Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Radiation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 793 records · Page 44

Effect of Spectrally Varying Albedo of Vegetation Surfaces on Shortwave Radiation Fluxes and Aerosol Direct Radiative Forcing

This study develops an algorithm for representing detailed spectral features of vegetation albedo based on Moderate Resolution Imaging Spectrometer (MODIS) observations at 7 discrete channels, referred to as the MODIS Enhanced Vegetation Albedo (MEVA) algorithm. The MEVA algorithm empirically fills spectral gaps around the vegetation red edge near 0.7 micrometers and vegetation water absorption features at 1.48 and 1.92 micrometers which cannot be adequately captured by the MODIS 7 channels. We then assess the effects of applying MEVA in comparison to four other traditional approaches to calculate solar fluxes and aerosol direct radiative forcing (DRF) at the top of atmosphere (TOA) based on the MODIS discrete reflectance bands. By comparing the DRF results obtained through the MEVA method with the results obtained through the other four traditional approaches, we show that filling the spectral gap of the MODIS measurements around 0.7 micrometers based on the general spectral behavior of healthy green vegetation leads to significant improvement in the instantaneous aerosol DRF at TOA (up to 3.02Wm(exp -2) difference or 48% fraction of the aerosol DRF, .6.28Wm(exp -2), calculated for high spectral resolution surface reflectance from 0.3 to 2.5 micrometers for deciduous vegetation surface). The corrections of the spectral gaps in the vegetation spectrum in the near infrared, again missed by the MODIS reflectances, also contributes to improving TOA DRF calculations but to a much lower extent (less than 0.27Wm(exp -2), or about 4% of the instantaneous DRF). Compared to traditional approaches, MEVA also improves the accuracy of the outgoing solar flux between 0.3 to 2.5 micrometers at TOA by over 60Wm(exp -2) (for aspen 3 surface) and aerosol DRF by over 10Wm(exp -2) (for dry grass). Specifically, for Amazon vegetation types, MEVA can improve the accuracy of daily averaged aerosol radiative forcing in the spectral range of 0.3 to 2.5 micrometers at equator at the equinox by 3.7Wm(exp -2). These improvements indicate that MEVA can contribute to regional climate studies over vegetated areas and can help to improve remote sensing-based studies of climate processes and climate change.

Zhu, L.↗

Single Board Computer Radiation Test Results and Radiation Test Software

Single Board Computers (SBCs) are quickly evolving and gaining capability as their cost comes down. As their footprints, cost, and power requirements decrease, their processing power increases. This makes them very attractive for use on space missions and an enabling technology as spacecraft size decreases and computational demand increases. One of the major challenges electronics face in the space environment is radiation. In 2019, the NASA Johnson Space Center (JSC) tested a selection of SBCs to low Earth orbit (LEO) radiation levels and evaluated their susceptibility and survivability. For this test campaign, JSC developed a Python software suite to better characterize the SBCs performance and intends to share the software.

Pedrotty, Samuel M.↗

Radiation-Resistant Ti/BN Coatings: Insights From 171 Days Exposure to Space Radiation and Atomic Oxygen in Low Orbit

Atmospheric Plasma Spray (APS) and Vacuum Plasma Spray (VPS) techniques were used to develop Ti/2 vol.% hBN coatings, for extreme space environments and tested aboard the International Space Station as part of the MISSE-17 (Materials International Space Station Experiments) program. The coatings were exposed to atomic oxygen, space radiation, and low-orbit thermal cycling. VPS coatings showed a 56% increase in microhardness, a 26% rise in elastic modulus, minimal porosity and crack density changes compared to APS coatings. The change in mechanical properties is attributed to the formation of TiO, TiO₂ and TiN from nitrogen retention, alongside radiation-induced dislocations, which enhanced surface hardening. The oxidation of titanium led to the formation of TiO and TiO₂, while boron nitride was retained and underwent transmutation in VPS coatings. XPS and EDS analyses confirmed the enhanced space-environment resistance of VPS coatings, making them ideal for long-term spacecraft protection in lunar and Martian conditions.

Abhijith Kunneparambil Sukumaran↗

Partnership for Radiation Studies (PaRS): A Consortium for Advancing Radiation Science among Underrepresented STEM Students

The Partnership for Radiation Studies (PaRS) consortium was recently awarded by U.S. Department of Energy’s National Nuclear Security Administration (NNSA). The five-year grant aims to increase the number of underrepresented students in STEM disciplines, with simultaneous advancement of nuclear radiation science. The goal is to hire more underrepresented minorities at national laboratories. The consortium’s progress will be tracked/reported annually. This paper and subsequent presentation cover details of the consortium, highlighting the key activities of participating national laboratories in assisting the minority-serving institutions.

