Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Process sensitivity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 793 records · Page 44

The NOL Gap Test: Past, present, and future

A brief history of the development of the gap test is presented with emphasis on accumulated knowledge of how best to use it as a tool to assess relative shock sensitivity of explosives and propellants. Present information about the detonation process in build-up, steady state, and failure is used to show that failure diameter cannot give the desired shock sensitivity assessment. Suggestions are made for improving the test to an experiment. The use of spherical donors, water as attenuator, and camera instrumentation are briefly discussed.

Jacobs, S. J.↗

Analysis of the Optical Design for the SAFIR Telescope

SAFIR, the Single Aperture Far Infra Red Observatory, is a very powerful space mission that will achieve background-limited sensitivity in the far infrared-submillimeter spectral region. Many processes of enormous interest to astronomers can best be studied in this wavelength range, but require the demanding combination of high sensitivity, good angular resolution, and spectroscopic capability. SAFIR is a 10m class telescope to offering good angular resolution, cooled to below 5 K in order to achieve background-limited sensitivity, and equipped with a complement of large-format cameras and broadband spectrometers. Successful operation of such a facility is critically dependent on achieving the level of sensitivity expected, but this is rendered difficult by potential pickup from unwanted sources of radiation. This problem is exacerbated by the fact that the emission from the optical system itself is minimal due to its low temperature, thus emphasizing the importance of minimizing pickup from unwanted astronomical sources of radiation, including the emission from dust in our solar system (analogous to the zodiacal light, hence 'zodi'), and the emission from warm dust in the Milky Way (Galactic 'cirrus').

antenna radiation patterns↗

Molten Salt Electrochemical Reactors Outside of a Glovebox

Molten salt electrochemical reduction (MSER) offers an electrified method for the reduction, refining, and recycling of metals such as iron and metallurgical grade silicon at high efficiency and lower temperatures than traditional methods, which use temperatures >1000C and carbon-based reductants. However, salts appropriate for MSER are moisture and air sensitive, necessitating air-free methods of processing and testing which is often acomplished with a glovebox. Glovebox operations are cumbersome and difficult to troubleshoot reactor issues. We have developed a robust method of testing chloride and carbonate salts in molten salt reactors outside of a glovebox for silicon and carbon production and steel carburization. We highlight a practical guide for glovebox-free testing of molten salt electrochemical reactors to reduce the barriers to performing this type of work. Our aim is to enable other research groups to step into this field with simple and repeatable reactor configurations.

47 OTHER INSTRUMENTATION↗

Spacelab user implementation assessment study. Volume 1: Concept development and evaluation

The total matrix of alternate Spacelab processing concepts and the rejection rationale utilized to reduce the matrix of 243 alternates to the final candidate processing concepts are developed. The work breakdown structure used for the systematic estimation and compilation of integration and checkout resources is presented along with descriptors of each element. Program models are provided of the space transportation system, the Spacelab, the orbiter, and the ATL that were used as the basis for the study trades, analyses, and optimizations. Resource requirements for all processing concepts are summarized along with the optimizations of the processing concepts. Concept evaluations including flight-rate sensitivities of the GSE, facilities, Spacelab hardware elements, and personnel are delineated. An analysis is presented of the applicability of the candidate concepts to potential spacelab users. The impact of the use of the western test range as an orbiter/spacelab launch site on the candidate processing concepts is evaluated. An assessment of the geographical co-location of experiment, Spacelab, and orbiter-cargo integration is included. Ownership options of the support module/system igloo are discussed.

Source record↗

Sensitive Top-Down Proteomics Analysis of a Low Number of Mammalian Cells Using a Nanodroplet Sample Processing Platform

