Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Resonator”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 793 records · Page 44

Microscopic Modeling of Intersubband Resonances in InAs/AlSb Quantum Wells

Linear absorption spectra from intersubband resonance in InAs/AlSb quantum wells are analyzed theoretically using the intersubband semiconductor Bloch equation approach. Our model goes beyond the Hartree-Fock approximation and treats particle-particle correlations under the second Born approximation. Electron-electron and -LO phonon scatterings from such a treatment describe intrinsic line broadening to the intersubband resonance. Electron subbands are determined self-consistently with a spurious-state-free 8-band k.p Hamiltonian under the envelope function approximation. To compare with experimental measurements, we also included line broadening due to electron-interface roughness scattering. Excellent agreement was achieved for temperature-dependent absorption spectra in the mid-infrared frequency range, after taking into careful account the interplay of material parameters, nonparabolicity in bandstructure, and many-body effects.

Li, Jian-Zhong↗

Development of Laser-Polarized Noble Gas Magnetic Resonance Imaging (MRI) Technology

We are developing technology for laser-polarized noble gas nuclear magnetic resonance (NMR), with the aim of enabling it as a novel biomedical imaging tool for ground-based and eventually space-based application. This emerging multidisciplinary technology enables high-resolution gas-space magnetic resonance imaging (MRI)-e.g., of lung ventilation, perfusion, and gas-exchange. In addition, laser-polarized noble gases (3He and 1BXe) do not require a large magnetic field for sensitive NMR detection, opening the door to practical MRI with novel, open-access magnet designs at very low magnetic fields (and hence in confined spaces). We are pursuing two specific aims in this technology development program. The first aim is to develop an open-access, low-field (less than 0.01 T) instrument for MRI studies of human gas inhalation as a function of subject orientation, and the second aim is to develop functional imaging of the lung using laser-polarized He-3 and Xe-129.

Walsworth, Ronald L.↗

Coherence Effects in Coupled Optical Resonators

The coherent coupling between optical resonators leads to an effect analogous to lasing without inversion. In addition, lasing thresholds can be substantially decreased through the use of coupled resonators provided they are properly phased.

Smith, David D.↗

The Geometry of Resonant Signatures in Debris Disks with Planets

Using simple geometrical arguments, we paint an overview of the variety of resonant structures a single planet with moderate eccentricity (e<approx.0.6) can create in a dynamically cold, optically thin dust disk. This overview may serve as a key for interpreting images of perturbed debris disks and inferring the dynamical properties of the planets responsible for the perturbations. We compare the resonant geometries found in the solar system dust cloud with observations of dust clouds around Vega, Epsilon Eridani, and Fomalhaut.

Kuchner, Marc J.↗

Identification of Cyclically Symmetric Resonance in Experimental Data for Engine Failure Analysis

Many structural components are rotationally symmetric. For a perfectly manufactured structure, the modal wave shapes are exactly sinusoidal. These structures can be excited by similarly-shaped forcing functions such as those found frequently in or near turbomachinery. Due to orthogonality, resonance occurs only when the integer wave number of the structure equals the integer wave number of the excitation as well as when the excitation frequency is close to the natural frequency of the mode. This resonance can lead to high-cycle fatigue (HCF) cracking of the structure. To help understand this phenomenon, it is desirable to determine the modal composition of the response and excitation. Once the modal composition is known, either the excitation or the structure can be modified to reduce the response and therefore prevent HCF cracking.

Medley, Steve↗

Transonic Resonance Demonstrated To Be a Source of Internal Noise From Mixer-Ejector Nozzles

During noise field studies with mixer-ejector nozzles in NASA's High-Speed Research program, tones were often encountered. The tones would persist in the simulated "cutback" condition (shortly after takeoff). Unfortunately, we did not understand their origin and, thus, could not develop a logical approach for suppressing them. We naturally questioned whether or not some of those tones were due to the transonic resonance. This was studied with a 1/13th scale model of the High-Speed Civil Transport nozzle. The first objective was to determine if indeed tones could be detected in the radiated noise. The next objective was to diagnose if those tones were due to the transonic resonance. Agreement of the frequencies with the correlation equation and the effect of boundary layer tripping were to be used in the diagnosis.

