities of stilbene scintillators allow to measure high-order multiplicities (> 3) and the inspection of complex source terms. This counter is thus also suitable for the assay of newer fuels containing plutonium and other fissionable actinides. A prototypal version of the well-counter was assembled and tested at the University of Michigan, using a spontaneous fission and an (a,n) neutron source, i.e. 252Cf and PuBe respectively. Presented measured results show excellent agreement with simulations. The viability of the system to discriminate time-correlated fission neutrons from random, uncorrelated neutrons was proved. An experimental campaign will be carried out at Idaho National Laboratory in August 2015 to characterize weapon grade plutonium samples.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Dark matter searches for monoenergetic neutrinos arising from stopped meson decay in the Sun

Dark matter can be gravitationally captured by the Sun after scattering off solar nuclei. Annihilations of the dark matter trapped and accumulated in the centre of the Sun could result in one of the most detectable and recognizable signals for dark matter. Searches for high-energy neutrinos produced in the decay of annihilation products have yielded extremely competitive constraints on the spin-dependent scattering cross sections of dark matter with nuclei. Recently, the low energy neutrino signal arising from dark-matter annihilation to quarks which then hadronize and shower has been suggested as a competitive and complementary search strategy. These high-multiplicity hadronic showers give rise to a large amount of pions which will come to rest in the Sun and decay, leading to a unique sub-GeV neutrino signal. We here improve on previous works by considering the monoenergetic neutrino signal arising from both pion and kaon decay. We consider searches at liquid scintillation, liquid argon, and water Cherenkov detectors and find very competitive sensitivities for few-GeV dark matter masses.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measurement of the U 235 ( n , f ) prompt fission neutron spectrum from 10 keV to 10 MeV induced by neutrons of energy from 1 MeV to 20 MeV

The characterization of fission-driven nuclear systems primarily relies on calculations of neutron-induced chain reactions, and these calculations require evaluated nuclear data as input. Calculation accuracy heavily depends on input nuclear data evaluation accuracy, and thus high precision on the experimental input to the nuclear data evaluation is essential for fundamental quantities like the energy spectrum of neutrons emitted from neutron-induced fission (i.e., the prompt fission neutron spectrum, PFNS). Despite decades of measurement efforts, prior to the measurements described in this work there were only three literature data sets for the 235 U(n,f) PFNS at incident neutron energies above 1.0 MeV considered reliable for inclusion in nuclear data evaluations and no reliable data sets above 3.0 MeV incident neutron energy. In this work we report on new measurements of the 235 U(n,f) PFNS spanning a grid of 1.0–20.0 MeV in incident neutron energy and 0.01–10.0 MeV in outgoing (PFNS) neutron energy. These measurements were carried out at the Weapons Neutron Research facility at the Los Alamos Neutron Science Center and used a multifoil parallel-plate avalanche counter target with both a Li-glass and a liquid scintillator detector array in separate experiments to span the quoted outgoing neutron energy ranges. The PFNS results are shown in terms of the energy spectra themselves as well as the average PFNS energy $(\langle{E}\rangle)$ and ratios of $\langle{E}\rangle$ at forward and backward angles. Here, the results are compared with literature data and selected nuclear data evaluations. Generally, the data agree with the ENDF/B-VIII.0 evaluation below 5.0-MeV incident neutron energy and more closely with the JEFF-3.3 evaluation above 5.0 MeV, though no evaluations considered for comparison in this work agree with the data across all of the incident and outgoing neutron energies shown, especially in regions where the third-chance fission process becomes available. Additionally, we show a ratio of the present PFNS results for 235 U(n, f) with a recent and highly correlated experiment to measure the 239 Pu(n, f) PFNS at the same experimental facility and with nearly identical equipment and analysis procedures. Many observations reported in this work are the first of their kind and represent significant advancements for knowledge of the 235 U(n, f) PFNS.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

New CHOD detector for the NA62 experiment at CERN

The New CHOD is a scintillation hodoscope with a pad structure featuring a total of 148 counters. The signal from each pad is read out using wavelength-shifting fibers and two or four SensL SiPMs with a sensitive area of 3 × 3 mm{sup 2}. This photodetector has 4774 pixels 35 × 35 μm{sup 2} in size. The key parameters (photon detection efficiency, dark current, crosstalk, and gain) were measured for 500 SiPMs.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Fuel Motion Monitoring System at TREAT – FY2017 Instrumentation Summary

