Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SAMPLE POSITIONING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 793 records · Page 44

YOUNG STELLAR POPULATIONS IN MYStIX STAR-FORMING REGIONS: CANDIDATE PROTOSTARS

The Massive Young Star-Forming Complex in Infrared and X-ray (MYStIX) project provides a new census on stellar members of massive star-forming regions within 4 kpc. Here the MYStIX Infrared Excess catalog and Chandra -based X-ray photometric catalogs are mined to obtain high-quality samples of Class I protostars using criteria designed to reduce extragalactic and Galactic field star contamination. A total of 1109 MYStIX Candidate Protostars (MCPs) are found in 14 star-forming regions. Most are selected from protoplanetary disk infrared excess emission, but 20% are found from their ultrahard X-ray spectra from heavily absorbed magnetospheric flare emission. Two-thirds of the MCP sample is newly reported here. The resulting samples are strongly spatially associated with molecular cores and filaments on Herschel far-infrared maps. This spatial agreement and other evidence indicate that the MCP sample has high reliability with relatively few “false positives” from contaminating populations. But the limited sensitivity and sparse overlap among the infrared and X-ray subsamples indicate that the sample is very incomplete with many “false negatives.” Maps, tables, and source descriptions are provided to guide further study of star formation in these regions. In particular, the nature of ultrahard X-ray protostellar candidates without known infrared counterparts needs to be elucidated.

79 ASTRONOMY AND ASTROPHYSICS↗

Sign Problem in Tensor-Network Contraction

We investigate how the computational difficulty of contracting tensor networks depends on the sign structure of the tensor entries. Using results from computational complexity, we observe that the approximate contraction of tensor networks with only positive entries has lower computational complexity as compared to tensor networks with general real or complex entries. This raises the question of how this transition in computational complexity manifests itself in the hardness of different tensor-network-contraction schemes. We pursue this question by studying random tensor networks with varying bias toward positive entries. First, we consider contraction via Monte Carlo sampling and find that the transition from hard to easy occurs when the tensor entries become predominantly positive; this can be understood as a tensor-network manifestation of the well-known negative-sign problem in quantum Monte Carlo. Second, we analyze the commonly used contraction based on boundary tensor networks. The performance of this scheme is governed by the number of correlations in contiguous parts of the tensor network (which by analogy can be thought of as entanglement). Remarkably, we find that the transition from hard to easy—i.e., from a volume-law to a boundary-law scaling of entanglement—already occurs for a slight bias of the tensor entries toward a positive mean, scaling inversely with the bond dimension D , and thus the problem becomes easy the earlier the larger D occurs. This is in contrast both to expectations and to the behavior found in Monte Carlo contraction, where the hardness at fixed bias increases with the bond dimension. To provide insight into this early breakdown of computational hardness and the accompanying entanglement transition, we construct an effective classical statistical-mechanical model that predicts a transition at a bias of the tensor entries of 1 / D , confirming our observations. We conclude by investigating the computational difficulty of computing expectation values of tensor-network wave functions (projected entangled-pair states, PEPSs) and find that in this setting, the complexity of entanglement-based contraction always remains low. We explain this by providing a local transformation that maps PEPS expectation values to a positive-valued tensor network. This not only provides insight into the origin of the observed boundary-law entanglement scaling but also suggests new approaches toward PEPS contraction based on positive decompositions. Published by the American Physical Society 2025

Chen, Jielun (ORCID:0000000178411545)↗

ROSAT observations of X-ray-selected active galactic nuclei

We have observed sample of six optically faint, X-ray-selected active galactic nuclei with the Roentgen Satellite (ROSAT) Position Sensitive Proportional Counter (PSPC). These objects represents a sample of soft and hard spectrum sources; all were observed previously with the Einstein X-Ray Observatory. Included in this sample is EO132.8-4111, whose soft X-ray and ultraviolet flux distributions bear a striking resemblance to that of Mrk 841, but whose relative hard X-ray emission is much less than that of Mrk 841. The spectra are all fitted satisfactorily with single power-law models and their spectral indices (with one exception) agree with those estimated from the Einstein Image Propotional Counter (IPC) observations. Tests of short-term variability are carried out, with all sources showing constant count rates over the period of their ROSAT observations. Some sources do, however, show significant changes in count rate when compared to previous Einstein data taken a decade earlier.

