Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Nuclear Data Sensitivities”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 793 records · Page 44

Assessment of Thin Plastic Scintillation Detectors for Beta-Particle Measurements at the Advanced Test Reactor Critical Facility

The Fission Wire Measurement System is a custom measurement system designed in the 1960s to measure the beta-particle activity of irradiated uranium-aluminum fission wires. This measurement is conducted to determine the fission rate profile of the Advanced Reactor Test Critical facility. The Advanced Test Reactor Critical facility is an open-pool, low-power test reactor used to qualify experiment configurations and verify core models prior to full-power experiment irradiations in the Advanced Test Reactor. Power distribution measurements in ATR-C use uranium-aluminum wires that are distributed throughout the core to validate simulation and modeling results. These measurements require from 340 to 1500 wires to be irradiated and measured within a 12-hour window. The system consists of 4 measurement channels and one reference channel, each with a 2-pi proportional gas flow detector and the measurement channels each have an automated sample changer. The gas flow detectors are of a custom design for this detector system that use methane gas with a large anode wire compared to modern proportional counters. These detectors, which are nearly 60 years old are irreplaceable. The measurements from these gas detectors are affected by the gas flow rate, atmospheric and line pressure, and are very sensitive to the applied high voltage. Recent improvements have been made to the control and data acquisition system, but the detectors have remained the same. The nature of the measurement of the fission product decay activity is such that the energy spectrum of the signal is changing with time. Thin, 250-um thick, plastic scintillators were commercially obtained as a potential replacement for the gas flow detectors. The original calibration of the uranium-aluminum fission wires was conducted in 1965 using a series of irradiations of gold foils and the wires in a well-characterized thermal neutron field. These measurements provided a time-dependent fission rate conversion factor from the gold foil data to calibrate the fission wires based on the response from the 2-pi proportional gas detectors. Transitioning to the new detectors requires qualification and testing. The sensitivity of the scintillators to changes in the energy spectrum of the fission wires and translation of the calibration factor have been completed. These measurements indicated that the sensitivity of the scintillators over time changes at a different rate than the sensitivity of the gas flow detectors. However, the inverse activity of measurements of both detector types is linear with time. Initial results indicate that the scintillator detectors will be a sufficient replacement for the gas detectors with minor adjustments to the fission rate conversion factor. Replacement of the detectors will improve the fission wire measurements and provide a more stable and reliable measurement system.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Survey of Aging and Monitoring Concerns for Cables and Splices Due to Cable Repair and Replacement

The purpose of this report is to survey aging and monitoring concerns for electrical cable splices in nuclear power plants (NPPs) in long term operation. As portions of existing electrical cable runs in nuclear are replaced over time due to localized events, the total number of splices in NPPs is expected to increase. Relative to cables, the body of knowledge regarding aging of splices and splices in combination with aging cables in nuclear service environments in long-term operations is low. A few reports have considered the aging of cable system components other than cables (Jacobus 1990; Nelson 1998; Villaran and Lofaro 2002), but the nuclear industry has two decades of operating experience since these were published to further enlighten this issue. Herein we discuss electrical cables and splices commonly found in U.S. nuclear power plants, their qualification in safety-related application, and methods for monitoring their health condition. Common environmental stresses that can give rise to cable and splice failure are discussed. The Nuclear Regulatory Commission (NRC) Licensee Event Reports (LER) database was used to identify documented issues of cable and splice failure. The trend in the resultant data over time is considered to see if failures are increasing as plants age. Observations and conclusions of this work include: 1. Cables and splices are highly reliable components. Occurrence rates for events of interest were low and nearly constant over the last 20 years. 2. Common-cause failure for evaluated cable events of interest was observed to primarily be associated with loose connections, which may manifest associated with workmanship issues, thermal cycling, and/or vibration. 3. Replacement of cables is more common than repair, leading to an increase in proportion of new generation cables in the plant over time. 4. Splices on degraded cables have been observed to be problematic. Due to aging NPP infrastructure, including electrical cables, it is expected that such issues will continue to increase. 5. Condition monitoring approaches, while shown to be fruitful for cables, have been shown to be insensitive to degradation of splice sleeves, which are critical to the continued performance of splices. Additional condition monitoring (CM) work is needed to evaluate methods which are sensitive to the degradation of splice components. 6. Extended Material Degradation Assessment (EMDA) knowledge gaps for electrical cables (Bernstein et al. 2014) have not been investigated for splices but may represent similar concerns such as for the accelerated aging process historically used in environmental qualification.

