Active Inspection of Nuclear Materials Using {sup 4}He Scintillation Detectors

The detection of fissionable materials by neutron and high-energy photon active interrogation methods is explored using {sup 4}He scintillation detectors to search for prompt and delayed neutron signature. The low electron density of {sup 4}He in addition to its pulse shape discrimination capability allows strong rejection of gamma radiation. For the detection of the prompt neutron signatures, this capability is important as the signal produced by induced fission is accompanied by intense gamma radiation. The nanosecond time resolution of {sup 4}He scintillation detectors can be used for time-of-flight measurements aimed at determining the energy of the emitted neutrons. For delayed neutron detection, the insensitivity to the low energy neutrons present from non-signal reactions is inherent. Unlike detectors requiring a moderator, this technology can easily be collimated to reduce sensitivity to neutrons from outside the field of interest. The performance of the detectors for these applications is studied using GEANT4 computer modeling, based on measured detector parameters. A comparison is made with technologies typically used for these applications, i.e. heavily shielded organic scintillators for prompt neutron detection and Cd-lined {sup 3}He neutron detectors for the detection of delayed neutrons.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

System and method for fissionable material detection with a short pulse neutron source

A system and method is disclosed for detecting fissionable materials. In one embodiment the system may incorporate a neutron pulse generator configured to generate multiple short pulses of neutrons, or a single pulse of sufficient intensity, in a vicinity of an object of interest. The source pulse of neutrons includes neutrons which each have a full width half maximum time duration of less than about 100 ns and a peak energy level no greater than about 20 MeV. A fast response detector is used which is able to detect single neutron events indicative of fission neutrons having been produced by the source pulse of neutrons interacting with fissionable material associated with the object of interest, and which arrive at the fast response detector within a predetermined time window immediately before arrival of the source neutron pulses.

Podpaly, Yuri↗

Absolute measurements of fast neutrons using yttrium

Yttrium is presented as an absolute neutron detector for pulsed neutron sources. It has high sensitivity for detecting fast neutrons. Yttrium has the property of generating a monoenergetic secondary radiation in the form of a 909 keV gamma-ray caused by inelastic neutron interaction. It was calibrated numerically using MCNPX and does not need periodic recalibration. The total yttrium efficiency for detecting 2.45 MeV neutrons was determined to be f{sub n}{approx}4.1x10{sup -4} with an uncertainty of about 0.27%. The yttrium detector was employed in the NX2 plasma focus experiments and showed the neutron yield of the order of 10{sup 8} neutrons per discharge.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Neutron counting with cameras

A research project is presented in which we aim at counting individual neutrons with CCD-like cameras. We explore theoretically a technique that allows us to use imaging detectors as counting detectors at lower counting rates, and transits smoothly to continuous imaging at higher counting rates. As such, the hope is to combine the good background rejection properties of standard neutron counting detectors with the absence of dead time of integrating neutron imaging cameras as well as their very good spatial resolution. Compared to Xray detection, the essence of thermal neutron detection is the nuclear conversion reaction. The released energies involved are of the order of a few MeV, while X-ray detection releases energies of the order of the photon energy, which is in the 10 KeV range. Thanks to advances in camera technology which have resulted in increased quantum efficiency, lower noise, as well as increased frame rate up to 100 fps for CMOS-type cameras, this more than 100-fold higher available detection energy implies that the individual neutron detection light signal can be significantly above the noise level, as such allowing for discrimination and individual counting, which is hard to achieve with X-rays. The time scale of CMOS-type cameras doesn't allow one to consider time-of-flight measurements, but kinetic experiments in the 10 ms range are possible. The theory is next confronted to the first experimental results. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

