1D-Convolutional Neural Network Architecture for Generalized Time-Segmentation Tasks

Time segmentation of experimental data is a common and often difficult task. Consequently, it is of interest to automate this type of segmentation to reduce manual inputs, which are labor intensive and less consistent. However, simple thresholding algorithms are often insufficiently robust due either to noise or inconsistent data. This paper proposes a simple 1D CNN architecture as a generalized solution for typical time segmentation tasks. The layer architecture, training methods, and methods for simple customization are described as well as the results of application to three separate arc jet data streams: facility condition segmentation, video highlight segmentation, and calorimeter time-series segmentation.

Machine learning↗

1d-Convolutional Neural Network Architecture for Generalized Time-Segmentation Tasks

Time segmentation of experimental data is a common and often difficult task. Consequently, it is of interest to automate this type of segmentation to reduce manual inputs, which are labor intensive and less consistent. However, simple thresholding algorithms are often insufficiently robust due either to noise or inconsistent data. This paper proposes a simple 1D CNN architecture as a generalized solution for typical time segmentation tasks. The layer architecture, training methods, and methods for simple customization are described as well as the results of application to three separate arc jet data streams: facility condition segmentation, video highlight segmentation, and calorimeter time-series segmentation.

Machine learning↗

1D-Convolutional Neural Network Architecture for Generalized Time-Segmentation Tasks

Time segmentation of experimental data is a common and often difficult task. Consequently, it is of interest to automate this type of segmentation to reduce manual inputs, which are labor intensive and less consistent. However, simple thresholding algorithms are often insufficiently robust due either to noise or inconsistent data. This paper proposes a simple 1D convolutional neural net (CNN) architecture as a generalized solution for typical time segmentation tasks. The layer architecture, training methods, and methods for simple customization are described as well as the results of application to three separate arc jet data streams: facility condition segmentation, video highlight segmentation, and calorimeter time-series segmentation.

Machine learning↗

1D-Convolutional Neural Network Architecture for Generalized Time-series Segmentation

Time segmentation of experimental data is a common and often difficult task. Consequently, it is of interest to automate this type of segmentation to reduce manual inputs, which are labor intensive and less consistent. However, simple thresholding algorithms are often insufficiently robust due either to noise or inconsistent data. This paper proposes a simple 1D convolutional neural net (CNN) architecture as a generalized solution for typical time segmentation tasks. The layer architecture, training methods, and methods for simple customization will be described as well as the results of application to three separate data streams: facility condition segmentation, video highlight segmentation, and calorimeter time-series segmentation. In all three test cases the 1D-CNN performs better than tailored integral/derivative/thresholding algorithms across a range of signal-to-noise levels.

CNN↗

1D-Convolutional Neural Network Architecture for Generalized Time-series Segmentation

Time segmentation of experimental data is a common and often difficult task. Consequently, it is of interest to automate this type of segmentation to reduce manual inputs, which are labor intensive and less consistent. However, simple thresholding algorithms are often insufficiently robust due either to noise or inconsistent data. This paper proposes a simple 1D convolutional neural net (CNN) architecture as a generalized solution for typical time segmentation tasks. The layer architecture, training methods, and methods for simple customization will be described as well as the results of application to three separate data streams: facility condition segmentation, video highlight segmentation, and calorimeter time-series segmentation. In all three test cases the 1D-CNN performs better than tailored integral/derivative/thresholding algorithms across a range of signal-to-noise levels.

CNN↗

The high dynamic range pixel array detector (HDR-PAD): Concept and design

Experiments at storage ring light sources as well as at next-generation light sources increasingly require detectors capable of high dynamic range operation, combining low-noise detection of single photons with large pixel well depth. XFEL sources in particular provide pulse intensities sufficiently high that a purely photon-counting approach is impractical. The High Dynamic Range Pixel Array Detector (HDR-PAD) project aims to provide a dynamic range extending from single-photon sensitivity to 10{sup 6} photons/pixel in a single XFEL pulse while maintaining the ability to tolerate a sustained flux of 10{sup 11} ph/s/pixel at a storage ring source. Achieving these goals involves the development of fast pixel front-end electronics as well as, in the XFEL case, leveraging the delayed charge collection due to plasma effects in the sensor. A first prototype of essential electronic components of the HDR-PAD readout ASIC, exploring different options for the pixel front-end, has been fabricated. Here, the HDR-PAD concept and preliminary design will be described.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Reduction of rotor-turbulence interaction noise in static fan noise testing

