Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Performance tests”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 793 records · Page 44

Assessment of the 3430 Building Filtered Exhaust Stack Sampling Probe Location: Stack Verification Following Fan and Air Blender Additions

The velocity uniformity and flow angle results from the 3430 stack verification tests, performed in April 2023, demonstrated that the CFD model results may be used to support the qualification of the stack sampling location. The measured velocity uniformity verification test result was 2.1 %COV. This value is well within the uniformity criterion, which is that the velocity uniformity be =20 %COV. Additionally, this value is well within the criterion that the actual stack measurement must be within 5% of the surrogate stack (i.e., CFD modeled stack); in this case the CFD modeled average result of 2.85 %COV for the nominal operating range of 22,800 cfm to 62,400 cfm. Additionally, the measured average flow angle at the 3430 stack monitor location was 5.6 degrees. The result is =20 degrees, so the criterion is met.

3430 Building↗

ORNL Package Testing Program Overview

Radioactive materials are widespread in our everyday activities which are used in many different types of industries: Consumer products, Medicine, Industry, Energy, and Defense. In the United States there is about 3 million shipments of radioactive materials per year. With radioactive material being very widespread the number of new applications to ship these quantities increases daily. As such, ensuring the safe and secure transport of these materials is paramount, necessitating stringent packaging, transportation, and certification requirements. Shipments of radioactive materials have been made from Oak Ridge National Laboratory (ORNL) for the past 65 years. Since the 1940s ORNL has been at the forefront of the early development of regulations pertaining to the transport of radioactive shipments and associated regulatory testing. The early involvement resulted in ORNL being one of the leaders in the development of regulations and testing standards pertaining to the testing and design of packages. Today all package testing activities are conducted under the Package Testing Program (PTP) at ORNL at the Package Evaluation Facility (PEF). The PTP develops and evaluates testing solutions – ensuring that they are safe, efficient, and meet regulatory requirements ORNL PTP has extensive experience in the regulatory testing of radioactive material packages, supporting certification of Type A, Type, B, Type AF, and special form packages. The PEF serves as a one-stop-shop for design, testing, and certification of a wide variety of packages needed for shipment of radioactive materials. The facility provides the space, expertise, and equipment necessary to conduct rigorous performance testing under both normal and accident conditions or transport environments including free drop, dynamic crush, puncture, penetration, compression, vibration, water spray, water immersion, and thermal test. The PTP remains a key contributor to the safety and compliance of radioactive material transportation. This presentation will provide an overview of the program’s history, capabilities, and its ongoing role in advancing regulatory standards and transportation safety.

Martinez, Oscar [ORNL] (ORCID:0000000181814046)↗

Development of a CMOS SOI Pixel Detector

We have developed a monolithic radiation pixel detector using silicon on insulator (SOI) with a commercial 0.15 {micro}m fully-depleted-SOI technology and a Czochralski high resistivity silicon substrate in place of a handle wafer. The SOI TEG (Test Element Group) chips with a size of 2.5 x 2.5 mm{sup 2} consisting of 20 x 20 {micro}m{sup 2} pixels have been designed and manufactured. Performance tests with a laser light illumination and a {beta} ray radioactive source indicate successful operation of the detector. We also briefly discuss the back gate effect as well as the simulation study.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Model-based approaches to calibration and certification of nondestructive assay systems - 15615