Top-down proteomics is a powerful tool for characterizing genetic variations and post-translational modifications at intact protein level. That being said, one significant technical gap of top-down proteomics is the inability to analyze low amount of biological samples, which limits its access to isolated rare cells, fine-needle aspiration biopsies, and tissue substructures. Herein, we developed an ultrasensitive top-down platform by incorporating a microfluidic sample preparation system, termed nanoPOTS (Nanodroplet Processing in One pot for Trace Samples), into a top-down proteomics workflow. A unique combination of a nonionic detergent dodecyl-ß-D-maltopyranoside (DDM) with urea as protein extraction buffer significantly improved both protein extraction efficiency and sample recovery. We hypothesize that the DDM detergent improves protein recovery by efficiently reducing non-specific adsorption of intact proteins on container surfaces, while urea serves as a strong denaturant to disrupt noncovalent complexes and release intact proteins for downstream analysis. The nanoPOTS-based top-down platform reproducibly and quantitatively identified ~170 to ~620 proteoforms from ~70 to ~770 HeLa cells containing ~10 to ~115 ng of total protein. A variety of post-translational modifications including acetylation, myristoylation, and iron binding were identified using only less than 800 cells. We anticipate the nanoPOTS top-down proteomics platform will be broadly applicable in biomedical researches, particularly where clinical specimens are not available in amounts amenable to standard workflows.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

New high-sensitivity searches for neutrons converting into antineutrons and/or sterile neutrons at the HIBEAM/NNBAR experiment at the European Spallation Source

The violation of baryon number, , is an essential ingredient for the preferential creation of matter over antimatter needed to account for the observed baryon asymmetry in the Universe. However, such a process has yet to be experimentally observed. The HIBEAM/NNBAR program is a proposed two-stage experiment at the European Spallation Source to search for baryon number violation. The program will include high-sensitivity searches for processes that violate baryon number by one or two units: free neutron–antineutron oscillation () via mixing, neutron–antineutron oscillation via regeneration from a sterile neutron state (), and neutron disappearance (n → n′); the effective process of neutron regeneration () is also possible. The program can be used to discover and characterize mixing in the neutron, antineutron and sterile neutron sectors. The experiment addresses topical open questions such as the origins of baryogenesis and the nature of dark matter, and is sensitive to scales of new physics substantially in excess of those available at colliders. A goal of the program is to open a discovery window to neutron conversion probabilities (sensitivities) by up to three orders of magnitude compared with previous searches. The opportunity to make such a leap in sensitivity tests should not be squandered. The experiment pulls together a diverse international team of physicists from the particle (collider and low energy) and nuclear physics communities, while also including specialists in neutronics and magnetics.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Resonance ionization mass spectrometry for isotopic abundance measurements

Resonance ionization mass spectrometry (RIMS) is a relatively new laser-based technique for the determination of isotopic abundances. The resonance ionization process depends upon the stepwise absorption of photons from the laser, promoting atoms of the element of interest through progressively higher electronic states until an ion is formed. Sensitivity arises from the efficiency of the resonant absorption process when coupled with the power available from commercial laser sources. Selectivity derives naturally from the distinct electronic structure of different elements. This isobaric discrimination has provided the major impetus for development of the technique. Resonance ionization mass spectrometry was used for analysis of the isotopic abundances of the rare earth lutetium. Isobaric interferences from ytterbium severely effect the ability to measure small amounts of the neutron-deficient Lu isotopes by conventional mass spectrometric techniques. Resonance ionization for lutetium is performed using a continuous-wave laser operating at 452 nm, through a sequential two-photon process, with one photon exciting the intermediate resonance and the second photon causing ionization. Ion yields for microgram-sized quantities of lutetium lie between 10(6) and 10(7) ions per second, at overall ionization efficiencies approaching 10(-4). Discrimination factors against ytterbium greater than 10(6) have been measured. Resonance ionization for technetium is also being explored, again in response to an isobaric interference, molybdenum. Because of the relatively high ionization potential for Tc, three-photon, two-color RIMS processes are being developed.

Miller, C. M.↗

Surfactant-assisted one-pot sample preparation for label-free single-cell proteomics

Large numbers of cells are generally required for quantitative global proteome profiling due to surface adsorption losses associated with sample processing. Such bulk measurement obscures important cell-to-cell variability (cell heterogeneity) and makes proteomic profiling impossible for rare cell populations (e.g., circulating tumor cells (CTCs)). Here we report a surfactant-assisted one-pot sample preparation coupled with mass spectrometry (MS) method termed SOP-MS for label-free global single-cell proteomics. SOP-MS capitalizes on the combination of a MS-compatible nonionic surfactant, n-Dodecyl-β-D-maltoside, and hydrophobic surface-based low-bind tubes or multi-well plates for ‘all-in-one’ one-pot sample preparation. This ‘all-in-one’ method including elimination of all sample transfer steps maximally reduces surface adsorption losses for effective processing of single cells, thus improving detection sensitivity for single-cell proteomics. This method allows convenient label-free quantification of hundreds of proteins from single human cells and ~1200 proteins from small tissue sections (close to ~20 cells). When applied to a patient CTC-derived xenograft (PCDX) model at the single-cell resolution, SOP-MS can reveal distinct protein signatures between primary tumor cells and early metastatic lung cells, which are related to the selection pressure of anti-tumor immunity during breast cancer metastasis. The approach paves the way for routine, precise, quantitative single-cell proteomics.

