Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PARTICLE DETECTOR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 793 records · Page 44

Solar Particle Events Observed by the Odyssey MARIE Instrument at Mars: Dose and Model Calculations

One of the primary concerns prior to human exploration of Mars is the need to accurately characterize the charged particle radiation environment both for the surface stay, and for the transit period to and from the planet. The Odyssey spacecraft, currently in Mars orbit includes a charged particle radiation detector, MARIE, which can measure particle fluxes with energies above approx. 30 MeV and charges between 1 and 10. Two classes of particles are of particular interest: the Galactic Cosmic Rays, (GCR), and those charged particles associated with Solar Particle Events, (SPE). The GCR are present continuously throughout the solar activity cycle, and their numbers vary inversely with the level of solar activity. They are characteristically more energetic than those particles originating from solar activity, and hence less influences by the solar magnetic field.

Cleghorn, T. F.↗

The suppression of charged-particle-induced noise in infrared detectors

A d.c.-coupled transimpedance amplifier/pulse suppression circuit designed to remove charged-particle-induced noise from infrared detectors is described. Noise spikes produced by single particle events are large and have short rise times, and can degrade the performance of an infrared detector in moderate radiation environments. The use of the suppression circuit improves the signal-to-noise ratio by a factor of 1.6:1, which corresponds to a reduction in required observing time by a factor of about 2.6.

Houck, J. R.↗

Detecting Foreign Particles in Wind Tunnels

Simple scratch test tells whether particles, which distort results, present in test. Detector developed for tests of abrasion resistance of flexible insulation blankets. Now, when detector indicates particles present in test, results interpreted accordingly. Small pits and scratches on metal foil indicate particles struck surface during wind-tunnel test. Detector used in tests of paints and coatings to determine whether abrasive particles present.

Sharp, H. L.↗

32 TeV pgun collisions, Double particles type, PARTICLE GUN generator: pgun_2pions_pi

Particle gun for detector studies: A particle gun for two pions separated by PI in Phi (i.e. back-to-back). The eta is set to 0. Production at (x,y,z,t)=(0,0,0,0). Charge is alternated. Uniform distribution in Phi between -PI and PI. This sample has several sabsamples with momenta p=2^n GeV, where n=1..15. The energy of each sample is included in the name of files. The sample was designed for detector studies.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

1 TeV pgun collisions, Double particles type, PARTICLE GUN generator: pgun_2klong_angle05

Particle gun for detector studies: A particle gun for two K-long mesons (KL, PID=130) separated by 0.5 degree. For every 20th events, the angular separation is reset to 0 degree, for easy tracking. The maximal separation is 10 degree. The eta is set to 0. Production at (x,y,z,t)=(0,0,0,0). Uniform distribution in Phi between -PI and PI. This sample has 3 subsamples for 10, 100 and 100 GeV energy (fixed). There are 100 files in each sample. The sample was designed for detector studies.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

30 GeV pgun collisions, Single particles type, PARTICLE GUN generator: pgun_elec_eta45_30gev

Single particle gun for detector studies: A particle gun with single electrons. One e+/e- per event. 5000 events per file. Production at (x,y,z,t)=(0,0,0,0). e+ and e- are alternated. Momentum is random from 0 to 30 GeV. Uniform distribution in Phi. Uniform distribution in the Eta (pseudorapidity) range [-4.5, 4.5]. This sample was prepared for the EIC detector studies (DIS)

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A CUPID Li2100MoO4 scintillating bolometer tested in the CROSS underground facility

A scintillating bolometer based on a large cubic Li$_{2}$$^{100}$MoO$_4$ crystal (45 mm side) and a Ge wafer (scintillation detector) has been operated in the CROSS cryogenic facility at the Canfranc underground laboratory in Spain. The dual-readout detector is a prototype of the technology that will be used in the next-generation $0\nu2\beta$ experiment CUPID. The measurements were performed at 18 and 12 mK temperature in a pulse tube dilution refrigerator. This setup utilizes the same technology as the CUORE cryostat that will host CUPID and so represents an accurate estimation of the expected performance. The Li$_{2}$$^{100}$MoO$_4$ bolometer shows a high energy resolution of 6 keV FWHM at the 2615 keV $\gamma$ line. The detection of scintillation light for each event triggered by the Li$_{2}$$^{100}$MoO$_4$ bolometer allowed for a full separation ($\sim$8$\sigma$) between $\gamma$($\beta$) and $\alpha$ events above 2 MeV. The Li$_{2}$$^{100}$MoO$_4$ crystal also shows a high internal radiopurity with $^{228}$Th and $^{226}$Ra activities of less than 3 and 8 $\mu$Bq/kg, respectively. Taking also into account the advantage of a more compact and massive detector array, which can be made of cubic-shaped crystals (compared to the cylindrical ones), this test demonstrates the great potential of cubic Li$_{2}$$^{100}$MoO$_4$ scintillating bolometers for high-sensitivity searches for the $^{100}$Mo $0\nu2\beta$ decay in CROSS and CUPID projects.

