Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “RADIATION MONITORING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 793 records · Page 44

Application of New CERCLA Five-Year Review Guidance at Hanford - 16403

Under CERCLA, the implementation of remedial actions established in records of decision (ROD) are required to be reviewed every five years to evaluate their effectiveness in protecting human health and the environment. Past reviews have included evaluation of actions that were not implemented under existing RODs and, therefore, not subject to the requirement. While commendable for its transparency, discussing these out-of-scope actions created confusion and elicited comments that required time and effort to resolve. The fourth CERCLA Five Year Review (FYR) at the Hanford Site embraces the EPA guidance designed to streamline the process and focuses on the specific objectives of the review. This guidance and the training materials developed jointly by multiple federal agencies including EPA, DOE, DOD, and Department of the Interior (DOI), demonstrate a focused approach to the FYR process and offer real-world examples for streamlining this important document. This paper discusses the focused approach and process changes implemented at the Hanford Site that reduced the size and complexity of the document and provided the DOE, Richland Operations Office, with an efficient, effective template for preparing subsequent reviews. One key change was a thorough evaluation of what operable units were discussed and what operable units were not discussed in the five-year review. This process resulted in a reduction of 14 operable unit discussions. Additionally, extensive referencing of previously published CERCLA documents including closure reports and periodic groundwater monitoring reports minimized the amount of analytical data tables necessary to support the discussion. The Hanford five year review made good use of technology and provided internet links to existing documents where detailed information and voluminous analytical data reside. This eliminated the use of extensive data tables and summaries. The resulting five protectiveness determinations include: 1) 'Protective' which is used when there is sufficient data to conclude that the remedy is functioning as intended; 2) 'Protective in the short term' which is used when the data and/or documentation review raises issues that could affect future protectiveness; 3) 'Will be protective' which is used when the remedy under construction is anticipated to be protective on completion; 4) 'Protectiveness deferred' which is typically used when additional information is needed; and 5) 'Not protective' which is used when risks are not under control. Reviewing only on the appropriate operable units, and supporting the analysis of remedy performance with focused data, the resulting protectiveness determinations and overall effectiveness of the document were significantly improved. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

The INFODEM Information Centre at CEA Marcoule: A Unique Information Tool in Europe About Nuclear Decommissioning - 16217

In September 2014, the French Alternative Energies and Atomic Energy Commission (CEA) inaugurated a unique information center focused on decommissioning of its nuclear facilities. This facility, named INFODEM information center, is inside the main building of the G1 nuclear reactor at Marcoule, a nuclear site in the south of France with world-recognized expertise in decommissioning. Constructed in the 1950's, the G1 reactor was the first industrial-scale reactor for plutonium production in France; it was also used to produce electricity. Operations ceased in 1968, and it was progressively dismantled (through removal of fuel and main components) and placed in monitoring status. In the 1980s, mockups of fuel cycle process equipment were built under a temporary mission to support development activities for the La Hague reprocessing plant. When that ended, further dismantling occurred, and during 1996 through 2010, the site established itself as a reference example for worldwide nuclear dismantling activities. In 2012, the project to establish an information center at the reactor began, targeting three main audiences: the public, agency personnel and politicians, and technical professionals. Considerable thought went into the facility design, to address the interests and information needs of these three audiences. The INFODEM concept extended over 800 square meters (about 960 square yards), to host an informative tour addressing several major themes: CEA's D and D strategy, programs, skills, tools and methodologies and 'everyday life' on decommissioning projects. Illustrating its unique value and considerable success, INFODEM received the Public Information Prize from the French Nuclear Energy Society (SFEN) in June 2015. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

SU-E-T-604: Dosimetric Dependence On the Collimator Angle in Prostate Volumetric Modulated Arc Therapy