Increasingly, model-based methods founded in physics are employed to calibrate, or extend the calibration of, nondestructive assay (NDA) systems used to characterize materials contaminated with plutonium, uranium, and other radioactive isotopes. In addition, modeling and mathematical methods are used to establish system parameters, correction factors, and measurement uncertainty components in NDA measurements. The methods combine the characteristics of the measurement configuration (detector structure, object shape and dimensions, source-detector distance and orientation, and collimation), generator knowledge of the waste composition, and known physical properties of the system in order to establish these parameters, factors, and components. These methods offer several important benefits over traditional methods used to test, calibrate, operate, and certify radiation measurement systems. First, instruments can be set up and put into service more quickly and correctly using a model-based approach. Second, calibrations can be performed, tested, and modified with reduced use of plutonium and uranium standards when modeling and mathematical methods are employed. Also, modeled approaches avoid calibration error resulting from heterogeneous source distribution. Moreover, the parameters can be installed quickly and simply in an office setting without the need for the safety, security, and safeguards considerations that are present when standards are used. Calibrations can also be tailored to fit unique or nonstandard container configurations (for example, over-packed drums), new container types, or specialized matrices. Finally, when modeling methods are applied, correction factors and measurement uncertainty elements can be developed, tested, and validated relatively quickly and without the need for surrogate matrix materials and a large number of test measurements. A combined gamma and neutron NDA system has recently been moved from Idaho National Laboratory to the TA 55 facility at Los Alamos National Laboratory (LANL). The system will be used to assay transuranic waste packaged in drums. After the move, the system was modified to replace degraded components and improve system performance. Afterwards, it was set up to assay different container types and to extend the calibration range. Model-based approaches were used to adapt the system to its new purpose at LANL. This report will describe the setup, calibration, and certification of the combined system at LANL Included in this discussion will be the measurement applications and details of the measurement methods. The steps in these processes that involved the use of modeling and mathematical calculations to replace or supplement more traditional methods will be identified and discussed. Finally, an overarching discussion of the methods and advantages of model-based methods to establish the properties of NDA systems will be presented. We conclude that validated mathematical methods offer a robust, flexible, and mature approach which is technically defensible from first principle physics. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Report on Electrochemcial Corrosion Testing of 241-SY-102 Grab Samples from the 2012 Grab Sampling Campaign

This report describes the results of the electrochemical testing performed on tank 241-SY-102 (SY-102) grab samples that were collected in support of corrosion mitigation. The objective of the work presented here was to determine corrosion resistance of tank SY-102 to the grab samples collected using electrochemical methods up to 50°C as well as to satisfy data quality objectives. Grab samples were collected at multiple elevations from Riser 003. The electrochemical corrosion testing was planned to consist of linear polarization resistance testing (LPR) and cyclic potentiodynamic polarization (CPP) testing at 50°C. The temperature would be lowered to 40 °C and the test repeated if the CPP curve indicated pitting corrosion at 50°C. If no pitting was indicated by the CPP curve, then a duplicate scan would be repeated at 50°C to confirm the first result. The testing would be complete if the duplicate CPP scan was consistent with the first. This report contains the CPP results of the testing of grab sample 2SY-12-03 and 2SY-12-03DUP composite sample tested under these conditions. There was no indication of pitting at 50°C, and the duplicate scan was in agreement with the first scan. Since no further testing was required, a third scan with a shorter rest time was performed and is present in this report.

36 MATERIALS SCIENCE↗

Development of an x-ray imaging system for the Laser Megajoule (LMJ)

This imaging system aims at recording images of the core size and shape of an imploding deuterium-tritium (DT) microballoon on LMJ inertial confinement fusion (ICF) experiments. Image acquisition is difficult due to the harsh surrounding created by the fusion reaction, which affects system specifications. This one is made of a scintillator, an optical relay, and a CCD camera shielded from the surrounding. The system was tested on different facilities at CEA/DIF, where a spatial resolution of 120 {mu}m was achieved and gamma dose up to 20 rad effects were measured. Setup and performed test are described.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An overview of the activities carried out by the IAEA Technical Working Group on Fast Reactors

The Technical Working Group on Fast Reactors (TWG-FR) of the International Atomic Energy Agency (IAEA) is a group of experts to provide advice and support programme implementation, reflecting a global network of excellence and expertise in the area of advanced technologies and R and O for fast reactors and sub-critical hybrid systems. Consistent with its mandate, the TWG-FR assists in defining and carrying out the Agency's activities in the field of nuclear power technology development for fast reactors and sub-critical hybrid systems. It promotes the exchange of information on national and multi-national programmes and new developments and experience, with the goal to identify and review problems of importance and to stimulate and facilitate cooperation, development and practical application of fast reactors and sub-critical hybrid systems. Finally, the TWG-FR provides Member States with information about the current status and development trends of advanced technologies for fast reactors and sub-critical hybrid systems. The TWG-FR coordinates its activities with other IAEA projects and initiatives, especially those of the Technical Working Group on Nuclear Fuel Cycle Options (TWG-NFCO), the Dept. of Nuclear Safety and Security and, last but not least, the International Project on Innovative Nuclear Reactors and the Fuel Cycle INPRO. It also cooperates with FR-related initiatives implemented within the framework of other international programmes (e.g. GIF, OECD/NEA, ESNII, etc.). The paper presents the recent relevant activities of the TWG-FR as well as the status of the current Coordinated Research Projects jointly carried out by a number of organizations representing the various Member States within the TWG-FR. In particular they concern benchmark analyses of: - the sodium natural circulation tests performed during Phenix End-of-Life experiments; - the sodium natural convection in the upper plenum of the Monju reactor vessel; - an EBR-II Shutdown Heat Removal Test. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