This document is a report summarizing FY2017 efforts related to the Transient Reactor Test Facility (TREAT) Fuel Motion Monitoring System, "hodoscope," refurbishment campaign. TREAT is an air-cooled, graphite-moderated, heterogeneous test facility designed to evaluate reactor fuels and structural materials under conditions that simulate various types of transient overpower and under-cooling situations in a nuclear reactor. Fuel meltdowns, metal-water reactions, thermal interaction between overheated fuel and coolant, and the transient behavior of ceramic fuel for high-temperature systems can be studied. A key instrument that monitors fuel motion as these events take place is the fast neutron hodoscope. The hodoscope is designed to allow for pre-, during-, and post- transient imaging of fuel within a test loop in the center of the reactor core. The preferred technique for imaging is detection of fast neutrons produced by fission in the test fuel, travelling unmoderated through an empty row of core fuel assemblies and then through a multi-slot collimator to a 360-detector array. Due to the age of the instrument, a refurbishment of the hodoscope’s fast neutron detection capability is necessary to support real-time, fuel-position experimental data collection. One particular challenge in this regard is related to the refurbishment of the fast-neutron-sensing detector elements in the detector array. This report summarizes major activities and accomplishments related to the FMMS refurbishment in FY2017. Of particular note was work related to identifying options for new proton recoil scintillator wafer and initial examination of the TREAT proton recoil proportional counter detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Full Scale Coated Fiber Neutron Detector Measurements

Radiation portal monitors used for interdiction of illicit materials at borders include highly sensitive neutron detection systems. The main reason for having neutron detection capability is to detect fission neutrons from plutonium. The currently deployed radiation portal monitors (RPMs) from Ludlum and Science Applications International Corporation (SAIC) use neutron detectors based upon 3He-filled gas proportional counters, which are the most common large neutron detector. There is a declining supply of 3He in the world, and thus, methods to reduce the use of this gas in RPMs with minimal changes to the current system designs and sensitivity to cargo-borne neutrons are being investigated. Four technologies have been identified as being currently commercially available, potential alternative neutron detectors to replace the use of 3He in RPMs. These technologies are: 1) Boron trifluoride (BF3)-filled proportional counters, 2) Boron-lined proportional counters, 3) Lithium-loaded glass fibers, and 4) Coated non-scintillating plastic fibers. Reported here are the results of tests of the full-scale 6Li/ZnS(Ag)-coated non-scintillating plastic fibers option. This testing measured the required performance for neutron detection efficiency and gamma ray rejection capabilities of a system manufactured by Innovative American Technology (IAT) and Saint Gobain, and is a follow-up report to an earlier one on a smaller prototype system.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Coated Fiber Neutron Detector Test

Radiation portal monitors used for interdiction of illicit materials at borders include highly sensitive neutron detection systems. The main reason for having neutron detection capability is to detect fission neutrons from plutonium. The currently deployed radiation portal monitors (RPMs) from Ludlum and Science Applications International Corporation (SAIC) use neutron detectors based upon 3He-filled gas proportional counters, which are the most common large neutron detector. There is a declining supply of 3He in the world, and thus, methods to reduce the use of this gas in RPMs with minimal changes to the current system designs and sensitivity to cargo-borne neutrons are being investigated. Reported here are the results of tests of the 6Li/ZnS(Ag)-coated non-scintillating plastic fibers option. This testing measured the required performance for neutron detection efficiency and gamma ray rejection capabilities of a system manufactured by Innovative American Technology (IAT).

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

MPACT Fast Neutron Multiplicity System Design Concepts

This report documents work performed by Idaho National Laboratory and the University of Michigan in fiscal year (FY) 2012 to examine design parameters related to the use of fast-neutron multiplicity counting for assaying plutonium for materials protection, accountancy, and control purposes. This project seeks to develop a new type of neutron-measurement-based plutonium assay instrument suited for assaying advanced fuel cycle materials. Some current-concept advanced fuels contain high concentrations of plutonium; some of these concept fuels also contain other fissionable actinides besides plutonium. Because of these attributes the neutron emission rates of these new fuels may be much higher, and more difficult to interpret, than measurements made of plutonium-only materials. Fast neutron multiplicity analysis is one approach for assaying these advanced nuclear fuels. Studies have been performed to assess the conceptual performance capabilities of a fast-neutron multiplicity counter for assaying plutonium. Comparisons have been made to evaluate the potential improvements and benefits of fast-neutron multiplicity analyses versus traditional thermal-neutron counting systems. Fast-neutron instrumentation, using for example an array of liquid scintillators such as EJ-309, have the potential to either a) significantly reduce assay measurement times versus traditional approaches, for comparable measurement precision values, b) significantly improve assay precision values, for measurement durations comparable to current-generation technology, or c) moderating improve both measurement precision and measurement durations versus current-generation technology. Using the MCNPX-PoliMi Monte Carlo simulation code, studies have been performed to assess the doubles-detection efficiency for a variety of counter layouts of cylindrical liquid scintillator detector cells over one, two, and three rows. Ignoring other considerations, the best detector design is the one with the most detecting volume. However, operational limitations guide a) the maximum acceptable size of each detector cell (due to PSD performance and maximum-acceptable per-channel data throughput rates, limited by pulse pile-up and the processing rate of the electronics components of the system) and b) the affordability of a system due to the number of total channels of data to be collected and processed. As a first estimate, it appears that a system comprised of two rows of detectors 5" Ø $\times$ 3" would yield a working prototype system with excellent performance capabilities for assaying Pu-containing items and capable of handling high signal rates likely when measuring items with Pu and other actinides. However, it is still likely that gamma-ray shielding will be needed to reduce the total signal rate in the detectors. As a first step prior to working with these larger-sized detectors, it may be practical to perform scoping studies using small detectors, such as already-on-hand 3" Ø $\times$ 3" detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Compensated gadolinium-loaded plastic scintillators for thermal neutron detection (and counting)