RADIO DETECTION OF A CANDIDATE NEUTRON STAR ASSOCIATED WITH GALACTIC CENTER SUPERNOVA REMNANT SAGITTARIUS A EAST

We report the Very Large Array (VLA) detection of the radio counterpart of the X-ray object referred to as the 'Cannonball', which has been proposed to be the remnant neutron star resulting from the creation of the Galactic center supernova remnant, Sagittarius A East. The radio object was detected both in our new VLA image from observations in 2012 at 5.5 GHz and in archival VLA images from observations in 1987 at 4.75 GHz and in the period from 1990 to 2002 at 8.31 GHz. The radio morphology of this object is characterized as a compact, partially resolved point source located at the northern tip of a radio 'tongue' similar to the X-ray structure observed by Chandra. Behind the Cannonball, a radio counterpart to the X-ray plume is observed. This object consists of a broad radio plume with a size of 30''×15'', followed by a linear tail having a length of 30''. The compact head and broad plume sources appear to have relatively flat spectra (∝ν{sup α}) with mean values of α = –0.44 ± 0.08 and –0.10 ± 0.02, respectively, and the linear tail shows a steep spectrum with the mean value of –1.94 ± 0.05. The total radio luminosity integrated from these components is ∼8 × 10{sup 33} erg s{sup –1}, while the emission from the head and tongue amounts for only ∼1.5 × 10{sup 31} erg s{sup –1}. Based on the images obtained from the two epochs' observations at 5 GHz, we infer the proper motion of the object: μ{sub α} = 0.001 ± 0.003 arcsec yr{sup –1} and μ{sub δ} = 0.013 ± 0.003 arcsec yr{sup –1}. With an implied velocity of 500 km s{sup –1}, a plausible model can be constructed in which a runaway neutron star surrounded by a pulsar wind nebula was created in the event that produced Sgr A East. The inferred age of this object, assuming that its origin coincides with the center of Sgr A East, is approximately 9000 yr.

79 ASTRONOMY AND ASTROPHYSICS↗

Detection of entrapped moisture in honeycomb sandwich structures

Thermal neutron moisture detection system detects entrapped moisture in intercellular areas of bonded honeycomb sandwich structures. A radium/beryllium fast neutron source bombards a specimen. The emitted thermal neutrons from the target nucleus are detected and counted by a boron trifluoride thermal neutron detector.

Hallmark, W. B.↗

Nuclear proton and neutron distributions in the detection of weak interacting massive particles

In the evaluation of weak interacting massive particles (WIMPs) detection rates, the WIMP-nucleus cross section is commonly described by using form factors extracted from charge distributions. In this work, we use different proton and neutron distributions taken from Hartree-Fock calculations. We study the effects of this choice on the total detection rates for six nuclei having different neutron excess, and taken from different regions of the nuclear chart. The use of different distributions for protons and neutrons becomes more important if isospin-dependent WIMP-nucleon interactions are considered. The need for distinct descriptions of proton and neutron densities decreases with the lowering of detection energy thresholds.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Solid, structured composite neutron detectors with high dynamic range capability

Neutron detectors are essential across disciplines such as fundamental science, nuclear security, safeguards, and civilian applications. While 3 He-filled gas proportional counters have long been revered for their efficacy in detecting thermal neutrons and praised for their efficiency, neutron/gamma discrimination, and stability, the scarcity of 3He has spurred a search for alternatives. Here, we explore a solid structured scintillating particle composite (SPC) consisting of 6 Li-containing scintillating glass particles within an acrylic matrix as a neutron detector for high dynamic range applications. We show for the first time that an SPC neutron detector can boast an intrinsic detection efficiency of 0.261% for pure 252 Cf fission neutrons and an overall neutron detection efficiency of (0.546 ± 0.003)% at the Neutron Free-in-Air facility while being able to function in an intense gamma-ray environment. We also show that the SPC neutron detector supports fast neutron capture times and enables a dual-readout scheme that extends the detector dynamic range to high incident neutron fluxes. A scalable fabrication process allows for tailoring the SPC detector properties to the requirements of specific applications. Good agreement is found between the experimental results taken with a National Institute of Standards and Technology traceable 252 Cf source and the coupled MCNP6 and optical-ray-tracing simulations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High-precision characterization of the neutron light output of stilbene along the directions of maximum and minimum response

