Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SAMPLING DEVICE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 793 records · Page 44

Establishment of new design criteria for GlidCop ® X-ray absorbers

Here, an engineering research program has been conducted at the Advanced Photon Source (APS) in order to determine the thermomechanical conditions that lead to crack formation in GlidCop ® , a material commonly used to fabricate X-ray absorbers at X-ray synchrotron facilities. This dispersion-strengthened copper alloy is a proprietary material and detailed technical data of interest to the synchrotron community is limited. The results from the research program have allowed new design criteria to be established for GlidCop ® X-ray absorbers based upon the thermomechanically induced fatigue behavior of the material. X-ray power from APS insertion devices was used to expose 30 GlidCop ® samples to 10000 thermal loading cycles each under various beam power conditions, and all of the samples were metallurgically examined for crack presence/geometry. In addition, an independent testing facility was hired to measure temperature-dependent mechanical data and uniaxial mechanical fatigue data for numerous GlidCop ® samples. Data from these studies support finite element analysis (FEA) simulation and parametric models, allowing the development of a thermal fatigue model and the establishment of new design criteria so that the thermomechanically induced fatigue life of X-ray absorbers may be predicted. It is also demonstrated how the thermal fatigue model can be used as a tool to geometrically optimize X-ray absorber designs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Artifact identification in X-ray diffraction data using machine learning methods

In situ synchrotron high-energy X-ray powder diffraction (XRD) is highly utilized by researchers to analyze the crystallographic structures of materials in functional devices ( e.g. battery materials) or in complex sample environments ( e.g. diamond anvil cells or syntheses reactors). An atomic structure of a material can be identified by its diffraction pattern along with a detailed analysis of the Rietveld refinement which yields rich information on the structure and the material, such as crystallite size, microstrain and defects. For in situ experiments, a series of XRD images is usually collected on the same sample under different conditions ( e.g. adiabatic conditions) yielding different states of matter, or is simply collected continuously as a function of time to track the change of a sample during a chemical or physical process. In situ experiments are usually performed with area detectors and collect images composed of diffraction patterns. For an ideal powder, the diffraction pattern should be a series of concentric Debye–Scherrer rings with evenly distributed intensities in each ring. For a realistic sample, one may observe different characteristics other than the typical ring pattern, such as textures or preferred orientations and single-crystal diffraction spots. Textures or preferred orientations usually have several parts of a ring that are more intense than the rest, whereas single-crystal diffraction spots are localized intense spots owing to diffraction of large crystals, typically >10 µm. In this work, an investigation of machine learning methods is presented for fast and reliable identification and separation of the single-crystal diffraction spots in XRD images. The exclusion of artifacts during an XRD image integration process allows a precise analysis of the powder diffraction rings of interest. When it is trained with small subsets of highly diverse datasets, the gradient boosting method can consistently produce high-accuracy results. The method dramatically decreases the amount of time spent identifying and separating single-crystal diffraction spots in comparison with the conventional method.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Mass recovery methods for trichloroethylene in plant tissue.

Monitoring expenses form a significant fraction of the costs associated with remediation of contaminated soil and groundwater sites. A novel monitoring method that could result in significant cost savings is the use of plants as monitoring devices; previous work indicates that plant tissue samples, especially trunk (core) and branch samples, can be used to delineate soil and groundwater plumes at phytoremediation sites. An important factor in reducing the uncertainty associated with this sampling method is development of a technique to analyze, both consistently and accurately, the chemicals stored in plant tissue samples. The present research presents a simple, robust, and inexpensive technique to recover most of the contaminant in plant branch tissue, irrespective of the age or species of the plant. Trichloroethylene (TCE) was the chemical analyzed. A number of headspace and solvent extraction techniques in the literature were evaluated, including headspace extraction at different incubation times and temperatures and solvent extraction using hexane or hot methanol. Extraction using hot methanol was relatively fast, simple, and reliable; this method recovered more than 89% of the TCE present in branches of five different tree species.

10 SYNTHETIC FUELS↗

The Viking mission to Mars.

