Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PRESSURE DROP”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 793 records · Page 44

CLOSURE OF HLW TANKS PHASE 2 FULL SCALE COOLING COILS GROUT FILL DEMONSTATIONS

This report documents the Savannah River National Laboratory (SRNL) support for the Tank Closure and Technology Development (TCTD) group's strategy for closing high level radioactive waste (HLW) tanks at the Savannah River Site (SRS). Specifically, this task addresses the ability to successfully fill intact cooling coils, presently within the HLW tanks, with grout that satisfies the fresh and cured grout requirements [1] under simulated field conditions. The overall task was divided into two phases. The first phase was the development of a grout formulation that satisfies the processing requirements for filling the HLW tank cooling coils [5]. The second phase of the task, which is documented in this report, was the filling of full scale cooling coils under simulated field conditions using the grout formulation developed in the first phase. SRS Type I tank cooling coil assembly design drawings and pressure drop calculations were provided by the Liquid Waste (LW) customer to be used as the basis for configuring the test assemblies. The current concept for closing tanks equipped with internal cooling coils is to pump grout into the coils to inhibit pathways for infiltrating water. Access to the cooling coil assemblies is through the existing supply/return manifold headers located on top of the Type I tanks. The objectives for the second phase of the testing, as stated in the Task Technical and Quality Assurance plan (TTQAP) [2], were to: (1) Perform a demonstration test to assess cooling coil grout performance in simulated field conditions, and (2) Measure relevant properties of samples prepared under simulated field conditions. SRNL led the actual work of designing, fabricating and filling two full-scale cooling coil assemblies which were performed at Clemson Engineering Technologies Laboratory (CETL) using the South Carolina University Research and Education Foundation (SCUREF) program. A statement of work (SOW) was issued to CETL [6] to perform this work.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Morphology of Nano and Micro Fiber Structures in Ultrafine Particles Filtration

Selected procedures permitting to prepare homogeneous nanofibre structures of the desired morphology by employing a suitable combination of variables during the electrospinning process are presented. A comparison (at the same pressure drop) was made of filtration capabilities of planar polyurethane nanostructures formed exclusively by nanofibres, space polycarbonate nanostructures having bead spacers, structures formed by a combination of polymethyl methacrylate micro- and nanofibres and polypropylene meltblown microstructures, through which ultrafine particles of ammonium sulphate 20-400 nm in size were filtered. The structures studied were described using a new digital image analysis technique based on black and white images obtained by scanning electron microscopy. More voluminous structures modified with distance microspheres and having a greater thickness and mass per square area of the material, i.e. structures possessing better mechanical properties, demanded so much in nanostructures, enable preparation of filters having approximately the same free volume fraction as flat nanofibre filters but an increased effective fibre surface area, changed pore size morphology and, consequently, a higher filter quality.

36 MATERIALS SCIENCE↗

Machine learning-based optimization of air-cooled heat sinks

Machine learning-based models using Artificial Neural Network (ANN) and greedy search algorithm are used to optimize air-cooled parallel plate-finned heat sinks (PPFHSs) subjected to laminar flow over an extensive range of design parameters. Here, the thermal and hydraulic performances of PPFHSs are represented by heat transfer coefficient (h) and pressure drop (ΔP), respectively. Optimization objectives for PPFHS designs can vary from industry to industry depending on their design priorities. The present study proposes a novel and generalized optimization method that defines practical optimization objectives and provides an accurate optimization process to design effective PPFHSs for a wide range of industrial applications with different design requirements. Three optimization objectives are presented in this study: (i) the largest h PΔ, (ii) the largest h within a specified maximum allowed flow rate, and (iii) the lowest weight that maximizes h for operation within the maximum allowed flow rate. While the shortcoming of the first objective is demonstrated, the other two objectives are found to be suitable for designing effective heat sinks (HSs) across different applications. Results suggest a promising trend from the third objective to develop HSs with ~ 37-68% lower weight, 80-85% reduced ΔP, and negligible penalty in h compared with optimized HSs obtained from the second objective. However, since the third objective leads to HSs with thinner fins, structural analysis should be performed to ensure reliable operation of the HSs.