Thompson, R. J., Jr.↗

Time-Resolved Spectroscopy of Insulator-Metal Transitions: Exploring Low-Energy Dynamics in Strongly Correlated Systems. Final Report

Transition metal oxides (TMOs) have attracted much attention in recent years. The strong coupling between charge, spin, and orbital degrees of freedom creates novel functional properties. The research at the interplay between ferromagnetism, ferroelectricity and conductivity provides a promising way to the development of future spintronic devices. The interface characterization of multifunctional oxide heterostructures is crucial to understand deeply the magnetic response, spin injection and spin transport. In year one, we characterized optically the magnetic property with the method of magnetization-induced second-harmonic generation (MSHG), which is a sensitive technique to selectively probe the interface where the spatial inversion symmetry is broken. The interface of n-type BaTiO 3 (BTO)/La 0.67 Sr 0.33 MnO 3 (LSMO) forms a Schottky barrier and displays a good diode effect. By applying an external electric field across the sample, we observe the magnetoelectric (ME) coupling effect to modulate the interface magnetization. The voltage dependent magnetic contrast sharply vanishes at positive voltage (applied to LSMO contact) and reveals a ferromagnetic (FM)-to- antiferromagnetic (AFM) transition occurring at the interface, while the magneto-optic Kerr effect (MOKE) indicates that the bulk property is not affected. The strain mediated mechanism and ferroelectric (FE) polarization induced charge medicated mechanism are both discussed, but they do not play an important role in the observed magnetization transition. A new mechanism is proposed - the injected minority spins through strong Hund's interaction with the local magnetic moments at positive voltage weaken the double-exchange interaction of nearby Mn e g electrons, thereby reducing the ferromagnetic (FM) ordering. The dominant superexchange interaction of localized t 2g electrons finally leads to the AFM configuration. By reducing the electron carrier concentration of BTO, a positive voltage shift of the transition is observed. The oxygen richer sample with lower carrier concentration requires a higher voltage to increase the hole doping level of LSMO to induce the interfacial AFM phase. By inserting a thin (1nm) La 0.5 Ca 0.5 MnO 3 layer between BTO and LSMO, the interface magnetic response from LSMO is enhanced. In year two, a non-multiferroic heterostructure SrTiO 3 (STO)/ La 0.5 Ca 0.5 MnO 3 (LCMO)/La 0.67 Sr 0.33 MnO 3 (LSMO) was studied. In this system, the interface FM-AFM transition is observed at negative voltage. The STO layer may act as a hole-donating layer, which induces the hole transfer to LSMO making it overdoped, while the LCMO interlayer at the 0.5 hole doping level displays complicated CE type AFM phase. Thus the AFM phase is dominant at the interface and electron accumulation is required to induce the FM phase by applying a negative voltage. For oxygen rich sample, the magnetic MSHG loop reappears at high positive voltage (around +2.5 V). At high doping level (x > 0.5), LSMO exhibits A-type AFM order, consisting of AFM superexchange coupling between adjacent layers and intralayer FM double-exchange coupling. The less tensile strain of STO and LSMO due to a smaller lattice mismatch as compared to BTO would result in a weaker interlayer coupling . Thus, interfacial A-type AFM order can occur in STO/LCMO/LSMO heterostructure at high hole doping concentration. The study of ME coupling of multifunctional oxide heterostructures is definitely important to the development and performance of future spintronic devices. The results presented here regarding the interfacial magnetic transition controlled by an external electric field offer some new perspective to study the spin transport of magnetic tunnel junctions.