42 ENGINEERING↗

Consistency of nucleon-transfer sum rules in well-deformed nuclei

Here, nucleon-transfer sum rules have been assessed via a consistent reanalysis of cross-section data from neutron-adding (d, p) and -removing (d, t) reactions on well-deformed isotopes of Gd, Dy, Er, Yb, and W, with 92 ≤ N ≤ 108 , studied at the Niels Bohr Institute in the 1960s and 1970s. These are complemented by new measurements of cross sections using the (d, p), (d, t), and (p, d) reactions on a subset of these nuclei. The sum rules, defined in a Nilsson-model framework, are remarkably consistent. A single overall normalization is used in the analysis, which appears to be sensitive to assumptions about the reaction mechanism, and in the case of sums using the (d, t) reaction, differs from values determined from reactions on spherical systems.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Immobilization of Uranium in a Wetland 8-km Downstream from an Industrial Source (Report)

A three-day walk-over survey with portable gamma detecting equipment was conducted over a uranium-contaminated wetland located 8-km downstream from a former fuel fabrication facility. 97,000 spectra were collected, individually processed to extract uranium activity data, and then integrated with topographical information (LIDAR) to create maps. These maps reveal that 50 years after being released into the environment, 11% of the uranium is retained in the 9-ha wetland area. Combined with measurement collected closer to the source, it was determined that 94% of the released uranium is presently being held in downstream wetlands. This demonstrates that wetlands can be very effective at immobilizing contaminants for long durations. The survey also showed that previous flyover maps overestimated the size of the contaminated areas by 140% but had the advantage of being completed in orders-of-magnitude fewer labor hours. Depending on project needs, the walk-over technique may be useful to include in tandem with flyover measurements to acquire maps with greater sensitivity and spatial resolution.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Mach Conference, 2022.

There has been considerable interest in chemical vapor infiltration (CVI) manufactured silicon carbide fiber and silicon carbide matrix (SiC/SiC) composite tubes due to their superior mechanical properties. The SiC/SiC tubes are known to remain stable even after prolonged exposure to radiation. However, there are many variables in the manufacturing of SiC/SiC composite tubes such as elastic constants of constituent SiC fiber and SiC matrix, braiding angle, porosity, and others whose values vary over a range. The intention is to identify the distribution of elastic constants of SiC/SiC tubes which would help model the performance of the novel cladding material. To do so, a sensitivity analysis will be carried out to determine the dominant variables that influence the elastic constants of SiC/SiC tubes. A chosen number of combinations of dominant variables will be sampled through the Latin hypercube sampling (LHS) method. The elastic constants of composite tube namely Young's moduli in the circumferential and longitudinal direction, Poisson's ratio, and shear modulus will be calculated at sampled points through finite element (FE) analysis. A polynomial response surface (PRS) will be built for each of the elastic constants to be used as a surrogate to FE analysis. Once the predictive accuracy of PRS is verified at the validation set of data points, the PRS will be invoked 105 times in Monte Carlo simulations (MCS). The uncertainty can be quantified by calculating the coefficient of variation (CV) based on MCS-generated data which will be presented at the conference.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

HEMODOSE: A Set of Multi-parameter Biodosimetry Tools

There continues to be important concerns of the possibility of the occurrence of acute radiation syndromes following nuclear and radiological terrorism or accidents that may result in mass casualties in densely populated areas. To guide medical personnel in their clinical decisions for effective medical management and treatment of the exposed individuals, biological markers are usually applied to examine radiation induced biological changes to assess the severity of radiation injury to sensitive organ systems. Among these the peripheral blood cell counts are widely used to assess the extent of radiation induced bone marrow (BM) injury. This is due to the fact that hematopoietic system is a vulnerable part of the human body to radiation damage. Particularly, the lymphocyte, granulocyte, and platelet cells are the most radiosensitive of the blood elements, and monitoring their changes after exposure is regarded as a practical and recommended laboratory test to estimate radiation dose and injury. In this work we describe the HEMODOSE web tools, which are built upon solid physiological and pathophysiological understanding of mammalian hematopoietic systems, and rigorous coarse-grained biomathematical modeling and validation. Using single or serial granulocyte, lymphocyte, leukocyte, or platelet counts after exposure, these tools can estimate absorbed doses of adult victims very rapidly and accurately to assess the severity of BM radiation injury. Some patient data from historical accidents are utilized as examples to demonstrate the capabilities of these tools as a rapid point-of-care diagnostic or centralized high-throughput assay system in a large-scale radiological disaster scenario. HEMODOSE web tools establish robust correlations between the absorbed doses and victim's various types of blood cell counts not only in the early time window (1 or 2 days), but also in very late phase (up to 4 weeks) after exposure.

