CSP Plant Optimization Study for the California Power Market (“CalCSP”) (Final Technical Report)

Concentrating Solar Power (CSP) with thermal energy storage offers a unique and strategic opportunity to support California’s clean energy transition. Unlike photovoltaic (PV) systems, CSP with thermal storage can generate electricity after sunset and during periods of high demand, making it a valuable complement to intermittent renewable resources. CSP also provides synchronous, inertia-contributing generation, long-duration storage, and flexible dispatch—capabilities increasingly important as thermal plants retire. This report summarizes the findings of the CSP Plant Optimization Study for the California Power Market or “CalCSP study,” which evaluated the technical, economic, environmental, and policy factors that influence the deployment of CSP technologies in California. The CalCSP study was conducted to assess how CSP can contribute to California’s long-term decarbonization goals while enhancing grid reliability, supporting local economic development, and making efficient use of land and transmission resources. It draws on detailed modeling of CSP performance and costs, site suitability analysis, policy reviews, and stakeholder engagement across utilities, regulators, developers, and community organizations. The analysis focuses on mature molten-salt tower technology and incorporates lessons learned from the global CSP fleet, distinguishing today’s CSP from earlier first-of-a-kind projects in the U.S. The findings support a more prominent role for CSP in California’s evolving clean energy landscape. With strategic planning, targeted policy support, and continued cost improvements, CSP can complement PV and batteries to deliver reliable, around-the-clock clean electricity—especially in areas with high solar resource and constrained grid capacity.

14 SOLAR ENERGY↗

A Secure and Adaptive Hierarchical Multi-Timescale Framework for Resilient Load Restoration Using a Community Microgrid

Distribution system integrated community microgrids (CMGs) can partake in restoring loads during extended duration outages. At such times, the CMGs are challenged with limited resource availability, absence of robust grid support, and heightened demand-supply uncertainty. Here, this paper proposes a secure and adaptive three-stage hierarchical multi-timescale framework for scheduling and real-time (RT) dispatch of CMGs with hybrid PV systems to address these challenges. The framework enables the CMG to dynamically expand its boundary to support the neighboring grid sections and is adaptive to the changing forecast error impacts. The first stage solves a stochastic extended duration scheduling (EDS) problem to obtain referral plans for optimal resource rationing. The intermediate near-real-time (NRT) scheduling stage updates the EDS schedule closer to the dispatch time using new obtained forecasts, followed by the RT dispatch stage. To make the decisions more secure and robust against forecast errors, a novel concept called delayed recourse is designed. The approach is evaluated via numerical simulations on a modified IEEE 123-bus system and validated using OpenDSS and hardware-in-loop simulations. The results show superior performance in maximizing load supply and continuous secure distribution network operation under different operating scenarios.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Search for direct CP violation in charged charmless B→PV decays

Measurements of C P asymmetry in charmless B → P V decays are presented, where P and V denote a pseudoscalar and a vector meson, respectively. Five different B → P V decays from four final states, B ± → π ± π + π - , B ± → K ± π + π - , B ± → K ± K + K - and B ± → π ± K + K - are analyzed. The measurements are based on a method that does not require full amplitude analyses, and are performed using proton-proton collision data at a center-of-mass energy of 13 TeV collected by LHCb between 2015 and 2018, corresponding to an integrated luminosity of 5.9 fb - 1 . In the π + π - P -wave, in the region dominated by the B ± → ρ ( 770 ) 0 K ± decay, a C P asymmetry of A C P = + 0.150 ± 0.019 ± 0.011 is measured, where the first uncertainty is statistical and the second is systematic. This is the first observation of C P violation in this process. For the other four decay channels, in regions dominated by the B ± → ρ ( 770 ) 0 π ± , B ± → K ( ¯ ) * ( 892 ) 0 π ± , B ± → K ( ¯ ) * ( 892 ) 0 K ± and B ± → Φ ( 1020 ) K ± decays, C P asymmetries in the P -wave compatible with zero are measured.