42 ENGINEERING↗

A vented inverted fuel assembly design for an SFR

The inverted geometry (fuel outside coolant tubes) has been previously investigated at MIT for application in gas-cooled fast reactors and pressurized water-cooled thermal reactors. Venting has also been studied for conventional fuel pins and was employed for those in the Dounreay Fast Reactor. In the present work the inverted fuel approach was adopted because it allows high fuel volume fraction, reduction of the coolant void reactivity, neutron leakage and enrichment, as well as lower pressure drop for the same channel length because grids and wire wraps are no longer necessary. Furthermore most results also apply to venting of conventional fuel pins. Physical and chemical behavior of volatile fission products in sodium was investigated to determine the maximum activity inventory which would eventually be released into the primary sodium. Results of this analysis show that the most troublesome radionuclides in terms of propensity to escape from the venting system are noble gases ({sup 85}Kr and {sup 133}Xe), and cesium ({sup 134}Cs and {sup 137}Cs). A final vented inverted fuel assembly design is proposed which meets all the design goals which have been set. Additionally purification systems were devised to reduce radionuclide activity of the coolant and the cover gas to tolerable levels. It is concluded that vented inverted (or vented conventional pin) fuel is a feasible concept and has sufficiently promising advantages - increasing fuel volume fraction to 50% and core outlet temperature by 20 deg. C, hence incrementing plant thermal efficiency by about 1% - to warrant serious consideration for future SFR designs. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Effect of fast mold surface temperature evolution on iPP part morphology gradients

The control of mold surface temperature is an important factor that affects the sample surface morphology as well as the structural gradients (orientation crystal size, and type) as well as cooling stresses. The frozen layer thickness formed during the filling stage also has a very significant effect on the flow resistance and thus on the resulting pressure drop and flow length in thin wall parts. The possibility to have a hot mold during filling and a quick cooling soon afterward is a significant process enhancement particularly for specialized applications such as micro injection molding and for the reproduction of micro structured surfaces. Up to now, several methods (electromagnetic, infrared, hot vapor fleshing etc,) were tried to achieve fast temperature evolution of the mold. Unfortunately, all these methods require a complex balance between thermal and mechanical problems, equipment cost, energy consumption, safety, molding cycle time and part quality achievable. In this work, a thin electrical resistance was designed and used to generate a fast and confined temperature variation on mold surface (by joule effect). Since the whole temperature evolution can take place in a few seconds, one can couple the advantages of a high surface temperature during filling with the advantages of a low mold temperature, fast cooling and low heating dissipation. Some experiments were performed with a commercial iPP resin. The effects of the surface temperature and of the heating time (under constant electric power) on surface finishing and on the final morphology (thickness and structure of the different layers) are explored and discussed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Film thickness measurement techniques applied to micro-scale two-phase flow systems

Recently semi-empirical models to estimate flow boiling heat transfer coefficient, saturated CHF and pressure drop in micro-scale channels have been proposed. Most of the models were developed based on elongated bubbles and annular flows in the view of the fact that these flow patterns are predominant in smaller channels. In these models, the liquid film thickness plays an important role and such a fact emphasizes that the accurate measurement of the liquid film thickness is a key point to validate them. On the other hand, several techniques have been successfully applied to measure liquid film thicknesses during condensation and evaporation under macro-scale conditions. However, although this subject has been targeted by several leading laboratories around the world, it seems that there is no conclusive result describing a successful technique capable of measuring dynamic liquid film thickness during evaporation inside micro-scale round channels. This work presents a comprehensive literature review of the methods used to measure liquid film thickness in macro- and micro-scale systems. The methods are described and the main difficulties related to their use in micro-scale systems are identified. Based on this discussion, the most promising methods to measure dynamic liquid film thickness in micro-scale channels are identified. (author)

42 ENGINEERING↗

Accelerometers in flow fields: a structural analysis of the chopped dummy in-pile tube