The scintillation light output response of stilbene crystals has been calculated for protons recoiling along the a, b, and c' crystalline axes with energies between 1.3 and 10 MeV using neutrons produced with the tandem Van de Graaff accelerator at Triangle Universities Nuclear Laboratory. The proton recoil energy and direction were measured using the coincident detection of neutrons between a stilbene scintillator and an array of EJ-309 liquid scintillators spanning arranged neutron recoil angles. The maximum light output was discovered to coincide with proton recoils along the a-axis, in disagreement with other published measurements, which reported the b-axis as the direction of the maximum light output. Additional measurements were conducted using two different stilbene crystals to confirm these results: a second measurement using the coincident detection of neutrons; measurements of neutron full energy deposition events along the a and b axes; and measurements of the count rate for 252 Cf neutrons traveling along the a and b axes directions. All measurements found that recoils along the a-axis produce the maximum light output.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

ADVANTG Results for a Proposed NDA System for Detecting Pin Diversion from SNF - Paper 120

This summary describes the results of applying the ADVANTG variance reduction parameter generator to accelerate continuous-energy Monte Carlo simulations of the {sup 252}Cf Interrogation with Prompt Neutron (CIPN) detection system proposed by Hu et al. for detecting the diversion of fuel elements from spent nuclear fuel (SNF) assemblies. In previous work, ADVANTG was applied to a suite of nine radiation detection, special nuclear material (SNM) movement detection, and safeguards test cases. That effort demonstrated that ADVANTG was able to provide large increases in tally figures of merit (FOMs) in nearly all of the cases without introducing bias into the Monte Carlo results. The objective of the work described here is to further evaluate ADVANTG, and also to identify gaps in capability with regard to nuclear safeguards applications, by applying the code to a challenging problem that is of a different nature from the ones previously studied. The CIPN nondestructive assay (NDA) system consists of three fission chambers embedded in a C-shaped block of polyethylene and a polyethylene-moderated {sup 252}Cf source that are placed on opposite sides of a subject SNF assembly. The idea of the detection system is to measure the difference between the background neutron count rate, due to spontaneous fission in the fuel material, and the count rate observed once the source is introduced, which is dominated by multiplication within the assembly. Based on the difference between these count rates, the fissile content of the assembly can be inferred, and this information can be used to determine if some fraction of the original fuel pins have been replaced with depleted uranium substitutes. The authors report that the system can detect the replacement of at least eight pins (3% of total mass). The ADVANTG code generates space- and energy-dependent weight-window bounds and biased source distributions based on approximate transport solutions that are efficiently generated by the Denovo 3-D discrete ordinates package. ADVANTG implements the Consistent Adjoint Driven Importance Sampling (CADIS) method for accelerating individual tallies and the Forward-Weighted CADIS (FW-CADIS) method for obtaining relatively uniform uncertainties across tallies over multiple regions and/or energy bins. The variance reduction parameters are generated in a format directly usable by standard versions of MCNP5 and MCNPX. In this work, the ADVANTG variance reduction parameter generator was applied to accelerate continuous energy MCNPX simulations of the {sup 252}Cf Interrogation with Prompt Neutron detection system for detecting the diversion of fuel elements from SNF assemblies. Variance reduction parameters generated with the existing version of ADVANTG actually slowed down tally convergence in all cases. The cause of the poor performance was found to be the lack of an induced fission source treatment in the fixed-source discrete ordinates calculations employed by ADVANTG. Because fission was treated as capture and not as a source, the importance maps generated by ADVANTG significantly underestimated the importance of thermal neutrons in and around the fuel elements. In order to obtain improved results, we developed an experimental implementation of a fission source outer iteration for the adjoint calculations. We used this prototype capability to generate new variance reduction parameters and found that the mean fission rates agreed well with those predicted by the conventional MCNPX simulations, as was expected. With these new parameters, speedup factors of 59 to 80 were obtained for the case with the background source, and factors of 17 to 24 were obtained for the cases with the interrogating source. These results demonstrate that a fission source treatment is needed to improve the effectiveness of ADVANTG in problems where the effects of induced fission are important. This includes many types of NDA problems that are relevant to safeguards applications. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Scintillation Hydro-Gel for Isotopic Neutron (SHINE): Eco-Friendly Quantum Dot Neutron Detectors

