Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “READOUT SYSTEMS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 793 records · Page 44

The Trigger System of ICARUS-T600 Detector at Fermilab

The ICARUS-T600 liquid argon (LAr) time projection chamber (TPC) detector is currently deployed as a far detector of the Short Baseline Neutrino (SBN) program at Fermilab (USA) to search for a possible LSND-like sterile neutrino signal at $\Deltam^2 \approx 1eV^2$ with the Booster (BNB) and Main Injector (NuMI) Neutrino Beams. A global physical event rate of $\approx 0.6$ Hz, including the genuine neutrino interactions in LAr, beam halos and cosmic interactions inside the proton pulse time windows, is expected, roughly corresponding to $\approx 4$ PB of data for the total 6.6 $10^{20}$ pot exposure if the full ICARUS-T600 detector is readout ($\approx 200$ MB event size). The designed trigger system described here will collect the genuine neutrino interactions with a $\approx 95$\% expected efficiency.

Copello, S. [INFN, Pavia]↗

Noise Erasure in Quantum-Limited Current Amplifiers

Superconducting quantum interference devices (SQUIDs) are extraordinarily sensitive to magnetic flux and thus make excellent current amplifiers for cryogenic applications. One such application of high interest to Sandia is the set-up and state read-out of quantum dot based qubits, where a qubit state is read out from a short current pulse (microseconds to milliseconds long) of approximately 100 pA, a signal that is easily corrupted by noise in the environment. A Parametric SQUID Amplifier can be high bandwidth (in the GHz range), low power dissipation (less than 1pW), and can be easily incorporated into multi-qubit systems. In this SAIL LDRD, we will characterize the noise performance of the parametric amplifier front end -- the SQUID -- in an architecture specific to current readout for spin qubits. Noise is a key metric in amplification, and identifying noise sources will allow us to optimize the system to reduce its effects, resulting in higher fidelity readout. This effort represents a critical step in creating the building blocks of a high speed, low power, parametric SQUID current amplifier that will be needed in the near term as quantum systems with many qubits begin to come on line in the next few years.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Observation of Synchronization between Two Quantum van der Pol Oscillators in Trapped Ions

Synchronization is a hallmark of collective behavior that emerges when nonlinear systems interact, spanning scales from mechanical oscillators to planetary orbits. As a universal phenomenon, it underpins the study of complex systems and has far-reaching technological implications. While classical synchronization has a long and rich history, it has not been observed experimentally between multiple quantum limit-cycle oscillators despite a decade of theoretical investigations. We realize synchronization between two quantum van der Pol oscillators by engineering dissipation in a mixed-isotope trapped-ion quantum simulator. The synchronized state is encoded in a fixed relative phase between the oscillators that is inaccessible to individual measurements and revealed only through joint readout of both oscillators, in stark contrast to the system in the (deterministic) classical limit where synchronization can be observed via individual phase measurements. We further show that the relative phase can be precisely controlled and that the chain of two oscillators can synchronize to an external field, suggesting applications in sensing. Our results provide a promising pathway for studying more complex synchronized quantum dynamics beyond two oscillators, where a theoretical treatment becomes increasingly challenging, and it remains to be understood whether genuinely quantum features persist in such cases.

Liu, Jiarui↗

Solar heating system at Quitman County Bank, Marks, Mississippi

Information on the Solar Energy Heating System installed in a single story wood frame, cedar exterior, sloped roof building is presented. The system has on-site temperature and power measurements readouts. The 468 square feet of Solaron air flat plate collectors provide for 2,000 square feet of space heating, an estimated 60 percent of the heating load. Solar heated air is distributed to the 235 cubic foot rock storage box or to the load (space heating) by a 960 cubic feet per minute air handler unit. A 7.5 ton Carrier air-to-air heat pump with 15 kilowatts of electric booster strips serve as a back-up (auxiliary) to the solar system. Motorized dampers control the direction of airflow and back draft dampers prevent thermal siphoning of conditioned air.

Source record↗

Upgrade of the Minos+ Experiment Data Acquisition for the High Energy NuMI Beam Run

The Minos+ experiment is an extension of the Minos experiment at a higher energy and more intense neutrino beam, with the data collection having begun in the fall of 2013. The neutrino beam is provided by the Neutrinos from the Main Injector (NuMI) beam-line at Fermi National Accelerator Laboratory (Fermilab). The detector apparatus consists of two main detectors, one underground at Fermilab and the other in Soudan, Minnesota with the purpose of studying neutrino oscillations at a base line of 735 km. The original data acquisition system has been running for several years collecting data from NuMI, but with the extended run from 2013, parts of the system needed to be replaced due to obsolescence, reliability problems, and data throughput limitations. Specifically, we have replaced the front-end readout controllers, event builder, and data acquisition computing and trigger processing farms with modern, modular and reliable devices with few single points of failure. The new system is based on gigabit Ethernet TCP/IP communication to implement the event building and concatenation of data from many front-end VME readout crates. The simplicity and partitionability of the new system greatly eases the debugging and diagnosing process. As a result, the new system improves throughput by about a factor of three compared to the old system, up to 800 megabits per second, and has proven robust and reliable in the current run.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Anomalous Loss Reduction Below Two‐Level System Saturation in Aluminum Superconducting Resonators