36 MATERIALS SCIENCE↗

Open-Source Data Analysis Tool for Spectral Small-Angle X-ray Scattering Using Spectroscopic Photon-Counting Detector

Spectral small-angle X-ray scattering (sSAXS) is a powerful technique for material characterization from thicker samples by capturing elastic X-ray scattering data in angle- and energy-dispersive modes at small angles. This approach is enabled by the use of a 2D spectroscopic photon-counting detector that provides energy and position information of scattered photons when a sample is irradiated by a polychromatic X-ray beam. Here, we describe an open-source tool with a graphical interface for analyzing sSAXS data obtained from a 2D spectroscopic photon-counting detector with a large number of energy bins. The tool takes system geometry parameters and raw detector data to output 1D scattering patterns and a 2D spatially-resolved scattering map in the energy range of interest. We validated these features using data from samples of caffeine powder with well-known scattering peaks. This open-source tool will facilitate sSAXS data analysis for various material characterization applications.

Chemistry↗

Probing circular polarization and magnetic field structure in active galactic nuclei

The composition and magnetic field morphology of relativistic jets can be studied using circular polarization (CP) measurement. Recent three-dimensional relativistic magnetohydrodynamic (3D RMHD) simulations coupled with radiative transfer (RT) calculations make strong predictions about the level (and morphology) of the jet’s CP emission. These simulations show that the sign of CP and the electric vector position angle (EVPA) are both sensitive to the jet’s magnetic field morphology within the radio core. We probe this theory by exploring whether the jet’s radio core EVPA orientation is consistent with the observed sign of the core CP in deep full-track polarimetric observations. Based on a selection of sources from earlier MOJAVE observations, we aim to probe the nature of linear polarization (LP) and CP in the innermost regions of jets from a small sample of nine blazars. This sample includes sources that have exhibited: (i) positive CP; (ii) negative CP; or (iii) positive and negative CP simultaneously in the radio core region. By coupling deep polarimetric observations of a carefully selected sample of blazars with state-of-the-art RMHD and RT calculations, we hope to gain a deeper understanding of the physics of blazar jets.

79 ASTRONOMY AND ASTROPHYSICS↗

Alignment and position visualization methods for the biomedical imaging and therapy (BMIT) MRT lift

The Microbeam Radiation Therapy (MRT) Lift is an eight stage positioning and scanning system at the Canadian Light Source’s BMIT Facility. Alignment of the sample with the beam using the MRT Lift is a time consuming and challenging task. The BMIT Group has developed a Python-based MRT Lift positioning and control program that uses a combination of computational and iterative methods to independently adjust the sample’s X, Y, Z, pitch and roll positions. The program offers “1-Click” alignment of the sample to the beam. Use of a wireframe visualization technique enables even minute movements to be illustrated. Proposed movements and the resulting MRT Lift position can be manually verified before being applied. Optional integration with the SolidWorks modelling platform allows high quality renderings of the MRT Lift in its current or proposed position to be displayed in real time. Human factors principles are incorporated into the program with the objective of delivering easy to use controls for this complex device.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The utility of ultrasound guidance in transjugular liver biopsy: our experience

Purpose: To demonstrate the utility of ultrasound (US) guidance in improving the safety and efficacy of transjugular liver biopsy (TJLB) by analyzing all the TJLBs performed by us in the last 4 years. Materials and methods: Forty-seven patients who underwent TJLB in the last 4 years in our two centers were retrospectively analyzed. US guidance was used for all but for one patient during the two crucial steps of the procedure—for internal jugular vein (IJV) access and during the parenchymal biopsy. Biopsies were obtained under real-time sonographic guidance from the right lobe after confirming an adequate room for needle throw without breaching the liver capsule or any major hilar structures. Post-procedure complications, tissue yield, and histopathological adequacy of samples were analyzed. Results: Overall technical success rate was 100%. No major complications were found where ultrasound-assisted TJLB (uTJLB) was performed. One patient who underwent non-US guided TJLB had an event of a capsular breach and intra-peritoneal hemorrhage requiring coil embolization. Samples were of adequate dimension. Histopathological positivity was 100%. The overall complication rate for uTJLB was 4.7% which was due to minor complications in two patients. Conclusions: Addition of US unit to the angiographic suite is effortless and Interventional Radiologists being already skilled in US can easily implement this simple yet valuable modification to conventional TJLB procedures. Our experience on uTJLB further emphasizes the role of US guidance in improving the procedural success rate, safety profile, and efficacy in the histopathological outcome of TJLB in all patients irrespective of age and disease burden.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Design and validation of a gamma-ray scanning system for measuring irradiated nuclear fuel