47 OTHER INSTRUMENTATION↗

Electronics for a Picosecond Time-of-flight Measurement

TITLE: Electronics for a Picosecond Time-of-flight Measurement ABSTRACT: Time-of-flight (TOF) detectors have historically been used as part of the particle identification capability of multi-purpose particle physics detectors. An accurate time measurement, combined with a momentum measurement based on the curvature of the track in a magnetic field, is often sufficient to determine the particle's mass, and thus its identity. Such detectors typically have measured the particle flight time extremely precisely, with an uncertainty of one hundred trillionths of a second (also referred to as 100 picoseconds). To put this in perspective it would be like counting all the people on the Earth and getting it right within 1 person! Another use of TOFs is to measure the vertex of the event, which is the location along the beam line where the incoming particles (typically protons) collide. This vertex positon is a well measured quantity for events where the protons collide “head on” as the outgoing particles produced when you blast the proton apart can be used to trace back to a vertex point from which they originated. More frequently the protons just strike a glancing blow and remain intact—in this case they are nearly parallel to the beam and you cannot tell their vertex without this ability to precisely measure the time of flight of the protons. Occasionally both happen in the same event, that is, a central system and two protons are produced. But are they from the same collision, or just a boring background where more than one collision in the same bunch crossing conspire to fake the signal of interest? That’s where the timing of the protons comes into play. The main idea is to measure the time it takes for the two protons to reach TOF detectors positioned equidistant from the center of the main detector. If the vertex is displaced to one side than that detector will measure a shorter time while the other side detector will measure a correspondingly longer time. Taking into account the speed of the particles, which is very close to the speed of light, an accuracy of 100 ps gives a vertex measurement of a few cm or a little more than an inch. At the Large Hadron Collider, where there are up to a hundred billion protons per bunch, and the collision region is compressed to a few inches, that is just not good enough. A higher level of precision is needed to determine whether the vertex of the protons and that of the central system are the same. A factor 10 improvement in the timing measurement to the 10 trillionths of a second level, for example would give the requisite 10 times improvement in the vertex measurement. An accurate measurement of the flight time depends on three key elements: the radiator that produces light when the proton passes through it, the photo-sensor that converts the light to an electrical signal, and the electronics that convert this electrical signal into a time measurement with a compact recordable format. With recent improvements in detector design featuring a series of quartz radiators connected to a micro-channel plate photomultiplier tube, this superior measurement capability is within reach if the readout electronics are sufficiently performant. As a result of the funding of this proposal, we have achieved our primary goals. 1) We have developed from scratch or improved upon existing designs of the full chain of electronics that can maintain the performance of a TOF detector from the output of the photo-sensor to the recording of a compressed data packet containing the timing information. We have accomplished this with a cost effective modular approach such that some or all of the components in the chain could easily be adapted for use in diverse particle physics experiments or in other areas where precise timing is required, such as medical and homeland security devices.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Second-Order Sensitivity Analysis of Uncollided Particle Contributions to Radiation Detector Responses

This work presents an application of Cacuci’s Second-Order Adjoint Sensitivity Analysis Methodology (2nd-ASAM) to the simplified Boltzmann equation that models the transport of uncollided particles through a medium to compute efficiently and exactly all of the first- and second-order derivatives (sensitivities) of a detector’s response with respect to the system’s isotopic number densities, microscopic cross sections, source emission rates, and detector response function. The off-the-shelf PARTISN multigroup discrete ordinates code is employed to solve the equations underlying the 2nd-ASAM. The accuracy of the results produced using PARTISN is verified by using the results of three test configurations: (1) a homogeneous sphere, for which the response is the exactly known total uncollided leakage, (2) a multiregion two-dimensional (r-z) cylinder, and (3) a two-region sphere for which the response is a reaction rate. For the homogeneous sphere, results for the total leakage as well as for the respective first- and second-order sensitivities are in excellent agreement with the exact benchmark values. For the nonanalytic problems, the results obtained by applying the 2nd-ASAM to compute sensitivities are in excellent agreement with central-difference estimates. The efficiency of the 2nd-ASAM is underscored by the fact that, for the cylinder, only 12 adjoint PARTISN computations were required by the 2nd-ASAM to compute all of the benchmark’s 18 first-order sensitivities and 224 second-order sensitivities, in contrast to the 877 PARTISN calculations needed to compute the respective sensitivities using central finite differences, and this number does not include the additional calculations that were required to find appropriate values of the perturbations to use for the central differences.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

1 TeV pgun collisions, Single particles type, PARTICLE GUN generator: pgun_eta0_b0

Particle gun for detector studies: A particle gun for single pions and deutrons. The eta and phi is set to 0. Production at (x,y,z,t)=(0,0,0,0). Charge is alternated. The momenta and the particle ID is given in the file name. The full Geant simulation is performed assuming no magnetic field (B=0). The sample is designed for timing studies. Each file has 50k events (only 1 TeV sample will have 10k events). Comment on full simulation: While the baseline detector is SiFcc-7, the B-field for rfull009 tag was set to 0. The sample was designed for calorimeter studies, and we expect that the charged particles entering the calorimeter have exactly eta=phi=0. The sample is designed for timing studies.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The High Voltage distribution system of the ATLAS Tile Calorimeter and its performance during data taking

