Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Radiation Sources”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 793 records · Page 44

The Clinical Trials Program at the ESRF Biomedical Beamline ID17: Status and Remaining Steps

For several years the ID17 Biomedical beamline at the ESRF has developed synchrotron radiation therapy preclinical programmes to treat aggressive brain tumours. Two techniques have been developed at the ESRF:a) The Microbeam Radiation Therapy (MRT) using spatially fractionated 'white beam' (energies 50-300 keV) irradiation (beam widths 25-100 {mu}m, spacing between beams 200-400 {mu}m ) with extremely high dose rates (up to about 20 kGy/s) and depositing very high doses (300-1000 Gy) in the targeted tissue.b) The Stereotactic Synchrotron Radiation Therapy (SSRT) using spatially homogeneous monochromatic beam with the energy closely above that of the K-edge of a contrast- or chemotherapeutical agent (iodine, gadolinium, platinum) loaded into the tumour volume for obtaining a dose-enhancement. In 2005 an International review panel of oncology experts has recommended to move to clinical trials on humans in SSRT and on large animals in MRT. The works required for this program were launched in autumn 2007 with constructing a new, dedicated experimental hutch for MRT and a major upgrade of the existing sample-positioning station to a patient-positioning station for SSRT. In parallel, safety systems are developed and progressively implemented and a patient treatment-planning system developed.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Optimizing the XMaS Beamline for Low energy Operations to Maximize Benefits from the ESRF Upgrade Program

The XMaS beamline at the ESRF has been in regular user operation since April 1998 and operates over an energy range of 2.4-15 keV. It has developed a wide range of unique instrumentation, primarily dedicated to high resolution magnetic and single crystal diffraction. With the upcoming ESRF upgrade program a number of instrumental developments are planned for the beamline to maximize the benefits of the increased photon flux at low energies. Firstly we report on the optimisation of the beamline and its core components. A novel attenuator system which is actuated by fast acting solenoids thereby avoiding problems of gas bursts into the beamline vacuum seen on some commercially available instruments is introduced. Secondly we discuss developments to the low temperature sample environments that have been integrated into the beamline vacuum system, minimizing both air and beryllium absorption. Finally we demonstrate the current capabilities of the beamline by describing preliminary reflectivity measurements that have been made on an [Fe(2ML)Pd(15ML)]x20 multilayer recorded around the Pd L{sub 3} edge using circular polarised light produced from a thin diamond phase plate.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Extremely High Resolution Single Crystal Diffractometory for Orbital Resolution using High Energy Synchrotron Radiation at SPring-8

The investigation of accurate structure at charge density level will not only understand the function mechanism of physical property but also lead to design new functional materials. We have successfully installed large cylindrical camera at the BL02B1/SPring-8. In conceptual design, the image plate (IP) was selected as the detector, because such IP will not only detect wide range in one shot but also yield reliable data. In commissioning, the performance of this camera demonstrated to be suitable for the direct observation of d-electron system.

43 PARTICLE ACCELERATORS↗

New micro-beam beamline at SPring-8, targeting at protein micro-crystallography

A new protein micro-crystallography beamline BL32XU at SPring-8 is under construction and scheduled to start operation in 2010. The beamline is designed to provide the stabilized and brilliant micro-beam to collect high-quality data from micro-crystals. The beamline consists of a hybrid in-vacuum undulator, a liquid-nitrogen cooled double crystal monochromator, and K-B focusing mirrors with large magnification factor. Development of data acquisition system and end station consists of high-precision diffractometer, high-efficiency area detector, sample auto-changer etc. are also in progress.

43 PARTICLE ACCELERATORS↗

Thermal Expansion of NANOPERM-type Alloys from In-situ X-ray Diffraction

NANOPERM-type alloys with nominal compositions of (Fe{sub 1-x}Co{sub x}){sub 76}Mo{sub 8}Cu{sub 1}B{sub 15}(x = 0 and 0.5) were prepared by a single-roller melt-spinning technique. Temperature evolution of the as-quenched ribbons during constant-rate heating (10 degree sign C/min) was continuously followed using a high-energy (88 keV) X-ray diffraction (XRD), performed on the ID11 undulator beamline at the ESRF (Grenoble, France). Moessbauer spectroscopy and XRD confirm an amorphous nature of the melt-spun ribbons. Furthermore, Moessbauer spectroscopy reveals a significant change of magnetic state of the as-quenched precursors when substituting Fe by Co (x 0.5). Analyzing a series of XRD patterns in a reciprocal space yields a thermal expansion of the amorphous alloys providing an insight about the thermally activated effects such as relaxation and crystallization.