We report a prototype gamma-ray scanning system was designed to perform post-irradiation measurements of nuclear fuel at Idaho National Laboratory (INL). The system is composed of a coaxial high-purity germanium (HPGe) detector, a collimator, and mechanical positioning stages that translate the fuel sample across the front of the collimator. This paper documents the design process, modeling and the laboratory characterization performed to validate the system. The modeling of the system was done using the Monte Carlo N-Particle code with vendor-supplied design specifications, dimensional measurements, and x-ray radiographs of the HPGe detector. The characterization included measurements of calibrated radiation sources in different geometries, and calculations for absolute efficiency and dead time. Benchmark measurements were performed scanning an irradiated fuel rodlet containing ten pellets of 4.9% enriched UO2 in zirconium alloy. These results were compared to simulated spectra to further help characterize the detector model. One goal of the system is to determine the number of fissions per gram of UO2 in the fuel; comparison of the results from this prototype system's assay of the irradiated fuel rodlet are in agreement with previously estimated results.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Correlation between high expression levels of jumonji domain-containing 4 and short survival in cases of colon adenocarcinoma

Highlights: • The play an important role of JMJD4 high expression in tumorgenesis of colon adenocarcinoma. • JMJD4 protein expression in colon adenocarcinoma was associated with histological grade and M-class. • The high expression of JMJD4 was significantly related with poor survival in patients with colon adenocarcinoma. • Cox proportional-hazards model analysis indicated JMJD4 could be a prognostic indicator for overall survival. In this study, we investigated the expression of jumonji domain-containing 4 (JMJD4) in colon adenocarcinoma (CA) look for evidences for future studies on clinical diagnostic and prognostic value. The immunohistochemical (IHC) reactivity of JMJD4 was assessed in human tissue microarrays using monoclonal antibodies. An initial investigation revealed that the expression of JMJD4 protein was significantly higher in tumor tissue of the colon and liver than in normal tissue. Upon further investigation, we observed significant positivity of JMJD4 between 59 paired samples from CA tissue and adjacent normal tissue. JMJD4 protein expression in CA differed significantly according to the histological grade and M-class (distant metastasis). We also determined that the mRNA or protein expression of JMJD4 was significantly associated with poor survival in patients with CA. Finally, univariate and multivariate analysis revealed that JMJD4 expression could be a prognostic indicator for patients with CA and may provide a new target for the development of novel therapies for the treatment of CA.

60 APPLIED LIFE SCIENCES↗

Effect of niobium and phase transformation temperature on the microstructure and texture of a novel 0.40% C thermomechanically processed steel

Field emission scanning electron microscopy, electron backscatter diffraction (EBSD) and X-ray diffraction (XRD) have been employed to investigate the effect of niobium and phase transformation temperature on the evolution of microstructure and texture in a novel thermomechanically processed, medium‑carbon, low-alloy steel intended for slurry pipeline applications. Thermomechanical processing consisted of hot-rolling in the austenitic region with deformation both above the recrystallization limit temperature and below the recrystallization stop temperature. Immediately after rolling, specimens were directly quenched in water to two different temperatures of 560 °C and 420 °C and subsequently furnace cooled from those temperatures to simulate the cooling of coiled strip on a hot strip mill. The microstructure of samples quenched to 560 °C mostly comprised of upper bainite, whereas the samples quenched to 420 °C mainly consisted of lath-type lower bainite. The transformation texture of all samples at the mid-thickness position consisted of α, γ and ε-fibers with high intensities close to the transformed copper, transformed brass and rotated cube components. The addition of 0.013 wt% Nb refined the microstructure and sharpened the texture. The texture of the small fraction of retained austenite present in the final microstructures indicated that the main bcc texture components result from the brass and copper components in the parent austenite.

