DOE OSTI2017
The 200 West Pump and Treat (P and T), on the U.S. Department of Energy's Hanford Site and operated by CH2M HILL Plateau Remediation Company, has a 9,464 liters per minute capacity designed to capture and treat an 8 km{sup 2} contaminated groundwater plume and reduce the mass of contaminants of concern (COCs) by 95 percent in 25 years. The plume is a complex mix of contaminants including technetium-99 (Tc-99), uranium, carbon tetrachloride, chromium, hexavalent chromium, nitrate, and iodine-129 (I-129). Ion exchange (IX), a common treatment approach for Tc-99 used by many nuclear remediation sites, is used to remove uranium and Tc-99 at 200 West P and T. The IX vessels are arranged in a sequence of three to provide a lead, lag and polish vessel. Tc-99 concentrations are monitored monthly to assure good performance of the system. Performance tracking revealed surprising results. On October 14, 2015, the resin in the lead vessels released Tc-99 at concentrations greater than what was being fed. Although Tc-99 was captured by the downstream lag and polish vessels, the facility staff grabbled with the sudden release of Tc-99 entertaining a variety of scenarios that might result in sudden failure of the IX processes. Subsequent sampling indicated Tc-99 removal began a steady return to normal. The incident raised many questions, chief among them whether the same events could recur and undermine Tc-99 treatment. (authors)
12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