36 MATERIALS SCIENCE↗

Dosimetry And Its Enhancement Using Gold Nanoparticles In Synchrotron Based Microbeam And Stereotactic Radiosurgery

Research into the areas of synchrotron generated microbeam radiotherapy (MRT) and stereotactic radiosurgery is increasing. Such MRT techniques are showing potential of tackling some of the more difficult radiotherapy cases such as certain type of brain tumours. Two challenging aspects of these techniques are addressed in this investigation; the difficulty of dose determination and the delivery of the treatments at lower dose levels. In this research polymer gels were used as phantoms and dosimeters and cells were used to confirm outcomes. Normoxic polyacrylamide gels (nPAG) were tested as potential dosimeters for microbeam dosimetry. Following irradiation using microbeam and minibeam radiation from the BL28BU beam-line at Spring-8, Japan, the nPAG were scanned using a Raman spectroscopy technique. Dose enhancement caused by the inclusion of the gold nanoparticles (AuNPs) in the target was investigated using both cells and polymer gels. The use of AuNP could potentially reduce the dose required for the delivery of MRT. In this study it was shown that using endothelial cells with AuNPs, the minimal dose for clear cell killing along the beam line was reduced to 10 Gy. Both studies cell and gel studies indicates significant dose enhancement caused by the gold atoms in the target.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

MCNP Models for Tokamak Cooling Water System Equipment Evaluations

Heat generated in the ITER fusion reactor is deposited in the tokamak vacuum vessel, in-vessel components, and in the components of the neutral beam injector during plasma operations and during subsequent decay of activation products. This heat is managed by the tokamak cooling water system (TCWS). The stainless steel material in the integrated loop of blanket edge-localized mode vertical stabilization coils and divertor (IBED) components (e.g., piping, heat exchangers (HXs), and pumps) contains activation sources because of its exposure primarily to neutron radiation from the decay of 17 N, which is a short-lived radionuclide produced by neutron capture reactions with oxygen nuclei in the IBED primary heat transfer system (PHTS) cooling water during plasma operations. A detailed geometry model of the IBED stainless steel components and neutron radiation sources is required for an accurate assessment of the gamma activation sources on level 3 of the tokamak building. In the baseline design, each of the eight IBED PHTS cooling trains has two shell-and-tube heat exchangers (HXs) connected in series. Because these HXs are very large and contain a large amount of radioactive water, the possibility of using compact HXs of the welded shell-and-plate type is under investigation. This paper presents two Monte Carlo N-Particle (MCNP) TCWS geometry models, one model for each HX type, along with the associated piping. These models were obtained by automatic geometry conversion from TCWS computer-aided design models. In conclusion, the TCWS geometry models and neutron source definitions were incorporated into a baseline MCNP model of the Tokamak Complex.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Measurement of spin-density matrix elements for phi-meson photoproduction from protons and deuterons near threshold

The LEPS/SPring-8 experiment made a comprehensive measurement of the spin-density matrix elements for gammap->phip, gammad->phipn, and gammad->phid at forward production angles. A linearly polarized photon beam at E{sub g}amma=1.6-2.4 GeV was used for the production of phi mesons. The natural-parity Pomeron exchange processes remain dominant near threshold. The unnatural-parity processes of pseudoscalar exchange is visible in the production from the nucleons but is greatly reduced in the coherent production from deuterons. There is no strong E{sub g}amma dependence, but there is some dependence on momentum transfer. A small but finite value of the spin-density matrix elements reflecting helicity-nonconserving amplitudes in the t-channel is observed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Total cross sections for photoabsorption on light nuclei in the energy range 600-1500 MeV

Experimental data of the GRAAL Collaboration on the total cross sections for photoabsorption on deuterium and carbon targets at gamma-ray energies in the range between 600 and 1500 MeV are presented. The experiment was performed in a beam of photons obtained by the method of the Compton backscattering of laser photons at the electron storage ring of the European Synchrotron Radiation Facility (ESRF, Grenoble, France) by using a wide-aperture detector covering a solid angle close to 4{pi}. The total photoabsorption cross sections were determined by two independent methods: by subtracting the emptytarget background and by summing partial cross sections for meson photoproduction. The total cross sections for photoabsorption on quasifree protons and neutrons are shown to agree both in magnitude and in shape within a 5% precision of the measurements. In contrast to data previously available in the literature, both cross sections show distinctly the F{sub 15}(1680) resonance at a photon energy of about 1 GeV. Data obtained in the present experiment for the cross sections for photoabsorption on a free and a bound nucleon are compared. This comparison reveals a substantial role of two-nucleon correlations in estimating the nuclear-medium effect on meson photoproduction.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Performance evaluation of the USGS velocity model for the San Francisco Bay Area

