Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PV installation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 793 records · Page 44

Summary Paper: An Initial Heliostat Supply Chain Analysis

This paper summarizes the prior analysis, key findings, and recommendations from the published report titled “Initial Heliostat Supply Chain Analysis” [1]. Globally, the growing demand for concentrating solar power (CSP) technologies, primarily for electricity generation plants has been met with supply chains primarily composed of plentiful commodity materials such as steel, aluminum, and glass. Often the commodity materials can be sourced in the domestic market where power plant will be constructed. Although specialty components are required for CSP solar fields —including mirror panels used for heliostat applications—these specialty components constitute about 30-50% of total system installed costs [2]. Only a few companies and countries, including the United States, have developed the capacity to supply such specialty components. The U.S. heliostat supply chain at present is comprised of few companies (e.g., CSP developers), component suppliers, and is its infancy. By 2035, with current and aggressive solar photovoltaic (PV) capacity expansions, there is the potential for 500,000–1,500,000 direct and indirect jobs in the areas of manufacturing, installation and development, and operations and maintenance (O&M) [3]. Utilizing the CSP capacity estimations the recent NREL report [4], the construction of 39 gigawatts (GW) of CSP (assuming mainly power tower) in the U.S. could lead to approximately 195,000 manufacturing, construction, and O&M jobs. This does not include the longer-term jobs and economic impact (e.g., taxes from plant operations staff) from operating the plants once constructed. It is recommended that further CSP component and system supply chain analysis and modelling be undertaken.

Kurup, Parthiv (ORCID:0000000217356703)↗

Low-Cost High-Concentration Photovoltaic Systems for Utility Power Generation

Under DOE's Technology Pathway Partnership (TPP) program, Amonix, Inc. developed a new generation of high-concentration photovoltaic systems using multijunction technology and established the manufacturing capacity needed to supply multi-megawatt power plants built using the new Amonix 7700-series solar energy systems. For this effort, Amonix Collaborated with a variety of suppliers and partners to complete project tasks. Subcontractors included: Evonik/Cyro; Hitek; the National Renewable Energy Laboratory (NREL); Raytech; Spectrolab; UL; University of Nevada, Las Vegas; and TUV Rheinland PTL. The Amonix TPP tasks included: Task 1: Multijunction Cell Optimization for Field Operation, Task 2: Fresnel Lens R&D, Task 3: Cell Package Design & Production, Task 4: Standards Compliance and Reliability Testing, Task 5: Receiver Plate Production, Task 6: MegaModule Performance, Task 7: MegaModule Cost Reduction, Task 8: Factory Setup and MegaModule Production, Task 9: Tracker and Tracking Controller, Task 10: Installation and Balance of System (BOS), Task 11: Field Testing, and Task 12: Solar Advisor Modeling and Market Analysis. Amonix's TPP addressed nearly the complete PV value chain from epitaxial layer design and wafer processing through system design, manufacturing, deployment and O&M. Amonix has made progress toward achieving these reduced costs through the development of its 28%+ efficient MegaModule, reduced manufacturing and installation cost through design for manufacturing and assembly, automated manufacturing processes, and reduced O&M costs. Program highlights include: (1) Optimized multijunction cell and cell package design to improve performance by > 10%; (2) Updated lens design provided 7% increased performance and higher concentration; (3) 28.7% DC STC MegaModule efficiency achieved in Phase II exceeded Phase III performance goal; (4) New 16' focal length MegaModule achieved target materials and manufacturing cost reduction; (5) Designed and placed into production 25 MW/yr manufacturing capacity for complete MegaModules, including cell packages, receiver plates, and structures with lenses; (6) Designed and deployed Amonix 7700 series systems rated at 63 kW PTC ac and higher. Based on an LCOE assessment using NREL's Solar Advisor Model, Amonix met DOE's LCOE targets: Amonix 2011 LCOE 12.8 cents/kWh (2010 DOE goal 10-15); 2015 LCOE 6.4 cents/kWh (2015 goal 5-7) Amonix and TPP participants would like to thank the U.S. Department of Energy Solar Energy Technology Program for funding received under this program through Agreement No. DE-FC36-07GO17042.