Minority Serving Institutions Partnership Program,↗

Radiation Effects on the Microstructure of a 9Cr-ODS Alloy

Oxide dispersion strengthened (ODS) steels are a prime candidate for high temperature, high dose cladding in advanced nuclear reactors. A 9Cr-ODS alloy was irradiated with 5 MeV Ni ions at temperatures of 500, 600 and 700ºC to doses up to 150 dpa. There was no significant change in the dislocation arrangement. For oxide particles, there is a small shrinkage in size and increase in density with increasing irradiation dose. The atom probe analysis on the unirradiated and the Ni ion irradiated 9Cr-ODS at 700ºC to 150 dpa shows similar spatial configuration of oxide particles. Radiation-induced void swelling was not identified following Ni ion irradiation. Irradiation with 1.0 MeV Kr ions at temperatures of 500, 600, 700 and 800ºC to doses of 30-50 dpa reveals the presence of voids in all the irradiation conditions and it is believed to be due to Kr ions trapped in the materials. This work confirms that oxide particles and the microstructure of the 9Cr- ODS show minimal and acceptable changes under irradiation at temperature up to 700ºC and doses up to 150 dpa.

36 MATERIALS SCIENCE↗

Long-Term Results of a Randomized Trial Comparing Iridium Implant Plus External Beam Radiation Therapy With External Beam Radiation Therapy Alone in Node-Negative Locally Advanced Cancer of the Prostate

Purpose: To determine the impact on long-term survival from the addition of brachytherapy to external beam radiation therapy (EBRT) in patients with prostate cancer. Methods and Materials: Between 1992 and 1997, 104 men with cT2-3, surgically staged node-negative prostate cancer were randomized to receive either EBRT (40 Gy/20 fractions) with iridium implant (35 Gy/48 hours) or EBRT alone (66 Gy/33 fractions) to the prostate. According to T stage, Gleason score, and prostate-specific antigen level, 60% of patients had high-risk disease. Substantial improvements in biochemical control at 8 years have previously been reported. Additional follow-up was collected on deaths and metastases. Results: Median follow-up was 14 years. Five patients were lost to follow-up. All other patients have been followed a minimum of 13 years. There have been 75 deaths, including 21 from prostate cancer and 25 from second cancers. No patients developing a second cancer have died from prostate cancer. There was no difference in overall survival between the 2 treatment groups: 34 deaths (67%) in the implant arm and 41 (77%) in the EBRT arm (hazard ratio [HR] 1.00, 95% confidence interval [CI] 0.63-1.59). Similarly, there was no difference in prostate cancer–specific deaths: 9 (18%) patients in the implant arm compared with 12 (23%) in the EBRT arm (HR 0.79, 95% CI 0.34-1.87). There was no statistically significant difference in the number of patients developing metastatic disease: 10 (20%) in the implant arm and 15 (28%) in the EBRT arm (HR 0.70, 95% CI 0.32-1.57). Improvements in biochemical control were maintained (HR 0.53, 95% CI 0.31-0.88). Conclusions: Despite a dramatic reduction of biochemical recurrence rates, the addition of iridium implant to EBRT did not translate into improved overall survival or prostate cancer–specific survival.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Implicit filtered P{sub N} for high-energy density thermal radiation transport using discontinuous Galerkin finite elements

In this work, we provide a fully-implicit implementation of the time-dependent, filtered spherical harmonics (FP{sub N}) equations for non-linear, thermal radiative transfer. We investigate local filtering strategies and analyze the effect of the filter on the conditioning of the system, showing in particular that the filter improves the convergence properties of the iterative solver. We also investigate numerically the rigorous error estimates derived in the linear setting, to determine whether they hold also for the non-linear case. Finally, we simulate a standard test problem on an unstructured mesh and make comparisons with implicit Monte Carlo (IMC) calculations.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Radiation flux and spectral analysis of the multi-temperature Z dynamic hohlraum

Experiments performed at the Sandia National Laboratories (SNL) Z-machine, located in Albuquerque, New Mexico produce hot ({approx}220 eV) plasmas. X-ray emission from the plasma is used to drive radiation flow experiments. Our standard plasma diagnostic suite consists of x-ray diodes (XRDs), silicon photodiodes, and nickel thin film bolometers. Small diagnostic holes allow us to view the hot plasma from the side, top axial anode side, and bottom axial cathode side. Computer software has been written to process the raw data to calculate data quality, fold in detector spectral response and experiment geometry for emitted flux, calculate a multidetector spectral unfold, and yield an equivalent time-dependent Planckian temperature profile. Spectral unfolds of our XRD data generally yield a Planckian-like spectrum. In our presentation we will compare our diagnostic techniques, analysis, and results to more accurately characterize spectral unfolds in order to establish better drive conditions for our experiments.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The interaction of 193 nm excimer laser radiation with single-crystal zinc oxide: Generation of long lived highly excited particles with evidence of Zn Rydberg formation

In past studies, we have observed copious emissions of ionic and atomic Zn from single-crystal ZnO accompanying irradiation of single-crystal ZnO with 193-nm excimer laser irradiation at fluences below the onset of optical breakdown. The Zn{sup +} and ground state Zn° are studied using time-of-flight techniques and are mass selected using a quadrupole mass spectrometer. Simultaneously, we have observed emitted particles that are detectable with a Channeltron electron multiplier but cannot be mass selected. It is a reasonable hypothesis that these particles correspond to a neutral atom or molecule in highly excited long lived states. We provide strong evidence that they correspond to high lying Rydberg states of atomic Zn. We propose a production mechanism involving laser excitation via a two photon resonance excitation of Zn°.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Laser absorption, power transfer, and radiation symmetry during the first shock of inertial confinement fusion gas-filled hohlraum experiments