Hu, Shaowen↗

Studies of charm quark diffusion inside jets using PbPb and pp collisions at $\sqrt{s_\mathrm{NN}} =$ 5.02 TeV

The first study of charm quark diffusion with respect to the jet axis in heavy ion collisions is presented. The measurement is performed using jets with $p^{jet}_T > 60 GeV / c$ and $D^0$ mesons with $p^D_T > 4 GeV / c$ in lead-lead (Pb-Pb) and proton-proton ($pp$) collisions at a nucleon-nucleon center-of-mass energy of $\sqrt{s_{NN}} = 5.02 TeV$, recorded by the CMS detector at the LHC. The radial distribution of $D^0$ mesons with respect to the jet axis is sensitive to the production mechanisms of the meson, as well as to the energy loss and diffusion processes undergone by its parent parton inside the strongly interacting medium produced in Pb-Pb collisions. When compared to Monte Carlo event generators, the radial distribution in $pp$ collisions is found to be well described by pythia, while the slope of the distribution predicted by sherpa is steeper than that of the data. In Pb-Pb collisions, compared to the $pp$ results, the $D^0$ meson distribution for $4 < p^D_T < 20 GeV / c$ hints at a larger distance on average with respect to the jet axis, reflecting a diffusion of charm quarks in the medium created in heavy ion collisions. At higher $p^D_T$, the Pb-Pb and $pp$ radial distributions are found to be similar.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

High sensitivity measurement of femtogram-level 238 Pu by thermal ionization mass spectrometry with correction of background 238 U

Low-concentration plutonium isotopic measurements provide a valuable fingerprint to identify possible material origins in the context of environmental contamination monitoring, environmental tracing, nuclear safeguards, nuclear forensics, and treaty monitoring. Thermal ionization mass spectrometry (TIMS) has long been recognized as one of the most sensitive techniques for plutonium isotopic measurement, but has not generally been utilized for 238 Pu determination, especially at low concentrations, due to an isobaric interference from 238 U, prevalent as background. Here, this work demonstrates a new analytical technique for correction of background 238 U from the 238 Pu counts collected during a TIMS analysis. The technique takes advantage of the higher ionization temperature of U relative to Pu and uses a 235 U tracer added after plutonium purification chemistry for 238 U semi-quantitative determination. This technique has been successfully applied to the determination of 238 Pu concentration and the 238 Pu/ 239 Pu ratio in sample types including single-isotope standards, isotopic certified reference materials, matrix-containing environmental reference materials, and simulated nuclear detonation debris. The results have been directly compared on a sample-by-sample basis to alpha spectrometry results. The detection limit by this new technique is 0.23 fg 238 Pu, which was previously unachievable by mass spectrometry and is possible in around 1 h of analysis time post-chemistry compared to weeks of required counting time by alpha spectrometry (at the same atom amount). We also present original, high precision data for Pu isotope concentrations in IAEA-384, Fangataufa Sediment, including 242 Pu results for the first time. The new technique allows measurement of a key isotope, 238 Pu, that was previously not measured in small environmental or nuclear forensics collections.