Purpose: The purpose of this study is to investigate the dose-volume variations of planning target volume (PTV) and organs-at-risk (OARs) in prostate volumetric modulated arc therapy (VMAT) when using different collimator angles. It is because collimator angle awareness is essential for planner to produce an optimal prostate VMAT plan in a rational time. Methods: Single-arc VMAT plans at different collimator angles (0o, 15o, 30o, 45o, 60o, 75o and 90o) were created systematically using a Harold heterogeneous pelvis phantom. For each change of collimator angle, a new plan was re-optimized for that angle. The prescription dose was 78 Gy per 39 fractions. Conformity index (CI), homogeneity index (HI), gradient index, machine monitor unit, dose-volume histogram, the mean and maximum doses of the PTV were calculated and analyzed. On the other hand, dose-volume histogram, the mean and maximum doses of the OARs such as bladder, rectum and femoral heads for different collimator angles were determined from the plans. Results: There was no significance difference, based on the plan dose-volume evaluation criteria, found in the VMAT optimizations for all studied collimator angles. Higher CI and lower HI were found for the 45o collimator angle. In addition, the 15o collimator angle provided lower HI similar to the 45o collimator angle. The 75o and 90o collimator angle were found good for the rectum sparing, and the 75o and 30o collimator angle were found good for the right and left femur sparing, respectively. The PTV dose coverage for each plan was comparatively independent of the collimator angle. Conclusion: The dosimetric results in this study are useful to the planner to select different collimator angles to improve the PTV coverage and OAR sparing in prostate VMAT.

60 APPLIED LIFE SCIENCES↗

SISTec: Mathematical Calibration of Large Clearance Monitors - 18265

One major path for clearance of large amount of waste arising from the decommission of nuclear power plants is based on measurement with large clearance monitors (also known as free release measurement facilities). These devices utilize multi-detector plastic scintillator arrays (large clearance monitors can consist of up to 24 plastic scintillators) to offer both, extremely low minimum detectable activities (MDA) and short measurement times for waste packages weighing up to one metric ton. However, a major problem with these devices is to obtain nuclide specific efficiencies, especially for geometrically complex large waste packages. Normal procedure for estimating the efficiency is to device dummy waste packages and attach point sources with well-known activities to unfavourable positions in these packages. In accordance with this procedure, calibration factors can be derived in a radiological conservative way. Devising such test dummies is not always possible and the procedure is prone to generating large measurement uncertainties. In this publication, we propose a new method to derive calibration factors by means of the Los Alamos National Laboratory (LANL) simulation tool Monte Carlo N-Particle (MCNP) and a statistical-phenomenological model for the detector characterization. In a multi-step approach, first the detector response for a distribution of activity in a waste package is calculated and subsequently the detectors are mathematically characterized. Applying state of the art statistical and optimizing procedures, parameters for the detector response are derived in a self-consistent way. This also allows to rigorously propagate the uncertainties to the final calculated calibration factors according to the Guide to the Expression of Uncertainty in Measurement (GUM supplement 1). To validate the derived parameters for the detector characterization a minimally invasive experimental setup was devised and installed into the large clearance monitor. It consisted of an aluminum swivel arm which could position point sources to the relevant coordinates. The so collected measurement data not only allowed to investigate the precision of the calculated calibration factors, but also to probe the location of concentrated activity sources in the waste package. Furthermore, data on measurements with dummy waste packages were collected to test the reproducibility of well-known calibration factors. We present the software tool SIStec, which will provide an intuitive user-interface to generate and simulate waste package models and execute the above-mentioned method. Using SIStec, different scenarios for the distribution of activity in the waste package can be probed. This will also allow to optimize the clearance process on various levels. For example, measurement time for pre-measurements can be reduced in exchange for unfavourable calibration factors, which would still allow to meet the regulator limits for clearance. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Classification and imaging of spent nuclear fuel dry casks using cosmic ray muons - 132