Zaman, Khairul B.↗

Polynomial Expressions for Estimating Elastic Constants From the Resonance of Circular Plates

Two approaches were taken to make convenient spread sheet calculations of elastic constants from resonance data and the tables in ASTM C1259 and E1876: polynomials were fit to the tables; and an automated spread sheet interpolation routine was generated. To compare the approaches, the resonant frequencies of circular plates made of glass, hardened maraging steel, alpha silicon carbide, silicon nitride, tungsten carbide, tape cast NiO-YSZ, and zinc selenide were measured. The elastic constants, as calculated via the polynomials and linear interpolation of the tabular data in ASTM C1259 and E1876, were found comparable for engineering purposes, with the differences typically being less than 0.5 percent. Calculation of additional v values at t/R between 0 and 0.2 would allow better curve fits. This is not necessary for common engineering purposes, however, it might benefit the testing of emerging thin structures such as fuel cell electrolytes, gas conversion membranes, and coatings when Poisson s ratio is less than 0.15 and high precision is needed.

Salem, Jonathan A.↗

Investigation of Gas Effects on Cryocooler Resonance Characteristics

Cryocooler thermal and vibrational performance is determined, fundamentally, by the dynamic interactions between the mechanical system and the working fluid. This paper explores the effect of working-fluid characteristics on the mechanical response of the cooler. Experimental data collected from two coolers characterized under the Jet Propulsion Laboratory's extensive program of cryocooler testing and characterization show that a classical single-degree-of-freedom spring-mass-damper model does not capture the full frequency dependence of the mechanical response. The data from the two modes of cooler operation (slosh and head-to-head) are used to motivate the explanation that working-fluid characteristics dominate at high frequencies, and mechanical system characteristics dominate at lower frequencies. Operating temperature is shown to be a significant factor in determining resonance behavior. Finally, the discussion provides a framework within which resonate parameters and cooler characteristics can be extracted from the experimental data.

cryocooler vibration working-fluid characteristics↗

Theory of electrically controlled resonant tunneling spin devices

We report device concepts that exploit spin-orbit coupling for creating spin polarized current sources using nonmagnetic semiconductor resonant tunneling heterostructures, without external magnetic fields. The resonant interband tunneling psin filter exploits large valence band spin-orbit interaction to provide strong spin selectivity.

spin filters↗

EIT in resonator chains: similarities and differences with atomic media

We theoretically study a parallel configuration of two interacting whispering gallery mode optical resonators and show a narrow-band modal structure as a basis for a widely tunable delay line. For the optimum coupling configuration the system can possess an unusually narrow spectral feature with a much narrower bandwidth than the loaded bandwidth of each individual resonator.

electromagnetically induced transparency↗

Isolated post resonator mesogyroscope

A new symmetric vibratory gyroscope principle has been devised in which a central post proof mass is counter-rocked against an outer sensing plate such that the motion is isolated from the gyroscope case. Prototype gyroscopes have been designed and fabricated with micromachined silicon at mesoscale (20-cm resonator width), vs. microscale (e.g., 2-mm resonator width) to achieve higher sensitivity and machined precision. This novel mesogyro design arose out of an ongoing technical cooperation between JPL and Boeing begun in 1997 to advance the design of micro-inertial sensors for low-cost space applications. This paper describes the theory of operation of the mesogyro and relationships with other vibratory gyroscopes, the mechanical design, closed loop electronics design, bulk silicon fabrication and packaged gyroscope assembly and test methods. The initial packaged prototype test results are reported for what is believed to be the first silicon mesogyroscope.