79 ASTRONOMY AND ASTROPHYSICS↗

BETTER Together

The Standard Energy Efficiency Data (SEED) and Building Efficiency Targeting Tool for Energy Retrofits (BETTER) platforms are both developed by the Department of Energy and work better together. SEED is a database to manage building characteristics and performance data from a variety of sources. BETTER provides simple energy efficiency measure analyses based on high level data about the building or portfolio of buildings. A demonstration of each platform and their integration will be provided. The inputs for BETTER are building type, floor area, location, utility data, and whether PV shall be included in the analysis. The BETTER analysis can be manually set up through the web application or data can be uploaded with a BuildingSync XML file either directly or through the API. SEED can be the source of this data and the data can be sent to BETTER through the SEED application after the BETTER API token has been entered. The benefit of utilizing SEED is that it has connections to many other sources of data such as ENERGY STAR Portfolio Manager, Audit Template, and Salesforce. Therefore, it is likely that a user of SEED will already have the required inputs for BETTER in SEED already and can create BETTER analyses across their whole portfolio in a couple mouse clicks. This is a major time savings and enables decision makers an easy path to identify buildings that should undergo more detailed audits or retrofit pathways.

ASHRAE↗

Machine learning with knowledge constraints for process optimization of open-air perovskite solar cell manufacturing

Perovskite photovoltaics (PV) have achieved rapid development in the past decade in terms of power conversion efficiency of small-area lab-scale devices; however, successful commercialization still requires further development of low-cost, scalable, and high-throughput manufacturing techniques. One of the critical challenges of developing a new fabrication technique is the high-dimensional parameter space for optimization, but machine learning (ML) can readily be used to accelerate perovskite PV scaling. Herein, we present an ML-guided framework of sequential learning for manufacturing process optimization. We apply our methodology to the Rapid Spray Plasma Processing (RSPP) technique for perovskite thin films in ambient conditions. With a limited experimental budget of screening 100 process conditions, we demonstrated an efficiency improvement to 18.5% as the best-in-our-lab device fabricated by RSPP, and we also experimentally found 10 unique process conditions to produce the top-performing devices of more than 17% efficiency, which is 5 times higher rate of success than the control experiments with pseudo-random Latin hypercube sampling. Our model is enabled by three innovations: (a) flexible knowledge transfer between experimental processes by incorporating data from prior experimental data as a probabilistic constraint; (b) incorporation of both subjective human observations and ML insights when selecting next experiments; (c) adaptive strategy of locating the region of interest using Bayesian optimization first, and then conducting local exploration for high-efficiency devices. Furthermore, in virtual benchmarking, our framework achieves faster improvements with limited experimental budgets than traditional design-of-experiments methods (e.g., one-variable-at-a-time sampling). This framework shows the capability of incorporating researchers’ domain knowledge into the ML-guided optimization loop; therefore, it has the potential to facilitate the wider adoption of ML in scaling to perovskite PV manufacturing.

14 SOLAR ENERGY↗

Comparative Analysis of Hotspot Stress Endurance in Pristine and Thermal Cycled Prestressed Glass–Glass Photovoltaic Modules

Hotspots pose a significant long-term reliability challenge in photovoltaic (PV) modules that can have a detrimental impact on the efficiency, safety, and financial viability of a PV system. This paper aims to evaluate the endurance of hotspot stress in pristine and prestressed glass–glass (GG) modules. The accelerated prestressing was conducted for 600 thermal cycles (TC600) to represent decades of field exposure. GG modules are quickly becoming an alternative to the traditional glass–backsheet (GB) modules that have been the industry standard. Unlike other conventional studies that subject only pristine modules to hotspot stress, this paper evaluates the performance of an accelerated/simulated field-aged GG module (using TC600) and a pristine GG module. Pre- and post-characterizations were performed before and after each test to determine changes in electrical performance and observe any defects in GG modules. During the hotspot test, an approximately 200 °C maximum cell temperature was observed with a cell shading of 25% (the worst-case shading ratio). After the hotspot test, electroluminescence imaging indicated that most cells in the prestressed GG module exhibited severe damage whereas no significant defects were evident in the pristine GG module where the prestressed GG module degraded 8.2% and the pristine GG module degraded 1.5% in maximum power. These findings are critical for the industry, considering that GG bifacial modules will dominate the market.

