Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Reads”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 793 records · Page 44

Prevalence and variability in reporting of clinically actionable incidental findings on attenuation-correction CT scans in a veteran population

Background: Myocardial perfusion imaging (MPI) often employs attenuation-correction computed tomography (CTAC) to reduce attenuation artifacts and improve specificity. While there is no specific guideline on how they should be reported, incidental noncardiac findings identified on these scans may be clinically significant. The prevalence of these findings in veterans is not currently known. In addition, variability in reporting these findings may depend on the interpreting physician’s specialty. Methods: To guide future decision-making, CTACs in veterans referred for MPI were prospectively evaluated in a quality-control project for a set of prespecified actionable incidental findings by cardiologists and a radiologist. Results: On the 771 scans performed over eight months, 285 incidental noncardiac findings were identified by the interpreting cardiologists and 378 were identified by the interpreting radiologist. Pulmonary nodules were the most common occurring in 20% of studies read by the radiologist. Interreader agreements between cardiologists and the radiologist were poor for pulmonary nodules ≥ 10 mm and hiatal hernias; fair for pulmonary nodules < 10 mm, extracardiac masses, and aortic aneurysms; and moderate for pleural plaques. Conclusion: Incidental noncardiac findings on CTACs are common in our veteran population. Overall interobserver agreement in identifying these findings between cardiologists and radiologists is fair. Specific guidelines are needed on how CTACs should be read and reported.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Interferometry of non-Abelian anyons

We develop the general quantum measurement theory of non-Abelian anyons through interference experiments. The paper starts with a terse introduction to the theory of anyon models, focusing on the basic formalism necessary to apply standard quantum measurement theory to such systems. This is then applied to give a detailed analysis of anyonic charge measurements using a Mach-Zehnder interferometer for arbitrary anyon models. We find that, as anyonic probes are sent through the legs of the interferometer, superpositions of the total anyonic charge located in the target region collapse when they are distinguishable via monodromy with the probe anyons, which also determines the rate of collapse. We give estimates on the number of probes needed to obtain a desired confidence level for the measurement outcome distinguishing between charges, and explicitly work out a number of examples for some significant anyon models. We apply the same techniques to describe interferometry measurements in a double point-contact interferometer realized in fractional quantum Hall systems. To lowest order in tunneling, these results essentially match those from the Mach-Zehnder interferometer, but we also provide the corrections due to processes involving multiple tunnelings. Finally, we give explicit predictions describing state measurements for experiments in the Abelian hierarchy states, the non-Abelian Moore-Read state at {nu}=5/2 and Read-Rezayi state at {nu}=12/5.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Simultaneous cloning and expression of two cellulase genes from Bacillus subtilis newly isolated from Golden Takin (Budorcas taxicolor Bedfordi)

A bacterial strain with high cellulase activity was isolated of feces sample of Golden Takin (Budorcas taxicolor Bedfordi). The bacterium was classified and designated Bacillus subtilis LN by morphological and 16SrDNA gene sequence analysis. Two putative cellulase genes, CelL15 and CelL73, were simultaneously cloned from the isolated strain by PCR. The putative gene CelL15 consisted of an open reading frame (ORF) of 1470 nucleotides and encoded a protein of 490 amino acids with a molecular weight of 54 kDa. The CelL73 gene consisted of an open reading frame (ORF) of 741 nucleotides and encoded a protein of 247 amino acids with a molecular weight of 27 kDa. Both genes were purified and cloned into pET-28a for expression in Escherichia coli BL21 (DE3). The ability of E. coli to degrade cellulose was enhanced when the two recombinants were cultured together.

60 APPLIED LIFE SCIENCES↗

Reducing Disk Storage of Full-3D Seismic Waveform Tomography (F3DT) Through Lossy Online Compression