Superconducting resonators are widely used in many applications such as qubit readout for quantum computing, and kinetic inductance detectors. These resonators are susceptible to numerous loss and noise mechanisms, especially the dissipation due to two-level systems (TLS) which become the dominant source of loss in the few-photon and low temperature regime. In this study, capacitively-coupled aluminum half-wavelength coplanar waveguide resonators are investigated. Surprisingly, the loss of the resonators is observed to decrease with a lowering temperature at low excitation powers and temperatures below the TLS saturation. This behavior is attributed to the reduction of the TLS resonant response bandwidth with decreasing temperature and power to below the detuning between the TLS and the resonant photon frequency in a discrete ensemble of TLS. When response bandwidths of TLS are smaller than their detunings from the resonance, the resonant response and thus the loss is reduced. At higher excitation powers, the loss follows a logarithmic power dependence, consistent with predictions from the generalized tunneling model (GTM). A model combining the discrete TLS ensemble with the GTM is proposed and matches the temperature and power dependence of the measured internal loss of the resonator with reasonable parameters.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Transparent Ceramic Garnet Gamma-Ray Spectrometer With Directionality

We have developed a handheld γ -ray spectrometer based on 1024 pixels, 2.8mm×2.8mm×6 mm in size, of gadolinium–yttrium–gallium–aluminum garnet (GYGAG) ((Gd,Y,Ce) 3 (Ga,Al) 5 O 12 ) ceramic scintillator (total of 48-cm 3 detector volume) coupled to silicon photodiode (SiPD) arrays. The SiPD arrays and readout ASIC, originally developed for medical imaging applications, have been adapted for portability in a lightweight box with heatsink and thermoelectric cooling. Custom readout firmware for γ-ray spectroscopy has been implemented, and a system user interface was developed that runs on an Android tablet. Here, we have optimized the processing of the GYGAG(Ce), the pixel optical coupling, and electronics readout parameters to obtain single pixel energy resolution as good as R(662keV)=3.1 % full-width at half-maximum and full device resolution with singles events from all pixels summed of 4.5%. When Compton-summed events are included, full-energy peak efficiency increases by ~2× , and R(662keV)=4.7 % is obtained for the full device. The pixelated architecture is leveraged to locate point sources of radiological materials using Compton imaging and active masking techniques. Directional detection of a 1 mCi Cs-137 source at 10 m can be made to ±10° in ~2 s.

42 ENGINEERING↗

Spatial Characterization of PACE OCI ETU Using Time-Delay Mode

The OCI (Ocean Color Instrument) is the main sensor on the upcoming PACE (Plankton Aerosol Cloud ocean Ecosystem) mission. OCI has two hyperspectral CCD sensors covering 340nm to 885nm and 9 SWIR (Short Wave IR) bands from 940nm to 2260nm. SWIR bands have nominal 1km ground pixel size and CCD bands have native 1/8 km ground pixel size in diagnostic mode that will be aggregated into 1km pixels to improve SNR and meet the data rate constraints. OCI has a rotating telescope that is synchronized to the readout of the CCD and SWIR detectors. Full pre-launch system level testing for the OCI ETU (Engineering Test Unit) was completed in June 2021.With time-delayed scan mode, a sub-pixel level time-delay step is applied to the detector readout. This sub-pixel level time-delay step causes a sub-pixel level shift in the start of the data collection. After collecting time-delay step scans with different step sizes, a scan profile with sub-pixel resolution can be constructed. 1/8 and 1/4 of CCD pixel resolutions were achieved using this mode. In this paper, the OCI time-delayed scan mode will be described as well as how it was used to calculate OCI’s high spatial resolution PSF (Point Spread Function), IFOV (instantaneous Field of View), MTF (Modulation Transfer Function), and BBR (Band to Band Registration).