14 SOLAR ENERGY↗

Analysis of Reactive Power Load Modeling Techniques for PV Impact Studies [Slides]

The increasing availability of advanced metering infrastructure (AMI) data has led to significant improvements in load modeling accuracy. However, since many AMI devices were installed to facilitate billing practices, few utilities record or store reactive power demand measurements from their AMI. When reactive power measurements are unavailable, simplifying assumptions are often applied for load modeling purposes, such as applying constant power factors to the loads. The objective of this work is to quantify the impact that reactive power load modeling practices can have on distribution system analysis, with a particular focus on evaluating the behaviors of distributed photovoltaic (PV) systems with advanced inverter capabilities. Quasi-static time-series simulations were conducted after applying a variety of reactive power load modeling approaches, and the results were compared to a baseline scenario in which real and reactive power measurements were available at all customer locations on the circuit. Overall, it was observed that applying constant power factors to loads can lead to significant errors when evaluating customer voltage profiles, but that performing per-phase time-series reactive power allocation can be utilized to reduce these errors by about 6x, on average, resulting in more accurate evaluations of advanced inverter functions.

14 SOLAR ENERGY↗

TEAMER: MADWEC Techno-Economic Analysis

The objective of this project was for the facility to conduct a techno-economic assessment (TEA) of the Maximal Asymmetric Drag Wave Energy Converter (MADWEC), developed by the University of Massachusetts Dartmouth (UMass Dartmouth). MADWEC is used for powering remote monitoring and Autonomous Underwater Vehicle (AUV) charging systems compared to other existing power supply options. The assessment estimates capital expenditures (CapEx), operational expenditures (OpEx), and power performance for 18 scenarios with the purpose of identifying key cost drivers, comparing total system cost, and comparing the power performance of the power supply options in terms of required installed capacity and estimated theoretical annual energy performance. The 18 assessed scenarios include two end-uses: 1) AUV charging and 2) offshore remote monitoring); three power sources: 1) MADWEC), 2) photovoltaic (PV) solar buoy, 3) and traditional battery swapping); and three locations; 1) nearshore, 2) far-offshore, and 3) high-latitude). In addition, other project goals included developing high level installation, operation, and maintenance plans for each scenario. The techno-economic model, created in Microsoft Excel, estimates CapEx, OpEx, and the power performance of each power supply source. The model has a dynamic format that allows custom inputs to accommodate future changes to the systems being assessed. This is a TEA for the MADWEC project, TEAMER RFTS 7 (request for technical support) program.

16 TIDAL AND WAVE POWER↗

Tracking the Sun: Pricing and Design Trends for Distributed Photovoltaic Systems in the United States, 2024 Edition [Slides]

Berkeley Lab’s annual Tracking the Sun report describes trends among grid-connected, distributed solar photovoltaic (PV) and paired PV+storage systems in the United States. For the purpose of this report, distributed solar includes residential systems, roof-mounted non-residential systems, and ground-mounted systems up to 5 MW-AC. Ground-mounted systems larger than 5 MW-AC are covered in Berkeley Lab’s companion annual report, Utility-Scale Solar. The latest edition of the report is based on 3.7 million systems installed through year-end 2023, representing close to 80% of systems installed to date. The report describes and discusses key trends related to: -Project characteristics, including system size, module efficiencies, roof-coverage ratios, prevalence of paired PV with storage, use of module-level power electronics, third-party ownership, mounting configurations, panel orientation, and customer segmentation -Median installed-price trends, both nationally and by state -Variability in pricing according to system size, state, installer, equipment type, and other factors, relying on both descriptive analysis and a multi-variate regression to estimate the effects of key pricing drivers for residential systems installed in 2023.

14 SOLAR ENERGY↗

Q2/Q3 2017 Solar Industry Update

This technical presentation provides an update on the major trends that occurred in the solar industry in Q2 and Q3 of 2017. Major topics of focus include global and U.S. supply and demand, module and system price, investment trends and business models, and updates on U.S. government programs supporting the solar industry.

14 SOLAR ENERGY↗

Q3/Q4 2017 Solar Industry Update

This technical presentation provides an update on the major trends that occurred in the solar industry in the Q3 and Q4 of 2017. Major topics of focus include global and U.S. supply and demand, module and system price, investment trends and business models, and updates on U.S. government programs supporting the solar industry.

14 SOLAR ENERGY↗

Q4 2017/Q1 2018 Solar Industry Update

This technical presentation provides an update on the major trends that occurred in the solar industry in Q4 2017 and Q1 2018. Major topics of focus include global and U.S. supply and demand, module and system price, investment trends and business models, and updates on U.S. government programs supporting the solar industry.