In 1975 the National Aeronautics and Space Administration will launch two unmanned scientific payloads to make soft landings on Mars in 1976. They will be placed in orbit around the planet to perform a reconnaissance before landing. The spacecraft will be separated into an orbiter, which is sent to the surface. During the entry into the Martian atmosphere, Viking will make measurements of the composition and atmospheric structure. After landing, two cameras will be used to visually characterize the site. A device will be deployed to obtain a sample of the Mars surface, which will be returned to the lander for biological tests and for chemical analysis. The atmosphere at the surface will be chemically analyzed as well as the wind velocity, the humidity, and changes in temperature and pressure.

Soffen, G. A.↗

Automated array assembly, phase 2

Tasks of scaling up the tandem junction cell (TJC) from 2 cm x 2 cm to 6.2 cm and the assembly of several modules using these large area TJC's are described. The scale-up of the TJC was based on using the existing process and doing the necessary design activities to increase the cell area to an acceptably large area. The design was carried out using available device models. The design was verified and sample large area TJCs were fabricated. Mechanical and process problems occurred causing a schedule slippage that resulted in contract expiration before enough large-area TJCs were fabricated to populate the sample tandem junction modules (TJM). A TJM design was carried out in which the module interconnects served to augment the current collecting buses on the cell. No sample TJMs were assembled due to a shortage of large-area TJCs.

Carbajal, B. G.↗

Germanium accumulation-mode charge-injection-device process

Gallium doped germanium is suitable for applications in the detection of far infrared radiation. Measurements were made on experimental photoconductors (PCs), accumulation mode charge injection devices (AMCIDs), and the SSPC (a switched, sampled PC alternative to the AMCID). The results indicate that the SSPC, which had a responsivity near 1.5 amp/watt, is desirable for use in two dimensional detector arrays.

Moore, T. G.↗

Automated Mercury Dilatometer

Task of reading and recording indications of mercury dilatometer simplified by automatic system. Volume change of sample under test converted into electrical signal. Device modified by addition of resistance wire to mercury column. Height of column read indirectly by measuring resistance between terminals. Signal suitable for strip-chart recording or other processing.

Hong, S. D.↗

Electrophoresis device

A device for separating cellular particles of a sample substance into fractionated streams of different cellular species includes a casing having a distribution chamber, a separation chamber, and a collection chamber. The electrode chambers are separated from the separation chamber interior by means of passages such that flow variations and membrane variations around the slotted portion of the electrode chamber do not enduce flow perturbations into the laminar buffer curtain flowing in the separation chamber. The cellular particles of the sample are separated under the influence of the electrical field and the separation chamber into streams of different cellular species. The streams of separated cells enter a partition array in the collection chamber where they are fractionated and collected.

Rhodes, P. H.↗

Partial-Transmission Scintillation Detector for Ions

Only outer portion of ion beam sampled to prevent unnecessary energy losses. Measurement device allows only periphery of beam to pass through scintillation material. Total flux in uniform beam inferred from peripheral flux. Device provides readings without reducing energy of ions in middle of beam. Measurement device developed for ion beams used in studies of how fast heavy ions affect integrated-circuit chips.

Malone, C. J.↗

Solar cell reliability testing

The progress and initial data on accelerated stress tests on small amorphous silicon test samples from several manufacturers are reported. The test samples include both single and tandem junction devices.

Lathrop, J.↗

Measurement of the thermal conductivity of composites using heat flow sensors

A thermal conductivity measuring apparatus that uses heat flow sensors to measure the heat flux through samples was constructed of inexpensive materials. This device was used to measure the thermal conductivity (k) of two composites used in the space program that consist of fibrous or granular components embedded in a resin matrix. The k-values that were determined ranged from 0.035 to 0.059 Btu/h sq ft-F/ft (-163 to 553 F) and 0.029 to 0.035 Btu/h-sq ft-F/ft (77 to 212 F). Thermal conductivity values of the composites conformed to the rule of mixture. The accuracy of the system was found to be comparable to the guarded hotplate and it requires neither a skilled operator nor extensive maintenance.

