Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Optical elements”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 793 records · Page 44

Particle Scattering in the Resonance Regime: Models Based on Integral Equations and Hybrid Finite Elements - Integral Equation Techniques

Reliable descriptions of the optical properties of clouds and aerosols are essential for studies of radiative transfer in the terrestrial atmosphere...Here we explore the utility of two approaches for deriving the single scattering optical properties of particles with sharp corners and large axial ratios.

clouds aerosols axi-symmetric particles resonance ↗

Structural and optical properties for typical solid mirror shapes

A method is developed to determine the weight, center of gravity, areal properties, and mass inertial properties for typical mirrors. A number of support conditions were considered to examine optical surface deflections, surface quality, and fundamental natural frequency for single- and double-arch mirror shapes. Structural performance estimates were made with the NASTRAN program, and optical performances were evaluated with the FRINGE program, using an SXA 40-in mirror. To show the behavior of element types from the NASTRAN program, finite element validity and sensitivity studies were performed in optical model applications. Material parameters, contoured back shapes, and support locations are shown to have significant effects on structural and optical performances. Optimal support locations and support points are given. Fundamental natural frequencies for some shapes are found with the closed-form solution. The plate models results may not be acceptable for determining real mirror optical performances.

Cho, Myung K.↗

Effect of Ceramic Ball and Hybrid Stainless Steel Bearing/Wheel Combinations on the Lifetime of a Precision Translation Stage for the SIM Flight Project

A study of hybrid material couples using the Spiral Orbit Tribometer (SOT) was initiated to investigate both lubricated (Pennzane X2000 and Brayco 815Z) and unlubricated Si3N4, 440C SS, Rex 20, Cronidur X30 and X40 plates with Cerbec SN-101-C (Si3N4) and 440C balls. The hybrid wheel/bearing assembly will be used on the Linear Optical Delay Line (LODL) stage as an element of the NASA Space Interferometry Mission (SIM). SIM is an orbiting interferometer linking a pair of telescopes within the spacecraft and, by using an interferometry technique and several precision optical stages, is able to measure the motions of known stars much better than current ground or space based systems. This measurement will provide the data to "infer" the existence of any plants, undetectable by other methods, orbiting these known stars.

Lo, C. John↗

Numerical Modeling of Ocular Dysfunction in Space

Upon introduction to microgravity, the near-loss of hydrostatic pressure causes a marked cephalic (headward) shift of fluid in an astronaut's body. The fluid shift, along with other factors of spaceflight, induces a cascade of interdependent physiological responses which occur at varying time scales. Long-duration missions carry an increased risk for the development of the Visual Impairment and Intracranial Pressure (VIIP) syndrome, a spectrum of ophthalmic changes including posterior globe flattening, choroidal folds, distension of the optic nerve sheath, kinking of the optic nerve and potentially permanent degradation of visual function. In the cases of VIIP found to date, the initial onset of symptoms occurred after several weeks to several months of spaceflight, by which time the gross bodily fluid distribution is well established. We are developing a suite of numerical models to simulate the effects of fluid shift on the cardiovascular, central nervous and ocular systems. These models calculate the modified mean volumes, flow rates and pressures that are characteristic of the altered quasi-homeostatic state in microgravity, including intracranial and intraocular pressures. The results of the lumped models provide initial and boundary data to a 3D finite element biomechanics simulation of the globe, optic nerve head and retrobulbar subarachnoid space. The integrated set of models will be used to investigate the evolution of the biomechanical stress state in the ocular tissues due to long-term exposure to microgravity.