The Effect of the Presence of Ozone on the Lower Flammability Limit (LFL) of Hydrogen in Vessels Containing Savannah River Site High Level Waste - 12387

The Enhanced Chemical Cleaning (ECC) process uses ozone to effect the oxidation of metal oxalates produced during the dissolution of sludge in the Savannah River Site (SRS) waste tanks. The ozone reacts with the metal oxalates to form metal oxide and hydroxide precipitants, and the CO{sub 2}, O{sub 2}, H{sub 2}O and any unreacted O{sub 3} gases are discharged into the vapor space. In addition to the non-radioactive metals in the waste, however, the SRS radioactive waste also contains a variety of radionuclides, hence, hydrogen gas is also present in the vapor space of the ECC system. Because hydrogen is flammable, the impact of this resultant gas stream on the Lower Flammability Limit (LFL) of hydrogen must be understood for all possible operating scenarios of both normal and off-normal situations, with particular emphasis at the elevated temperatures and pressures of the typical ECC operating conditions. Oxygen is a known accelerant in combustion reactions, but while there are data associated with the behavior of hydrogen/oxygen environments, recent, relevant studies addressing the effect of ozone on the flammability limit of hydrogen proved scarce. Further, discussions with industry experts verified the absence of data in this area and indicated that laboratory testing, specific to defined operating parameters, was needed to comprehensively address the issue. Testing was thus designed and commissioned to provide the data necessary to support safety related considerations for the ECC process. A test matrix was developed to envelope the bounding conditions considered credible during ECC processing. Each test consists of combining a gas stream of high purity hydrogen with a gas stream comprised of a specified mixture of ozone and oxygen in a temperature and pressure regulated chamber such that the relative compositions of the two streams are controlled. The gases are then stirred to obtain a homogeneous mixture and ignition attempted by applying 10J of energy to a fuse wire. A gas combination is considered flammable when a pressure rise of 7% of the initial absolute pressure is observed. The specified testing methodology is consistent with guidelines established in ASTM E-918-83 (2005) 'Standard Practices for Determining Limits of Flammability of Chemicals at Elevated Temperature and Pressure'. The LFL of hydrogen in air was determined and is in good agreement with the literature data. Ozone-oxygen mixtures were found to be flammable at concentrations above 8.3 vol.% based on the ASTM E918 7% pressure rise criteria for flame propagation. This result is lower than previously reported values which can be explained through the variations in the test setup and procedure. It is believed that the lower values obtained in this work are a result of improvements of the test methodology. Tests performed with hydrogen in various concentrations of ozone in oxygen have shown that the LFL of hydrogen decreases as the concentration of ozone in the mixture increases. This testing was designed to provide data under the conditions considered most optimal to produce deflagration. The geometry and materials of construction of the testing vessel; the location of the fuse wire; the magnitude of the supplied energy; the careful minimization of diluents and other contaminants; and meticulous procedural detail to maintain integrity of the ozone to the maximum extent practical, result in data that reflect not the expected process conditions, but those that enhance the possibility of flame propagation. For this reason, there is believed to be considerable conservatism in the indicated results. Per the vendor, the maximum possible ozone concentration producible by the planned ECC Ozone generator is 8 volume percent (the typical maximum operating setpoint concentration is 6.8 vol%), less than the 8.3 minimum volume % concentration shown to be flammable in a 99.999% pure O{sub 2} environment at the optimally conservative conditions established in this testing. Further, the feed to the ECC ozone generator is only 87% oxygen, the remainder, water vapor and nitrogen, both powerful diluents. It is, thus, believed not credible that deflagration can occur at this maximum feed concentration condition. In addition, once the ozone stream contacts the waste stream, the many simultaneous oxidizing reactions will rapidly decompose available ozone to well below flammable levels. Further, because the radiolytically generated hydrogen quantity is negligible compared to the supplied ozone/oxygen stream (0.0004 moles per minute H{sub 2} vs 76 moles per minute ozone/oxygen), even the total H{sub 2}/O{sub 3} mixture, without crediting decomposition reactions, does not approach flammable concentrations. Finally, even at the 'end' of the ECC batch cycle, when most of the metal oxalates have been decomposed, testing has indicated that the ozone concentration in the vapor space of the ECC process vessel reaches a concentration of no more than 3 vol%, remaining well below concentrations of concern. The major issue for the ECC operation established by this testing is the impact of the data when applied to off normal conditions. While it is possible to discontinue ozone addition to the reaction vessel at any time, the radiolytic hydrogen generation rate continues, varying slightly as ambient pressures and temperatures change. Relative to the data generated and analyzed in this testing, the ECC hazards analysis team will re-evaluate off normal conditions (e.g. those during which process exhaust ventilation is lost) such that issues involving mixtures of hydrogen and ozone in the vapor space can be appropriately controlled. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Liquid Secondary Waste Grout Formulation and Waste Form Qualification