Four tests characterizing the structural response of the Chopped-Dummy In-Pile tube (CDIPT) experiment design were measured in the Hydro-Mechanical Fuel Test Facility (HMFTF). Four different test configurations were tried. These configurations tested the pressure drop and flow impact of various plate configurations and flow control orifices to be used later at different reactor power levels. Accelerometers were placed on the test vehicle and flow simulation housing. A total of five accelerometers were used with one on the top and bottom of the flow simulator and vehicle, and one on the outside of the flow simulator. Data were collected at a series of flow rates for 5 seconds each at an acquisition rate of 2 kHz for a Nyquist frequency of 1 kHz. The data were then analyzed using a Fast Fourier Transform (FFT) algorithm. The results show very coherent vibrations of the CDIPT experiment on the order of 50 Hz in frequency and 0.01 m/s{sup 2} in magnitude. The coherent vibrations, although small in magnitude pose a potential design problem if the frequencies coincide with the natural frequency of the fueled plates or test vehicle. The accelerometer data was integrated and combined to create a 3D trace of the experiment during the test. The merits of this data as well as further anomalies and artifacts are also discussed as well as their relation to the instrumentation and experiment design. (authors)

42 ENGINEERING↗

Mixed Convection in the VHTR in the Event of a LOFA

The US Department of Energy, Office of Nuclear Energy (DOE-NE) is supporting the development of a very high temperature reactor (VHTR) concept as the primary focus of it next generation nuclear power plant (NGNP) program. The VHTR is cooled by forcing helium downwards through the core into the lower plenum and out the hot duct. In the event that the coolant circulators are lost, the driving pressure drop across the core will reduce to zero and there will be the opportunity for natural circulation to occur. During the time that the circulators are powering down, the heat transfer in the core from the graphite blocks to the helium coolant will transform from turbulent forced convection to mixed convection, where buoyancy effects become important, to free or natural convection, where buoyancy is dominant. Analysis of the nature of the forced, mixed and free convection is best done using computational fluid dynamic (CFD) software that can provide fine details of the flow and heat transfer. However, CFD analysis involves approximations in the results because of the finite nature of the spatial and temporal discretizations required, the inexact nature of the turbulence models that are used and the finite precision of the computers employed. Therefore, it is necessary to validate the CFD computations. Validation is accomplished by comparing results from specific CFD computations to experimental data that have been taken specifically for the purpose of validation and that are related to the physical phenomena in question. The present report examines the flow and heat transfer parameters (dimensionless numbers) that characterize the flow and reports ranges for their values based on specific CFD studies performed for the VHTR.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

BENCH SCALE SALTSTONE PROCESS DEVELOPMENT MIXING STUDY

The Savannah River National Laboratory (SRNL) was requested to develop a bench scale test facility, using a mixer, transfer pump, and transfer line to determine the impact of conveying the grout through the transfer lines to the vault on grout properties. Bench scale testing focused on the effect the transfer line has on the rheological property of the grout as it was processed through the transfer line. Rheological and other physical properties of grout samples were obtained prior to and after pumping through a transfer line. The Bench Scale Mixing Rig (BSMR) consisted of two mixing tanks, grout feed tank, transfer pump and transfer hose. The mixing tanks were used to batch the grout which was then transferred into the grout feed tank. The contents of the feed tank were then pumped through the transfer line (hose) using a progressive cavity pump. The grout flow rate and pump discharge pressure were monitored. Four sampling stations were located along the length of the transfer line at the 5, 105 and 205 feet past the transfer pump and at 305 feet, the discharge of the hose. Scaling between the full scale piping at Saltstone to bench scale testing at SRNL was performed by maintaining the same shear rate and total shear at the wall of the transfer line. The results of scaling down resulted in a shorter transfer line, a lower average velocity, the same transfer time and similar pressure drops. The condition of flow in the bench scale transfer line is laminar. The flow in the full scale pipe is in the transition region, but is more laminar than turbulent. The resulting plug in laminar flow in the bench scale results in a region of no-mixing. Hence mixing, or shearing, at the bench scale should be less than that observed in the full scale, where this plug is non existent due to the turbulent flow. The bench scale tests should be considered to be conservative due to the highly laminar condition of flow that exists. Two BSMR runs were performed. In both cases, wall shearing was shown to reduce the rheological properties of the grout as it was processed through the transfer line. Samples taken at the static feed tank showed that gelling impacted the rheological properties of the grout before it was fed into the pump and transfer line. A comparison of the rheological properties of samples taken at the feed tank and transfer line discharge indicated shearing of the grout was occurring in the transfer line. Bench scale testing of different mixing methods with three different salt solutions showed that method of mixing influences the rheological properties of the grouts. The paddle blade mixing method of the salt solution used for the BMSR testing provided comparable rheological properties of the grout prepared in the BMSR after 14 minutes of processing, B3. The paddle blade mixing method can be used to represent BMSR results and mixing time can be adjusted to represent larger scale mixing.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Linear and nonlinear instability in vertical counter-current laminar gas-liquid flows