Full-3D seismic waveform tomography (F3DT) is the latest seismic tomography technique that can assimilate broadband, multi-component seismic waveform observations into high-resolution 3D subsurface seismic structure models. The main drawback in the current F3DT implementation, in particular the scattering-integral implementation (F3DT-SI), is the high disk storage cost and the associated I/O overhead of archiving the 4D space-time wavefields of the receiver- or source-side strain tensors. The strain tensor fields are needed for computing the data sensitivity kernels, which are used for constructing the Jacobian matrix in the Gauss-Newton optimization algorithm. In this study, we have successfully integrated a lossy compression algorithm into our F3DT SI workflow to significantly reduce the disk space for storing the strain tensor fields. The compressor supports a user-specified tolerance for bounding the error, and can be integrated into our finite-difference wave-propagation simulation code used for computing the strain fields. The decompressor can be integrated into the kernel calculation code that reads the strain fields from the disk and compute the data sensitivity kernels. During the wave-propagation simulations, we compress the strain fields before writing them to the disk. To compute the data sensitivity kernels, we read the compressed strain fields from the disk and decompress them before using them in kernel calculations. Experiments using a realistic dataset in our California statewide F3DT project have shown that we can reduce the strain-field disk storage by at least an order of magnitude with acceptable loss, and also improve the overall I/O performance of the entire F3DT-SI workflow significantly. The integration of the lossy online compressor may potentially open up the possibilities of the wide adoption of F3DT-SI in routine seismic tomography practices in the near future.

97 MATHEMATICS AND COMPUTING↗

Atmospheric Pressure Surface Sampling/Ionization Techniques for Direct Coupling of Planar Separations with Mass Spectrometry

Planar separations, which include thin layer chromatography and gel electrophoresis, are in widespread use as important and powerful tools for conducting separations of complex mixtures. To increase the utility of planar separations, new methods are needed that allow in-situ characterization of the individual components of the separated mixtures. A large number of atmospheric pressure surface sampling and ionization techniques for use with mass spectrometry have emerged in the past several years, and several have been investigated as a means for mass spectrometric read-out of planar separations. In this article, we review the atmospheric pressure surface sampling and ionization techniques that have been used for the read-out of planar separation media. For each technique, we briefly explain the operational basics and discuss the analyte type for which it is appropriate and some specific applications from the literature.

Atmospheric Pressure Surface Sampling↗

Using the tabulated diffusion flamelet model ADF-PCM to simulate a lifted methane-air jet flame

Two formulations of a turbulent combustion model based on the approximated diffusion flame presumed conditional moment (ADF-PCM) approach [J.-B. Michel, O. Colin, D. Veynante, Combust. Flame 152 (2008) 80-99] are presented. The aim is to describe autoignition and combustion in nonpremixed and partially premixed turbulent flames, while accounting for complex chemistry effects at a low computational cost. The starting point is the computation of approximate diffusion flames by solving the flamelet equation for the progress variable only, reading all chemical terms such as reaction rates or mass fractions from an FPI-type look-up table built from autoigniting PSR calculations using complex chemistry. These flamelets are then used to generate a turbulent look-up table where mean values are estimated by integration over presumed probability density functions. Two different versions of ADF-PCM are presented, differing by the probability density functions used to describe the evolution of the stoichiometric scalar dissipation rate: a Dirac function centered on the mean value for the basic ADF-PCM formulation, and a lognormal function for the improved formulation referenced ADF-PCM{chi}. The turbulent look-up table is read in the CFD code in the same manner as for PCM models. The developed models have been implemented into the compressible RANS CFD code IFP-C3D and applied to the simulation of the Cabra et al. experiment of a lifted methane jet flame [R. Cabra, J. Chen, R. Dibble, A. Karpetis, R. Barlow, Combust. Flame 143 (2005) 491-506]. The ADF-PCM{chi} model accurately reproduces the experimental lift-off height, while it is underpredicted by the basic ADF-PCM model. The ADF-PCM{chi} model shows a very satisfactory reproduction of the experimental mean and fluctuating values of major species mass fractions and temperature, while ADF-PCM yields noticeable deviations. Finally, a comparison of the experimental conditional probability densities of the progress variable for a given mixture fraction with model predictions is performed, showing that ADF-PCM{chi} reproduces the experimentally observed bimodal shape and its dependency on the mixture fraction, whereas ADF-PCM cannot retrieve this shape. (author)

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

On the formulation of species reaction rates in the context of multi-species CFD codes using complex chemistry tabulation techniques