PACE↗

JPSS Science Data Services for the Direct Readout Community

The Suomi National Polar-orbiting Partnership (S-NPP) and Joint Polar Satellite System (JPSS) High Rate Data (HRD) link provides Direct Broadcast data to users in real-time, utilizing their own remote field terminals. The Field Terminal Support (FTS) provides the resources needed to support the Direct Readout communities by providing software, documentation, and periodic updates to enable them to produce data products from SNPP and JPSS. The FTS distribution server will also provide the necessary ancillary and auxiliary data needed for processing the broadcasts, as well as making orbital data available to assist in locating the satellites of interest. In addition, the FTS provides development support for the algorithm and software through GSFC Direct Readout Laboratory (DRL) International Polar Orbiter Processing Package (IPOPP) and University of Wisconsin (UWISC) Community Satellite Processing Package (CSPP), to enable users to integrate the algorithms into their remote terminals. The support the JPSS Program provides to the institutions developing and maintaining these two software packages, will demonstrate the ability to produce ready-to-use products from the HRD link and provide risk reduction effort at a minimal cost. This paper discusses the key functions and system architecture of FTS.

Data Processing↗

Wilbur: A low-cost CCD camera system for MDM Observatory

The recent availability of several 'off-the-shelf' components, particularly CCD control electronics from SDSU, has made it possible to put together a flexible CCD camera system at relatively low cost and effort. The authors describe Wilbur, a complete CCD camera system constructed for the Michigan-Dartmouth-MIT Observatory. The hardware consists of a Loral 2048(exp 2) CCD controlled by the SDSU electronics, an existing dewar design modified for use at MDM, a Sun Sparcstation 2 with a commercial high-speed parallel controller, and a simple custom interface between the controller and the SDSU electronics. The camera is controlled from the Sparcstation by software that provides low-level I/O in real time, collection of additional information from the telescope, and a simple command interface for use by an observer. Readout of the 2048(exp 2) array is complete in under two minutes at 5 e(sup -) read noise, and readout time can be decreased at the cost of increased noise. The system can be easily expanded to handle multiple CCD's/multiple readouts, and can control other dewars/CCD's using the same host software.

Metzger, M. R.↗

Gamma ray spectroscopy employing divalent europium-doped alkaline earth halides and digital readout for accurate histogramming

According to one embodiment, a scintillator radiation detector system includes a scintillator, and a processing device for processing pulse traces corresponding to light pulses from the scintillator, where the processing device is configured to: process each pulse trace over at least two temporal windows and to use pulse digitization to improve energy resolution of the system. According to another embodiment, a scintillator radiation detector system includes a processing device configured to: fit digitized scintillation waveforms to an algorithm, perform a direct integration of fit parameters, process multiple integration windows for each digitized scintillation waveform to determine a correction factor, and apply the correction factor to each digitized scintillation waveform.

36 MATERIALS SCIENCE↗

Radiation-Hard Parallel Readout Circuit for Low-Frequency Voltage Signal Measurements

NASA Goddard Space Flight Center (GSFC) has successfully developed and tested a custom-designed low-noise multi-channel digitizer (MCD) application specific integrated circuit (ASIC) for operation in harsh radiation environments. The MCD-ASIC is optimized for low-frequency and low-voltage signal measurements from sensors and transducers. It has 20 input channels where each channel is comprised of auto-zeroed chopper variable-gain amplifier, post amplifier, and a second order ∑∆ modulator. ∑∆ analog-to-digital converter (ADC) relies on oversampling and noise shaping to achieve high-resolution conversion. However, the MCD-ASIC requires digital filtering and decimation to convert the output single bit streams from the ADC to useful data words. A parallel digital platform such as a field-programmable-gate-array (FPGA) is highly suitable to fully leverage the capabilities of the MCD-ASIC. The FPGA controls the MCD-ASIC via serial peripheral interface (SPI) protocol and acquires data from it. A Python-script communicates with the FPGA board through a USB interface on a cross operating platform. Using this architecture, the system is capable of monitoring up to 20 voltage readout channels simultaneously in a real-time manner. Each channel’s parameters can be programmed independently allowing maximum user versatility. In this paper, we present analysis of the analog front-end, the implementation of the digital processing unit on the FPGA, and provide noise performance results from the MCD-ASIC readout.

ASIC↗

Performance of a broad-band, high-resolution, transition-edge sensor spectrometer for x-ray astrophysics

Future x-ray astrophysics experiments require multiplexed readout of high-fill-factor, kilo-pixel arrays of transition-edge sensors (TESs), with very high spectral resolution over a broad range of energies. In this paper we report on a prototype kilo pixel array of Mo/Au TESs read out with 8-column by 32-row time-division multiplexing (TDM). This system is being used to demonstrate the critical detector and readout technology for ESA’s Athena X-IFU, and when complete will used to laboratory astrophysics experiments. Our array and TDM readout has demonstrated a combined energy resolution, including > 200 pixels, of: 1.95 eV for Ti-K (4.5 keV), 1.97 eV for Mn-K (5.9 keV), 2.16 eV for Co-Kα (6.9 keV), 2.33 eV for Cu-Kα (8 keV), 3.26 eV for Br-Kα (11.9 keV). The 1 sigma error is  0.01 eV for all spectra. These results meet the broad-band resolution requirements for X-IFU.