36 MATERIALS SCIENCE↗

A unified approach to aircraft parameter identification

The most accurate identification results are obtained when all three elements of the identification process - the identification algorithm, the control input, and the instrumentation system - are considered in a unified approach. This type of approach for the design of optimal control inputs and for determining the effect of the instrumentation system, in each case with respect to the identification process is discussed. Design of control inputs which optimize the sensitivity of the system output to the unknown parameters is given. Results using these inputs in an extensive simulation of the identification process indicate they perform measurably better than doublet type inputs. A technique is then presented for specifying an optimal instrumentation system or for determining the effect, the instrumentation system has on the accuracy of the parameter estimates.

Stepner, D. E.↗

Design for Carbon Conversion Product Pathways with Nuclear Power Plant Integration (PCC)

Coal is a globally abundant resource that historically has been used for power generation via combustion. As the power industry replaces coal with cleaner methods of generation, energy rich coal could be used in other chemical and fuel applications. This study presents a coal utilization option in which coal combustion is replaced with a carbon-free nuclear power plant and the coal is upgraded to valuable products for a variety of markets. Coal is prepared for conversion first by the pyrolysis process, which will optimize solid, liquid, and gaseous products based on the market size and potential product value, maximizing the monetary value of coal. This process is designed using bituminous coal from the Appalachian region as a basis to provide a pathway to preserve or transition coal-related jobs and create new jobs associated with the clean energy transition. Process modeling will be used to determine each component’s sensitivities, costs, inputs, and outputs Advanced and light-water reactors are considerations to supply the heat, steam, and electricity to the process. This paper focuses on the technical and market analysis used to determine the optimal processes and product pathways for the carbon refinery. Product pathways are on activated carbon, formic acid synthesis, and methanol synthesis for further upgrading to marketable chemical and polymer products.

01 COAL, LIGNITE, AND PEAT↗

Strategies to Improve the Accuracy of Mars-GRAM Sensitivity Studies at Large Optical Depths

The Mars Global Reference Atmospheric Model (Mars-GRAM) is an engineering-level atmospheric model widely used for diverse mission applications. Mars-GRAM s perturbation modeling capability is commonly used, in a Monte-Carlo mode, to perform high fidelity engineering end-to-end simulations for entry, descent, and landing (EDL). It has been discovered during the Mars Science Laboratory (MSL) site selection process that Mars-GRAM when used for sensitivity studies for MapYear=0 and large optical depth values such as tau=3 is less than realistic. A comparison study between Mars atmospheric density estimates from Mars- GRAM and measurements by Mars Global Surveyor (MGS) has been undertaken for locations of varying latitudes, Ls, and LTST on Mars. The preliminary results from this study have validated the Thermal Emission Spectrometer (TES) limb data. From the surface to 80 km altitude, Mars- GRAM is based on the NASA Ames Mars General Circulation Model (MGCM). MGCM results that were used for Mars-GRAM with MapYear=0 were from a MGCM run with a fixed value of tau=3 for the entire year at all locations. Unrealistic energy absorption by uniform atmospheric dust leads to an unrealistic thermal energy balance on the polar caps. The outcome is an inaccurate cycle of condensation/sublimation of the polar caps and, as a consequence, an inaccurate cycle of total atmospheric mass and global-average surface pressure. Under an assumption of unchanged temperature profile and hydrostatic equilibrium, a given percentage change in surface pressure would produce a corresponding percentage change in density at all altitudes. Consequently, the final result of a change in surface pressure is an imprecise atmospheric density at all altitudes. To solve this pressure-density problem, a density factor value was determined for tau=.3, 1 and 3 that will adjust the input values of MGCM MapYear 0 pressure and density to achieve a better match of Mars-GRAM MapYear=0 with MapYears 1 and 2 MGCM output at comparable dust loading. Currently, these density factors are fixed values for all latitudes and Ls. Results will be presented of the work underway to derive better multipliers by including possible variation with latitude and/or Ls. This is achieved by comparison of Mars-GRAM MapYear=0 output with TES limb data. The addition of these density factors to Mars-GRAM will improve the results of the sensitivity studies done for large optical depths. Answers may also be provided to the issues raised in a recent study by Desai(2008). Desai has shown that the actual landing sites of Mars Pathfinder, the Mars Exploration Rovers and the Phoenix Mars Lander have been further downrange than predicted by models prior to landing. Desai s reconstruction of their entries into the Martian atmosphere showed that the models consistently predicted higher densities than those found upon EDL. The solution of this problem would be important to the Mars Program since future exploration of Mars by landers and rovers will require more accurate landing capabilities, especially for the proposed Mars Sample Return mission.