14 SOLAR ENERGY↗

Drivers for the cracking of multilayer polyamide‐based backsheets in field photovoltaic modules: In‐depth degradation mapping analysis

Abstract There is a lack of understanding on the root cause of cracking of photovoltaic (PV) backsheets due to the challenge of multilayer characterization and the complicated failure modes at the submodule level. In this work, the in‐depth degradation mapping of field‐exposed polyamide‐based (PA‐based) PV module backsheets was studied, with the major focus on the identification of underlying drivers for the through cracking (in between the solar cells). PV modules were retrieved from five different locations, comprising a variety of climates, including humid subtropical, hot‐summer Mediterranean, tropical savanna climate, and hot arid. A suite of microscale cross‐sectional characterizations, including chemical changes, fluorescence intensity, and modulus as a function of distance from the air surface of the backsheet, was performed. Results showed more advanced signs of degradation of the inner layer than the outer layer in the cracking region. Increases in the modulus were identified as the major indicator for the cracking. Moreover, a rudimentary test by immersion in acetic acid, which forms during photodegradation of the ethylene‐vinyl acetate copolymer (EVA) encapsulant, showed the first‐time direct evidence that acetic acid can largely accelerate the chemical degradation and facilitate the cracking of PA inner layer. This study suggests that the field cracking of PA‐based backsheet can be attributed to the combined effects of chemical degradation and physical reorganization (chemi‐crystallization) under cyclic thermomechanical stresses. Therefore, it is important to consider effects of local microclimates and interlayer infection to understand the heterogeneous nature of backsheet failures.

Lyu, Yadong↗

Grid-Connected Modular Soft-Switching Solid State Transformers (M-S4T)