In this study, we evaluated the performance of the United States Geological Survey velocity model developed for the San Francisco Bay Area (SFBA), version 21.1. The evaluation was performed through high-resolution three-dimensional physics-based ground motion simulations of seven small-magnitude earthquakes (ranging from magnitude 3.8 to 4.4) that occurred on the eastern side of the San Francisco Bay. The simulations were performed in the frequency range from 0 to 5 Hz with a minimum shear-wave velocity of 250 m/s, which allowed the capture of wave propagation effects of the near-surface soft materials that characterize local basins. Based on the direct comparison of Fourier amplitude spectra between recorded and simulated ground motions for more than 250 stations, we found that the velocity model generally performs well in the frequency range of 0.2–5 Hz. The median value of the Fourier amplitude residuals was found to be near zero for all seven earthquakes. The slight over-prediction of 0.2 log-natural units at frequencies above 3 Hz in our simulations was attributed to the potentially inaccurate representation of the source radiation pattern by a double-couple point source model, and simple representation of shallow small-scale underground structural complexity in the velocity model. Maps of spectral amplitude differences between the simulated and recorded data were used to identify areas responsible for systematic ground motion over-predictions or under-predictions. For example, while some sub-domains over soft sediments show over-prediction patterns, the block east of the Hayward fault is prone to exhibit patterns of under-prediction. These maps can be used to guide future refinements of the SFBA velocity model. Since our simulation methodology allows for the decoupling of the source and wave propagation effects, the ground motion data generated by our simulations can also be used to quantify the epistemic uncertainty due to the velocity model, in empirically based ground motion estimates for the SFBA.

58 GEOSCIENCES↗

FY2008 Report on GADRAS Radiation Transport Methods

The primary function of the Gamma Detector Response and Analysis Software (GADRAS) is the solution of inverse radiation transport problems, by which the configuration of an unknown radiation source is inferred from one or more measured radiation signatures. GADRAS was originally developed for the analysis of gamma spectrometry measurements. During fiscal years 2007 and 2008, GADRAS was augmented to implement the simultaneous analysis of neutron multiplicity measurements. This report describes the radiation transport methods developed to implement this new capability. This work was performed at the direction of the National Nuclear Security Administration's Office of Nonproliferation Research and Development. It was executed as an element of the Proliferation Detection Program's Simulation, Algorithm, and Modeling element.

Mattingly, John↗

A radionuclide counting technique for measuring wind velocity

A technique for measuring wind velocities of meteorological interest is described. It is based on inverse-square-law variation of the counting rates as the radioactive source-to-counter distance is changed by wind drag on the source ball. Results of a feasibility study using a weak bismuth 207 radiation source and three Geiger-Muller radiation counters are reported. The use of the technique is not restricted to Martian or Mars-like environments. A description of the apparatus, typical results, and frequency response characteristics are included. A discussion of a double-pendulum arrangement is presented. Measurements reported herein indicate that the proposed technique may be suitable for measuring wind speeds up to 100 m/sec, which are either steady or whose rates of fluctuation are less than 1 kHz.

Singh, J. J.↗

Recent Improvements to the LAURA and HARA Codes

This paper describes recent improvements to the LAURA and HARA codes. LAURA is a CFD code for aerothermodynamics, and HARA evaluates the shock-layer radiation that provides the radiative source term for the flowfield energy equations and radiative heating to a surface. The next release of LAURA and HARA includes a variety of new capabilities. These new capabilities include an automated uncertainty quantification workflow for radiative heat transfer, options for specifying surface roughness and turbulent transition location in the algebraic turbulence models, and improved grid and solution interpolation techniques. Additionally, the computational efficiency of both LAURA and HARA have been improved. Optimization of the MPI communication routines in LAURA are shown to improve the parallel efficiency of the primary flow when running with multiple processes per block, and recent optimization of HARA leverage graphics processing unit (GPU) acceleration in the radiation calculations. Using GPU acceleration of HARA is shown to decrease the cost of the radiation line-of-sight calculation by approximately one order of magnitude for a 10.5 km/s Earth entry simulation.

LAURA HARA CFD 5.6↗

Sound radiation from a vibrating cylinder in flow

An alternative approach to the conventional manner of calculating net power output of a source by integrating the energy flux over a distant control surface is presented. The method gives a means of calculating source radiation by an integral only over the source region and eliminates the need for a possibly difficult flux integration. The radiator chosen here is a finite, open ended, cylindrical shell of negligible thickness in the presence of uniform axial flow. A homogeneous medium without external boundaries is assumed. An integral representation and, in the long wave length approximation, an analytical expression for the power radiated by the vibrating cylinder are obtained. The results show power radiation may be increased or decreased by the presence of flow, depending on the relationship between the wave number of the vibration and the size of the radiator. The result is compared with results for simpler geometries.