Temporally resolved measurements of the hohlraum radiation flux asymmetry incident onto a bismuth coated surrogate capsule have been made over the first two nanoseconds of ignition relevant laser pulses. Specifically, we study the P2 asymmetry of the incoming flux as a function of cone fraction, defined as the inner-to-total laser beam power ratio, for a variety of hohlraums with different scales and gas fills. This work was performed to understand the relevance of recent experiments, conducted in new reduced-scale neopentane gas filled hohlraums, to full scale helium filled ignition targets. Experimental measurements, matched by 3D view factor calculations, are used to infer differences in symmetry, relative beam absorption, and cross beam energy transfer (CBET), employing an analytic model. Despite differences in hohlraum dimensions and gas fill, as well as in laser beam pointing and power, we find that laser absorption, CBET, and the cone fraction, at which a symmetric flux is achieved, are similar to within 25% between experiments conducted in the reduced and full scale hohlraums. This work demonstrates a close surrogacy in the dynamics during the first shock between reduced-scale and full scale implosion experiments and is an important step in enabling the increased rate of study for physics associated with inertial confinement fusion.

2-2-DIMETHYLPROPANE↗

Simulation of the Post-Shot Radiation Environment in the National Ignition Facility

The National Ignition Facility at Lawrence Livermore National Laboratory is the world’s biggest and most energetic laser system for inertial confinement fusion. The NIF is designed to perform shots with varying fusion yield (up to 20 MJ or 7.1 × 10 18 neutrons per shot). A great number of diagnostic instruments are present inside the target chamber (TC) and target bay (TB) during shots. The gamma dose rates due to neutron activation are estimated at various decay times following the high-yield (20-MJ) shots. Several components, like the snout assemblies of the diagnostic instrument manipulators and target positioners are inserted inside the TC, close to the target during the shot. These components represent major sources of gamma decay after retraction outside the TC. Five days after a 20-MJ shot, dose rates near the highly activated (retracted) parts are on the order of 1 mSv/h and dose rates within the TB outside the TC but at distance from the retracted components drop to about 50 to 70 μSv/h. The dose is dominated by decay of 24 Na (T 1/2 = 14.95 h) and waiting for two additional days drops the dose rates significantly. Seven days following a 20-MJ shot, dose rates in the immediate vicinity of the retracted components drop to <0.2 mSv/h and the general ambient dose rates within the TB (away from retracted components) near the TC drop to <10 μSv/h. Dose rates at much larger distances from the TC (near TB wall) are an order of magnitude lower. Detailed radiation transport simulations are performed to create detailed dose rate maps for all floors inside the TB. The maps are used to measure worker stay-out times following shots before entry is permitted into the TB.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-E-T-338: Dosimetric Study of Volumetric Modulated Arc Therapy (VMAT) and Intensity Modulated Radiation Therapy (IMRT) for Stereotactic Body Radiation Therapy (SBRT) in Early Stage Lung Cancer

Purpose: This study evaluates the dosimetric differences using volumetric modulated arc therapy (VMAT) in patients previously treated with intensity modulated radiation therapy IMRT for stereotactic body radiotherapy (SBRT) in early stage lung cancer. Methods: We evaluated 9 consecutive medically inoperable lung cancer patients at the start of the SBRT program who were treated with IMRT from November 2010 to October 2011. These patients were treated using 6 MV energy. The 9 cases were then re-planned with VMAT performed with arc therapy using 6 MV flattening filter free (FFF) energy with the same organs at risk (OARS) constraints. Data collected for the treatment plans included target coverage, beam on time, dose to OARS and gamma pass rate. Results: Five patients were T1N0 and four patients were T2N0 with all tumors less than 5 cm. The average GTV was 13.02 cm3 (0.83–40.87) and average PTV was 44.65 cm3 (14.06–118.08). The IMRT plans had a mean of 7.2 angles (6–9) and 5.4 minutes (3.6–11.1) per plan. The VMAT plans had a mean of 2.8 arcs (2–3) and 4.0 minutes (2.2–6.0) per plan. VMAT had slightly more target coverage than IMRT with average increase in D95 of 2.68% (1.24–5.73) and D99 of 3.65% (0.88–8.77). VMAT produced lower doses to all OARs. The largest reductions were in maximum doses to the spinal cord with an average reduction of 24.1%, esophagus with an average reduction of 22.1%, and lung with an average reduction in the V20 of 16.3% The mean gamma pass rate was 99.8% (99.2–100) at 3 mm and 3% for VMAT with comparable values for IMRT. Conclusion: These findings suggest that using VMAT for SBRT in early stage lung cancer is superior to IMRT in terms of dose coverage, OAR dose and a lower treatment delivery time with a similar gamma pass rate.

60 APPLIED LIFE SCIENCES↗