In the standard implementation of tabulated combustion models of the FPI or FGM type, the mean species mass fractions are read from look-up tables as functions of a progress variable, mixture fraction and their variances. In multi-species CFD codes however, the mean thermodynamic properties are deduced from the local mean species mass fractions. The unclosed mean source terms appearing in the latter's transport equations must then be given by the chemistry look-up tables. Two possible formulations for this mean source terms are discussed and compared in the present paper. In the reaction rate (RR) formulation, all mean reaction rates are directly read from a look-up table. In the mass fraction (MF) formulation, only the reaction rate for the progress variable is stored, and mean species source terms are constructed to relax the mean mass fractions towards the value stored in the look-up table. After a detailed description of in particular the MF formulation, simple a priori tests of auto-igniting reactors without convection and diffusion are used to illustrate and discuss the differences between the two formulations. Both formulations are then applied to a RANS simulation of the Cabra et al. burner in the context of a PCM-FPI and of an ADF-PCM model. The reported findings confirm the conclusions from the simple tests, highlighting the definitive advantages of the MF formulation. It ensures an accurate reproduction of auto-ignition delays, species evolutions and equilibriums, at the condition that the relaxation parameter is of the order of a characteristic chemical time. Finally, it is shown that the relaxation's effect is only a second order correction. (author)

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

MechElastic: A Python library for analysis of mechanical and elastic properties of bulk and 2D materials

We report the MechElastic Python package evaluates the mechanical and elastic properties of bulk and 2D materials using the elastic coefficient matrix ( C ij ) obtained from any ab-initio density-functional theory (DFT) code. The current version of this package reads the output of VASP, ABINIT, and Quantum Espresso codes (but it can be easily generalized to any other DFT code) and performs the appropriate post-processing of elastic constants as per the requirement of the user. This program can also detect the input structure's crystal symmetry and test the mechanical stability of all crystal classes using the Born-Huang criteria. Various useful material-specific properties such as elastic moduli, longitudinal and transverse elastic wave velocities, Debye temperature, elastic anisotropy, 2D layer modulus, hardness, Pugh's ratio, Cauchy's pressure, Kleinman's parameter, and Lame's coefficients, can be estimated using this program. Another existing feature of this program is to employ the ELATE package (2016) [29] and plot the spatial variation of several elastic properties such as Poisson's ratio, linear compressibility, shear modulus, and Young's modulus in three dimensions. Further, the MechElastic package can plot the equation of state (EOS) curves for energy and pressure for a variety of EOS models such as Murnaghan, Birch, Birch-Murnaghan, and Vinet, by reading the inputted energy/pressure versus volume data obtained via numerical calculations or experiments. This package is particularly useful for the high-throughput analysis of elastic and mechanical properties of materials.

2D materials↗

Anaerobic fungi contain abundant, diverse, and transcriptionally active Long Terminal Repeat retrotransposons

Long Terminal Repeat (LTR) retrotransposons are a class of repetitive elements that are widespread in the genomes of plants and many fungi. LTR retrotransposons have been associated with rapidly evolving gene clusters in plants and virulence factor transfer in fungal-plant parasite-host interactions. We report here the abundance and transcriptional activity of LTR retrotransposons across several species of the early-branching Neocallimastigomycota, otherwise known as the anaerobic gut fungi (AGF). The ubiquity of LTR retrotransposons in these genomes suggests key evolutionary roles in these rumen-dwelling biomass degraders, whose genomes also contain many enzymes that are horizontally transferred from other rumen-dwelling prokaryotes. Up to 10% of anaerobic fungal genomes consist of LTR retrotransposons, and the mapping of sequences from LTR retrotransposons to transcriptomes shows that the majority of clusters are transcribed, with some exhibiting expression greater than 104 reads per kilobase million mapped reads (rpkm). Many LTR retrotransposons are strongly differentially expressed upon heat stress during fungal cultivation, with several exhibiting a nearly three-log10 fold increase in expression, whereas growth substrate variation modulated transcription to a lesser extent. We show that some LTR retrotransposons contain carbohydrate-active enzymes (CAZymes), and the expansion of CAZymes within genomes and among anaerobic fungal species may be linked to retrotransposon activity. We further discuss how these widespread sequences may be a source of promoters and other parts towards the bioengineering of anaerobic fungi.