This report describes the results from liquid secondary waste (LSW) grout formulation and waste form qualification tests performed at Pacific Northwest National Laboratory (PNNL) for Washington River Protection Solutions (WRPS) to evaluate new formulations for preparing a grout waste form with high-sulfate secondary waste simulants and the release of key constituents from these grout monoliths. Specific objectives of the LSW grout formulation and waste form qualification tests described in this report focused on five activities: 1.preparing new formulations for the LSW grout waste form with high-sulfate LSW simulants and solid characterization of the cured LSW grout waste form; 2.conducting the U.S. Environmental Protection Agency (EPA) Method 1313 leach test (EPA 2012) on the grout prepared with the new formulations, which solidify sulfate-rich Hanford Tank Waste Treatment and Immobilization Plant (WTP) off-gas condensate secondary waste simulant, using deionized water (DIW); 3.conducting the EPA Method 1315 leach tests (EPA 2013) on the grout monoliths made with the new dry blend formulations and three LSW simulants (242-A evaporator condensate, Environmental Restoration Disposal Facility (ERDF) leachate, and WTP off-gas condensate) using two leachants, DIW and simulated Hanford Integrated Disposal Facility (IDF) Site vadose zone pore water (VZPW); 4.estimating the 99 Tc desorption K d (distribution coefficient) values for 99 Tc transport in oxidizing conditions to support the IDF performance assessment (PA); 5.estimating the solubility of 99 Tc(IV)-bearing solid phases for 99 Tc transport in reducing conditions to support the IDF PA.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Core-Shell Oxidative Aromatization Catalysts for Single Step Liquefaction of Distributed Shale Gas (Final Technical Report)