36 MATERIALS SCIENCE↗

Characterization of a Thermo Scientific D711 D-T neutron generator located in a low-scatter facility

A dosimetry experiment used to measure the neutron flux and spectrum of a D-T neutron generator is presented. The D-T generator at Pacific Northwest National Laboratory is installed in the middle of a large room to minimize scatter of neutrons back to the sample. The efficacy of maintaining a pure fast neutron field for the sample is investigated. Twenty-one positions within 13 cm of the neutron source contained foils or wires of Fe, Ni, Al with additional Au, and In monitors at some locations. Spectral adjustment of the neutron flux at each position based on measured reaction rates and theoretical Monte Carlo calculations show that at least 99.1% of the spectrum lies above 110 keV for all measured positions, and neutrons above 14 MeV can account for as much as 91% at locations along the axis of the generator and close to the source. The 14 MeV component drops to 77% in radial positions far from the source. The largest total flux observed was 8.29E+08 n/cm2-s (±1.4%) in the center of the cooling cap, although additional experiments have shown this value could be as high as 1.20E+09 n/cm2-s.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Superposition Principle in Auger Recombination of Charged and Neutral Multicarrier States in Semiconductor Quantum Dots

Application of colloidal semiconductor quantum dots (QDs) in optical and optoelectronic devices is often complicated by unintentional generation of extra charges, which opens fast nonradiative Auger recombination pathways whereby the recombination energy of an exciton is quickly transferred to the extra carrier(s) and ultimately dissipated as heat. Previous studies of Auger recombination have primarily focused on neutral and, more recently, negatively charged multicarrier states. Auger dynamics of positively charged species remains more poorly explored due to difficulties in creating, stabilizing, and detecting excess holes in the QDs. Here we apply photochemical doping to prepare both negatively and positively charged CdSe/CdS QDs with two distinct core/shell interfacial profiles (“sharp” versus “smooth”). Using neutral and charged QD samples we evaluate Auger lifetimes of biexcitons, negative and positive trions (an exciton with an extra electron or a hole, respectively), and multiply negatively charged excitons. Using these measurements, we demonstrate that Auger decay of both neutral and charged multicarrier states can be presented as a superposition of independent elementary three-particle Auger events. As one of the manifestations of the superposition principle, we observe that the biexciton Auger decay rate can be presented as a sum of the Auger rates for independent negative and positive trion pathways. Furthermore, by comparing the measurements on the QDs with the “sharp” versus “smooth” interfaces, we also find that while affecting the absolute values of Auger lifetimes, manipulation of the shape of the confinement potential does not lead to violation of the superposition principle, which still allows us to accurately predict the biexciton Auger lifetimes based on the measured negative and positive trion dynamics. Our findings indicate considerable robustness of the superposition principle as applied to Auger decay of charged and neutral multicarrier states, suggesting its generality to quantum-confined nanocrystals of arbitrary compositions and complexities.

36 MATERIALS SCIENCE↗

Calibration of measurement sensitivities of multiple micro-cantilever dynamic modes in atomic force microscopy using a contact detection method

An accurate experimental method is proposed for on-spot calibration of the measurement sensitivities of multiple micro-cantilever dynamic modes in atomic force microscopy. One of the key techniques devised for this method is a reliable contact detection mechanism that detects the tip-surface contact instantly. At the contact instant, the oscillation amplitude of the tip deflection, converted to that of the deflection signal in laser reading through the measurement sensitivity, exactly equals to the distance between the sample surface and the cantilever base position. Therefore, the proposed method utilizes the recorded oscillation amplitude of the deflection signal and the base position of the cantilever at the contact instant for the measurement sensitivity calibration. Experimental apparatus along with various signal processing and control modules was realized to enable automatic and rapid acquisition of multiple sets of data, with which the calibration of a single dynamic mode could be completed in less than 1 s to suppress the effect of thermal drift and measurement noise. Calibration of the measurement sensitivities of the first and second dynamic modes of three micro-cantilevers having distinct geometries was successfully demonstrated. The dependence of the measurement sensitivity on laser spot location was also experimentally investigated. Finally, an experiment was performed to validate the calibrated measurement sensitivity of the second dynamic mode of a micro-cantilever.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