Three effective inlet cleanup methods are described. A flared reverse cone inlet is used to eliminate wakes from the fan casings and/or probe supports. Boundary layer suction is employed ahead of the fan rotor and on the outer flare of the cone to reduce the boundary layer turbulence and remove any residual wakes. To reduce the midstream turbulent intensity and length scales, a turbulence control structure is used which is constructed with both a layer of honeycomb and a fine mesh screen. The effects of these cleanup methods are quantified by measuring the far-field noise in an anechoic chamber, using a high-speed 20-in.-diam fan of the current high passband type. The changes in the turbulent field impinging on this rotor are quantified by mapping the streamwise and transverse turbulent properties (spectra, intensity and length scale) with crossed hot film probes. It is convincingly shown that it is possible to clean up the inlet flow of a static fan noise test facility to a point where the static acoustic data simulate flight data.

Kantola, R. A.↗

NASA Glenn's Acoustical Testing Laboratory Awarded Accreditation by the National Voluntary Laboratory Accreditation Program

NASA Glenn Research Center's Acoustical Testing Laboratory (ATL) provides a comprehensive array of acoustical testing services, including sound pressure level, sound intensity level, and sound-power-level testing per International Standards Organization (ISO)1 3744. Since its establishment in September 2000, the ATL has provided acoustic emission testing and noise control services for a variety of customers, particularly microgravity space flight hardware that must meet International Space Station acoustic emission requirements. The ATL consists of a 23- by 27- by 20-ft (height) convertible hemi/anechoic test chamber and a separate sound-attenuating test support enclosure. The ATL employs a personal-computer-based data acquisition system that provides up to 26 channels of simultaneous data acquisition with real-time analysis (ref. 4). Specialized diagnostic tools, including a scanning sound-intensity system, allow the ATL's technical staff to support its clients' aggressive low-noise design efforts to meet the space station's acoustic emission requirement. From its inception, the ATL has pursued the goal of developing a comprehensive ISO 17025-compliant quality program that would incorporate Glenn's existing ISO 9000 quality system policies as well as ATL-specific technical policies and procedures. In March 2003, the ATL quality program was awarded accreditation by the National Voluntary Laboratory Accreditation Program (NVLAP) for sound-power-level testing in accordance with ISO 3744. The NVLAP program is administered by the National Institutes of Standards and Technology (NIST) of the U.S. Department of Commerce and provides third-party accreditation for testing and calibration laboratories. There are currently 24 NVLAP-accredited acoustical testing laboratories in the United States. NVLAP accreditation covering one or more specific testing procedures conducted in accordance with established test standards is awarded upon successful completion of an intensive onsite assessment that includes proficiency testing and documentation review. The ATL NVLAP accreditation currently applies specifically to its ISO 3744 soundpower- level determination procedure (see the photograph) and supporting ISO 17025 quality system, although all ATL operations are conducted in accordance with its quality system. The ATL staff is currently developing additional procedures to adapt this quality system to the testing of space flight hardware in accordance with International Space Station acoustic emission requirements.<

Akers, James C.↗

Deriving Deformable Mirror Performance Requirements in Simulation with Experimental Verification

Coronagraph instruments rely on predictable and stable deformable mirror (DM) surface displacement to achieve the contrast required to detect Earth-sized exoplanets orbiting nearby Solar-type stars. Anomalous DM behavior, such as unstable or pinned actuators, can limit contrast in coronagraphs. Simulating how these undesired behaviors affect the performance of a high contrast imaging architecture is important for developing requirements on their associated hardware. Simulating a vortex coronagraph (VC) with two deformable mirrors, this study quantifies how the number of pinned actuators affect the performance of Focal Plane Wavefront Sensing and Control algorithms using both Grid Search Electric Field Conjugation (EFC) and Planned EFC, which uses Beta-Bumping. The simulation also quantifies how various types of voltage noise such as zero-mean Gaussian noise, zero-mean periodic noise, and drift can affect the contrast of a VC during an observation run. A tolerance of a change in the Mean Normalized Intensity of ${1\times10^{-11}}$ is allocated to both types of error. If Planned EFC is used, only 1 pinned actuator on both DMs can be tolerated. If only pure Grid Search EFC is used the DMs cannot have any pinned actuators. For the case of zero-mean Gaussian noise and zero-mean periodic noise, one can tolerate a noise standard deviation of no more than ${\sigma = 0.45 \text{ mV}}$. For drift, we can only tolerate ${\sigma = 0.30 \text{ mV}}$ or less. These results show that the DM electronics and the DM themselves need to be nearly defect free to avoid having more than 1 pinned actuator. The electronics need to be tested for different types of noise statistics and that both the average and standard deviation of the noise should be measured.