intraocular pressure↗

Microgravity-Driven Optic Nerve/Sheath Biomechanics Simulations

Visual Impairment and Intracranial Pressure (VIIP) syndrome is a concern for long-duration space flight. Current thinking suggests that the ocular changes observed in VIIP syndrome are related to cephalad fluid shifts resulting in altered fluid pressures [1]. In particular, we hypothesize that increased intracranial pressure (ICP) drives connective tissue remodeling of the posterior eye and optic nerve sheath (ONS). We describe here finite element (FE) modeling designed to understand how altered pressures, particularly altered ICP, affect the tissues of the posterior eye and optic nerve sheath (ONS) in VIIP. METHODS: Additional description of the modeling methodology is provided in the companion IWS abstract by Feola et al. In brief, a geometric model of the posterior eye and optic nerve, including the ONS, was created and the effects of fluid pressures on tissue deformations were simulated. We considered three ICP scenarios: an elevated ICP assumed to occur in chronic microgravity, and ICP in the upright and supine positions on earth. Within each scenario we used Latin hypercube sampling (LHS) to consider a range of ICPs, ONH tissue mechanical properties, intraocular pressures (IOPs) and mean arterial pressures (MAPs). The outcome measures were biomechanical strains in the lamina cribrosa, optic nerve and retina; here we focus on peak values of these strains, since elevated strain alters cell phenotype and induce tissue remodeling. In 3D, the strain field can be decomposed into three orthogonal components, denoted as first, second and third principal strains. RESULTS AND CONCLUSIONS: For baseline material properties, increasing ICP from 0 to 20 mmHg significantly changed strains within the posterior eye and ONS (Fig. 1), indicating that elevated ICP affects ocular tissue biomechanics. Notably, strains in the lamina cribrosa and retina became less extreme as ICP increased; however, within the optic nerve, the occurrence of such extreme strains greatly increased as ICP was elevated (Fig. 2). In particular, c. 48 of simulations in the elevated ICP condition showed peak strains in the optic nerve that exceeded the strains expected on earth. Such extreme strains are likely important, since they represent a larger signal for mechano-responsive resident cells [2]. The models predicted little to no anterior motion of the prelaminar neural tissue (optic nerve swelling, or papilledema, secondary to axoplasmic stasis), typically seen with elevated ICP. Specialized FE models to capture axoplasmic stasis would be required to study papilledema. These results suggest that the most notable effect of elevated ICP may occur via direct optic nerve loading, rather than through connective tissue deformation. These FE models can inform the design of future studies designed to bridge the gap between biomechanics and pathophysiological function in VIIP.

biomechanics↗

The explosive transient camera (ETC) - An instrument for identification of gamma ray burst optical counterparts

The ETC is a wide-field (3-steradian) electronic camera array which can detect coincident optical flashes with durations of 0.1 to 100 sec. Each array element is a 20 x 30 deg FOV, cooled CCD detector. An optical transient (possibly associated with a gamma ray burst) as faint as B = +11 (1 sec duration) can be detected with an S/N of not less than 20, and its position determined to an accuracy of + or - 10 arcsec. Candidate events 1000 times fainter than the archived event (plate taken in 1928) reported for the November 19, 1978 gamma ray burst by Schaefer (1981) should be detectable in real time. A prototype camera was tested in April 1982 to establish sky background levels and spurious event rejection schemes; a 1/2-ster test version of the ETC was planned for operation in early 1984; expansion to the full 3-ster complement of 16 detectors at each of two sites was planned for the 1984-1985 period.

Ricker, G. R.↗

Phased-Array Antenna With Optoelectronic Control Circuits

Prototype phased-array antenna features control of amplitude and phase at each radiating element. Amplitude- and phase-control signals transmitted on optical fiber to optoelectronic interface circuit (OEIC), then to monolithic microwave integrated circuit (MMIC) at each element. Offers advantages of flexible, rapid electronic steering and shaping of beams. Furthermore, greater number of elements, less overall performance of antenna degraded by malfunction in single element.

Kunath, Richard R.↗

Josephson frequency meter for millimeter and submillimeter wavelengths

Frequency measurements of electromagnetic oscillations of millimeter and submillimeter wavebands with frequency growth due to a number of reasons become more and more difficult. First, these frequencies are considered to be cutoffs for semiconductor converting devices and one has to use optical measurement methods instead of traditional ones with frequency transfer. Second, resonance measurement methods are characterized by using relatively narrow bands and optical ones are limited in frequency and time resolution due to the limited range and velocity of movement of their mechanical elements as well as the efficiency of these optical techniques decrease with the increase of wavelength due to diffraction losses. That requires a priori information on the radiation frequency band of the source involved. Method of measuring frequency of harmonic microwave signals in millimeter and submillimeter wavebands based on the ac Josephson effect in superconducting contacts is devoid of all the above drawbacks. This approach offers a number of major advantages over the more traditional measurement methods, that is one based on frequency conversion, resonance and interferometric techniques. It can be characterized by high potential accuracy, wide range of frequencies measured, prompt measurement and the opportunity to obtain a panoramic display of the results as well as full automation of the measuring process.