The objective of this project was to design and demonstrate a core-shell structured multifunctional catalyst to convert the light (dry) components of shale gas into liquid aromatic compounds (primarily benzene and toluene) in a single step. Operated in a modular oxidative aromatization system (OAS) under a cyclic redox scheme, the novel catalyst and process can significantly improve the value and transportability of distributed shale gas. Since the project started, each quarter addressed a different set of tasks related to the completion of the milestone detailed in the project award. The yearly summaries of these tasks are summarized below: Q1-Q4: • Conducted project planning and literature search. • Investigated a number of SHC redox catalysts using thermogravimetric analysis and fixed-bed reactor experiments. • Initiated process modeling towards generating two process models for the methane DHA base case and OAS process. • Developed DHA catalysts capable of producing >500 g/kg-cat-hr aromatics at 80% or greater aromatics selectivity at 700°C. Q5-Q8: • Developed alternative approaches with sequential bed configurations to enhance the aromatic yields based on OCM+DHA • Improved the zeolite synthesis efficiency by using the microwave-assisted technique and investigated the synthesis conditions on the zeolite yield, crystalline structure and morphology • Constructed a set of Aspen Plus process models with significant energy savings for OAS as compared to the base case non-oxidative DHA. • Adapted conventional hydrothermal method to be applicable to the microwave synthesizer unit for more efficient catalyst synthesis. • Studied the structure of the OCM catalyst and the dispersion of the carbonate in the redox reactions and in methane flow with Raman Spectroscopy. Q9-Q12: • Scaled up the catalyst synthesis with the microwave synthesis method. Based on its performance, procedural characterizations and catalytic performance testing were further conducted for the new microwave synthesized catalysts with the newly-developed product analysis procedure. • Developed the reaction system setup for the C2-DHA or OCM+DHA reaction product and achieved a better product collection-analysis method for the aromatic products with an improved carbon balance. The product from the OCM reaction exhibited complicated effects on the DHA catalyst. • Conducted additional OCM catalyst characterization using Near Ambient Pressure X-ray Photoelectron Spectroscopy and in situ Raman characterization • Validated the significant energy savings for OAS as compared to the base case non-oxidative DHA. Successfully set up the simulation model for the OCM+DHA+SHC reaction system based on the updated experimental results from NCSU. Q13-End of project: • Synthesized new zeolite catalysts by the microwave method, conducted characterizations (XRD, SEM, and TEM) and catalytic behavior testing. • Explored the “wet” C 2 H 6 and C 2 H 4 DHA reactions with using steam co-feed. A subsequent reduction as the regeneration step can regenerate the DHA catalyst and recover 99% activity of the fresh performance. • Achieved a 15.3% single-pass aromatic yield from methane by rationally combining the OCM and DHA at different temperatures. • Conducted a 105-hour stability test with an improved regeneration procedure, with an average aromatic yield of 13.8%. • Developed new catalyst and achieved a record-high 23.2% yield.

03 NATURAL GAS↗

Super‐Droplet Method to Simulate Lagrangian Microphysics of Nuclear Fallout in a Homogeneous Cloud

Abstract Nuclear detonations produce hazardous local and global particles or fallout. Predicting fallout size, chemical components, and location is necessary to inform officials and determine immediate guidance for the public. However, existing nuclear detonation fallout models prescribe the particle size distributions based on limited observations. In this work, we apply the super‐droplet method, which is a numerical modeling technique developed for cloud microphysics, to simulate size distributions of particles in a mushroom cloud formed post‐detonation of a nuclear device. We model fallout formation and evolution with homogeneous nucleation and condensation of a single species and a Monte Carlo coagulation algorithm. We verify the numerical methods representing coagulation and condensation processes against analytical test problems. Additionally, we explore several scenarios for the integral system mass and yield in equivalent kilotons (kt) of TNT (trinitrotoluene). The fallout size distribution median diameter d pg follows a scaling law based on the integral system mass m v 0 kg and yield Y kt: nm. We test the effect of cloud turbulence, enhanced nucleation and growth, and vapor volatility with a sensitivity study. The range in median diameter predictions for simulations of historical tests performed over the Pacific encompass the measurements of particles sampled from the cloud caps. Predicted median particle size ranges up to 217, 123, 86, and 35 nm for historical tests with yields of 0.2, 0.7, 2, and 10 Mt, respectively. This work can be expanded in many different directions to build a more predictive model for fallout formation.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

BOPTest As a Platform for Building Controls and Grid-Interactive Buildings Workforce Training

Building automation and controls are becoming increasingly complex with the emergence of Grid Integrated Efficient Buildings (GEBs) as well as new highly efficient sequences of operation and data-driven control schemes. However, there remains a significant gap in hands-on training opportunities for building operators and technicians to gain practical experience with advanced control systems in a low-risk environment. This paper presents BOPTEST (Building Optimization Performance Test) as a suitable platform for workforce training in building controls and GEB technologies. BOPTEST provides a suite of standardized building simulation test cases with a REST API, real-time control interfaces through BACnet, semantic models connecting users to building data, and built-in calculation of control metrics and performance indicators. The platform enables trainees to interact with virtual buildings using industry-standard protocols while learning how to implement and innovate control strategies. The training platform is designed to offer a structured and interactive learning experience for building engineers, helping them effectively develop, learn, and retain skills in fault identification, troubleshooting, and correction. The workflow is divided into three main phases: 1) Setup, 2) Exercise, and 3) Review, each comprising specific activities performed by either the instructor or the student. Initial pilot training sessions have yielded positive feedback from instructors and participants and demonstrates that BOPTEST effectively fills an industry need for a low-risk training resource via simulation of real building control systems, allowing trainees to gain practical experience before working in the field. The platform's ability to provide immediate performance feedback while maintaining familiar industry interfaces makes it particularly suitable for workforce development programs. This work provides a replicable model for leveraging building simulation in control education and training.