238Pu↗

GCR Environmental Models I: Sensitivity Analysis for GCR Environments

Accurate galactic cosmic ray (GCR) models are required to assess crew exposure during long-duration missions to the Moon or Mars. Many of these models have been developed and compared to available measurements, with uncertainty estimates usually stated to be less than 15%. However, when the models are evaluated over a common epoch and propagated through to effective dose, relative differences exceeding 50% are observed. This indicates that the metrics used to communicate GCR model uncertainty can be better tied to exposure quantities of interest for shielding applications. This is the first of three papers focused on addressing this need. In this work, the focus is on quantifying the extent to which each GCR ion and energy group, prior to entering any shielding material or body tissue, contributes to effective dose behind shielding. Results can be used to more accurately calibrate model-free parameters and provide a mechanism for refocusing validation efforts on measurements taken over important energy regions. Results can also be used as references to guide future nuclear cross-section measurements and radiobiology experiments. It is found that GCR with Z>2 and boundary energies below 500 MeV/n induce less than 5% of the total effective dose behind shielding. This finding is important given that most of the GCR models are developed and validated against Advanced Composition Explorer/Cosmic Ray Isotope Spectrometer (ACE/CRIS) measurements taken below 500 MeV/n. It is therefore possible for two models to very accurately reproduce the ACE/CRIS data while inducing very different effective dose values behind shielding.

Slaba, Tony C.↗

Experimental Validation of Thermal Scattering Evaluations

In order to test the performance of new neutron thermal scattering law (TSL) evaluations it is desirable to have experimental data that is highly sensitive to the TSL and provides high fidelity information on the energy dependent performance of TSL evaluations. Three relevant experiments are discussed including: accurate thermal total cross section measurements, thermal neutron die-away experiments, and neutron leakage experiments. The experimental setups and results are reviewed, and examples provided for some moderators including polyethylene, Plexiglas, and YHx. For the experiments preformed thus far, there is generally good agreement between the measured total cross section and simulations using current TSL evaluations, however in certain energy ranges differences were observed. Similarly, neutron die-away and leakage measurements for samples at room temperature are in good agreement with data computed from TSLs, however leakage measurements for polyethylene at 29K show discrepancies with TSL evaluations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Total absorption spectroscopy for the 𝛽 + decay strength distribution of 60 Ga

𝛽-decay properties play an important role in most astrophysical processes. In the absence of experimental data, astrophysical models rely on global theoretical calculations to provide the relevant properties. It is therefore important to provide strong experimental constraints when possible. In the case of 𝛽-decay, the most sensitive probe is the 𝛽-decay strength distribution. We report here on the first measurement of the latter quantity for the 𝛽 + decay of 60 Ga using the total absorption spectroscopy technique. The experimental results are compared to theoretical calculations often used in astrophysical models, namely the shell model and the quasiparticle random phase approximation (QRPA), as well as an extension of QRPA that includes higher-order nucleonic calculations. Both models are in reasonable agreement with the experimental results.

59 ≤ A ≤ 89↗

Experimental search for the chiral magnetic effect in relativistic heavy-ion collisions: A perspective

The chiral magnetic effect (CME) refers to generation of the electric current along a magnetic field in a chirally imbalanced system of quarks. The latter is predicted by quantum chromodynamics to arise from quark interaction with nontrivial topological fluctuations of the vacuum gluonic field. The CME has been actively searched for in relativistic heavy-ion collisions, where such gluonic field fluctuations and a strong magnetic field are believed to be present. The CME-sensitive observables are unfortunately subject to a possibly large non-CME background, and firm conclusions on a CME observation have not yet been reached. In this perspective, we review the experimental status and progress in the CME search, from the initial measurements more than a decade ago to the dedicated program of isobar collisions in 2018 and the release of the isobar blind analysis result in 2022 to intriguing hints of a possible CME signal in Au + Au collisions, and discuss future prospects of a potential CME discovery in the anticipated high-statistic Au + Au collision data at the Relativistic Heavy-Ion Collider by 2025. We hope such a perspective will help sharpening our focus on the fundamental physics of the CME and steer its experimental search.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Chemical Mapping of Vesta