We consider the genesis and dynamics of interfacial instability in vertical gas-liquid flows, using as a model the two-dimensional channel flow of a thin falling film sheared by counter-current gas. The methodology is linear stability theory (Orr-Sommerfeld analysis) together with direct numerical simulation of the two-phase flow in the case of nonlinear disturbances. We investigate the influence of two main flow parameters on the interfacial dynamics, namely the film thickness and pressure drop applied to drive the gas stream. To make contact with existing studies in the literature, the effect of various density contrasts is also examined. Energy budget analyses based on the Orr-Sommerfeld theory reveal various coexisting unstable modes (interfacial, shear, internal) in the case of high density contrasts, which results in mode coalescence and mode competition, but only one dynamically relevant unstable interfacial mode for low density contrast. A study of absolute and convective instability for low density contrast shows that the system is absolutely unstable for all but two narrow regions of the investigated parameter space. Direct numerical simulations of the same system (low density contrast) show that linear theory holds up remarkably well upon the onset of large-amplitude waves as well as the existence of weakly nonlinear waves. For high density contrasts, corresponding more closely to an air-water-type system, linear stability theory is also successful at determining the most-dominant features in the interfacial wave dynamics at early-to-intermediate times. Nevertheless, the short waves selected by the linear theory undergo secondary instability and the wave train is no longer regular but rather exhibits chaotic motion. The same linear stability theory predicts when the direction of travel of the waves changes — from downwards to upwards. We outline the practical implications of this change in terms of loading and flooding. The change in direction of the wave propagation is represented graphically in terms of a flow map based on the liquid and gas flow rates and the prediction carries over to the nonlinear regime with only a small deviation.

42 ENGINEERING↗

Analysis of Reverse Flow Restriction Device to Prevent Dryout Fuel Damage during BWR Instability

Boiling Water Reactors (BWRs) are subjected to instabilities due to thermal hydraulics feedback or coupled Neutronics-thermal hydraulics feedback. Feedback is affected by many reactor parameters that could destabilize the core such as distribution of pressure drop across the core, axial power shape, subcooling level at the core inlet, radial power peaking factor, reactivity coefficients, and others. There are three common modes of instability in BWRs: single channel instability, core-wide instability, and regional instability. Each instability mode could damage the fuel if the power oscillations are left without an intervention like reactor scram. However, the instability problem becomes more dangerous if the automatic reactor scram is lost, like in Anticipated Transient without Scram (ATWS) accidents. A reverse flow restriction device (RFRD) would mitigate this problem. Core simulation using TRACE/PARCS code has been used to examine the potential effect of restricting the flow in the downward direction on mitigation of the power and flow oscillations to increase the safety of BWRs. The presented results demonstrate the ability of the device on limiting flow oscillation amplitude in the one bundle where it is used, on an adjacent bundle without it and reducing the power peak when the flow is low and power is high during BWR power oscillations. This exercise demonstrates the potential of previously described hardware device on preventing clad temperature excursion to keep the fuel safe from dryout damage and provide encouraging results ahead of the planned more detailed investigation where the device is to be used in more bundles up to full core. In the future work it is planned to examine the effect of device installed in a fraction of the bundles on the flow rate in other bundles. Also, the effect on the characteristics of dryout and rewetting and the resulting temperature excursions with and without the device will be given special attention. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Experimental Data Sets for CFD Calculations of Flow and Heat Transfer in Deformed Fuel Assemblies