This study documents the characteristics of the high voltage (HV) system of the hadronic calorimeter TileCal of the ATLAS experiment. Such a system is suitable to supply reliable power distribution into particles physics detectors using a large number of PhotoMultiplier Tubes (PMTs). Measurements performed during the 2015 and 2016 data taking periods of the ATLAS detector show that its performance, in terms of stability and noise, fits the specifications. In particular, almost all the PMTs show a voltage instability smaller than 0.5 V corresponding to a gain stability better than 0.5%. A small amount of channels was found not working correctly. To diagnose the origin of such defects, the results of the HV measurements were compared to those obtained using a Laser system. The analysis shows that less than 0.2% of the about 10 thousand HV channels were malfunctioning.

47 OTHER INSTRUMENTATION↗

Fine-tuning machine-learned particle-flow reconstruction for new detector geometries in future colliders

We demonstrate transfer learning capabilities in a machine-learned algorithm trained for particle-flow reconstruction in high energy particle colliders. This paper presents a cross-detector fine-tuning study, where we initially pretrain the model on a large full simulation dataset from one detector design, and subsequently fine-tune the model on a sample with a different collider and detector design. Specifically, we use the Compact Linear Collider detector (CLICdet) model for the initial training set and demonstrate successful knowledge transfer to the CLIC-like detector (CLD) proposed for the Future Circular Collider in electron-positron mode. We show that with an order of magnitude less samples from the second dataset, we can achieve the same performance as a costly training from scratch, across particle-level and event-level performance metrics, including jet and missing transverse momentum resolution. Furthermore, we find that the fine-tuned model achieves comparable performance to the traditional rule-based particle-flow approach on event-level metrics after training on 100,000 CLD events, whereas a model trained from scratch requires at least 1 million CLD events to achieve similar reconstruction performance. To our knowledge, this represents the first full-simulation cross-detector transfer learning study for particle-flow reconstruction. These findings offer valuable insights towards building large foundation models that can be fine-tuned across different detector designs and geometries, helping to accelerate the development cycle for new detectors and opening the door to rapid detector design and optimization using machine learning.

43 PARTICLE ACCELERATORS↗

Discrimination of electronic recoils from nuclear recoils in two-phase xenon time projection chambers

We present a comprehensive analysis of electronic recoil vs. nuclear recoil discrimination in liquid/gas xenon time projection chambers, using calibration data from the 2013 and 2014-16 runs of the Large Underground Xenon (LUX) experiment. We observe strong charge-to-light discrimination enhancement with increased event energy. For events with S1 = 120 detected photons, i.e. equivalent to a nuclear recoil energy of ~100 keV, we observe an electronic recoil background acceptance of <10 –5 at a nuclear recoil signal acceptance of 50%. We also observe modest electric field dependence of the discrimination power, which peaks at a field of around 300 V/cm over the range of fields explored in this study (50-500 V/cm). In the WIMP search region of S1 = 1-80 phd, the minimum electronic recoil leakage we observe is (7.3 ± 0.6) 10 –4 , which is obtained for a drift field of 240-290 V/cm. Pulse shape discrimination is utilized to improve our results, and we find that, at low energies and low fields, there is an additional reduction in background leakage by a factor of up to 3. We develop an empirical model for recombination fluctuations which, when used alongside the Noble Element Scintillation Technique (NEST) simulation package, correctly reproduces the skewness of the electronic recoil data. We use this updated simulation to study the width of the electronic recoil band, finding that its dominant contribution comes from electron-ion recombination fluctuations, followed in magnitude of contribution by fluctuations in the S1 signal, fluctuations in the S2 signal, and fluctuations in the total number of quanta produced for a given energy deposition.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Reflectance and fluorescence characteristics of PTFE coated with TPB at visible, UV, and VUV as a function of thickness

Polytetrafluoroethylene (PTFE) is an excellent diffuse reflector widely used in light collection systems for particle physics experiments. In noble element systems, it is often coated with tetraphenyl butadiene (TPB) to allow detection of vacuum ultraviolet scintillation light. Here, in this work this dependence is investigated for PTFE coated with TPB in air for light of wavelengths of 200 nm, 260 nm, and 450 nm. The results show that TPB-coated PTFE has a reflectance of approximately 92% for thicknesses ranging from 5 mm to 10 mm at 450 nm, with negligible variation as a function of thickness within this range. A cross-check of these results using an argon chamber supports the conclusion that the change in thickness from 5 mm to 10 mm does not affect significantly the light response at 128 nm. Our results indicate that pieces of TPB-coated PTFE thinner than the typical 10 mm can be used in particle physics detectors without compromising the light signal.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