mesogyroscope↗

Accurate Cross Sections for Excitation of Resonance Transitions in Atomic Oxygen

Electron collision excitation cross sections for the resonance 2p(sup)4 (sup 3)P-2p(sup 3)3s (sup 3)S(sup 0), 2p(sup 4) (sup 3)P-2p(sup 3)3d (sup 3)D(sup 0), 2p4 (sup 3)P-2p(sup 3)3s (sup 3)D(sup 0), 2p(sup 4) (sup 3)P-2p(sup 3)3s (sup 3)P(sup 0) and 2p(sup 4) (sup 3)P-2s2p(sup 5) (sup 3)P(sup 0) transitions have been calculated by using the R matrix with a pseudostates approach for incident electron energies from near threshold to 100 eV. The excitation of these transition sgives rise to strong atomic oxygen emission features at 1304, 1027, 989, 878, and 792 Angstrom in the spectra of several planetary atmospheres. We included 22 spectroscopic bound and autoionizing states and 30 pseudostates in the close-coupling expansion. The target wave functions are chosen to properly account for the important correlation and relaxation effects. The effect of coupling to the continuum is included through the use of pseudostates. The contribution of the ionization continuum is significant for resonance transitions. Measured absolute direct excitation cross sections of 0 I are reported by experimental groups from the Jet Propulsion Laboratory and Johns Hopkins University. Good agreement is noted for the 2p(sup)4 (sup 3)P-2p(sup 3)3s (sup 3)S(sup 0) transition (lambda 1304 Ang) with measured cross sections from both groups that agree well with each other. There is disagreement between experiments for other transitions. Our results support the measured cross sections from the Johns Hopkins University for the 2p(sup 4) (sup 3)P-2p(sup 3)3d (sup 3)D(sup 0) and 2p4 (sup 3)P-2p(sup 3)3s (sup 3)D(sup 0) transitions, while for the 2p4 (sup 3)P-2p(sup 3)3s (sup 3)D(sup 0) transition the agreement is switched to the measured cross sections from the Jet Propulsion Laboratory.

Tayal, S. S.↗

On the Mutual Coupling Between Circular Resonant Slots

For near- and far-field microwave imaging purposes, array of circular resonant slots can be utilized to sample the electric field at a given reference plane. In general, the sensitivity of such array probes is impaired by the mutual coupling present between the radiating elements. The mutual coupling problem poses a design tradeoff between the resolution of the array and its sensitivity. In this paper, we investigate the mutual coupling between circular resonant slots in conducting ground plane both numerically and experimentally. Based on the analysis of the dominant coupling mechanism, i.e., the surface currents, various remedies to reduce the slots' mutual coupling are proposed and verified.

Abou-Khousa, M. A.↗

On the Mutual Coupling between Circular Resonant Slots

For near- and far-field microwave imaging purposes, array of circular resonant slots can be utilized to sample the electric field at a given reference plane. In general, the sensitivity of such an array is impaired by the existing mutual coupling between the radiating elements or in this case circular slots. The mutual coupling problem imposes a design tradeoff between the resolution of the array and the overall system sensitivity and dynamic range. In this paper, the mutual coupling between circular resonant slots in conducting ground plane is investigated both numerically and experimentally. In particular, the mutual coupling in the E- and H-plane configurations of two identical slots is studied.

Abou-Khousa, M. A.↗

Split-resonator integrated-post MEMS gyroscope

A split-resonator integrated-post vibratory microgyroscope may be fabricated using micro electrical mechanical systems (MEMS) fabrication techniques. The microgyroscope may include two gyroscope sections bonded together, each gyroscope section including resonator petals, electrodes, and an integrated half post. The half posts are aligned and bonded to act as a single post.

Bae, Youngsam↗

Active noise control using noise source having adaptive resonant frequency tuning through variable ring loading

A noise source for an aircraft engine active noise cancellation system in which the resonant frequency of noise radiating structure is tuned to permit noise cancellation over a wide range of frequencies. The resonant frequency of the noise radiating structure is tuned by a plurality of drivers arranged to contact the noise radiating structure. Excitation of the drivers causes expansion or contraction of the drivers, thereby varying the edge loading applied to the noise radiating structure. The drivers are actuated by a controller which receives input of a feedback signal proportional to displacement of the noise radiating element and a signal corresponding to the blade passage frequency of the engine's fan. In response, the controller determines a control signal which is sent to the drivers, causing them to expand or contract. The noise radiating structure may be either the outer shroud of the engine or a ring mounted flush with an inner wall of the shroud or disposed in the interior of the shroud.

Pla, Frederic G.↗