Vesta s surface mineralogy and composition have been studied for decades via telescopic spectroscopy and laboratory analyses of the howardite, eucrite, and diogenite (HED) meteorites, which are thought to originate from Vesta. Visible and infrared reflectance measurements by Dawn have broadly confirmed the paradigm established by Earth-based work, strengthening the Vesta-HED connection. The Dawn mission has achieved a milestone by completing the first chemical measurements of a main-belt asteroid using nuclear spectroscopy. Dawn s Gamma Ray and Neutron Detector (GRaND) has globally mapped the composition of Vesta, including the portions of the northern hemisphere not illuminated by solar radiation. GRaND is sensitive to the composition of the bulk regolith to depths of several decimeters. Abundances and/or detection limits for specific elements and elemental ratios, such as H, Fe, Si, Fe/O, Fe/Si, and K, have been measured. Variations in the average atomic mass and neutron macroscopic absorption cross section have been characterized. The measurements constrain the relative proportions of HED whole-rock end-members, providing measurements of the pyroxene and plagioclase content of the regolith, thereby constraining the processes underlying Vesta s differentiation and crustal evolution. The spatial resolution of GRaND is sufficient to determine basin-average compositions of Veneneia and Rheasilvia, which may contain outcrops of Vesta s olivine-rich mantle. While the elemental composition of Vesta s regolith is similar to the meteorites, there are notable departures from HED whole-rock compositions. While these differences are not sufficient to topple the Vesta-HED paradigm, they provide insight into global-scale processes that have shaped Vesta s surface. Questions addressed by the analysis of GRaND data include: (i) Is Vesta the source of the Fe-rich mesosiderites? (ii) Are evolved, igneous lithologies present on Vesta s surface? (iii) What are the origins of exogenic materials found in Vesta s regolith? (iv) Is the vestan mantle exposed within the southern basins?

Prettyman, Thomas H.↗

A Multiple Parameters Biodosimetry Tool with Various Blood Cell Counts - the Hemodose Approach

There continue to be important concerns about the possibility of the occurrence of acute radiation syndromes following nuclear and radiological terrorism or accidents that may result in mass casualties in densely populated areas. To guide medical personnel in their clinical decisions for effective medical management and treatment of the exposed individuals, biological markers are usually applied to examine radiation induced biological changes to assess the severity of radiation injury to sensitive organ systems. Among these the peripheral blood cell counts are widely used to assess the extent of radiation induced bone marrow injury. This is due to the fact that the hematopoietic system is the most vulnerable part of the human body to radiation damage. Particularly, the lymphocyte, granulocyte, and platelet cells are the most radiosensitive of the blood elements, and monitoring their changes after exposure is regarded as a practical and recommended laboratory test to estimate radiation dose and injury. Based upon years of physiological and pathophysiological investigation of mammalian hematopoietic systems, and rigorous coarse-grained bio-mathematical modeling and validation on species from mouse, to dog, monkey, and human, we have developed a set of software tools Hemodose, which can use single or serial granulocyte, lymphocyte, leukocyte, or platelet counts after exposure to estimate absorbed doses of adult victims very rapidly and accurately. Some patient data from historical accidents are utilized as examples to demonstrate the capabilities of these tools as a rapid point-of-care diagnostic or centralized high-throughput assay system in a large-scale radiological disaster scenario. Most significant to the improvement of national and local preparedness of a potential nuclear/radiological disaster, this HemoDose approach establishes robust correlations between the absorbed doses and victim's various types of blood cell counts not only in the early time window (1 or 2 days), but also in the very late phase (up to 4 weeks) after exposure.

Hu, Shaowen↗

Testing meson portal dark sector solutions to the MiniBooNE anomaly at the Coherent CAPTAIN Mills experiment

A solution to the MiniBooNE excess invoking rare three-body decays of the charged pions and kaons to new states in the MeV mass scale was recently proposed as a dark-sector explanation. This class of solution illuminates the fact that, while the charged pions were focused in the target-mode run, their decay products were isotropically suppressed in the beam-dump-mode run in which no excess was observed. This suggests a new physics solution correlated to the mesonic sector. We investigate an extended set of phenomenological models that can explain the MiniBooNE excess as a dark sector solution, utilizing long-lived particles that might be produced in the three-body decays of the charged mesons and the two-body anomalous decays of the neutral mesons. Over a broad set of interactions with the long-lived particles, we show that these scenarios can be compatible with constraints from LSND, KARMEN, and MicroBooNE, and evaluate the sensitivity of the ongoing and future data taken by the Coherent CAPTAIN Mills experiment to a potential discovery in this parameter space. Published by the American Physical Society 2024

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Evaluating Safeguards Statistical Assumptions via Stochastic Simulation