Penn, B. G.↗

Statistical Evaluation of Molecular Contamination During Spacecraft Thermal Vacuum Test

The purpose of this paper is to evaluate the statistical molecular contamination data with a goal to improve spacecraft contamination control. The statistical data was generated in typical thermal vacuum tests at the National Aeronautics and Space Administration, Goddard Space Flight Center (GSFC). The magnitude of material outgassing was measured using a Quartz Crystal Microbalance (QCM) device during the test. A solvent rinse sample was taken at the conclusion of the each test. Then detailed qualitative and quantitative measurements were obtained through chemical analyses. All data used in this study encompassed numerous spacecraft tests in recent years.

Chen, Philip↗

Statistical Evaluation of Molecular Contamination During Spacecraft Thermal Vacuum Test

The purpose of this paper is to evaluate the statistical molecular contamination data with a goal to improve spacecraft contamination control. The statistical data was generated in typical thermal vacuum tests at the National Aeronautics and Space Administration, Goddard Space Flight Center (GSFC). The magnitude of material outgassing was measured using a Quartz Crystal Microbalance (QCM) device during the test. A solvent rinse sample was taken at the conclusion of each test. Then detailed qualitative and quantitative measurements were obtained through chemical analyses. All data used in this study encompassed numerous spacecraft tests in recent years.

Chen, Philip↗

Statistical Evaluation of Molecular Contamination During Spacecraft Thermal Vacuum Test

The purpose of this paper is to evaluate the statistical molecular contamination data with a goal to improve spacecraft contamination control. The statistical data was generated in typical thermal vacuum tests at the National Aeronautics and Space Administration, Goddard Space Flight Center (GSFC). The magnitude of material outgassing was measured using a Quartz Crystal Microbalance (QCNO device during the test. A solvent rinse sample was taken at the conclusion of each test. Then detailed qualitative and quantitative measurements were obtained through chemical analyses. All data used in this study encompassed numerous spacecraft tests in recent years.

Chen, Philip↗

Microelectric Heterogeneous Hybrid Devices for Space Applications

The existing projects designated as SACA (Sample Ampoule Cartridge/Container Assembly) and QMI (Quench Module Insert) at NASA's MSFC (Marshall Space Flight Center) involve development of high-temperature coating materials. A number of material systems need to be evaluated for this purpose. The requirement of these coating materials included high emissivity (approaching unity), sufficient physical strength, appropriate thermal conductivity to dissipate heat, and above all high temperature (T is equal to or greater than 2000 C) withstanding capability. Potential materials for applications considered were non-oxide based materials such as tungsten carbide, tantalum carbide, compounds of niobium, etc.

Mohammad A. Alim↗

Device Control Using Gestures Sensed from EMG

In this paper we present neuro-electric interfaces for virtual device control. The examples presented rely upon sampling Electromyogram data from a participants forearm. This data is then fed into pattern recognition software that has been trained to distinguish gestures from a given gesture set. The pattern recognition software consists of hidden Markov models which are used to recognize the gestures as they are being performed in real-time. Two experiments were conducted to examine the feasibility of this interface technology. The first replicated a virtual joystick interface, and the second replicated a keyboard.

Wheeler, Kevin R.↗

Fabrication and Testing of Habitat Components Using In-Situ Materials for Martian Exploration

The development of Mars for human activity will require the utilization of Martian materials in building habitats and working structures. One approach is to use polymer binders with regolith to form structural elements. Not only can useful composite materials be produced in this way but the radiation protection properties are also increased. This is important since only modest protection from space radiation is provided by the Martian atmosphere. We have studied composites fabricated using Martian regolith simulant and polymers which can be synthesized from local Martian materials for their potential use as radiation shields for manned Mars missions. To validate shielding effectiveness, composites are irradiated with a 55 MeV proton beam and neutron beams up to 800 MeV. Shielding effects on microelectronic devices are measured by placing them behind samples of the composites during irradiation. To measure structural properties of the composites, preliminary characterization and mechanical testing are made for the composites.

Kim, M.-H. Y.↗