The objective of this project is to develop and verify the concept of a flexible and modular soft-switching solid-state transformer (M-S4T) for direct grid-connected applications. The ability to directly connect power electronics converters to the medium voltage grid (4 kV – 13 kV), and to potentially replace the passive and bulky, but ubiquitous 60 hertz service transformer in the 25 kVA to 100 kVA range, with a more flexible and controllable device, has been regarded as the ‘holy grail’ in grid control. However, this has proven to be extremely difficult. This project has developed the solutions to several key challenges of the direct grid-connected power electronics and realized a 7.2 kV M-S4T prototype. First, a protection method to protect the M-S4T from the high voltages (110 kV for the 13 kV system) that occur on the grid due to transients and lightning strikes have been developed and experimentally verified. Second, the realization and the operation of the M-S4T based on high-voltage SiC devices (>3.3 kV) and a medium-frequency medium-voltage low-leakage transformer in a single-stage solid-state transformer with zero-voltage switching, low dv/dt, and low electromagnetic interference has been successfully demonstrated up to 7.5 kV peak. Third, an oil-cooling system and stable communication and distributed control system for converter module voltage sharing have been developed and experimentally verified. The developed M-S4T has realized a modular universal high-performance power conversion system. This conversion system is scalable to different voltage and power levels and adaptable to four-quadrant bidirectional operation. Moreover, the use of passive cooling techniques meets the equipment life requirements, and the lightning protection scheme fulfills the basic insulation level specifications for direct grid connection. Such power conversion system opens up near-term opportunities, including energy storage, solar PV, or electric vehicle charging with significant cost and footprint savings. In the longer term, the possibility of replacing the utility distribution transformer with an M-S4T will be transformative for future distribution grids with a compact footprint and full controllability to enable high renewable energy and storage penetration. In addition to the main project, this report expands on the Plus-Up projected including as part of the main award. This project developed and demonstrated the technology for autonomous collaborative inverters that can be connected in an ad hoc manner to the grid. The aim of the project was to: (1) evaluate the existing techniques for grid-connected inverters and find their limitations; (2) develop detailed requirements for grid-connected inverters in the modern grid with millions of active nodes; (3) design a unified control strategy that brings more autonomy and intelligence to grid-connected inverters, and addresses parts of the issues with the existing techniques. The proposed technique, called UniCon, enables inverters to 1) connect/disconnect to/from the grid in an ad hoc manner; (2) work based on local sensing. Slow communication could be used for a more optimized behavior; (3) work automatically in both grid-forming/grid-following mode; (4) handle large disturbances, e.g., big load step and fault, in an oscillation-free manner; (5) work collaboratively with other inverters in steady-state and during transients. UniCon can be implemented in the middle-level control; hence it is agnostic to the vendor and to the implementation of the inner voltage/current and protection loops. Furthermore, a new synchronization scheme, based on deep learning, was developed that can extract the grid voltage phase and amplitude in a stable manner. The method is cheap to implement can improve the dynamic performance of the grid-connected inverters during fast transients, e.g., fault. The proposed control scheme was validated by (1) MATLAB/Simulink; (2) hardware-in-the-loop results, and; (3) experimental results using three inverters that form a microgrid in a down-scaled feeder. Lastly, both the M-S4T and UniCon have achieved promising tangible paths to markets. In the case of the M-S4T, the underlying technology — the Soft Switching Solid State Transformer (S4T) developed at the Georgia Tech Center for Distributed Energy (GT-CDE) has been licensed by GridBlock from the Georgia Tech Research Corporation, and GridBlock has been working with manufacturing partner Jabil (one of the largest US-based contract manufacturers) and system integrator Power Secure (largest deployer of microgrids in the US with 4.7 GW under management), to meet the strong initial demand. Similarly, GridBlock has an exclusive license to the UniCon technology, developed under this award by GT-CDE. The UniCon provides an intermediate control layer that enables the implementation of the higher-level ‘transactive’ control commands for the system. The architecture of the system - slow communications with the cloud for system optimization and setpoints, and the use of locally measured quantities for real-time control, provide a very robust and secure way of implementing a real-time must-run grid that is also secure and stable. This is a brand-new functionality that is critical for the future grid and key to GridBlock’s business model.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Optimal planning of the joint placement of photovoltaic panels and green roofs under climate change uncertainty

Photovoltaic (PV) panels directly convert sunlight into electricity; but, sunlight also heats the panels, negatively impacting their efficiency. Green roofs are vegetative layers grown on rooftops, mainly to provide added insulation on the roof to save energy. Green roofs also cool near-surface air temperature. Hence, the joint installation of PV panels and green roofs may potentially lead to higher efficiency of PV panels in certain climates. We develop a two-stage stochastic programming model to optimally place PV panels and green roofs under climate change uncertainty to maximize the overall profit from energy generated and saved. We calibrate the model using the literature, industry reports, and the data from different, at times conflicting, climate projections. We then conduct a case study for a mid-size city in the U.S., perform extensive sensitivity and robustness analyses and provide insights.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Thermodynamics of Light Management in Near-Field Thermophotovoltaics

We evaluate near-field thermophotovoltaic (TPV) energy-conversion systems focusing in particular on their open-circuit voltage (V OC ). Unlike previous analyses based largely on numerical simulations with fluctuational electrodynamics, here, we develop an analytic model that captures the physics of near-field TPV systems and can predict their performance metrics. Using our model, we identify two opportunities of TPV systems operating in the near field. First, we show analytically that enhancement of radiative recombination is a natural consequence of operating in the near field. Second, we note that, owing to photon recycling and minimal radiation leakage in near-field operation, the PV cell used in near-field TPV systems can be much thinner compared to those used in solar PV systems. Since nonradiative recombination is a volumetric effect, use of a thinner cell reduces nonradiative losses per unit area. The combination of these two opportunities leads to increasingly large values of V OC as the TPV vacuum gap decreases. Hence, although operation in the near-field was previously perceived to be beneficial for electrical power-density enhancement, here, we emphasize that thin-film near-field TPVs are also significantly advantageous in terms of V OC and consequently conversion efficiency as well as power density. We provide numerical results for an InAs-based thin-film TPV that exhibits efficiency >50% at an emitter temperature as low as 1100 K.