The development of new neutron detectors to replace helium-3 (3He) detectors is imperative due to a worldwide shortage of 3He following the draw down in nuclear weapons production since the end of the Cold War. The United States Department of Homeland Security would like to deploy monitors for the detection of neutron emissions from shipping containers housing illicit nuclear material; however, this effort has been put on hold until new replacements for 3He detectors can be developed. Scintillation Hydro-Gel for isotopic Neutron Emitters (SHINE) is a unique, first of its kind, 6Li-loaded quantum dot gel scintillator developed at INL. By incorporating 6Li with quantum dots in a gel matrix, SHINE displays the best properties of liquid and solid scintillators without their disadvantages such as continuous filtering to keep liquids free of contaminates, slow throughput of containers, higher base component costs, ‘dead’ voids in solid scintillators, and a high loading of 6Li without compromising on light transparency. Additionally, SHINE is completely eco-friendly, a breakthrough in high-efficiency detection systems. SHINE is a unique combination of 6LiCl, a highly water-soluble compound, and InP/ZnS core/shell quantum dots, which are poured into a gel-form using cross-linking polymers. In this presentation, SHINE has been successfully tested for neutron detection and shows promise as both a replacement for current 3He neutron detectors as well as potential use in handheld, compact neutron detection units and antineutrino detection.

36 MATERIALS SCIENCE↗

Correlated fission data measurements with DANCE and NEUANCE

To enhance the capabilities of the DANCE array, a new detector array NEUANCE was developed to enable simultaneous measurements of prompt fission neutrons and γ rays. NEUANCE was designed and constructed using 21 stilbene organic scintillator crystals. It was installed in the central cavity of the DANCE array. Signals from the 160 BaF 2 detectors of DANCE and the 21 detectors of NEUANCE were merged into a newly designed high-density high-throughput data acquisition system. The excellent pulse shape discrimination properties of stilbene enabled detection of neutrons with energy thresholds as low as 30–40 keVee. A fission reaction tagging method was developed using a NEUANCE γ-ray or neutron signal. The probability of detecting a neutron from the spontaneous fission of 252 Cf using NEUANCE is 47%. New correlated data for prompt fission neutrons and prompt fission rays were obtained for 252 Cf using this high detection efficiency experimental setup. In conclusion, average properties of prompt fission neutron emission as a function of prompt fission γ-ray quantities were also obtained, suggesting that neutron and γ-ray emission in fission are correlated.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Neutron Based Scanner to Detect Explosives in Small, Sealed Containers

A scanning system has been designed for portal protection applications, with the capability of detecting explosive materials after an initial scan of 30 seconds. The scanner operates using the principle of neutron induced return gamma-ray spectrometry. This system utilizes high purity germanium detectors, a neutron generator based on deuterium-tritium fusion and a unique neutron reflector and guide design. The neutron reflector amplifies the flux and alters the energy spectrum of neutrons produced by the generator. A depleted uranium reflector is shown to perform 7.3 times better than no reflector, and is found to perform 1.5 times better than a tungsten reflector using MCNP simulation. This improvement is due to neutron knockout and induced fission occurring in depleted uranium. The system is capable of detecting 300 g of explosives with 90% detection probability, which includes a 15% rescan rate after a 30 second initial scan.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The Electromagnetic Counterpart of the Binary Neutron Star Merger LIGO/Virgo GW170817. IV. Detection of Near-infrared Signatures of r -process Nucleosynthesis with Gemini-South