Justh, Hilary L.↗

Mars-GRAM: Increasing the Precision of Sensitivity Studies at Large Optical Depths

The Mars Global Reference Atmospheric Model (Mars-GRAM) is an engineering-level atmospheric model widely used for diverse mission applications. Mars-GRAM's perturbation modeling capability is commonly used, in a Monte-Carlo mode, to perform high fidelity engineering end-to-end simulations for entry, descent, and landing (EDL). It has been discovered during the Mars Science Laboratory (MSL) site selection process that Mars-GRAM, when used for sensitivity studies for MapYear=0 and large optical depth values such as tau=3, is less than realistic. A comparison study between Mars atmospheric density estimates from Mars-GRAM and measurements by Mars Global Surveyor (MGS) has been undertaken for locations of varying latitudes, Ls, and LTST on Mars. The preliminary results from this study have validated the Thermal Emission Spectrometer (TES) limb data. From the surface to 80 km altitude, Mars-GRAM is based on the NASA Ames Mars General Circulation Model (MGCM). MGCM results that were used for Mars-GRAM with MapYear=0 were from a MGCM run with a fixed value of tau=3 for the entire year at all locations. This has resulted in an imprecise atmospheric density at all altitudes. To solve this pressure-density problem, density factor values were determined for tau=.3, 1 and 3 that will adjust the input values of MGCM MapYear 0 pressure and density to achieve a better match of Mars-GRAM MapYear 0 with TES observations for MapYears 1 and 2 at comparable dust loading. The addition of these density factors to Mars-GRAM will improve the results of the sensitivity studies done for large optical depths.

Justh, Hilary L.↗

The Role of Subsurface Flow on Evapotranspiration: A Global Sensitivity Analysis

Abstract Water resources are impacted by water‐energy balance fluxes at the land surface, most notably evapotranspiration ( ET ), the largest component of surface energy balance. While integrated hydrologic models show promise in quantifying the nonlinear dynamics at this interface, the model results are plagued by parametric uncertainties. Given the high computational demand of running multiple parameter spaces of these models, little is known about how these uncertainties propagate into land surface processes. In this work, we perform a global sensitivity analysis by computing Sobol and AMAE indices using a surrogate model constructed with a polynomial chaos expansion to assess the impacts of the subsurface physical properties on ET . We do so by modeling a semisynthetic test case. Our results show that the effects of vertical hydraulic conductivity, porosity, and the water retention curve parameter Van Genuchten α mainly control ET . However, we note that while evaporation ( E ) shows behavior similar to the ET with high sensitivity to the parameters controlling the flow in the unsaturated zone, transpiration ( T ) is very sensitive to the saturated zone parameters and groundwater flow, especially during periods without rain. Our results also show that heterogeneities in land cover impact the flow in the saturated zone. Furthermore, our work demonstrates that reduced‐order models can be developed to make integrated models more accessible for rigorous sensitivity analyses and calibration purposes.