42 ENGINEERING↗

A Nonlinear Direct Power Controller for a Three-Phase Grid-Connected Inverter with Online Parameter Update for PV Application

This work proposes a nonlinear direct power controller for a three-phase grid-connected inverter for photovoltaic application. Grid-connected converters for solar applications require advanced control architectures to ensure optimal operation and extraction of maximum power from the photovoltaic arrays. Therefore, to ensure this, a nonlinear power controller architecture has been proposed to extract the maximum power from the solar arrays and to achieve the most optimal operation. To further improve the performance, a parameter update scheme has been utilized which is based on model reference adaptive system. The latter helps to accomplish not only good dynamic response but also excellent tracking performance. The overall control come estimation architecture is verified based on computer simulations via MATLAB/Simulink and PLECS domain and various important case study results are presented.

direct power control↗

Impact of acetic acid exposure on metal contact degradation of different crystalline silicon solar cell technologies

Degradation due to acetic acid in photovoltaic (PV) modules has been a commonly observed phenomenon for both damp-heat exposure and outdoor operations. Acetic acid is a degradation byproduct of ethylene-vinyl acetate (EVA), a common module encapsulant. To address this issue, robust metallization pastes and cell technologies are being developed. However, it is important to assess how these technologies perform in an acetic acid environment and withstand degradation before they are implemented in the solar market. In this work, we investigate the impact of acetic acid exposure on four different cell groups: monofacial passivated emitter and rear contact (PERC) cells with advanced telluride-based front contact pastes, bifacial PERC cells with novel aluminum rear contact pastes, bifacial tunnel oxide passivated contacts (TOPCon) cells, and silicon heterojunction (SHJ) cells. These cells were exposed to acetic acid for different time increments. The recombination losses were characterized by Suns-VOC, and multi-variate regression analysis of intensity-dependent photoluminescence (PL) images with Griddler AI. Resistive losses were tracked with the transmission line method (TLM). Samples showing severe performance degradation were selected for further materials characterization to understand the root cause. Top-down and cross-sectional scanning electron microscopy (SEM), energy dispersive spectroscopy (EDS), and X-ray photoelectron spectroscopy (XPS) were performed to investigate the change in materials properties. Our study shows that the front contacts of the bifacial TOPCon cells and monofacial PERC cells were significantly affected by acetic acid exposure. Here, the SHJ cells were found to be the most stable.

14 SOLAR ENERGY↗

reV (The Renewable Energy Potential Model - Open Source) [SWR-21-59, SWR-20-20 and SWR-17-34]

The Renewable Energy Potential (reV) model is a platform for the detailed assessment of renewable energy resources and their geospatial intersection with grid infrastructure and land use characteristics. The reV model currently supports photovoltaic (PV), concentrating solar power (CSP), and land-based wind turbine technologies. Modules in the reV framework function at different spatial and temporal resolutions, allowing for the assessment of resource potential, technical potential, and supply curves at varying levels of detail. The platform runs on the National Renewable Energy Laboratory’s (NREL’s) high-performance computing system, providing scalable and efficient performance from a single location up to a continent, for a single year or decades of time-series resource data. Coupled with NREL’s System Advisor Model (SAM), reV supports resource assessments from 5-minute to hourly temporal resolutions and supports the analysis of long-term (i.e., year-on-year) variability of renewable generation (e.g., interannual variability and exceedance probabilities).

