Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “NEUTRONS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 793 records · Page 44

Quasinormal g-modes of neutron stars with quarks

Quasinormal oscillation modes of neutron stars provide a means to probe their interior composition using gravitational wave astronomy. We compute the frequencies and damping times of composition-dependent core 𝑔-modes of neutron stars containing quark matter employing linearized perturbative equations of general relativity. We find that ignoring background metric perturbations due to the oscillating fluid, as in the Cowling approximation, underestimates the 𝑔-mode frequency by up to 10% for higher mass stars, depending on the parameters of the nuclear equation of state and how the mixed phase is constructed. The 𝑔-mode frequencies are well described by a linear scaling with the central lepton (or combined lepton and quark) fraction for nucleonic (hybrid) stars. Furthermore, our findings suggest that neutron stars with and without quarks are manifestly different with regards to their quasinormal 𝑔-mode spectrum, and may thus be distinguished from one another in future observations of gravitational waves from merging neutron stars.

79 ASTRONOMY AND ASTROPHYSICS↗

Electrobaryonic axion: hair of neutron stars

Axion-like particles are predicted in many physics scenarios beyond the Standard Model (SM). Their interactions with SM particles may arise from the triangle anomaly of the associated global symmetry, along with other SM global and gauge symmetries, including anomalies with the global baryon number and electromagnetic gauge symmetries. We initiate the phenomenological study of the corresponding “electrobaryonic axion”—a particle that couples with both the baryon chemical potential and the electromagnetic field. Neutron stars, particularly magnetars, possessing high baryon density and strong magnetic fields, can naturally develop a thin axion hair around their surface. In this study, we calculate this phenomenon, considering the effects of neutron star rotation and general relativity. For axion particles lighter than the neutron star rotation frequency, the anomalous interaction can also induce the emission of axion particles from the neutron star. In the light axion regime, this emission can significantly contribute to the neutron star cooling rate.

79 ASTRONOMY AND ASTROPHYSICS↗

Linear Reciprocating Tribometer for In Situ Neutron Reflectometry of Soft Matter

Neutron reflectometry is a technique for measuring structure near planar interfaces that has been previously used to non-destructively characterize the polymer density of hydrated, dilute, and soft materials. Previous investigations have conducted neutron reflectometry measurements of liquids, gels, emulsion, and polymer solutions at rest, in compression, and subject to shear stress. However, correlating structure with tribological properties of soft materials presents significant experimental challenges for prior instruments due to wall slip, sample thickness, and structural heterogeneity (e.g., depth-wise gradients). A linear reciprocating tribometer offers several advantages for in situ neutron reflectometry studies, including uniform velocity profiles, constant shear stress over large regions of interest, and independent control of normal force and sliding velocity during measurements. This work outlines basic considerations for the design of a custom linear reciprocating tribometer that operates in a neutron beamline and includes commissioning measurements. The tribometer is designed to compress soft and hydrated materials against linearly reciprocating silicon disks. The three key design considerations for this tribometer are (1) safety, (2) neutron transmission, and (3) sample positioning. This instrument design will enable in situ studies of soft matter and illuminate the role of interfacial structure on tribological phenomena.

42 ENGINEERING↗

Design-informed neutronics assessment of long-lived fission product transmutation in a tokamak fusion reactor blanket

This study presents a neutronics-based assessment of the feasibility and viability of transmuting six major long-lived fission products (LLFPs) from light-water reactors, namely 99 Tc, 129 I, 79 Se, 93 Zr, 126 Sn, and 135 Cs, within the blanket region of a tokamak fusion reactor, using the MIT ARC design as a concrete fusion configuration. Monte Carlo neutronics simulations were performed to evaluate LLFP transmutation and to compare the results with a reference boiling water reactor (BWR). The results indicate that transmutation of all six LLFPs is neutronics-feasible in fusion reactors, with transmutation half-lives significantly shorter than their natural decay half-lives. For elemental targets, transmutation of 135 Cs, 126 Sn, and 93 Zr was found potentially viable, as the net mass transmuted exceeded that achievable in the reference BWR under identical target volume and irradiation time. When isotopically separated targets were considered, transmutation of 126 Sn and 93 Zr appeared potentially viable. A parametric study demonstrated that plasma geometry modifications can enhance local neutron flux, increasing the transmuted 93 Zr mass by approximately 33% and reducing the transmutation half-life from approximately 240 years to 180 years. Repositioning the target and adjusting material layer thickness reduced the transmutation half-life of 93 Zr to 67 years and increased the net mass transmuted by a factor of 50. Furthermore, these results demonstrate that fusion reactors can enable LLFP transmutation beyond the practical limits of thermal fission reactors and highlight the critical role of reactor and blanket design optimization. Engineering and fuel-cycle considerations required for deployment are beyond the scope of this neutronics-focused study.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Through-thickness fracture behavior of neutron-irradiated nuclear graphite NBG-17 Using X-ray micro-CT