The present work explores alternative approaches for in situ monitoring with near real-time data analysis and imaging of dry casks using muons. Monitoring can provide useful signals about the cask contents in a yes/no decision format faster and with fewer muons than traditional imaging. Imaging can be performed as a second step in this process if specific information about the location of the fuel assemblies is needed. To explore and analyze these two modalities, simulations of muon scattering and displacement were performed for various scenarios, including vertical and horizontal fully loaded dry casks, half-loaded dry casks, dry casks with one row of fuel assemblies missing, dry casks with one fuel assembly missing, and empty dry casks. This work demonstrates monitoring can provide fast and reliable indication about the contents of the cask. For 100,000 muons, a few minutes of measurement time with a 3.6 m{sup 2} detector at a 45 deg. zenith angle, 90% detection probability for missing fuel assemblies can be achieved with a false alarm rate lower than 1%. If a positive signal is detected, then longer measurements can be performed and coupled with muon imaging algorithms to determine the location of missing nuclear material. In these cases, transmission muon radiography can produce images of acceptable resolution for all scenarios. In the horizontal dry cask case, all scenarios can be identified and separated adequately. In the vertical dry cask case, similar conclusions can be drawn, but because of shadowing from other fuel assemblies, the location of a missing fuel assembly cannot be identified in the 2-D transmission map. However, views from different directions may resolve this. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Full-Scale Vessel Testing for the Hanford Waste Treatment and Immobilization Plant - 18333

Concerns over the mixing performance of the planned pulse jet mixed (PJM) vessels for high-solids applications in the Hanford Waste Treatment and Immobilization Plant (WTP) Pretreatment (PT) Facility, led to the development of a standard high-solids vessel (SHSV) design and full-scale vessel testing program. The SHSV is intended as a potential replacement for several high-level waste feed receipt and lag storage vessels (High-Level Waste Facility lag storage and feed blending process), ultrafiltration feed preparation vessels (ultrafiltration process system), and plant wash vessels (plant wash and disposal system). The SHSV concept uses multiple smaller vessels (60 500 L - 79 500 L nominal batch size) to replace larger vessels, providing redundancy, improved mixing (PJM design and spargers), monitoring (multi-level bubblers), reduced material at risk, and improved structural features. The SHSV also requires qualification of a single vessel design for high solids Newtonian and non-Newtonian slurry processing, rather than having to qualify earlier multiple vessel designs. An Integrated Technical Team consisting of the U.S. Department of Energy, Bechtel National, Inc., and independent experts was established to accelerate and provide oversight and direction of the test program and SHSV qualification. Qualification of the SHSV for mixing has now been achieved through a comprehensive full-scale vessel testing program conducted in 2017 with a prototypic SHSV under a set of most adverse design conditions, in conjunction with additional engineering analyses. This paper will present an overview of the SHSV, results from the three-phase full-scale vessel test and qualification program completed in September 2017, and the management program to achieve resolution of the PJM mixing technical issue. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

SU-E-T-405: Robustness of Volumetric-Modulated Arc Therapy (VMAT) Plans to Systematic MLC Positional Errors

Purpose: To evaluate the dosimetric impact of systematic MLC positional errors (PEs) on the quality of volumetric-modulated arc therapy (VMAT) plans. Methods: Five patients with head-and-neck cancer (HN) and five patients with prostate cancer were randomly chosen for this study. The clinically approved VMAT plans were designed with 2–4 coplanar arc beams with none-zero collimator angles in the Pinnacle planning system. The systematic MLC PEs of 0.5, 1.0, and 2.0 mm on both MLC banks were introduced into the original VMAT plans using an in-house program, and recalculated with the same planned Monitor Units in the Pinnacle system. For each patient, the original VMAT plans and plans with MLC PEs were evaluated according to the dose-volume histogram information and Gamma index analysis. Results: For one primary target, the ratio of V100 in the plans with 0.5, 1.0, and 2.0 mm MLC PEs to those in the clinical plans was 98.8 ± 2.2%, 97.9 ± 2.1%, 90.1 ± 9.0% for HN cases and 99.5 ± 3.2%, 98.9 ± 1.0%, 97.0 ± 2.5% for prostate cases. For all OARs, the relative difference of Dmean in all plans was less than 1.5%. With 2mm/2% criteria for Gamma analysis, the passing rates were 99.0 ± 1.5% for HN cases and 99.7 ± 0.3% for prostate cases between the planar doses from the original plans and the plans with 1.0 mm MLC errors. The corresponding Gamma passing rates dropped to 88.9 ± 5.3% for HN cases and 83.4 ± 3.2% for prostate cases when comparing planar doses from the original plans and the plans with 2.0 mm MLC errors. Conclusion: For VMAT plans, systematic MLC PEs up to 1.0 mm did not affect the plan quality in term of target coverage, OAR sparing, and Gamma analysis with 2mm/2% criteria.