Anischenko, S. E.↗

The PCM is Dead! Long Live O-PCM!

The ability to reconfigure the optical behavior of a device enables free-space applications ranging from imaging to sensing and signal control. Such optical devices can be compacted via meta-surfaces, patterned structures with feature sizes below the incident wavelength. Leveraging geometry in addition to material properties and CMOS fabrication techniques has allowed meta-surfaces for lenses, holograms, beam steerers and more. To incorporate multiple optical functions into one device, various methods of device control have been implemented, such as stretching of flexible substrates, tuning the refractive index of the comprising meta-atoms via the electro-optic or the thermo-optic effects, phase transition materials such as VO2 and more. Chalcogenide glasses used as optical phase change materials, such as Ge¬2Sb2Te5 (GST), have gained increased traction in the optics community for potential use in the near infrared (NIR) and mid infrared (MIR) bands, including the telecom bands. Various chalcogenides such as Sb2Se3, Sb2S3, Ge2Sb¬2Se5 and Ge2Sb2Se4Te (GSST) have been investigated due to their broad NIR or MIR transparency window and large changes in refractive index. In their amorphous phase, these materials usually display a lower refractive index and low absorption when compared to their crystalline state which display a higher refractive index and typically larger extinction coefficients. The amorphous-crystalline reversible switching can be done via fast melt-quenching thermal processes triggered by laser or electrical impulses, relying on a substrate as a heat sink. The potential of PCMs in photonic devices can be limited by intrinsic material limitations as well as by device fabrication issues. To explore the cyclability of GSST, a PCM with large refractive index contrast and on-chip electrothermal switching on a silicon-on-insulator platform has been done to analyze potential failure mechanisms from both a material and device perspective. A brief outline of the instrumentation and phase change contrast analysis is provided. Dewetting of the PCM, delamination of and damage in the PECVD SiNx protective layer, elemental migration in the PCM and optical contrast decay have been observed in cycled GSST devices. Guidelines for device performance improvement are proposed, and an improved design with larger endurance is shown in progress.

reconfigurable photonics↗

Mirror Tech Days (11/02/2021)Next Generation Astronomical X-ray Optics:High Resolution, Light Weight, & Low Cost

We have demonstrated the basic elements of a technology to make high-resolution, light-weight, and low-cost X-ray optics. We continue to advance this technology to meet all requirements of Lynx: performance and programmatic. This technology uses only commercially available equipment and materials. It piggybacks on the semiconductor industry, avoiding obsolescence and ensuring continual advance. This technology can be used for missions of all sizes: sub-orbital, SmallSats, Pioneers, SMEX, MIDEX, Probes, and Flagships(Lynx).

X-Ray↗

The optical implementation of inner product neural associative memory

A liquid-crystal TV spatial light modulator (LCTV SLM) input device and LCTV nonlinear thresholding element are presently used to accomplish an all-optical implementation of an inner-product neural associative memory. This architecture represents an alternative to the vector-matrix multiplication method of the Hopfield model, which is most often employed by neural network associative memory models. LCTV SLM experimental results are presented and discussed.

Liu, Hua-Kuang↗

Transition Experiments on Blunt Bodies with Isolated Roughness Elements in Hypersonic Free Flight

Smooth titanium hemispheres with isolated three-dimensional (3D) surface roughness elements were flown in the NASA Ames hypersonic ballistic range through quiescent CO2 and air environments. Global surface intensity (temperature) distributions were optically measured and thermal wakes behind individual roughness elements were analyzed to define tripping effectiveness. Real-gas Navier-Stokes calculations of model flowfields, including laminar boundary layer development in these flowfields, were conducted predict key dimensionless parameters used to correlate transition on blunt bodies in hypersonic flow. For isolated roughness elements totally immersed within the laminar boundary layer, critical roughness Reynolds numbers for flights in air were found to be higher than those measured for flights in CO2, i.e., it was easier to trip the CO2 boundary layer to turbulence. Tripping effectiveness was found to be dependent on trip location within the subsonic region of the blunt body flowfield, with effective tripping being most difficult to achieve for elements positioned closest to the stagnation point. Direct comparisons of critical roughness Reynolds numbers for 3D isolated versus 3D distributed roughness elements for flights in air showed that distributed roughness patterns were significantly more effective at tripping the blunt body laminar boundary layer to turbulence.