Herein, the authors built and tested a stochastic simulation to estimate achieved detection probabilities (DPs) on a stratum basis, over a tailorable range of diverted amounts from 0 to 2 SQ, using typical IAEA inspection data: i.e., SQ in stratum, number of items, number of gross/partial/bias defect measurements conducted, and realistic relative standard deviation (RSD) values for typical IAEA verification measurements. For bulk strata, the model calculates achieved DP at 0.01 SQ diversion increments; for item strata, the model calculates DP using the smallest realistic diversion increment (e.g., a plate, pin, or coupon). After successfully benchmarking against IAEA deterministic models, the simulation was used to test the sensitivity of DP to certain standard assumptions and selected input parameters. First, the equal defect assumption was tested; the results suggest significant complexity in the effectiveness of partial defect measurements. Next, the authors explored the sensitivity of DP to the assumed RSD of attribute tests. Then, the authors compared non-normal models for instrument performance (e.g., logistic, step, or arbitrary functions) to the typical results from a normal distribution (characterized by RSD). This last comparison was supplemented with experimentally derived performance data for an HM-5. The HM-5 was used to make enrichment measurements on both LEU and HEU MTR fuel elements as plates were removed, and the results fit with logistic and step curves and applied in the simulation. These stochastic DP results were compared to DP estimates from a deterministic model assuming a normal curve and typical RSD, yielding insights that could improve effectiveness in the field. These early results illustrate the potential of stochastic models to better understand achieved DP and to improve safeguards effectiveness.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Development of a Photoacoustic Formaldehyde Monitor

Key indoor air quality pollutant formaldehyde (H 2 CO) is tracked on International Space Station (ISS) using passive badges returned to the ground periodically for analysis. The process is time-consuming both in preparation and for analysis upon return 6-12 months later. Badges also require precious crew time for deploy, retrieval and stow. As NASA’s focus in space exploration shifts to the Moon and Mars, archival sample return becomes increasingly impractical, so the aim of this project is to develop a highly reliable real-time analyzer for H 2 CO at low concentrations with data downlinked. Potential sources of H 2 CO include materials off gassing, use of formalin as a tissue fixative in biological payloads and overheating of acetal polymers. The Spacecraft Maximum Allowable Concentration (SMAC) for H 2 CO in air is 100 ppb for exposures of 7 days or longer. ISS concentrations of H 2 CO are running only 10 - 30 ppb in the recent several years but have spiked as high as 60 ppb. Gateway real time monitoring requirements for H 2 CO call for a range of 8 - 138 ppb. For this project, a concentration range of 5 - 500 ppb H 2 CO is targeted. The core tunable diode laser spectroscopy (TDLS) technology used for this project was developed by Vista Photonics through the NASA and US Navy Small Business Innovation Research (SBIR) programs. Monitors based on TDLS have been demonstrated on ISS, trialed on a nuclear submarine and are being certified as portable Anomaly Gas Analyzers (AGA) for both ISS and Orion. Initially, direct absorption TDLS was used exclusively in these devices. The H 2 CO target concentration, however, is low ppb, and a longer wavelength is required, so a photoacoustic spectroscopy (PAS) technique was adapted, where the laser excitation is detected by a sensitive microphone vs. a conventional photodetector. This paper will discuss the results of NASA-JSC laboratory testing of a prototype PAS based formaldehyde in air monitor and briefly discuss next steps.

Photoacoustic Formaldehyde Monitor↗

Ultra-sensitive radon assay using an electrostatic chamber in a recirculating system

Rare event searches such as neutrinoless double beta decay and Weakly Interacting Massive Particle detection require ultra-low background detectors. Radon contamination is a significant challenge for these experiments, which employ highly sensitive radon assay techniques to identify and select low-emission materials. This work presents the development of ultra-sensitive electrostatic chamber (ESC) instruments designed to measure radon emanation in a recirculating gas loop, for future lower background experiments. Unlike traditional methods that separate emanation and detection steps, this system allows continuous radon transport and detection. This is made possible with a custom-built recirculation pump. A Python-based analysis framework, PyDAn, was developed to process and fit time-dependent radon decay data. Radon emanation rates are given for various materials measured with this instrument. A radon source of known activity provides an absolute calibration, enabling statistically-limited minimal detectable activities of 20 uBq. These devices are powerful tools for screening materials in the development of low-background particle physics experiments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