Dean L. Palmer↗

Studies of temporal change using radar interferometry

Decorrelation of the radar signals with time, which is indicative of changes in the surface occurring during the period of time spanned by the images, is examined. It is concluded that the decorrelation effects due to thermal noise can be easily evaluated and removed, while those due to slight angular changes between flight tracks are negligible. Spatial baseline and rotation-induced decorrelation can be derived using the Fourier transform of the impulse response intensity, and increases linearly with baseline or rotation in an ideal system. Empirical results confirm that as the baseline increases, the overall correlation decreases due to spatial baseline noise.

Villasenor, John↗

Forecasting the Cross Correlation of Terahertz Intensity Mapper [C ii] Line Intensity Maps with Euclid Galaxies

We forecast that the Terahertz Intensity Mapper (TIM) cross-correlated with Euclid’s Deep Field Fornax (EDF-F), TIM × EDF-F, will detect the [C ii]-galaxy cross-power spectrum at a median redshift of 1.1 with ≳7σ confidence. The Poisson component of the cross-power spectrum at 0.1 ≤ k ≤ 10 h Mpc$^{−1}$ (i.e., cross-shot noise) will be detected at ≳3σ in four bins spanning 0.5 < z < 1.7. This measurement will constrain the mean [C ii] specific intensity over half of cosmic history and assess the degree to which Euclid-selected galaxies account for the [C ii] intensity observed by TIM. We find that TIM can detect the cross-power spectrum across a wide range of [C ii] intensity models.

Bracks, Justin S. [UCLA; Caltech; UPenn, Philadelp↗

Rapid paper spray mass spectrometry characterization of uranium and exemplar molecular species

The ability to detect and quantify the presence of specific inorganic elements and complexes is essential for environmental monitoring and nuclear safeguards applications. In this work, paper spray ionization mass spectrometry (PSI–MS) was used for the rapid chemical and isotopic characterization of trace inorganic species collected on cotton swipe substrates. Here, the direct analysis of cotton swipes using this ambient ionization technique led to fast sample analysis that retained original chemical information of the source material with minimal sample preparation. Mass spectra were collected on an atmospheric pressure ionization, high–resolution mass spectrometer for solutions containing uranyl acetate, uranyl chloride, uranyl nitrate, and uranyl tri– n –butylphosphate (uranyl–TBP) complexes. Gadolinium nitrate was used as an internal standard for the quantitative analysis of uranium. To demonstrate the ability to characterize inorganic contaminants in the presence of uranium, a multi–element inorganic standard containing U, Bi, Pb, Cd, Fe, and Zn was deposited onto cotton substrates and directly analyzed without purification. All elements doped on the cotton substrate were detected with strong signal–to–noise (S/N) ratios (S/N~1000 for UO 2 + on multi–element doped swipes) and high integrated intensities (>10 5 counts) from collection periods of approximately 1 min. Limits of detection were determined to be approximately 94 ng for UO 2 + and uranyl acetate through the measurement of ppb level solutions. The rapid analysis of uranium and other inorganic–containing samples while still retaining original chemical information (e.g. uranyl complexation) was demonstrated. Qualitative detection and speciation were achieved in less than 1 min of analysis. For uranium isotopic quantitation, longer accumulations (>15 min) can be sustained to improve the accuracy of minor 235 U isotopic abundance measurements to approximately 1% error.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Techniques for Handling Channeling in High Resolution Fourier Transform Spectra Recorded with Synchrotron Sources

Seven different techniques in dealing the problem of channel spectra in Fourier transform Spectroscopy utilizing synchrotron source were examined and compared. Five of these techniques deal with the artifacts (spikes) in the recorded interferogram which in turn result in channel spectra within the spectral domain. Such interferogram editing method include replacing these spikes with zeros, straight line, fitted polynomial curve, rescaled spike and spike reduced with Gauss Function. Another two techniques try to target this issue in the spectral domain instead by either generating a synthetic background simulating the channels or measuring the channels parameters (amplitude, spacing and phase) to use in the spectral fitting program. Results showed spectral domain techniques produces higher quality results in terms of signal to noise and fitting residual. The effect of each method on the line parameters such as position, intensity are air broadening are also measured and discussed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A red-emitting carborhodamine for monitoring and measuring membrane potential