Maclaurin, Galen↗

Solar Thermal Energy Planner (STEP 1): A New Decision Support Tool for Solar Industrial Process Heat Applications

Solar thermal technologies are a promising technology to supply low-cost thermal energy to industrial processes, but there are often significant barriers to entry to industrial owners considering these technologies for their energy demands. To overcome this barrier and convey economic value to customers, NREL and Sandia National Laboratories developed Solar Thermal Energy Planner (STEP 1), a new web-based decision support tool for solar industrial process heat systems. At SolarPACES 2024, the STEP 1 tool was still under development; progress, methodologies, and a preliminary case study was presented. With the STEP 1 tool launch in May 2025, in this work, the initial version of the full public tool will be presented with demonstrations of its capabilities using a few case studies. First, the user's process heat needs such as location, process media (e.g., steam, air), process temperature, land availability, electricity and fuel costs, among other parameters. STEP 1 features a mapping interface that allows users to draw land and roof boundaries. The process media and temperature inform technology selection criteria modules that determine the appropriate solar thermal collection technologies, as well as congruent heat transfer media (e.g., hot water, oil, salt). Once the solar thermal technology selected, its nominal thermal production for the given site is characterized using NREL's System Advisor Model (SAM). Then, a modified version of NREL's REopt optimal sizing and dispatch optimization tool determines cost-optimal sizing. Within minutes, the user receives the results of the technoeconomics analysis, including the size and performance of the cost-optimal solar-plus-storage system. The cost of the system is compared to business-as-usual (e.g., an existing, standalone natural gas boiler). Users can download key results to store for sensitivity analyses. Examples of flat plate collector, parabolic trough, and molten salt tower applications with and without PV hybridization for different industrial facility types are presented in this work. The STEP 1 tool aims to reduce barriers to the adoption of solar heating solutions stemming from a lack of familiarity and technical background with solar system design options and costs among industry stakeholders.

14 SOLAR ENERGY↗

The Interactions Between Shading and Organic Fertilizer Application on Dry-farmed Tomato Grown Between Photovoltaic Panels

Agrivoltaic systems are mixed systems of solar photovoltaic (PV) panels and agricultural production, where shade from the panels can result in lower evapotranspiration for crops, which is of particular interest for dryland agriculture. Dry-farmed tomato (Solanum lycopersicum) production in the Willamette Valley of Oregon has lower total yields and higher rates of blossom-end rot (BER) than irrigated tomato production, resulting in reduced marketable yields. To determine how dry-farmed ‘Early Girl’ tomato performed in an agrivoltaics system, a trial was conducted at the Valley Creek Solar Project (Salem, OR, USA) in 2020, using three different amendment treatments and three levels of shading from the panels. Amendment treatments were 0N (receiving no fertilizer), 84N (receiving 84 kg·ha −1 N), and 168N (receiving 168 kg·ha −1 N), applied as processed chicken manure. Plants were estimated to receive an irradiance factor of 30%, 76%, and 89% for full-shade, partial-shade, and full-sun treatments respectively. There was an interaction between amendment treatments and shading treatments in their effects on unblemished yield (yield of fruit without BER or sunscald). The optimum fertilizer application for full-shade and partial-shade rows was 84N, the optimum for full-sun rows was 0N. Fertilizing these rows at these rates resulted in an unblemished yield for the aisle of 11.1 t·ha −1 , which was lower than unblemished yields reported in previous experiments and trials in open fields. However, these results are from a single location and a single year, and other solar sites may behave more similar to open-field conditions. Shading from the panels increased average fruit weight and decreased incidence of BER and sunscald, suggesting that crops were less drought stressed. This resulted in similar unblemished yields for the full-shade and full-sun plots at 84N and 168N. Applying fertilizer resulted in higher total yields, smaller average fruit weight, increased BER incidence, and decreased sunscald incidence. The results suggest a possible synergy between dry-farmed tomato production and agrivoltaics, although several concerns remain, including difficulties managing the vegetation under panels, rules restricting PVs on high-value agricultural soils, and the possibility of soil compaction during PV installation.