60 APPLIED LIFE SCIENCES↗

SU-E-T-513: Investigating Dose of Internal Target Volume After Correcting for Tissue Heterogeneity in SBRT Lung Plans with Homogeneity Calculation

Purpose It was recommended to use the prescription of 54 Gy/3 with heterogeneity corrections for previously established dose scheme of 60 Gy/3 with homogeneity calculation. This study is to investigate dose coverage for the internal target volume (ITV) with and without heterogeneity correction. Methods Thirty patients who received stereotactic body radiotherapy (SBRT) to a dose of 60 Gy in 3 fractions with homogeneous planning for early stage non-small-cell lung cancer (NSCLC) were selected. ITV was created either from 4DCT scans or a fusion of multi-phase respiratory scans. Planning target volume (PTV) was a 5 mm expansion of the ITV. For this study, we recalculated homogeneous clinical plans using heterogeneity corrections with monitor units set as clinically delivered. All plans were calculated with 3 mm dose grids and collapsed cone convolution algorithm. To account for uncertainties from tumor delineation and image-guided radiotherapy, a structure ITV2mm was created by expanding ITV with 2 mm margins. Dose coverage to the PTV, ITV and ITV2mm were compared with a student paired t-test. Results With heterogeneity corrections, the PTV V60Gy decreased by 10.1% ± 18.4% (p<0.01) while the maximum dose to the PTV increased by 3.7 ± 4.3% (p<0.01). With and without corrections, D99% was 65.8 ± 4.0 Gy and 66.7 ± 4.8 Gy (p=0.15) for the ITV, and 63.9 ± 3.4 Gy and 62.9 ± 4.6 Gy for the ITV2mm (p=0.22), respectively. The mean dose to the ITV and ITV2mm increased 3.6% ± 4.7% (p<0.01) and 2.3% ± 5.2% (p=0.01) with heterogeneity corrections. Conclusion After heterogeneity correction, the peripheral coverage of the PTV decreased to approximately 54 Gy, but D99% of the ITV and ITV2mm was unchanged and the mean dose to the ITV and ITV2mm was increased. Clinical implication of these results requires more investigation.

60 APPLIED LIFE SCIENCES↗

SU-E-T-85: Comparison of Treatment Plans Calculated Using Ray Tracing and Monte Carlo Algorithms for Lung Cancer Patients Having Undergone Radiotherapy with Cyberknife

Purpose: The latest publications indicate that the Ray Tracing algorithm significantly overestimates the dose delivered as compared to the Monte Carlo (MC) algorithm. The purpose of this study is to quantify this overestimation and to identify significant correlations between the RT and MC calculated dose distributions. Methods: Preliminary results are based on 50 preexisting RT algorithm dose optimization and calculation treatment plans prepared on the Multiplan treatment planning system (Accuray Inc., Sunnyvale, CA). The analysis will be expanded to include 100 plans. These plans are recalculated using the MC algorithm, with high resolution and 1% uncertainty. The geometry and number of beams for a given plan, as well as the number of monitor units, is constant for the calculations for both algorithms and normalized differences are compared. Results: MC calculated doses were significantly smaller than RT doses. The D95 of the PTV was 27% lower for the MC calculation. The GTV and PTV mean coverage were 13 and 39% less for MC calculation. The first parameter of conformality, as defined as the ratio of the Prescription Isodose Volume to the PTV Volume was on average 1.18 for RT and 0.62 for MC. Maximum doses delivered to OARs was reduced in the MC plans. The doses for 1000 and 1500 cc of total lung minus PTV, respectively were reduced by 39% and 53% for the MC plans. The correlation of the ratio of air in PTV to the PTV with the difference in PTV coverage had a coefficient of −0.54. Conclusion: The preliminary results confirm that the RT algorithm significantly overestimates the dosages delivered confirming previous analyses. Finally, subdividing the data into different size regimes increased the correlation for the smaller size PTVs indicating the MC algorithm improvement verses the RT algorithm is dependent upon the size of the PTV.