Genetics & Heredity↗

Advances in fast 2D camera data handling and analysis on NSTX

The use of fast 2D cameras on NSTX continues to grow. There are 6 cameras with the capability of taking up to 1–2 gigabytes (GBs) of data apiece during each plasma shot on the National Spherical Torus Experiment (NSTX). Efficient storage and retrieval of this data remains a challenge. Performance comparisons are presented for reading data stored in MDSplus, using both compressed data and segmented records, and direct access I/O with different read sizes. Encouragingly, fast 2D camera data provides considerable insight into plasma complexities, such as small-scale turbulence and particle transport. The last part of this paper is an example of more recent uses: dual cameras looking at the same region of the plasma from different angles, which can provide trajectories of incandescent particles in 3D. A laboratory simulation of the 3D trajectories is presented, as well as corresponding data from NSTX plasma where glowing dust particles can be followed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Implementation and verification of PyNE R2S with DAG-OpenMC

The mesh-based Rigorous-Two-Step (R2S) method has been widely used in the accurate estimation of the shutdown dose rate (SDR) of fusion systems. Several mesh-based R2S code has been implemented based on Monte Carlo particle transport code MCNP5 or DAG-MCNP5 and inventory calculation code such as FISPACT-II, ALARA or ACAB. Recently, the OpenMC, a community-developed Monte Carlo particle transport code, implemented the photon particle transport capability, which enables OpenMC to be used in R2S. In this paper, PyNE R2S is extended with the support of DAG-OpenMC, i.e., OpenMC with DAGMC. Modifications that allow PyNE to read the flux result in the state point file of OpenMC has been implemented to PyNE R2S workflow. A custom source routine of OpenMC that reads the photon source file from PyNE R2S and sampling photon particle in OpenMC photon transport has been implemented in OpenMC. With these modifications, PyNE R2S is now capable of performing R2S calculations with both DAG-MCNP5 and DAG-OpenMC. The ITER FNG dose rate benchmark problem has been used to validate the code. The FNG neutron source has been modified for neutron transport with DAG-OpenMC. The shutdown dose rate of 19 cooling times has been calculated and compared with the experimental data and the computational results of other R2S codes. The results of PyNE R2S with DAG-OpenMC show satisfactory agreement with the experimental data and other computational results. Therefore, we consider PyNE R2S with DAG-OpenMC is a reliable code to calculate the SDR of fusion systems.

fusion↗

Radiation Changes Do Not Interfere With Postchemoradiation Restaging of Patients With Rectal Cancer by FDG PET/CT Before Curative Surgical Therapy

Purpose: Changes in F-18 fluorodeoxyglucose (FDG) uptake in normal tissues after chemoradiation therapy (CRT) potentially limit the ability of positron emission tomography (PET) to provide early assessment of therapeutic response. This study evaluated whether such changes negatively impact interpretation of posttherapy PET performed within 6 weeks of CRT completion and before definitive surgery in patients with locally advanced rectal cancer. The positive predictive value (PPV) and specificity of post-CRT PET, read clinically, was determined in 63 consecutive rectal cancer patients who had undergone preoperative CRT. Methods and Materials: A schema for identifying and scoring postradiation effects on PET was prospectively defined and applied in a blinded manner. This was compared with initial clinical reporting of response. Histologic assessment of the operative specimens was used as the reference standard. Correlation between clinical proctitis during CRT and radiation changes on subsequent PET was also assessed. Results: Clinical reporting of post-CRT PET yielded a high PPV (94%; 95% confidence interval, 89--100%) but may have been exaggerated by the low prevalence of complete tumor clearance (16%). The specificity was 80% with only two false-positive results. On blinded reading, significant post-CRT effects on PET were recorded in 4 of 63 patients (6% 95% confidence interval, 0-13%), but pattern recognition converted both false-positive PET results to a complete metabolic response. Clinical CRT proctitis was not correlated with PET findings. Conclusion: Postradiation effects do not appear to significantly compromise the interpretation of PET for therapeutic response assessment. The proposed PET pattern of response may further improve the specificity of PET.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Toward a Real-Time In Vivo Dosimetry System Using Plastic Scintillation Detectors

Purpose: In the present study, we have presented and validated a plastic scintillation detector (PSD) system designed for real-time multiprobe in vivo measurements. Methods and Materials: The PSDs were built with a dose-sensitive volume of 0.4 mm{sup 3}. The PSDs were assembled into modular detector patches, each containing five closely packed PSDs. Continuous dose readings were performed every 150 ms, with a gap between consecutive readings of <0.3 ms. We first studied the effect of electron multiplication. We then assessed system performance in acrylic and anthropomorphic pelvic phantoms. Results: The PSDs were compatible with clinical rectal balloons and were easily inserted into the anthropomorphic phantom. With an electron multiplication average gain factor of 40, a twofold increase in the signal/noise ratio was observed, making near real-time dosimetry feasible. Under calibration conditions, the PSDs agreed with the ion chamber measurements to 0.08%. Precision, evaluated as a function of the total dose delivered, ranged from 2.3% at 2 cGy to 0.4% at 200 cGy. Conclusion: Real-time PSD measurements are highly accurate and precise. These PSDs can be mounted onto rectal balloons, transforming these clinical devices into in vivo dose detectors without modifying current clinical practice. Real-time monitoring of the dose delivered near the rectum during prostate radiotherapy should help radiation oncologists protect this sensitive normal structure.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Evaluation of Field-in-Field Technique for Total Body Irradiation

