Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “RESINS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 793 records · Page 44

Electronically and ionically conductive porous material and method for manufacture of resin wafers therefrom

An electrically and ionically conductive porous material including a thermoplastic binder and one or more of anion exchange moieties or cation exchange moieties or mixtures thereof and/or one or more of a protein capture resin and an electrically conductive material. The thermoplastic binder immobilizes the moieties with respect to each other but does not substantially coat the moieties and forms the electrically conductive porous material. A wafer of the material and a method of making the material and wafer are disclosed.

36 MATERIALS SCIENCE↗

Methane production using resin-wafer electrodeionization

The present invention provides an efficient method for creating natural gas including the anaerobic digestion of biomass to form biogas, and the electrodeionization of biogas to form natural gas and carbon dioxide using a resin-wafer deionization (RW-EDI) system. The method may be further modified to include a wastewater treatment system and can include a chemical conditioning/dewatering system after the anaerobic digestion system. The RW-EDI system, which includes a cathode and an anode, can either comprise at least one pair of wafers, each a basic and acidic wafer, or at least one wafer comprising of a basic portion and an acidic portion. A final embodiment of the RW-EDI system can include only one basic wafer for creating natural gas.

03 NATURAL GAS↗

Novel Alkyd-Type Coating Resins Produced Using Cationic Polymerization [PowerPoint]

Novel, partially bio-based poly(vinyl ether) copolymers derived from soybean oil and cyclohexyl vinyl ether (CHVE) were produced by cationic polymerization and investigated for application as alkyd-type surface coatings. Compared to conventional alkyd resins, which are produced by high temperature melt condensation polymerization, the poly(vinyl ether)s provide several advantages. These advantages include miler, more energy efficient polymer synthesis, elimination of issues associated with gelation during polymer synthesis, production of polymers with well-defined composition and relatively narrow molecular weight distribution, and elimination of film formation and physical property issues associated with entrained monomers, dimers, trimmers, etc. The results of the studied showed that the thermal, mechanical, and physical properties of the coatings produced from these novel polymers varied considerable as a function of polymer composition and cure temperature. Overall, the results suggest a good potential for these novel copolymers to be used for coatings cured by autoxidation.

99 GENERAL AND MISCELLANEOUS↗

Synthesis and Characterization of Polymeric Pore Former Microspheres using Modified Polymer Resin

Porosity in polymer parts is often desired to improve mechanical properties. Individual pores must be small enough that bulk mechanical properties are retained but significant enough to reduce the density of the material. Filler materials can be incorporated into polymer matrices and subsequently removed to create voids. The materials used to create the voids are known as pore-formers. The present research aims to create spherical pores in a silicone matrix by inserting and removing core materials or fillers post-cure. A method was developed to incorporate pore formers into an uncured polymer resin and remove the materials from the matrix. Polyethylene Glycol (PEG) and Polylactic Acid (PLA) microspheres are created and incorporated into silicone matrices as pore formers. Microspheres with controllable size distributions are formed via ultrasonic spray pyrolysis and emulsion formation. Microspheres are removed from the matrix by solvent extraction and calcination. PLA microspheres were modified by hydroxyl addition to the surface to study their solubility in water. PEG-PLA block copolymers are also synthesized and investigated, comparing their physical and chemical properties to the monomers to identify whether the block copolymer microspheres will be more easily removable than their monomeric microspheres. Moreover, other properties including thermal stability, rheology, and mechanical response are studied. The present dissertation provides a comprehensive understanding of the synthesis and characterization of PEG and PLA-based pore formers, toward the future development of feedstock for additive manufacturing porous structures.

Damptey, Ransford↗

Removal of Technetium-99 on Ion Exchange Resin - A Case Study at 200 West Pump and Treat - 17303

The 200 West Pump and Treat (P and T), on the U.S. Department of Energy's Hanford Site and operated by CH2M HILL Plateau Remediation Company, has a 9,464 liters per minute capacity designed to capture and treat an 8 km{sup 2} contaminated groundwater plume and reduce the mass of contaminants of concern (COCs) by 95 percent in 25 years. The plume is a complex mix of contaminants including technetium-99 (Tc-99), uranium, carbon tetrachloride, chromium, hexavalent chromium, nitrate, and iodine-129 (I-129). Ion exchange (IX), a common treatment approach for Tc-99 used by many nuclear remediation sites, is used to remove uranium and Tc-99 at 200 West P and T. The IX vessels are arranged in a sequence of three to provide a lead, lag and polish vessel. Tc-99 concentrations are monitored monthly to assure good performance of the system. Performance tracking revealed surprising results. On October 14, 2015, the resin in the lead vessels released Tc-99 at concentrations greater than what was being fed. Although Tc-99 was captured by the downstream lag and polish vessels, the facility staff grabbled with the sudden release of Tc-99 entertaining a variety of scenarios that might result in sudden failure of the IX processes. Subsequent sampling indicated Tc-99 removal began a steady return to normal. The incident raised many questions, chief among them whether the same events could recur and undermine Tc-99 treatment. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Refractive index matching base resin for extremely fine three-dimensional ceramic structures