60 APPLIED LIFE SCIENCES↗

SU-E-T-809: Volumetric Modulated Arc Radiotherapy Vs. Intensity-Modulated Radiotherapy for Locally Advanced Laryngeal Carcinoma: A Dosimetric Study

Purpose: To compare volumetric modulated arc radiotherapy (VMAT) technique with fixed-gantry intensity-modulated radiotherapy (IMRT) technique for locally advanced laryngeal carcinoma. Methods: CT datasets of eleven patients were included. Dual-arc VMAT and 7-field IMRT plans, which were created based on the Eclipse treatment planning system, were compared in terms of dose-volume parameters, conformity index (CI) and homogeneity index (HI) of planning target volume (PTV), as well as organ-at-risk (OAR) sparing, planning time, monitor units (MUs) and delivery time. Results: Compared with the IMRT plans, the VMAT plans provided lower D2% and better CI/HI for the high-risk PTV (PTV1), and provided better CI and comparable HI for the low-risk PTV (PTV2). Concerning the OAR sparing, the VMAT plans demonstrated significantly lower Dmax of the spinal cord (planning OAR volume, PRV) and brainstem (PRV), as well as lower Dmean and V30Gy of the right parotid. No significant differences were observed between the two plans concerning the doses delivered to the thyroid, carotid, oral cavity and left parotid. Moreover, the VMAT planning (147 ± 18 min) consumed 213% more time than the IMRT planning (48 ± 10 min). The MUs of the VMAT plans (556 ± 52) were 64% less than those of the IMRT plans (1684 ± 409), and the average delivery time (2.1 ± 0.1 min) was 66% less than that of the IMRT plans (6.3 ± 0.7 min). Conclusion: Compared with the IMRT technique, the VMAT technique can achieve superior target dose distribution and better sparing of the spinal cord, brainstem and right parotid, with less MUs and less delivery time. It is recommended for the radiotherapy of locally advanced laryngeal carcinoma.

60 APPLIED LIFE SCIENCES↗

SU-E-T-150: End to End Tests On the First Clinical EDGETM

Purpose: To quantify the sub millimeter overall accuracy of EDGETM, the dedicated linac based SRS/SABR treatment platform from Varian, using a novel End-to-End (E2E) test phantom. Methods: The new E2E test phantom developed by Varian consists of a cube with an outer dimension of 15x15x15 cm3. The phantom is equipped with an exchangable inner cube (7×7×7 cm3) to hold radiochromic films or a tungsten ball (diameter = 5 mm) for Winston-Lutz tests. 16 ceramic balls (diameter = 5 mm) are embedded in the outer cube. Three embedded Calypso transponders allow for Calypso based monitoring. The outer surface of the phantom is tracked using the Optical Surface Monitoring System (OSMS). The phantom is positioned using kV, MV and CBCT images. A simCT of the phantom was acquired and SRS/SABR plans were treated using the new phantom on the first clinical installed EDGETM. As a first step a series of EPID based Winston-Lutz tests have been performed. As a second step the calculated dose distribution applied to the phantom was verified with radiochromic films in orthogonal planes. The measured dose distribution is compared with the calculated (Eclipse) one based on the known isocenter on both dose distributions. The geometrical shift needed to match both dose distributions is the overall accuracy and is determined using dose profiles, isodose lines or gamma pass rates (3%, 1 mm). Results: Winston-Lutz tests using the central tungsten BB demonstrated a targeting accuracy of 0.44±0.18mm for jaw (2cm × 2cm) defined 0.39±0.19mm for MLC (2cm × 2cm) defined and 0.37±0.15mm for cone (12.5 mm) defined fields. A treated patient plan (spinal metastases lesion with integrated boost) showed a dosimetric dose localization accuracy of 0.6mm. Conclusion: Geometric and dosimetric E2E tests on EDGETM, show sub-millimeter E2E targeting and dose localisation accuracy.