Biological membrane potentials, or voltages, are a central facet of cellular life. Optical methods to visualize cellular membrane voltages with fluorescent indicators are an attractive complement to traditional electrode-based approaches, since imaging methods can be high throughput, less invasive, and provide more spatial resolution than electrodes. Recently developed fluorescent indicators for voltage largely report changes in membrane voltage by monitoring voltage-dependent fluctuations in fluorescence intensity. However, it would be useful to be able to not only monitor changes but also measure values of membrane potentials. This study discloses a fluorescent indicator which can address both. We describe the synthesis of a sulfonated tetramethyl carborhodamine fluorophore. When this carborhodamine is conjugated with an electron-rich, methoxy (-OMe) containing phenylenevinylene molecular wire, the resulting molecule, CRhOMe, is a voltage-sensitive fluorophore with red/far-red fluorescence. Using CRhOMe, changes in cellular membrane potential can be read out using fluorescence intensity or lifetime. In fluorescence intensity mode, CRhOMe tracks fast-spiking neuronal action potentials (APs) with greater signal-to-noise than state-of-the-art BeRST 1 (another voltage-sensitive fluorophore). CRhOMe can also measure values of membrane potential. The fluorescence lifetime of CRhOMe follows a single exponential decay, substantially improving the quantification of membrane potential values using fluorescence lifetime imaging microscopy (FLIM). The combination of red-shifted excitation and emission, mono-exponential decay, and high voltage sensitivity enable fast FLIM recording of APs in cardiomyocytes. The ability to both monitor and measure membrane potentials with red light using CRhOMe makes it an important approach for studying biological voltages.

59 BASIC BIOLOGICAL SCIENCES↗

INTEGRAL OBSERVATIONS OF THE {gamma}-RAY BINARY 1FGL J1018.6-5856

The Fermi Large Area telescope (Fermi-LAT) collaboration has recently reported that one of their detected sources, namely, 1FGL J1018.6-5856, is a new gamma-ray binary similar to LS 5039. This has prompted efforts to study its multi-frequency behavior. In this report, we present the results from 5.78 Ms International Gamma-Ray Astrophysics Laboratory (INTEGRAL) IBIS/ISGRI observations on the source 1FGL J1018.6-5856. By combining all the available INTEGRAL data, a detection is made at a significance level of 5.4{sigma} in the 18-40 keV band, with an average intensity of 0.074 counts s{sup -1}. However, we find that there is non-statistical noise in the image that effectively reduces the significance to about 4{sigma} and a significant part of the signal appears to be located in a 0.2-wide phase region, at phases 0.4-0.6 (where even the corrected significance amounts to 90% of the total signal found). Given the scarcity of counts, a variability is hinted at about 3{sigma} at the hard X-rays, with an anticorrelation with the Fermi-LAT periodicity. If this behavior were true, it would be similar to that found in LS 5039 and prompt observations with TeV telescopes at phases anticorrelated with the GeV maximum.

79 ASTRONOMY AND ASTROPHYSICS↗

Multiscale cyclic dynamics in light harvesting complex in presence of vibrations and noise

Starting from the many-body Schrödinger equation, in this work we derive a new type of Lindblad master equations describing a cyclic exciton/electron dynamics in the light harvesting complex and the reaction center. These equations resemble the master equations for the electric current in mesoscopic systems, and they go beyond the single-exciton description by accounting for the multi-exciton states accumulated in the antenna, as well as the charge-separation, fluorescence and photo-absorption. Although these effects take place on very different timescales, their inclusion is necessary for a consistent description of the exciton dynamics. Our approach reproduces both coherent and incoherent dynamics of exciton motion along the antenna in the presence of vibrational modes and noise. We applied our results to evaluate energy (exciton) and fluorescent currents as functions of sunlight intensity.