Plastic scintillator loading with gadolinium-rich organometallic complexes shows a high potential for the deployment of efficient and cost-effective neutron detectors. Due to the low-energy photon and electron signature of thermal neutron capture by gadolinium-155 and gadolinium-157, alternative treatment to Pulse Shape Discrimination has to be proposed in order to display a trustable count rate. This paper discloses the principle of a compensation method applied to a two-scintillator system: a detection scintillator interacts with photon radiation and is loaded with gadolinium organometallic compound to become a thermal neutron absorber, while a non-gadolinium loaded compensation scintillator solely interacts with the photon part of the incident radiation. Posterior to the nonlinear smoothing of the counting signals, a hypothesis test determines whether the resulting count rate after photon response compensation falls into statistical fluctuations or provides a robust image of a neutron activity. A laboratory prototype is tested under both photon and neutron irradiations, allowing us to investigate the performance of the overall compensation system in terms of neutron detection, especially with regards to a commercial helium-3 counter. The study reveals satisfactory results in terms of sensitivity and orientates future investigation toward promising axes. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

On the Compliance of Simbol-X Mirror Roughness with its Effective Area Requirements

Surface microroughness of X-ray mirrors is a key issue for the angular resolution of Simbol-X to comply with the required one (<20 arcsec at 30 keV). The maximum tolerable microroughness for Simbol-X mirrors, in order to satisfy the required imaging capability, has already been derived in terms of its PSD (Power Spectral Density). However, also the Effective Area of the telescope is affected by the mirror roughness. In this work we will show how the expected effective area of the Simbol-X mirror module can be computed from the roughness PSD tolerance, checking its compliance with the requirements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Study of the performance of a large scale water-Cherenkov detector (MEMPHYS)

MEMPHYS (MEgaton Mass PHYSics) is a proposed large-scale water Cherenkov experiment to be performed deep underground. It is dedicated to nucleon decay searches, neutrinos from supernovae, solar and atmospheric neutrinos, as well as neutrinos from a future Super-Beam or Beta-Beam to measure the CP violating phase in the leptonic sector and the mass hierarchy. A full simulation of the detector has been performed to evaluate its performance for beam physics. The results are given in terms of ''migration matrices'' of reconstructed versus true neutrino energy, taking into account all the experimental effects.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Prompt neutron emission in the neutron-induced fission of 239 Pu and the spontaneous fission of 252 Cf: an unfolding story

Prompt neutron emission is one of the major observables in fission and critical to a sustained chain reaction. The prompt neutron emission spectrum and its precision are essential for adequately modeling the chain reaction for any given application. Within this context, a joint program, called Chi-Nu, was initiated by LANL [1] with the objective to improve the precision of experimental measurements of prompt neutron emission for neutron-induced fission of 235 U and 239 Pu as well as the spontaneous fission of 252 Cf. The measurements were carried out at the Weapons Neutron Research Facility at Los Alamos Neutron Science Center using two scintillator arrays for neutron detection and a PPAC (parallel-plate avalanche counter) for fission-fragment detection.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Investigation of Deuterium Loaded Materials Subject to X-Ray Exposure

Results are presented from an exploratory study involving x-ray irradiation of select deuterated materials. Titanium deuteride plus deuterated polyethylene, deuterated polyethylene alone, and for control, hydrogen-based polyethylene samples and nondeuterated titanium samples were exposed to x-ray irradiation. These samples were exposed to various energy levels from 65 to 280 kV with prescribed electron flux from 500 to 9000 μA impinging on a tungsten braking target, with total exposure times ranging from 55 to 280 min. Gamma activity was measured using a high-purity germanium (HPGe) detector, and for all samples no gamma activity above background was detected. Alpha and beta activities were measured using a gas proportional counter, and for select samples beta activity was measured with a liquid scintillator spectrometer. The majority of the deuterated materials subjected to the microfocus x-ray irradiation exhibited postexposure beta activity above background and several showed short-lived alpha activity. The HPE and nondeuterated titanium control samples exposed to the x-ray irradiation showed no postexposure alpha or beta activities above background. Several of the samples (SL10A, SL16, SL17A) showed beta activity above background with a greater than 4σ confidence level, months after exposure. Portions of SL10A, SL16, and SL17A samples were also scanned using a beta scintillator and found to have beta activity in the tritium energy band, continuing without noticeable decay for over 12 months. Beta scintillation investigation of as-received materials (before x-ray exposure) showed no beta activity in the tritium energy band, indicating the beta emitters were not in the starting materials.

x-ray irradiation↗