60 APPLIED LIFE SCIENCES↗

Short-lived species detection of nitrous acid by external-cavity quantum cascade laser based quartz-enhanced photoacoustic absorption spectroscopy

Spectroscopic detection of short-lived gaseous nitrous acid (HONO) at 1254.85 cm{sup −1} was realized by off-beam coupled quartz-enhanced photoacoustic spectroscopy (QEPAS) in conjunction with an external cavity quantum cascade lasers (EC-QCL). High sensitivity monitoring of HONO was performed within a very small gas-sample volume (of ∼40 mm{sup 3}) allowing a significant reduction (of about 4 orders of magnitude) of air sampling residence time which is highly desired for accurate quantification of chemically reactive short-lived species. Calibration of the developed QEPAS-based HONO sensor was carried out by means of lab-generated HONO samples whose concentrations were determined by direct absorption spectroscopy involving a ∼109.5 m multipass cell and a distributed feedback QCL. A minimum detection limit (MDL) of 66 ppbv (1 σ) HONO was achieved at 70 mbar using a laser output power of 50 mW and 1 s integration time, which corresponded to a normalized noise equivalent absorption coefficient of 3.6 × 10{sup −8 }cm{sup −1} W/Hz{sup 1/2}. This MDL was down to 7 ppbv at the optimal integration time of 150 s. The corresponding 1σ minimum detected absorption coefficient is ∼1.1 × 10{sup −7 }cm{sup −1} (MDL ∼ 3 ppbv) in 1 s and ∼1.1 × 10{sup −8 }cm{sup −1} (MDL ∼ 330 pptv) in 150 s, respectively, with 1 W laser power.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

SU-E-T-326: The Oxygen Saturation (SO2) and Breath-Holding Time Variation Applied Active Breathing Control (ABC)

Purpose: To study the oxygen saturation (SO2) and breath-holding time variation applied active breathing control (ABC) in radiotherapy of tumor. Methods: 24 volunteers were involved in our trials, and they all did breath-holding motion assisted by ELEKTA Active Breathing Coordinator 2.0 for 10 times respectively. And the patient monitor was used to observe the oxygen saturation (SO2) variation. The variation of SO2, and length of breath-holding time and the time for recovering to the initial value of SO2 were recorded and analyzed. Results: (1) The volunteers were divided into two groups according to the SO2 variation in breath-holding: A group, 14 cases whose SO2 reduction were more than 2% (initial value was 97% to 99%, while termination value was 91% to 96%); B group, 10 cases were less than 2% in breath-holding without inhaling oxygen. (2) The interfraction breath holding time varied from 8 to 20s for A group compared to the first breath-holding time, and for B group varied from 4 to 14s. (3) The breathing holding time of B group prolonged mean 8s, compared to A group. (4) The time for restoring to the initial value of SO2 was from 10s to 30s. And the breath-holding time shortened obviously for patients whose SO2 did not recover to normal. Conclusion: It is very obvious that the SO2 reduction in breath-holding associated with ABC for partial people. It is necessary to check the SO2 variation in breath training, and enough time should be given to recover SO2.

60 APPLIED LIFE SCIENCES↗

Development of an Automated Remedy Performance Evaluation Program - 13622

Performance monitoring is a vital element of groundwater remediation. Unfortunately, the enormous efforts and costs that are expended procuring, managing, processing and storing monitoring data are often not subject to correspondingly rigorous evaluation. This is despite the fact that many steps in the process are predictable and are repeated many times over the remedy life cycle. At the Department of Energy (DOE) Hanford Site, a program is underway to automate many of these steps - processing, formatting any analyzing large volumes of heterogeneous data associated with the operation of several groundwater pump-and-treat (P and T) and in-situ remedies. The Automated Remedy Performance Evaluation Program (ARPEP) was developed from a work-flow process designed to deliver (a) monthly data summaries and preliminary analysis, (b) quarterly performance assessments, and (c) annual roll-up analyses that detect changes in long-term monitoring datasets and support remedy optimization. The intent of the ARPEP is to provide detailed, systematic and traceable data summaries, depictions and analyses that can be used by project scientists to complete their evaluation of remedy performance. The ARPEP work-flow was formalized following extensive review of applicable guidance, regulation and industry standards. The ARPEP incorporates disparate data types collected over different frequencies, such as water levels and pumping rates recorded every minute, and groundwater sample results obtained on quarterly, annual or irregular intervals. The data are processed, reduced to frequencies suitable for assessment, and combined in various ways leading to performance indicators such as (a) pumped well capacities and system downtime that reflect operational performance; (b) hydraulic gradients and areas of hydraulic containment that reflect hydraulic performance; and (c) time-series (longitudinal) and geo-statistical (spatial) trend analyses that reflect progress toward attainment of Remedial Action Objectives (RAOs). The entire sequence of data processing and analysis is undertaken within the R programming environment, an open-source environment for statistical computing and graphics, and is summarized in a comprehensive PDF project report. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Endpoint Evaluation for 200-PW-1 Operable Unit Soil Vapor Extraction, Hanford Site, Washington - 16478