Liquid-metal fast-breeder reactors (LMFBRs) have traditionally used fuel assemblies consisting of a hexagonal array of pins enclosed in a hexagonally shaped duct. Each fuel pin is surrounded by a wire that is wrapped in a helical configuration, which is used to separate the pins sufficiently to allow sodium coolant to flow through the assembly. The helical wire wrap also promotes mixing of the coolant. Experience with these assemblies has shown that they begin to deform with time during normal operation leading to significant changes in core thermal-hydraulics. For example, deformations of assemblies in the Experimental Breeder Reactor-2 and the Fast Flux Test Facility led to pin overheating resulting from pin-to-duct and pin-to-pin contact. This problem is well known and was investigated extensively in the 1970's and early 1980's. This was a period, however, before the development of modern Computational Fluid Dynamics (CFD) computer codes. Therefore, the experiments performed at the time did not record their results in sufficient detail to be useful for compiling validation datasets for CFD codes. Most of the experiments focused only on bulk measurements, such as the pressure drop across the bundle. When the effects of deformation of the fuel assembly were investigated, the studies performed to quantify these effects considered only bare pins without the wire wrap. With the resurgence of interest in LMFBRs in recent years, particularly in designs that leverage long-life performance of the fuel, the need has arisen for data that are suitable for the validation and benchmarking of CFD codes to predict the thermal-hydraulic behavior of flow in wire-wrapped fuel bundles. Such data must include high-resolution, transient, full-field measurements of the fluid velocity and temperature and an accurate record of the test conditions, including a precise description of the geometry. This paper describes a project to produce a validation-quality set of data that can be used to benchmark CFD codes for modeling flow and thermal performance in wire-wrapped fuel assemblies of the kind used by LMFBR designs. In addition, this effort investigates the changes to the flow and other phenomena that occur in the deformed geometries that can form later in a fuel assembly's life. This work is a joint effort of four organizations. The experimental work is being performed by AREVA and Texas A and M University. The computational work, both to support the experiments and to perform blind benchmark calculations, is being done by TerraPower, LLC, and Argonne National Laboratory (ANL). The experiments use a geometry that consists of a complete assembly of 61 wire-wrapped pins, which is surrounded by a hexagonal duct. This configuration is considered the minimum size necessary to adequately capture the important results of interest, such as the thermal gradients across the assembly and the velocity field effects in the assembly resulting from the surrounding duct. These types of effects cannot be captured by a geometry consisting of only a small group of fuel pins. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Fuel Efficient Diesel Particulate Filter (DPF) Modeling and Development

The project described in this report seeks to promote effective diesel particulate filter technology with minimum fuel penalty by enhancing fundamental understanding of filtration mechanisms through targeted experiments and computer simulations. The overall backpressure of a filtration system depends upon complex interactions of particulate matter and ash with the microscopic pores in filter media. Better characterization of these phenomena is essential for exhaust system optimization. The acicular mullite (ACM) diesel particulate filter substrate is under continuing development by Dow Automotive. ACM is made up of long mullite crystals which intersect to form filter wall framework and protrude from the wall surface into the DPF channels. ACM filters have been demonstrated to effectively remove diesel exhaust particles while maintaining relatively low backpressure. Modeling approaches developed for more conventional ceramic filter materials, such as silicon carbide and cordierite, have been difficult to apply to ACM because of properties arising from its unique microstructure. Penetration of soot into the high-porosity region of projecting crystal structures leads to a somewhat extended depth filtration mode, but with less dramatic increases in pressure drop than are normally observed during depth filtration in cordierite or silicon carbide filters. Another consequence is greater contact between the soot and solid surfaces, which may enhance the action of some catalyst coatings in filter regeneration. The projecting crystals appear to provide a two-fold benefit for maintaining low backpressures during filter loading: they help prevent soot from being forced into the throats of pores in the lower porosity region of the filter wall, and they also tend to support the forming filter cake, resulting in lower average cake density and higher permeability. Other simulations suggest that soot deposits may also tend to form at the tips of projecting crystals due to the axial velocity component of exhaust moving down the filter inlet channel. Soot mass collected in this way would have a smaller impact on backpressure than soot forced into the flow restrictions deeper in the porous wall structure. This project has focused on the development of computational, analytical, and experimental techniques that are generally applicable to a wide variety of exhaust aftertreatment technologies. By helping to develop improved fundamental understanding pore-scale phenomena affecting filtration, soot oxidation, and NOX abatement, this cooperative research and development agreement (CRADA) has also assisted Dow Automotive in continuing development and commercialization of the ACM filter substrate. Over the course of this research project, ACM filters were successfully deployed on the Audi R10 TDI racecar which won the 24 Hours of LeMans endurance race in 2006, 2007, and 2008; and the 12 Hours of Sebring endurance race in 2006 and 2007. It would not have been possible for the R10 to compete in these traditionally gasoline-dominated events without reliable and effective exhaust particulate filtration. These successes demonstrated not only the performance of automotive diesel engines, but the efficacy of DPF technology as it was being deployed around the world to meet new emissions standards on consumer vehicles. During the course of this CRADA project, Dow Automotive commercialized their ACM DPF technology under the AERIFYTM DPF brand.