14 SOLAR ENERGY↗

Q1/Q2 2018 Solar Industry Update

Each quarter, the National Renewable Energy Laboratory (NREL) conducts a presentation of technical trends within the solar industry, which became publicly available in October 2016. Each presentation focuses on global and U.S. supply and demand, module and system price, investment trends and business models, and updates on U.S. government programs supporting the solar industry.

14 SOLAR ENERGY↗

Q2/Q3 2018 Solar Industry Update

Each quarter, the National Renewable Energy Laboratory (NREL) conducts a presentation of technical trends within the solar industry, which became publicly available in October 2016. Each presentation focuses on global and U.S. supply and demand, module and system price, investment trends and business models, and updates on U.S. government programs supporting the solar industry.

14 SOLAR ENERGY↗

Manifold Integrated Pyrovalve

The Manifold Integrated Pyrovalve (MI-PV) provides a state-of-the-art, low mass, low volume, normally-closed (NC) pyrotechnic isolation valve configuration which is optimized for small free-flier applications. Small scale free-flier (e.g. CubeSat) applications require high pressure fluid isolation valves with leak rates low enough to endure long pad stays, and often have severe mass and volume limitations. The MI-PV utilizes a unique configuration where the shear section and the pyrotechnic ram assembly (PRA) are installed directly into a ported gas manifold, allowing elimination of heavy fluid fittings and connections. This configuration can be readily scaled and adapted to the needs of other long duration missions.

valve pyrovalve pyrotechnic↗

Impact of soiling on Si and CdTe PV modules: Case study in different Brazil climate zones

Soiling, particulate accumulation on photovoltaic (PV) module surfaces, reduces the available solar resource and the resulting generated device power. This case-study summarizes initial results of 5-year research on the contrasting soiling conditions in the tropical, subtropical, and semi-arid climates in Brazil. A major objective is to present a case study of the effects of soiling on PV module performance in different Brazil climate zones that represent the primary areas for the current and expanding Brazil solar installations. For this, the paper presents methodologies to quantify the soiling ratio (SRatio) and soiling rate (SRate) for two representative commercial technologies, polycrystalline or multicrystalline silicon (mc-Si) and thin-film cadmium telluride (CdTe) modules, through soiling monitoring stations deployed in the selected climate regions. An aim is to add to the growing soiling-research knowledge base through addressing these key factors and their relationships to critical electrical, solar resource, thermal, and local meteorological and environmental parameters. This paper presents, evaluates, and compares soiling rates and losses in Belo Horizonte, Minas Gerais (Equatorial Tropical: 19.92° S, 43.99° W), Porto Alegre, Rio Grande do Sul (Humid-Subtropical: 30.05° S, 51.17° W), and Brotas de Macaúbas, Bahia (Semi-Arid: 12.00° S, 42.63° W). The results show that soiling is moderate in all 3-regions, for example with 0.1%/day < SRate < 0.2%/day for Belo Horizonte. Precipitation dominates the cleaning of the modules in the summertime in this climate zone, while it is the major factor year-round in Rio Grande do Sul. Wind is the major issue mitigating the soiling accumulation for the Bahia installation. The methodology incorporates several key refinements, including the normalization and adjustment for the meteorological parameters (temperature, irradiance, wind, precipitation). The evaluations include the region-specific differing effects of non-uniform soiling, natural cleaning, and ambient temperatures.

14 SOLAR ENERGY↗

Masking of photovoltaic system performance problems by inverter clipping and other design and operational practices

We describe how performance problems can be “masked,” or not readily evident by several causes: by photovoltaic (PV) system configuration (such as the size of the PV array capacity relative to the size of the inverter and the resultant clipped operating mode); by instrumentation design, installation, and maintenance (such as a misaligned or dirty pyranometer); by contract clauses (when operational availability is transformed to contractual availability, which excludes many factors); and by identified management and operational practices (such as reporting on a portfolio of plants rather than individually). A simple method based on a duration curve is introduced to overcome shortcomings of Performance Ratio based on nameplate capacity and Performance Index based on hourly simulation when quantifying masking effects, and inverter clipping and pyranometer soiling are presented as two examples of the new method. With a better understanding of the non-transparency of masking issues, stakeholders can better interpret performance data and deliver improved AC and DC plant conditions through PV system operation and maintenance (O&M) for improved performance, reduced O&M costs, and a more consistently delivered, and reduced, levelized cost of energy (LCOE).