On the Central Plateau of the Hanford Site in semi-arid southeast Washington State, the 216-Z-9 Trench, 216-Z-1A Tile Field, and 216-Z-18 Crib were used from 1955 to 1973 for soil column disposal of liquid wastes containing carbon tetrachloride. The geological setting underneath these disposal areas consists of an approximately 70 m thick vadose zone with a nominally 5 m thick low-permeability layer at a depth of 30 m. Infiltration of the liquid waste through the vadose zone to the groundwater was driven by the liquid volume introduced during disposal. Carbon tetrachloride readily volatilises in the vadose zone, making soil vapor extraction (SVE) the preferred remediation technology. Between 1992 and 2012, SVE recovered 80,107 kg of carbon tetrachloride from the vadose zone below the three waste sites. Of this total recovery, 93 percent was removed during the first 5 years of operations. The last 7 percent was recovered in the last 16 years of operation. In 2011, a final cleanup level of 100 ppmv for carbon tetrachloride in soil vapor was established in the record of decision for the 200-PW-1 Operable Unit, which includes the three carbon tetrachloride waste sites. The final cleanup decision specified that soil vapor concentrations and the cleanup level would be further refined and assessed in the future to ensure groundwater protection. A subsequent treatability test was conducted and the results were used to further refine the definition of vadose zone source conditions that are protective of groundwater. Based on this treatability test, predictions indicate that current and future vadose zone conditions will meet groundwater protection objectives. SVE operations were not performed in 2013, 2014, and 2015, and soil vapor concentrations in all SVE wells (and all but two monitoring probes installed using direct-push technology) remained below the 100 ppmv cleanup level during this time. SVE endpoint guidance was prepared in 2013 as a joint effort between Pacific Northwest National Laboratory, U.S. Army Corps of Engineers, and U.S. Environmental Protection Agency. This SVE guidance was used to develop a path forward for the 200-PW-1 Operable Unit SVE remedy. The guidance asks the following questions: 1. Are data collected to date adequate to support a well-defined conceptual site model? 2. Have remediation goals (cleanup levels) been defined? 3. Are environmental pathways and risk understood well enough to support site closeout? 4. Will remaining contamination in the vadose zone cause groundwater cleanup levels to be exceeded? If the answer to the first three questions is 'Yes', and the answer to the fourth question is 'No', then the site is ready for closure. At this time, the site has compiled appropriate information to answer these questions to support a remedy decision to terminate SVE operations. The U.S. Environmental Protection Agency recently provided concurrence that termination of SVE operations within the 200-PW-1 Operable Unit is appropriate. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

SU-E-T-263: Development of Dose Monitor Unit Calculation Using Clarkson Integration for Proton Beam Therapy Using Beam-Wobbling System

Purpose: The purpose of the present study is to develop a calculation method of dose-calibration-factor using Clarkson integration for proton therapy employing the wobbling system and to evaluate accuracy of the calculation by comparison between calculations and measurements. Methods: CF and CALF stand for a dose-calibration-factor and a dose per monitor unit (MU), respectively. A measured dose-calibration-factor CFmeas is defined as a ratio of the measured dose per monitor unit in a patient-specific condition CALFpat to the measured dose per MU in a reference beam condition CALFref. The CFcalc is a product of three factors: CF1, CF2 and CF3. The CF1 and CF2 are a factor reflecting the effect of common beam delivery devices and that of patient specific devices and parameter (an aperture collimator, a range compensator and an air gap), respectively. The CF1 was obtained by interpolation using measured data. The CF2 was calculated using the Simplified Monte Carlo (SMC) method. The SMC method calculates a dose distribution by tracing individual protons and by using a measured Bragg curve in water. The CF3 representing the correction factor of field size effect was obtained by using the Clarkson integration. We compared the calculated and measured CF values for 20 prostate cases. Results: Field size correction was found to be important. The calculations reproduce the measurement results within an error of ±2.0%, except for a few cases. The error was about –3.1% for the small field area of less than19 square centimeters. Conclusion: We have developed a calculation method of dose-calibration-factor. Calculations agreed with measurements within ±2.0% for 90% of 20 prostate cases. Except for a small field size cases, the calculation method can be applied to determine the dose-calibration–factor for majority cases of prostate cancer.