59 BASIC BIOLOGICAL SCIENCES↗

Spatial Heterodyne Raman Spectrometer (SHRS) for In Situ Chemical Sensing Using Sapphire and Silica Optical Fiber Raman Probes

A spatial heterodyne Raman spectrometer (SHRS), constructed using a modular optical cage and lens tube system, is described for use with a commercial silica and a custom single-crystal (SC) sapphire fiber Raman probe. The utility of these fiber-coupled SHRS chemical sensors is demonstrated using 532 nm laser excitation for acquiring Raman measurements of solid (sulfur) and liquid (cyclohexane) Raman standards as well as real-world, plastic-bonded explosives (PBX) comprising 1,3,5- triamino- 2,4,6- trinitrobenzene (TATB) and octahydro-1,3,5,7-tetranitro-1,3,5,7-tetrazocine (HMX) energetic materials. The SHRS is a fixed grating-based dispersive interferometer equipped with an array detector. Each Raman spectrum was extracted from its corresponding fringe image (i.e., interferogram) using a Fourier transform method. Raman measurements were acquired with the SHRS Littrow wavelength set at the laser excitation wavelength over a spectral range of ∼1750 cm −1 with a spectral resolution of ∼8 cm −1 for sapphire and ∼10 cm −1 for silica fiber probes. The large aperture of the SHRS allows much larger fiber diameters to be used without degrading spectral resolution as demonstrated with the larger sapphire collection fiber diameter (330 μm) compared to the silica fiber (100 μm). Unlike the dual silica fiber Raman probe, the dual sapphire fiber Raman probe did not include filtering at the fiber probe tip nearest the sample. Even so, SC sapphire fiber probe measurements produced less background than silica fibers allowing Raman measurements as close as ∼85 cm −1 to the excitation laser. Despite the short lengths of sapphire fiber used to construct the sapphire probe, well-defined, sharp sapphire Raman bands at 420, 580, and 750 cm −1 were observed in the SHRS spectra of cyclohexane and the highly fluorescent HMX-based PBX. SHRS measurements of the latter produced low background interference in the extracted Raman spectrum because the broad band fluorescence (i.e., a direct current, or DC, component) does not contribute to the interferogram intensity (i.e., the alternating current, or AC, component). SHRS spectral resolution, throughput, and signal-to-noise ratio are also discussed along with the merits of using sapphire Raman bands as internal performance references and as internal wavelength calibration standards in Raman measurements.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Experiments and Computational Theory for Electrical Breakdown in Critical Components: THz Imaging of Electronic Plasmas.

This report describes the development of ultra-short pulse laser (USPL) induced terahertz (THz) radiation to image electronic plasmas during electrical breakdown. The technique uses three pulses from two USPLs to (1) trigger the breakdown, (2) create a 2 picosecond (ps, 10 -12 s), THz pulse to illuminate the breakdown, and (3) record the THz image of the breakdown. During this three year internal research program, sub-picosecond jitter timing for the lasers, THz generation, high bandwidth (BW) diagnostics, and THz image acquisition was demonstrated. High intensity THz radiation was optically-induced in a pulse-charged gallium arsenide photoconductive switch. The radiation was collected, transported, concentrated, and co-propagated through an electro-optic crystal with an 800 nm USPL pulse whose polarization was rotated due to the spatially varying electric field of the THz image. The polarization modulated USPL pulse was then passed through a polarizer and the resulting spatially varying intensity was detected in a high resolution digital camera. Single shot images had a signal to noise of %7E3:1. Signal to noise was improved to %7E30:1 with several experimental techniques and by averaging the THz images from %7E4000 laser pulses internally and externally with the camera and the acquisition system (40 pulses per readout). THz shadows of metallic films and objects were also recorded with this system to demonstrate free-carrier absorption of the THz radiation and improve image contrast and resolution. These 2 ps THz pulses were created and resolved with 100 femtosecond (fs, 10 -15 s) long USPL pulses. Thus this technology has the capability to time-resolve extremely fast repetitive or single shot phenomena, such as those that occur during the initiation of electrical breakdown. The goal of imaging electrical breakdown was not reached during this three year project. However, plans to achieve this goal as part of a follow-on project are described in this document. Further modifications to improve the THz image contrast and resolution are proposed, and after they are made, images of photo-induced carriers in gallium arsenide and silicon will be acquired to evaluate image sensitivity versus carrier density. Finally electrical breakdown will be induced with the first USPL pulse, illuminated with THz radiation produced with the second USPL pulse and recorded with the third USPL pulse.