Paul, Lazlo↗

BOPTEST as a Platform for Building Controls and Grid-Interactive Buildings Workforce Training

Building automation and controls are becoming increasingly complex with the emergence of Grid Integrated Efficient Buildings (GEBs) as well as new highly efficient sequences of operation and data-driven control schemes. However, there remains a significant gap in hands-on training opportunities for building operators and technicians to gain practical experience with advanced control systems in a low-risk environment. This paper presents BOPTEST (Building Optimization Performance Test) as a suitable platform for workforce training in building controls and GEB technologies. BOPTEST provides a suite of standardized building simulation test cases with a REST API, real-time control interfaces through BACnet, semantic models connecting users to building data, and built-in calculation of control metrics and performance indicators. The platform enables trainees to interact with virtual buildings using industry-standard protocols while learning how to implement and innovate control strategies. The training platform is designed to offer a structured and interactive learning experience for building engineers, helping them effectively develop, learn, and retain skills in fault identification, troubleshooting, and correction. The workflow is divided into three main phases: 1) Setup, 2) Exercise, and 3) Review, each comprising specific activities performed by either the instructor or the student. Initial pilot training sessions have yielded positive feedback from instructors and participants and demonstrates that BOPTEST effectively fills an industry need for a low-risk training resource via simulation of real building control systems, allowing trainees to gain practical experience before working in the field. The platform's ability to provide immediate performance feedback while maintaining familiar industry interfaces makes it particularly suitable for workforce development programs. This work provides a replicable model for leveraging building simulation in control education and training.

Paul, Lazlo↗

ENDF/B-VIII.0 Covariance Data Development and Testing for Advanced Reactors

This report documents the ENDF/B-VIII.0 covariance data development and testing performed at Oak Ridge National Laboratory performed under the auspices of the US Department of Energy Office of Nuclear Energy. This work supports modeling and simulation of advanced reactor designs in the US by analyzing, validating and improving the nuclear data that provide underlying physics for calculations. This report assesses nuclear data uncertainty information for neutron cross sections, provided in the form of covariance matrices, in the 2018 ENDF/B-VIII.0 library. A review and interpretation of some of the issues with the current covariance library is provided. A new approach to augment the ENDF/B-VIII.0 covariance matrix to accurately reflect uncertainties in the results of modeling and simulation reliant on the current nuclear data library is documented. Rigorous testing of the ENDF/B-VIII.0 covariance data is documented. Finally, the performance of the ENDF/B-VIII.0 covariance data for advanced reactor applications is assessed.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

OC6 project Phase III: validation of the aerodynamic loading on a wind turbine rotor undergoing large motion caused by a floating support structure

Abstract. This paper provides a summary of the work done within Phase III of the Offshore Code Comparison Collaboration, Continued, with Correlation and unCertainty (OC6) project, under the International Energy Agency Wind Technology Collaboration Programme Task 30. This phase focused on validating the aerodynamic loading on a wind turbine rotor undergoing large motion caused by a floating support structure. Numerical models of the Technical University of Denmark 10 MW reference wind turbine were validated using measurement data from a 1:75 scale test performed during the UNsteady Aerodynamics for FLOating Wind (UNAFLOW) project and a follow-on experimental campaign, both performed at the Politecnico di Milano wind tunnel. Validation of the models was performed by comparing the loads for steady (fixed platform) and unsteady (harmonic motion of the platform) wind conditions. For the unsteady wind conditions, the platform was forced to oscillate in the surge and pitch directions under several frequencies and amplitudes. These oscillations result in a wind variation that impacts the rotor loads (e.g., thrust and torque). For the conditions studied in these tests, the system aerodynamic response was almost steady. Only a small hysteresis in airfoil performance undergoing angle of attack variations in attached flow was observed. During the experiments, the rotor speed and blade pitch angle were held constant. However, in real wind turbine operating conditions, the surge and pitch variations would result in rotor speed variations and/or blade pitch actuations, depending on the wind turbine controller region that the system is operating. Additional simulations with these control parameters were conducted to verify the fidelity of different models. Participant results showed, in general, a good agreement with the experimental measurements and the need to account for dynamic inflow when there are changes in the flow conditions due to the rotor speed variations or blade pitch actuations in response to surge and pitch motion. Numerical models not accounting for dynamic inflow effects predicted rotor loads that were 9 % lower in amplitude during rotor speed variations and 18 % higher in amplitude during blade pitch actuations.