60 APPLIED LIFE SCIENCES↗

SU-E-T-325: The New Evaluation Method of the VMAT Plan Delivery Using Varian DynaLog Files and Modulation Complexity Score (MCS)

Purpose: The aim of the study is to evaluate the use of Varian DynaLog files to verify VMAT plans delivery and modulation complexity score (MCS) of VMAT. Methods: Delivery accuracy of machine performance was quantified by multileaf collimator (MLC) position errors, gantry angle errors and fluence delivery accuracy for volumetric modulated arc therapy (VMAT). The relationship between machine performance and plan complexity were also investigated using the modulation complexity score (MCS). Plan and Actual MLC positions, gantry angles and delivered fraction of monitor units were extracted from Varian DynaLog files. These factors were taken from the record and verify system of MLC control file. Planned and delivered beam data were compared to determine leaf position errors and gantry angle errors. Analysis was also performed on planned and actual fluence maps reconstructed from those of the DynaLog files. This analysis was performed for all treatment fractions of 5 prostate VMAT plans. The analysis of DynaLog files have been carried out by in-house programming in Visual C++. Results: The root mean square of leaf position and gantry angle errors were about 0.12 and 0.15, respectively. The Gamma of planned and actual fluence maps at 3%/3 mm criterion was about 99.21. The gamma of the leaf position errors were not directly related to plan complexity as determined by the MCS. Therefore, the gamma of the gantry angle errors were directly related to plan complexity as determined by the MCS. Conclusion: This study shows Varian dynalog files for VMAT plan can be diagnosed delivery errors not possible with phantom based quality assurance. Furthermore, the MCS of VMAT plan can evaluate delivery accuracy for patients receiving of VMAT. Machine performance was found to be directly related to plan complexity but this is not the dominant determinant of delivery accuracy.

60 APPLIED LIFE SCIENCES↗

The Role of Technical Guidance and Analysis Tools in Remedy Decisions, Implementation, and Closure - 18307

Selection, design, and implementation of environmental remedies are conducted under regulatory frameworks that define the activities, communication, and documentation requirements for the remediation process. However, there are site situations that are not well described in the basic regulatory frameworks, and technical guidance and analysis tools can help facilitate remedy decisions and actions. An example where technical guidance and analysis tools are helpful is in the transition from pump-and-treat (P and T) remediation to monitored natural attenuation (MNA). Standard MNA regulatory guidance does not account for a plume initially controlled by P and T hydraulic conditions rather than natural-gradient conditions. For instance, MNA guidance discusses demonstrating plume stability as a means to evaluate the suitability of MNA. However, plume stability under long-term natural gradient conditions cannot be directly demonstrated while the plume is being contained by a P and T system. Thus, additional guidance is needed to describe other measures that can be used to support transition from P and T to MNA. As an additional example, standard MNA regulatory guidance is not written to provide suitable information for application to vadose-zone contamination; discussion and examples in the regulatory guidance are predominantly for groundwater. Use of contaminant transport assessments is an important component of vadose-zone remedy decisions where technical guidance and analysis tools can facilitate these decisions. For volatile compounds, the assessment may need to also consider flux to the surface and constraints associated with vapor intrusion. Recent technical guidance and associated analysis tools provide sites with approaches to support remedy decisions for the above conditions. In particular, these recent approaches target developing and implementing P and T and soil vapor extraction remediation exit strategies and facilitating assessment and implementation of remedies for coupled vadose-zone/groundwater contamination. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