We present a near-infrared spectral sequence of the electromagnetic counterpart to the binary neutron star merger GW170817 detected by Advanced Laser Interferometer Gravitational-wave Observatory (LIGO)/Virgo. Our data set comprises seven epochs of J + H spectra taken with FLAMINGOS-2 on Gemini-South between 1.5 and 10.5 days after the merger. In the initial epoch, the spectrum is dominated by a smooth blue continuum due to a high-velocity, lanthanide-poor blue kilonova component. Starting the following night, all of the subsequent spectra instead show features that are similar to those predicted in model spectra of material with a high concentration of lanthanides, including spectral peaks near 1.07 and 1.55 μ m. Our fiducial model with 0.04 M {sub ⊙} of ejecta, an ejection velocity of v = 0.1 c , and a lanthanide concentration of X {sub lan} = 10{sup −2} provides a good match to the spectra taken in the first five days, although it over-predicts the late-time fluxes. We also explore models with multiple fitting components, in each case finding that a significant abundance of lanthanide elements is necessary to match the broad spectral peaks that we observe starting at 2.5 days after the merger. These data provide direct evidence that binary neutron star mergers are significant production sites of even the heaviest r -process elements.

79 ASTRONOMY AND ASTROPHYSICS↗

Lunar Reconnaissance Orbiter (LRO) Observations with the Lunar Exploration Neutron Detector (LEND): Neutron Suppression Regions (NSR) and Polar Hydrogen

Orbital detection of neutrons has become the dominant remote sensing technique for detecting and inferring H concentrations and its spatial distribution beneath planetary surfaces [Lawrence et al, (2010) Icarus, 205, pp. 195-209, Mitrofanov et al (2007) Science 297(5578), 78-81]. Indications for the presence of localized and relatively high water content was provided by LRO and LCROSS. LEND identified Cabeus, as the most promising LCROSS impact site [Mitrofanov I. et al. (2010) Science, 330, 483], and instruments onboard LRO and LCROSS have measured signatures of water, H2 and other volatiles in the impact plume [Colaprete A. et al. (2010) Science, 339,463, Gladstone R. et al. (2010) Science, 330, 472].

Chin, G.↗

Fast-Neutron Multiplicity Counter for the Detection of Diversion Scenarios

We demonstrated the application of a fast-neutron multiplicity counter (FNMC) to detect small variations in an assembly of uranium-oxide pins. The current version of the FNMC includes eight liquid organic scintillators (EJ-309 7.62 cm diameter x 7.62 cm) and eight crystal organic scintillators (stilbene 5.08 cm diameter x 5.08 cm) in a checkerboard assembly. We measured time-correlated fast neutrons, emitted by an assembly of 32 uranium-oxide pins, using two AmLi sources to induce fissions in the sample. Each pin is a cylinder of approximately 1 cm diameter and 10 cm length, with a mass of 75.52 g and 16.37 wt% enrichment. We removed up to 16 pins from a sample consisting of 32 pins, and determined the minimum number of pins that resulted in a statistically significant decrease of neutron coincidence counts. All the measurements were performed at the Zero Power Physics Reactor facility of Idaho National Laboratory. We found that a diversion of the four innermost pins could be detected by the system in 5 minutes. The detection of time-correlated neutrons requires their discrimination from gamma-ray events. This is an especially challenging task when measuring uranium isotopes, because of the intense gamma-ray flux generated by the radioactive decay of uranium daughters. We will describe the on-board pulse shape discrimination and post processing techniques that we applied to effectively distinguish neutrons from gamma-rays. Fast-neutron measurements have several potential advantages compared to thermal and epithermal neutron counters, the most important being a shorter die-away time and therefore reduced spurious coincidences due to accidental counts. This advantage may result in a higher sensitivity in timely detecting diversion of nuclear material from peaceful uses.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