17 WIND ENERGY↗

RERTR-6 Irradiation Summary Report

The Reduced Enrichment for Research and Test Reactor (RERTR) experiment RERTR-6 was designed to evaluate several modified fuel designs that were proposed to address the possibility of breakaway swelling due to porosity within the (U. Mo) Al interaction product observed in the full-size plate tests performed in Russia and France. The following report summarizes the life of the RERTR-6 experiment through end of irradiation, including as-run neutronic analyses, thermal analyses and hydraulic testing results.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Silicon vertex tracker for RHIC PHENIX experiment

The PHENIX experiment at Relativistic Heavy Ion Collider will be equipped with Silicon Vertex tracker to enhance its physics capability. There are four layers of silicon sensor to reconstruct charged tracks with 50 {micro}m resolution of decay length measurement. The VTX surrounds the collision point. The inner two layers and the outer two layers are composed of 30 pixel ladders and 44 stripixel ladders, respectively. We have been developing these detectors and done a performance test with 120 GeV proton beam.

74 ATOMIC AND MOLECULAR PHYSICS↗

Developing and Implementing New Waste Chemistry Controls for Hanford's Double-Shell Tanks - 20041

Waste chemistry controls for the Hanford double-shell tanks (DSTs) were established in the 1980's in response to tank failures caused by stress corrosion cracking (SCC) at the Savannah River Site (SRS). The controls were established based on a combination of SRS chemistry limits and corrosion testing results. Conditions in the Hanford DSTs have changed over time, with the temperature in the majority of the DSTs dropping below 50 deg. C. Testing indicated that the original chemistry control specification and SCC testing performed in 2010 did not protect against pitting corrosion mechanisms - what is believed to have caused the failure of tank 241-AY-102. New waste chemistry controls are necessary to protect the DSTs from both SCC and pitting corrosion. Savannah River National Laboratory (SRNL), with input from the Tank Integrity Expert Panel (TIEP) Corrosion Subgroup (CSG), performed a statistically based investigation of nitrate and halide ion induced pitting corrosion. The investigation was intended to develop a comprehensive waste chemistry envelope that minimizes the risk of both SCC and pitting caused by halide and nitrate ions. The waste chemistry envelope needed to be robust enough to address future waste retrieval and process changes which could significantly change the waste composition of the DSTs. The experimental design allowed the statistically significant ions and their effect on pitting corrosion to be determined. SRNL developed the 'pitting factor' which is an empirical relationship between the statistically significant inhibitive species (hydroxide, and nitrite), and pitting inducing species (nitrate, chloride, and fluoride). The coefficients are weighted factors that show the degree of influence the species have on the propensity for pitting. New waste chemistry control limits were recommended by SRNL, and concurred with by the TIEP CSG, that incorporated the pitting factor along with other limits. The controls developed to reduce the risk of pitting corrosion were evaluated to determine if they also protected against SCC. Hundreds of test results were reviewed and compared against the proposed limits. With the exception of one test result, instances where cracking was observed corresponded to chemistry that was outside of the proposed limits - indicating that the chemistry controls developed for pitting also adequately addressed SCC concerns. Existing tank composition estimates were evaluated against the new chemistry controls - three current tank chemistries are suspect, and may not meet the new chemistry control requirements. These included the interstitial liquid (liquid associated with solids) of DSTs 241-AN-102, 241-AN-106, 241-AN-107, and 241-AY-101. Measures are ongoing to evaluate the tanks with the suspect chemistry. These include varying combinations of: performing additional evaluations (history of use, modeling); DST specific laboratory testing; and, pursuing core samples of the DSTs. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