Purpose: To evaluate the clinical use of a field-in-field (FIF) technique for total body irradiation (TBI) using a treatment-planning system (TPS) and to verify TPS results with in vivo dose measurements using metal-oxide-semiconductor field-effect transistor (MOSFET) detectors. Methods and Materials: Clinical and dosimetric data of 10 patients treated with TBI were assessed. Certain radiation parameters were measured using homogenous and regular phantoms at an extended distance of 380 cm, and the results were compared with data from a conventional standard distance of 100 cm. Additionally, dosimetric validation of TPS doses was performed with a Rando phantom using manual calculations. A three-dimensional computed tomography plan was generated involving 18-MV photon beams with a TPS for both open-field and FIF techniques. The midline doses were measured at the head, neck, lung, umbilicus, and pelvis for both open-field and FIF techniques. Results: All patients received planned TBI using the FIF technique with 18-MV photon energies and 2 Gy b.i.d. on 3 consecutive days. The difference in tissue maximum ratios between the extended and conventional distances was <2%. The mean deviation of manual calculations compared with TPS data was +1.6% (range, 0.1-2.4%). A homogenous dose distribution was obtained with 18-MV photon beams using the FIF technique. The mean lung dose for the FIF technique was 79.2% (9.2 Gy; range, 8.8-9.7 Gy) of the prescribed dose. The MOSFET readings and TPS doses in the body were similar (percentage difference range, -0.5% to 2.5%) and slightly higher in the shoulder and lung (percentage difference range, 4.0-5.5%). Conclusion: The FIF technique used for TBI provides homogenous dose distribution and is feasible, simple, and spares time compared with more-complex techniques. The TPS doses were similar to the midline doses obtained from MOSFET readings.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Effect of Cerebellum Radiation Dosimetry on Cognitive Outcomes in Children With Infratentorial Ependymoma

Purpose: Cognitive decline is a recognized effect of radiation therapy (RT) in children treated for brain tumors. The importance of the cerebellum and its contribution to cognition have been recognized; however, the effect of RT on cerebellum-linked neurocognitive deficits has yet to be explored. Methods and Materials: Seventy-six children (39 males) at a median 3.3 years of age (range, 1-17 years old) were irradiated for infratentorial ependymoma from 1997 to 2008. The total prescribed dose was 54 to 59.4 Gy administered to the postoperative tumor bed with 5- or 10-mm clinical target volume margin. Age-appropriate cognitive and academic testing was performed prior to the start of RT and was then repeated at 6 months and annually throughout 5 years. The anterior and posterior cerebellum and other normal brain volumes were contoured on postcontrast, T1-weighted postoperative magnetic resonance images registered to treatment planning computed tomography images. Mean doses were calculated and used with time after RT and other clinical covariates to model their effect on neurocognitive test scores. Results: Considering only the statistically significant rates in longitudinal changes for test scores and models that included mean dose, there was a correlation between mean infratentorial dose and intelligence quotient (IQ; −0.190 patients/Gy/year; P=.001), math (−0.164 patients/Gy/year; P=.010), reading (−0.137 patients/Gy/year; P=.011), and spelling scores (−0.147 patients/Gy/year; P=.012), where Gy was measured as the difference between the mean dose received by an individual patient and the mean dose received by the patient group. There was a correlation between mean anterior cerebellum dose and IQ scores (−0.116 patients/Gy/year; P=.042) and mean posterior cerebellum dose and IQ (−0.150 patients/Gy/year; P=.002), math (−0.120 patients/Gy/year; P=.023), reading (−0.111 patients/Gy/year; P=.012), and spelling (−0.117 patients/Gy/year; P=.015) scores. Conclusions: Sparing portions of the cerebellum should be considered in RT planning for children with infratentorial ependymoma because of the potential impact of radiation dose on cognitive function.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Simple and Efficient Methodology To Improve Geometric Accuracy in Gamma Knife Radiation Surgery: Implementation in Multiple Brain Metastases