Stephen J. Smith↗

A radioxenon detection system using CdZnTe, an array of SiPMs, and a plastic scintillator

This paper presents the design and characterization of a prototype compact beta–gamma radioxenon detection system that utilizes a coplanar CdZnTe crystal, an array of SiPMs, and a plastic scintillator. The detector is directly mounted on a custom PCB. The system provides the advantage of room-temperature operation, while being compact, low noise, and with simple readout electronics. Preliminary measurements using 137 Cs, 135 Xe, and 133/133m Xe were conducted to optimize various system parameters to achieve optimal resolution of key photopeaks. The purpose of this research was to explore the potential of these radiation detection elements for use in beta–gamma coincidence applications.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

A Normal Incidence X-ray Telescope (NIXT) sounding rocket payload

Work on the High Resolution X-ray (HRX) Detector Program is described. In the laboratory and flight programs, multiple copies of a general purpose set of electronics which control the camera, signal processing and data acquisition, were constructed. A typical system consists of a phosphor convertor, image intensifier, a fiber optics coupler, a charge coupled device (CCD) readout, and a set of camera, signal processing and memory electronics. An initial rocket detector prototype camera was tested in flight and performed perfectly. An advanced prototype detector system was incorporated on another rocket flight, in which a high resolution heterojunction vidicon tube was used as the readout device for the H(alpha) telescope. The camera electronics for this tube were built in-house and included in the flight electronics. Performance of this detector system was 100 percent satisfactory. The laboratory X-ray system for operation on the ground is also described.

Golub, Leon↗

Using PyBioNetFit to leverage qualitative and quantitative data in biological model parameterization and uncertainty quantification

Data generated in studies of cellular regulatory systems are often qualitative. For example, measurements of signaling readouts in the presence and absence of mutations may reveal a rank ordering of responses across conditions but not the precise extents of mutation-induced differences. Qualitative data are often ignored by mathematical modelers or are considered in an ad hoc manner, as in the study of Kocieniewski and Lipniacki (2013) [Phys Biol 10: 035006], which was focused on the roles of MEK isoforms in ERK activation. In this earlier study, model parameter values were tuned manually to obtain consistency with a combination of qualitative and quantitative data. This approach is not reproducible, nor does it provide insights into parametric or prediction uncertainties. Here, starting from the same data and the same ordinary differential equation (ODE) model structure, we generate formalized statements of qualitative observations, making these observations more reusable, and we improve the model parameterization procedure by applying a systematic and automated approach enabled by the software package PyBioNetFit. We also demonstrate uncertainty quantification (UQ), which was absent in the original study. Our results show that PyBioNetFit enables qualitative data to be leveraged, together with quantitative data, in parameterization of systems biology models and facilitates UQ. These capabilities are important for reliable estimation of model parameters and model analyses in studies of cellular regulatory systems and reproducibility.

59 BASIC BIOLOGICAL SCIENCES↗

Phase-I Trigger Readout Electronics Upgrade for the ATLAS Liquid-Argon Calorimeters

The Phase-I trigger readout electronics upgrade of the ATLAS Liquid Argon calorimeters enhances the physics reach of the experiment during the upcoming operation at increasing Large Hadron Collider luminosities. The new system, installed during the second Large Hadron Collider Long Shutdown, increases the trigger readout granularity by up to a factor of ten as well as its precision and range. Consequently, the background rejection at trigger level is improved through enhanced filtering algorithms utilizing the additional information for topological discrimination of electromagnetic and hadronic shower shapes. Therefore, this paper presents the final designs of the new electronic elements, their custom electronic devices, the procedures used to validate their proper functioning, and the performance achieved during the commissioning of this system.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A 90GHz Bolometer Camera Detector System for the Green Bank Telescope

We describe a close-packed, two-dimensional imaging detector system for operation at 90GHz (3.3mm) for the 100 m Green Bank Telescope (GBT) This system will provide high sensitivity (<1mjy in 1s rapid imaging (15'x15' to 250 microJy in 1 hr) at the world's largest steerable aperture. The heart of this camera is an 8x8 close packed, Nyquist-sampled array of superconducting transition edge sensor bolometers. We have designed and are producing a functional superconducting bolometer array system using a monolithic planar architecture and high-speed multiplexed readout electronics. With an NEP of approx. 2.10(exp 17) W/square root Hz, the TES bolometers will provide fast linear sensitive response for high performance imaging. The detectors are read out by and 8x8 time domain SQUID multiplexer. A digital/analog electronics system has been designed to enable read out by SQUID multiplexers. First light for this instrument on the GBT is expected within a year.

Benford, Dominic J.↗