KrF- and ArF-excimer-laser-induced absorption in silica glasses produced by melting synthetic silica powder

KrF- and ArF-excimer-laser-induced absorption of silica glasses produced by electric melting and flame fusion of synthetic silica powder were investigated. The growth of KrF-laser-induced absorption was more gradual than that of ArF-laser-induced absorption. Induced absorption spectra exhibited a peak at about 5.8 eV, of which the position and width differed slightly among samples and laser species. Widths of ArF-laser-induced absorption spectra were wider than those of KrF-laser-induced spectra. KrF-laser-induced absorption is reproducible by two Gaussian absorption bands peaking at 5.80 eV with full width at half maximum (FWHM) of 0.62 eV and at 6.50 eV with FWHM of 0.74 eV. For reproduction of ArF-laser-induced absorption, Gaussian bands at 5.41 eV with FWHM of 0.62 eV was necessary in addition to components used for reproducing KrF-laser-induced absorption. Based on the discussion of the change of defect structures evaluated from change of absorption components, we proposed that the precursor of the 5.8-eV band ascribed to E Prime center ({identical_to}Si{center_dot}) is {identical_to}Si-H HO-Si{identical_to} structures formed by the reaction between strained Si-O-Si bonds and interstitial H{sub 2} molecules during the irradiation.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

An investigation of low temperature electronic phase arrest in Sm{sub 0.55}Sr{sub 0.45}MnO{sub 3} phase separated manganite

The temperature dependence of electronic-transport and magneto-transport of polycrystalline Sm{sub 0.55}Sr{sub 0.45}MnO{sub 3} manganite at low temperatures has been investigated in detail. The low temperature resistivity data show a distinct minimum in the resistivity versus temperature plots for all fields. The low temperature resistivity upturn below this minimum has been fitted to an expression, which includes three terms, namely, residual resistivity, inelastic scattering, and electron-electron (e-e) interaction or Kondo effects. It has been found that the dominating mechanism is e-e interaction. The resistivity of the sample shows strong dependence on the magnetic field–temperature history. The electronic-transport property clearly confirms that the electronic phase of the sample gets arrested to a low resistive state during field cooling and cannot return to its original state even after the magnetic field is removed. The magnetoresistance of the sample also shows a strong irreversibility with respect to the sweeping of the magnetic field between its highest positive and negative values. Moreover, the resistivity of the sample is found to be time dependent. All the observed phenomena have been explained through the phase separation scenario and kinetic arrest of electronic phase.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Active laser ranging with frequency transfer using frequency comb

A comb-based active laser ranging scheme is proposed for enhanced distance resolution and a common time standard for the entire system. Three frequency combs with different repetition rates are used as light sources at the two ends where the distance is measured. Pulse positions are determined through asynchronous optical sampling and type II second harmonic generation. Results show that the system achieves a maximum residual of 379.6 nm and a standard deviation of 92.9 nm with 2000 averages over 23.6 m. Moreover, as for the frequency transfer, an atom clock and an adjustable signal generator, synchronized to the atom clock, are used as time standards for the two ends to appraise the frequency deviation introduced by the proposed system. The system achieves a residual fractional deviation of 1.3 × 10{sup −16} for 1 s, allowing precise frequency transfer between the two clocks at the two ends.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

SwissFEL instrument ESB femtosecond pump-probe diffraction and scattering

The ESB instrument at the SwissFEL ARAMIS hard X-ray free electron laser is designed to perform pump-probe experiments in condensed matter and material science employing photon-in and photon-out techniques. It includes a femtosecond optical laser system to generate a variety of pump beams, a X-ray optical scheme to tailor the X-ray probe beam, shot-to-shot diagnostics to monitor the X-ray intensity and arrival time, and two endstations operated at a single focus position that include multi-purpose sample environments and 2D pixel detectors for data collection.

43 PARTICLE ACCELERATORS↗