14 SOLAR ENERGY↗

Initial Feasibility Assessment of Agrivoltaics in Jackson County, IL

Consistent with concerns raised in other rural communities, the agricultural community in Jackson County, IL is reluctant to install ground based photovoltaic (PV) systems on prime agricultural land. Agrivoltaic solutions have the potential to mitigate community concerns of conversion of farmland to solar energy by allowing for both energy production and farming practices to occur on the same land area. To assess the potential for agrivoltaics in Jackson County, IL, the Jackson County Coalition requested technical assistance to perform an initial technoeconomic assessment, resource assessment, and feasibility assessment based on the unique agricultural context present in the area. In this paper, the National Renewable Energy Laboratory (NREL) interviewed five Jackson County experts for five key crops (vineyards, strawberries, pumpkins, apple and pear orchards, and hemp) to examine potential for agrivoltaics integration and identify key barriers that could hamper development. NREL performed technoeconomic analysis for different agrivoltaic system designs to determine the economic constraints and opportunities of agrivoltaics development. Overall, there is no one path for agrivoltaics success in Jackson County. Pilot projects can assist in demonstrating agrivoltaic feasibility to stakeholders reluctant to be first adopters. Based on preliminary analyses, agrivoltaic integration with vineyards may prove most feasible as the per acre returns of grapes are comparable with the returns needed to offset higher solar development costs for agrivoltaic systems. In terms of technical specifications of solar, pumpkins and strawberries could be integrated into more traditional solar designs, but there are concerns with shading and pest control. There is no one size fits all solution, and many options may need exploring before a workable solution is found.

14 SOLAR ENERGY↗

Feed-Forward Compensation for Model Predictive Control in Tri-port Current-Source Medium-Voltage String Inverters for PV-Plus-Storage Farms

The novel tri-port current-source medium-voltage string inverter (TCS-MVSI) is a promising candidate for large-scale PV-plus-storage (PVS) farms owing to its galvanic isolation, easy storage integration, soft-switching capability across entire load range, controlled low dv/dt and EMI, benign fault tolerance, etc. Due to its low inertia feature, traditional PI-based control cannot manage large transients effectively. Instead, a model-based predictive control (MPC) is proposed to achieve robust and stable operation. As is well known, the control performance of MPC is compromised by the sampling and computational delay during implementation significantly, if not well addressed. This paper analyzed and quantified these delays and then proposes feed-forward compensation (FFC) for the MPC method to compensate the delays and the large parameter variations due to the low-inertia nature. In addition, this method also compensates for the high dc-link ripple within each switching cycle, a unique issue for low-inertia converters. Here, the proposed method requires low computational effort, allowing it to be extended for multiple ports. The effectiveness of the proposed method has been validated in experiments. In 10 kW test, the proposed method decreases the average dc-link current by 17%, leading to ~20% conduction losses and ~0.5% increase in converter efficiency. In addition, the peak dc-link current also decreases by 15%, resulting in reduced transformer size. As a result, an increased power density can be achieved with the proposed method. Similar improvements have been observed across the power range from 2 kW to 10 kW.

30 DIRECT ENERGY CONVERSION↗

Ensemble voting-based fault classification and location identification for a distribution system with microgrids using smart meter measurements

This study presents an ensemble learning approach for fault classification and location identification in a smart distribution network containing photovoltaics (PV)-based microgrid. Lack of available data points and the unbalanced nature of the distribution system make fault handling a challenging task for utilities. The proposed method uses event-driven voltage data from smart meters to classify and locate faults. The ensemble voting classifier is composed of three base learners; random forest, k-nearest neighbours, and artificial neural network. The fault location (FL) task has been formulated as a classification problem where the fault type is classified in the first step and based on the fault type, the faulty bus is identified. The method is tested on IEEE-123 bus system modified with added PV-based microgrid along with dynamic loading conditions and varying fault resistances from 0 to 20 Ω for both unbalanced and balanced fault types. A further sensitivity analysis has been done to test the robustness of the proposed method under various noise levels and data loss errors in the smart meter measurements. The ensemble method shows improved performance and robustness compared to some previously proposed FL methods. Finally, the proposed method has been experimentally validated on a real-time simulation-based testbed using a state-of-the-art digital real-time simulator, industry standard DNP3 communication protocol and a cpu-based control centre running the FL algorithm.