Smith, M.↗

Rapid, autonomous analysis of HPGe gamma-ray spectra III: Plutonium identification and characterization

RadID is a gamma-ray spectrum analysis program originally written to assist in the detection of the illicit movement of nuclear material. It is specific to the rapid analysis of HPGe gamma-ray data to reveal the radionuclide signatures of interest that may be present in the spectra. It is an autonomous, rule-based heuristic system that can identify well over 200 radioactive sources in about one second. RadID does not require knowledge of the detector efficiency, the source-todetector distance, or the geometry of the inspected radiation source—including any shielding. In this third of a three-document series we discuss how RadID detects the presence of plutonium isotopes and determines a number of its characteristics, most notably: the spectral characteristics of weapons-grade plutonium, reactor-grade plutonium, and heat-source plutonium used in radioisotope thermoelectric generators.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Watts Bar I ex-core analyses using VERA - 25430

The integration and direct coupling of the Oak Ridge National Laboratory (ORNL) Shift Monte Carlo code within the Consortium for Advanced Simulation of Light Water Reactors (CASL) Virtual Environment for Reactor Applications (VERA) offers unique capabilities that combine high-fidelity in-core and ex-core radiation transport. In this recent development activity, the deterministic neutronics code MPACT performs the in-core radiation transport with temperature feedback using COBRA-TF (CTF), and provides the fission source to Shift for a follow-on fixed source radiation transport calculation to determine ex-core quantities of interest. The coupling of MPACT to Shift allows the neutron source for the ex-core transport to be calculated from the time-dependent, fully coupled MPACT solution. This paper presents the first use of VERA to perform coupon irradiation for code-to-code comparison of its ex-core capabilities. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

A theoretical study on phase-contrast mammography with Thomson-scattering x-ray sources

Purpose: The x-ray transmitted beam from any material/tissue depends on the complex refractive index (n=1-{delta}+i{beta}), where {delta} is responsible for the phase shift and {beta} is for the beam attenuation. Although for human tissues, the {delta} cross section is about 1000 times greater than the {beta} ones in the x-ray energy range from 10 to 150 keV, the gain in breast tumor visualization of phase-contrast mammography (PCM) with respect to absorption contact imaging (AI) is limited by the maximum dose that can be delivered to the patient. Moreover, in-line PC imaging (PCI) is the simplest experimental mode among all available x-ray PCI techniques since no optics are needed. The latter is a fundamental requirement in order to transfer the results of laboratory research into hospitals. Alternative to synchrotron radiation sources, the implementation of relativistic Thomson-scattering (TS) x-ray sources is particularly suitable for hospital use because of their high peak brightness within a relatively compact and affordable system. In this work, the possibility to realize PCM using a TS source in a hospital environment is studied, accounting for the effect of a finite deliverable dose on the PC visibility enhancement with respect to AI. Methods: The contrast-to-noise ratio of tumor-tissue lesions in PCM has been studied on the bases of a recent theoretical model, describing image contrast formation by means of both wave-optical theory and the mutual coherence formalism. The latter is used to describe the evolution, during wave propagation, of the coherence of the wave field emitted by a TS source. The contrast-to-noise ratio for both PCI and AI has been analyzed in terms of tumor size, beam energy, detector, and source distances, studying optimal conditions for performing PCM. Regarding other relevant factors which could influence ''tumor'' visibility, the authors have assumed simplified conditions such as a spherical shape description of the tumor inclusion, a constant surrounding background, ideal conditions for the calculus of the contrast-to-noise ratio. Results: The results show the possibility to enhance with PCI the signal-to-noise ratio for features in the submillimeter scale. This finding could give PCM a great advantage with respect to AI, opening the possibility to decrease the number of wrong diagnoses before histological exams. The results agree with experimental evidences obtained by Dreossi et al.[D. Dreossi et al., ''The mammography project at the SYRMEP beamline,'' Eur. J. Radiol. 68, S58-S62 (2008)] with real PCM using synchrotron radiation. Conclusions: The challenging characteristics of TS sources, suitable for PCM, should be fluxes of at least 10{sup 11} photons/s emitted by very small sources of about 10 {mu}m, together with moderate energy spreads (less than 10%) in order to realize both sufficient spatial coherence and enough fluence on the patient, collecting images in reasonable exposure times. These fluxes will be achieved by next generation TS sources which are already under development.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A hybrid continuous-wave terahertz imaging system

A hybrid (active-passive mode) terahertz (THz) imaging system and an algorithm for imaging synthesis are proposed to enhance the THz image quality. The concept of image contrast is used to compare active and passive THz imaging. Combining the measurement of the self-emitted radiation of the object with the back-scattered source radiation measurement, it becomes possible to use the THz image to retrieve maximum information about the object. The experimental results confirm the advantages of hybrid THz imaging systems, which can be generalized for a wide range of applications in the material sciences, chemical physics, bio-systems, etc.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