33 ADVANCED PROPULSION SYSTEMS↗

Stratification calculations in a heated cryogenic oxygen storage tank at zero gravity

A cylindrical one-dimensional model of the Apollo cyrogenic oxygen storage tank has been developed to study the effect of stratification in the tank. Zero gravity was assumed, and only the thermally induced motions were considered. The governing equations were derived from conservation laws and solved on a digital computer. Realistic thermodynamic and transport properties were used. Calculations were made for a wide range of conditions. The results show the fluid behavior to be dependent on the quantity in the tank or equivalently the bulk fluid temperature. For high quantities (low temperatures) the tank pressure rose rapidly with heat addition, the heater temperature remained low, and significant pressure drop potentials accrued. For low quantities the tank pressure rose more slowly with heat addition and the heater temperature became high. A high degree of stratification resulted for all conditions; however, the stratified region extended appreciably into the tank only for the lowest tank quantity.

Shuttles, J. T.↗

A simple, first step to the optimization of regenerator geometry

This paper presents a simplified set of equations for calculating and optimizing regenerator geometries. A number of competing parameters must be accounted for in the design of a regenerator. To obtain high values of effectiveness, there is need for a large surface area for heat transfer and high heat capacity. The void volume should be small to maintain the pressure ratio in the entire system. Moreover, the pressure drop should be small compared to the absolute pressure. With the assumptions made here, the calculations can be done with a hand calculator. The equations show that the optimum regenerator length, hydraulic radius, and porosity are independent of mass flow rate and the gas cross sectional area is proportional to the mass flow rate. It is shown that using gas gaps between parallel plates produces a significantly better regenerator than is possible with packed spheres or screens, particularly at temperatures below approximately 50%.

Radebaugh, R.↗

Space station common module thermal management: Design and construction of a test bed

In this project, a thermal test bed was designed, simulated, and planned for construction. The thermal system features interior and exterior thermal loads and interfacing with the central-radiator thermal bus. Components of the test bed include body mounted radiator loop with interface heat exchangers (600 Btu/hr); an internal loop with cabin air-conditioning and cold plates (3400 Btu/hr); interface heat exchangers to the central bus (13,000 Btu/hr); and provisions for new technology including advanced radiators, thermal storage, and refrigeration. The apparatus will be mounted in a chamber, heated with lamps, and tested in a vacuum chamber with LN2-cooled walls. Simulation of the test bed was accomplished using a DEC PRO 350 computer and the software package TK! olver. Key input variables were absorbed solar radiation and cold plate loads. The results indicate temperatures on the two loops will be nominal when the radiation and cold plate loads are in the range of 25% to 75% of peak loads. If all loads fall to zero, except the cabin air system which was fixed, the radiator fluid will drop below -100 F and may cause excessive pressure drop. If all loads reach 100%, the cabin air temperature could rise to 96 F.

Barile, R. G.↗

Stacked-Disk Combustor

Materials chosen for strength rather than thermal conductivity. Stacked washerlike disks accommodate built-in coolant passages while providing combustion zone of ideal shape. Fuel flows through coolant passages where preheated before entering combustion zone through passages in disks. Eight coolant passages in cross section, although number in particular application determined by required rate of flow of fuel and pressure drop. Combustion chamber operates for greater efficiency at pressures and temperatures higher than those of conventional tube-wall combustion chamber.

Ingle, Walter B.↗