14 SOLAR ENERGY↗

Greenbuilt Construction Energy Efficiency Retrofit House Demonstration - Sacramento

One of the homes that was part of Sacramento Municipal Utility District's (SMUD) Energy Efficiency Retrofit Demonstration (EERD) project was a 1980's era home in Fair Oaks, California, referred to as the Greenbuilt house, as Greenbuilt Construction completed the retrofit of the home. The home underwent an extensive energy efficiency retrofit with a goal of achieving a 50% reduction in energy use to demonstrate the potential for other builders and homeowners in the area. The retrofit measures included installing: ENERGY STAR appliances high efficiency light roof radiant barrier additional ceiling and wall insulation double-pane, low-e windows external motorized shading and solar tubes a 16 SEER/9.75 HSPF heat pump improved ducts a whole-house fan a heat pump water heater (HPWH) integrated collector storage solar water heater (ICS SWH) and 3.2 kW of PV. In addition, the home was air sealed to reduce infiltration. Researchers from the National Renewable Energy Laboratory (NREL) performed short-term tests on the major systems installed as part of the retrofit to ensure that they were performing as expected. The systems evaluated included the space conditioning heat pump, the air handler and ducts, the HPWH, the ICS SWH, and the PV array. Some ducts were untwisted after testing revealed that two rooms were not getting sufficient airflow. Afterwards, all systems were performing as expected. In addition to testing to confirm adequate performance of all new systems, NREL was given the opportunity to use the Greenbuilt house as a laboratory house for a year. The space conditioning system and home water systems were subjected to a series of tests to determine optimal control strategies for lowering energy consumption and reducing peak (4:00-7:00 p.m.) energy consumption during the summer. The different cooling strategies considered included two different precooling schedules, drawing the external shades during the day and using the whole-house fan at night, and combinations of those. The most effective strategy for reducing overall energy consumption was the use of external shades, which cut the daily cooling load by 34% and reduced the energy use during peak hours by 40%. The different precooling strategies eliminated the peak load entirely but actually increased daily cooling energy use. The use of shades and the advanced precooling strategy increased the daily energy use by 5% but eliminated all peak use and maintained a comfortable home. These results were verified over the entire summer using an Energy Plus model of the home. The hot water system was tested in two configurations: the HPWH alone and the ICS solar water heater paired with the HPWH. Six hot water draw profiles, varying in terms of daily hot water volume, time of day for hot water use, and the duration of the draws, were imposed on the hot water system to test their effects on performance. When operating alone in the summer, the HPWH operated with a COP around 2.2, except for a draw that used a quarter of the averaged daily hot water usage, which had an average COP of 1.6. The combination of ICS and HPWH resulted in larger COPs, but also more variability depending on the draw profile. The standard, hourly draw profile produced the highest COP of 6.4. The quarter volume draw profile had the lowest COP of 2.8 for the combined system. Relative to a standard electric water heater, the HPWH operating alone reduced the peak load by 56% and the combined ICS and HPWH system completely eliminated the peak load.

air sealing↗

Commercial PV Property Characterization: An Analysis of Solar Deployment Trends in Commercial Real Estate

The commercial rooftop solar energy market remains an under-developed sector. The market is estimated to contain 150 gigawatts of potential in the U.S. but it faces significant barriers to deployment to meet that potential, with an estimated 1.4 GW developed through 2017. This analysis focuses on of over 30,000 solar systems installed through 2017 and the properties on which they are located. The sample represents greater than 60% of the installed market at that time. The properties covered 20 states and almost 30 different types including industrial, warehouse, school/university, office, retail, and municipal/government and were compared to more than 2.4 million non-solar properties in the same geographies. The analysis finds overall commercial rooftop PV penetrations have only surpassed 1% recently across all property types with education properties (schools and universities) leading at over 6% penetration and with NJ and CA seeing the highest overall penetrations close to 2.5%. Also revealed were characteristics of those buildings, owners, and tenants and how solar penetrations change as those characteristics change. The research found clearly higher penetrations on owner-occupied larger (~9000 ft 2 ) buildings with fewer tenants indicating, potentially, areas for future customer acquisition for PV developers. Also investigated were differences of solar system characteristics on commercial buildings such as system installed prices, size, and percentages of third-party owned (TPO) systems. The research found a steady and substantial drop in installed prices over time, a drop in the percentage of TPO systems being installed, and a relatively steady trend of system size. This latter finding indicates that smaller systems remain difficult to develop.

14 SOLAR ENERGY↗