Purpose: To propose, verify, and implement a simple and efficient methodology for the improvement of total geometric accuracy in multiple brain metastases gamma knife (GK) radiation surgery. Methods and Materials: The proposed methodology exploits the directional dependence of magnetic resonance imaging (MRI)-related spatial distortions stemming from background field inhomogeneities, also known as sequence-dependent distortions, with respect to the read-gradient polarity during MRI acquisition. First, an extra MRI pulse sequence is acquired with the same imaging parameters as those used for routine patient imaging, aside from a reversal in the read-gradient polarity. Then, “average” image data are compounded from data acquired from the 2 MRI sequences and are used for treatment planning purposes. The method was applied and verified in a polymer gel phantom irradiated with multiple shots in an extended region of the GK stereotactic space. Its clinical impact in dose delivery accuracy was assessed in 15 patients with a total of 96 relatively small (<2 cm) metastases treated with GK radiation surgery. Results: Phantom study results showed that use of average MR images eliminates the effect of sequence-dependent distortions, leading to a total spatial uncertainty of less than 0.3 mm, attributed mainly to gradient nonlinearities. In brain metastases patients, non-eliminated sequence-dependent distortions lead to target localization uncertainties of up to 1.3 mm (mean: 0.51 ± 0.37 mm) with respect to the corresponding target locations in the “average” MRI series. Due to these uncertainties, a considerable underdosage (5%-32% of the prescription dose) was found in 33% of the studied targets. Conclusions: The proposed methodology is simple and straightforward in its implementation. Regarding multiple brain metastases applications, the suggested approach may substantially improve total GK dose delivery accuracy in smaller, outlying targets.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comparative Studies of Optoelectrical Properties of Prominent PV Materials: Halide Perovskite, CdTe, and GaAs

We compare three representative high performance PV materials: halide perovskite MAPbI3, CdTe, and GaAs, in terms of photoluminescence (PL) efficiency, PL lineshape, carrier diffusion, and surface recombination and passivation, over multiple orders of photo-excitation density or carrier density appropriate for different applications. An analytic model is used to describe the excitation density dependence of PL intensity and extract the internal PL efficiency and multiple pertinent recombination parameters. A PL imaging technique is used to obtain carrier diffusion length without using a PL quencher, thus, free of unintended influence beyond pure diffusion. Our results show that perovskite samples tend to exhibit lower Shockley-Read-Hall (SRH) recombination rate in both bulk and surface, thus higher PL efficiency than the inorganic counterparts, particularly under low excitation density, even with no or preliminary surface passivation. PL lineshape and diffusion analysis indicate that there is considerable structural disordering in the perovskite materials, and thus photo-generated carriers are not in global thermal equilibrium, which in turn suppresses the nonradiative recombination. This study suggests that relatively low point-defect density, less detrimental surface recombination, and moderate structural disordering contribute to the high PV efficiency in the perovskite. This comparative photovoltaics study provides more insights into the fundamental material science and the search for optimal device designs by learning from different technologies.

14 SOLAR ENERGY↗

Helical tomotherapy quality assurance with ArcCHECK

To design a quality assurance (QA) procedure for helical tomotherapy that measures multiple beam parameters with 1 delivery and uses a rotating gantry to simulate treatment conditions. The customized QA procedure was preprogrammed on the tomotherapy operator station. The dosimetry measurements were performed using an ArcCHECK diode array and an A1SL ion chamber inserted in the central holder. The ArcCHECK was positioned 10 cm above the isocenter so that the 21-cm diameter detector array could measure the 40-cm wide tomotherapy beam. During the implementation of the new QA procedure, separate comparative measurements were made using ion chambers in both liquid and solid water, the tomotherapy onboard detector array, and a MapCHECK diode array for a period of 10 weeks. There was good agreement (within 1.3%) for the beam output and cone ratio obtained with the new procedure and the routine QA measurements. The measured beam energy was comparable (0.3%) to solid water measurement during the 10-week evaluation period, excluding 2 of the 10 measurements with unusually high background. The symmetry reading was similarly compromised for those 2 weeks, and on the other weeks, it deviated from the solid water reading by ∼2.5%. The ArcCHECK phantom presents a suitable alternative for performing helical tomotherapy QA, provided the background is collected properly. The proposed weekly procedure using ArcCHECK and water phantom makes the QA process more efficient.

61 RADIATION PROTECTION AND DOSIMETRY↗