Maina, Fadji Zaouna↗

Selection-bias effects on high-𝑝 𝑇 yield and correlation measurements in oxygen + oxygen collisions

Oxygen + oxygen (O+O) collisions at the BNL Relativistic Heavy Ion Collider (RHIC) and the CERN Large Hadron Collider (LHC) offer a unique experimental opportunity to observe the onset of jet quenching in intermediate relativistic collision systems. As with the smaller proton-nucleus or larger nucleus-nucleus systems, measurements of centrality-selected high-𝑝 T processes in O+O collisions are expected to be sensitive to selection bias effects, which will be necessary to quantify or mitigate before a definitive conclusion on the presence of jet quenching. Using two Monte Carlo heavy-ion event generators, we provide a survey of centrality bias effects on high-𝑝 T yield and correlation measurements. Some highlights of our findings include that (1) bias factors for the accessible kinematic range at RHIC show a nontrivial 𝑝 T dependence, compared to a negligible one at the LHC given the smaller accessible Bjorken-𝑥 range, (2) centrality definitions based on multiplicity are less sensitive to bias effects than those based on the transverse energy, (3) the Angantyr generator gives qualitatively similar but larger-magnitude bias factors than Hijing, and (4) correlation measurements have a much smaller sensitivity to bias effects than do yield measurements. Furthermore, the findings here are intended to guide the experimental design and interpretation of O+O jet quenching and other hard-process measurements.

Hard scattering↗

Scan strategies in EBM-printed IN718 and the physics of bulk 3D microstructure development

Three-dimensional (3D) characterization provides opportunities for understanding processing-structure relationships in additively manufactured (AM) materials. Bulk samples of Inconel 718 were fabricated via electron beam melting (EBM) in order to study microstructural development as a function of energy input and beam scan strategy. TriBeam tomography of bulk Inconel 718 microstructures built under steady-state growth conditions reveals the sensitivity of microstructure formation and evolution to machine process parameters. Here, samples manufactured using a narrow range of energy input per unit build area result in varied grain morphologies and crystallographic textures. Using TRUCHAS, a thermal simulation software, the thermal history of bulk scan strategies was predicted, and combined with a calibrated microstructure-processing map to accurately predict bulk grain morphologies. The solidification parameters and the 3D measured nucleation density are used to predict the transition between columnar and equiaxed grain morphologies, providing a process map to guide AM parameter choices to locally control as-printed microstructure. A two-dimensional metric for characterizing bulk grain morphology was also found to agree well with predictions from the process map calibrated by 3D data. Combined with 3D tomography and thermal modelling, the physics of structure development were understood at a new level of detail with respect to the competing processes of grain nucleation and epitaxial growth.

36 MATERIALS SCIENCE↗

Performance testing of a Compton suppressed coincidence measurements using the Advanced Radionuclide Gamma-spectrOmeter

A Compton-suppressed multidimensional gamma-spectrometer is being developed within the Shallow Underground Laboratory (SUL) at Pacific Northwest National Laboratory (PNNL, USA). This Advanced Radionuclide Gamma-spectrOmeter (ARGO) system consists of two Broad Energy Germanium (BEGe) detectors, surrounded by a 12-detector sodium iodide (NaI) Compton suppression shield, situated inside a low-background lead and copper shield, fitted with a cosmic veto background reduction system. The detector has advanced functionality, including operation in single or combined detector mode, coincidence mode and Compton suppressed coincidence mode. Validation experiments measuring a neutron irradiated natural uranium sample, have demonstrated order of magnitude improvements in gamma detection sensitivity compared to conventional gamma-spectrometry techniques. Importantly this research demonstrates the feasibility of processing and analysing high-multiplicity datasets and the potential for high-sensitivity radionuclide measurements.

ARGO↗

ON PROCESS STABILITY IN WAAM-CMT OF ALUMINUM ALLOYS

Wire-arc additive manufacturing (WAAM) has become a cost-efficient metal additive manufacturing process. However, depositing aluminum with WAAM is challenging due to its sensitivity to heat input (linear energy density), which can cause undesirable surface topology waviness if not controlled. Thus, a process window is needed that can produce stable geometry and deposition conditions while minimizing production times. In this study, 5183 aluminum alloy wire is used to deposit 10-layer walls with varying wire feed speeds (WFS) and traverse speeds (TS) (at a constant WFS/TS ratio) and varying interpass temperature (IPT). In-situ process data consisting of optical contact-tip-workpiece-distance (CTWD) and current/voltage measurements are collected to determine process condition stability throughout the build. Part geometry is measured using a 3D scanner and build porosity is characterized via digital X-ray. A process window is identified that produces stable surface topology and process conditions at a minimal production time.

aluminum alloy↗