An optically clear resin for additive manufacturing includes an optically clear ceramic precursor having a pre-defined refractive index. Each molecule of the ceramic precursor has at least two photopolymerizable functional groups, at least one of the photopolymerizable functional groups being functionalized with a refractive index-tuning group thereby causing the ceramic precursor to have the pre-defined refractive index.

Mettry, Magi↗

Microscale depletion of high abundance proteins in human biofluids using IgY14 immunoaffinity resin: Analysis of human plasma and cerebrospinal fluid

Removal of highly abundant proteins in plasma is often carried out using immunoaffinity depletion to extend the dynamic range of measurements to lower abundance species. While commercial depletion columns are available for this purpose, they generally are not applicable to limited sample quantities (<20 µL) due to low yields stemming from losses caused by nonspecific binding to the column matrix. Additionally, the cost of the depletion media can be prohibitive for larger scale studies. Modern LC-MS instrumentation provides the sensitivity necessary to scale-down depletion methods with minimal sacrifice to proteome coverage, which makes smaller volume depletion columns desirable for maximizing sample recovery when samples are limited, as well as for reducing the expense of large scale studies. We characterized the performance of a 346 µL column volume micro-scale depletion system, using four different flow rates to determine the most effective depletion conditions for ~6 μL injections of human plasma proteins and then evaluated depletion reproducibility at the optimum flow rate condition. Depletion of plasma using a commercial 10 mL depletion column served as the control. Results showed depletion efficiency of the micro-scale column increased as flow rate decreased, and that our micro-depletion was reproducible. We found, in an initial application, a 600 µL sample of human cerebral spinal fluid (CSF) pooled from multiple sclerosis patients was depleted and then analyzed using reversed phase liquid chromatography-mass spectrometry to demonstrate the utility of the system for this important biofluid where sample quantities are more commonly limited.

59 BASIC BIOLOGICAL SCIENCES↗

Radioembolization with {sup 90}Y Resin Microspheres of Neuroendocrine Liver Metastases: International Multicenter Study on Efficacy and Toxicity

Purpose: Radioembolization of liver metastases of neuroendocrine neoplasms (NEN) has shown promising results; however, the current literature is of limited quality. A large international, multicentre retrospective study was designed to address several shortcomings of the current literature. Materials: 244 NEN patients with different NEN grades were included. Methods: Primary outcome parameters were radiologic response 3 and 6 months after treatment according to RECIST 1.1 and mRECIST. Secondary outcome parameters included clinical response, clinical and biochemical toxicities. Results: Radioembolization resulted in CR in 2%, PR in 14%, SD in 75% and PD 9% according to RECIST 1.1 and in CR in 8%, PR in 35%, SD in 48% and PD in 9% according to mRECIST. Objective response rates improved over time in 20% and 26% according to RECIST 1.1. and mRECIST, respectively. Most common new grade 3–4 biochemical toxicity was lymphocytopenia (6.7%). No unexpected clinical toxicities occurred. Radioembolization-specific complications occurred in < 4%. In symptomatic patients, improvement and resolution of symptoms occurred in 44% and 34%, respectively. Median overall survival from first radioembolization was 3.7, 2.7 and 0.7 years for G1, G2 and G3, respectively. Objective response is independent of NEN grade or primary tumour origin. Significant prognostic factors for survival were NEN grade/Ki67 index, ≥ 75% intrahepatic tumour load, the presence of extrahepatic disease and disease control rate according to RECIST 1.1. Conclusion: Safety and efficacy of radioembolization in NEN patients was confirmed with a high disease control rate of 91% in progressive patients and alleviation of NEN-related symptoms in 79% of symptomatic patients. Level of evidence: 4.

62 RADIOLOGY AND NUCLEAR MEDICINE↗