Reda, Daniel C.↗

Development of Large Bandgap Materials Using Reactive Growth in Al-SI Eutectic for Optical and RF Applications

Carbon was utilized as reactive element to modify the microstructure using forced mixing during crystallization of the Al-Si alloy by rotation and stirring. We nucleated the material on SiC substrates while the Al-Si melt was rotated with a speed of 30rpm in a graphite crucible. Several experiments were performed and parameters such as time of mixing, soaking temperature, rotation rate of the substrate and rate of cooling during the solidification was changed. We observed dendrite and cell morphologies during the solidification of rotating melt. The microstructure was characterized by optical microscopy and SEM-EDX and compositional spectroscopy. The effect of carbon impurities was studied on the solidifying microstructure. When we used the longer soak time of the melt in presence of carbon impurities we observed the destruction of dendritic morphology and the formation of cellular and colony structures. Similar approach has been used for Ga2O3, a novel large bandgap material also.

Singh, N. B.↗

Dielectric prisms would improve performance of quasi-optical microwave components

Properties of the Brewster angle and internal reflection in a dielectric prism are proposed as the basis of a new type of element for use in oversize waveguide in quasi-optical microwave components. Waveguide loss is reduced and precision broadband attenuators, phase shifters, and directional couplers can be constructed on the basis of the properties.

Carson, J. W.↗

Long range laser traversing system

The relative azimuth bearing between first and second spaced terrestrial points which may be obscured from each other by intervening terrain is measured by placing at one of the points a laser source for projecting a collimated beam upwardly in the vertical plane. The collimated laser beam is detected at the second point by positioning the optical axis of a receiving instrument for the laser beam in such a manner that the beam intercepts the optical axis. In response to the optical axis intercepting the beam, the beam is deflected into two different ray paths by a beam splitter having an apex located on the optical axis. The energy in the ray paths is detected by separate photoresponsive elements that drive logic networks for proving indications of: (1) the optical axis intercepting the beam; (2) the beam being on the left of the optical axis and (3) the beam being on the right side of the optical axis.

Caudill, L. O.↗

Dually-mode-locked ND: YAG laser

Mode-locking is stabilized effectively by conventional loss-modulator and phase-modulator, mode-locking elements placed in laser cavity in optical series with one another. Resulting dually-mode-locked system provides pulses with constant phase relative to mode-lock drive signal without presence of relaxation oscillation noise.

Osmundson, J.↗

Emission-line strengths and the chemical compositions of quasi-stellar objects

Estimates of emission-line strengths in 160 QSOs are listed. They are used, together with those for 60 objects published earlier, to compile a table of rest-frame equivalent widths for a composite QSO containing 28 lines seen in objects with z from 0.06 to 3.53. Models are computed for matter partially filling a spherical volume, ionized by ultraviolet flux from a central object and optically thick with absorption from heavy elements taken into account. Constant temperature and density are taken for the He II region, where most of the important lines are emitted. Allowance is made for lower and higher temperatures in the H I and He III regions. Emergent emission-line equivalent widths are computed and compared with the observations. An abnormally low helium abundance is not needed to achieve a fit, since the only anomalously weak line is He II 4686 A whose upper level may be depopulated by stimulated emission of He II 1215 A caused by very strong L-alpha 1216 A flux.

Chan, Y.-W. T.↗

The Large Space Telescope - A new adventure

A description is presented of the Large Space Telescope (LST), which will be launched in 1982 and can accomodate four scientific instruments at any given time, permitting spectrographic and photometric observations between 1200 A in the UV and 1 mm in the IR. Basic elements of the LST are the optical telescope assembly, the scientific instruments (cameras, spectrographs, photometers, and an astrometer), and the support-systems module. Developmental as well as observational considerations are discussed, including various approaches to testing, maintenance, data transmission and processing, instrument calibration, housekeeping, and refurbishment. A possible mission scenario is outlined.

Friedlaender, F. M.↗