Achieving precise control over crack propagation in nuclear graphite and conducting quantitative analysis remain challenging. In this study, the through-thickness fracture behavior of pristine and neutron-irradiated (700 °C, ∼7 dpa) NBG-17 nuclear graphite was investigated using split-disc testing coupled with micro-computed tomography (micro-CT). A notably lower number of micropores was observed in the neutron-irradiated specimen. The fracture toughness of neutron-irradiated NBG-17 was measured to be 1.45 MPa√m, compared to 1.17 ± 0.05 MPa√m for the pristine specimen. In both materials, cracks were found to initiate at the filler–binder interface, and often correlated with microstructural features such as pores and thermal cracks. Crack bridging and deflections emerged as the primary toughening mechanisms in both unirradiated and irradiated NBG-17. However, compared with the pristine specimen, the cracks in the neutron-irradiated specimen were more likely to grow trans granularly, resulting in less deflected crack paths. The reduced micro-porosity and strengthened filler–binder boundaries were considered to be the cause of the observed differences in crack morphologies. In conclusion, this study provides a qualitative analysis of the fracture behavior of neutron-irradiated nuclear graphite in the absence of radiolytic oxidation.

36 - MATERIALS SCIENCE↗

Event-by-event neutron–photon multiplicity correlations in 252Cf(sf)

Excited nuclear fragments are emitted during nuclear fission. The de-excitation of these fission fragments takes place as sequential emission of neutrons followed by photons. A correlation between neutron and photon multiplicities accompanying fission is thus expected. Fission event generators based on established statistical nuclear physics models predict a negative event-by-event correlation in neutron-photon multiplicity. A survey of published experimental results of an event-by-event covariance between the neutron - photon multiplicities emitted following the spontaneous fission of 252 Cf is presented. Analytic unfolding expressions are developed in this work to determine the bias introduced by background sources, particle misclassification, pulse pileup, and inelastic photon production. The published experimental data are re-analyzed using these unfolding techniques and are found to be in qualitative agreement with the predictions of model-based calculations. Finally, in particular, we have concluded that there exists a significant event-by-event neutron-photon emission competition following the spontaneous fission of 252 Cf.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Sensitivity of the active neutron coincidence collar response during simulated and experimental fresh fuel assay

Verification of the fissile (and fertile) content in fresh nuclear fuel assemblies is conducted by the IAEA to enforce the Nuclear Non-Proliferation Treaty using the UNCL (Uranium Neutron Collar — Light Water Reactor Fuel). The UNCL uses an uncorrelated AmLi neutron source to interrogate the fuel, producing a signal of coincident fission neutrons (Doubles rate) used to assay 235 U content of the fuel. The cost of producing calibration assemblies and limited availability of diverse commercial assemblies at any one time historically restricted the ability to explore the full parameter space experimentally. Monte Carlo simulations can overcome this, but introduce additional sources of uncertainty. In this work, the sensitivity of simulations and measurements to various parameters is assessed for a reference 1616 PWR assembly of uniform 3.2% enrichment. Uncertainty contributions in this evaluation include: simulated AmLi neutron source spectrum, AmLi neutron emission rate, AmLi anisotropicity, high density polyethylene (HDPE) density, the precise position of the fuel assembly within the detector, and experimentally the statistical uncertainty. The overall total systematic uncertainty estimate for the simulation of the absolute/relative Doubles rates responses are estimated to be approximately 2.0%/1.5%, and for experimental measurements systematic uncertainty reduces to 1.1%. This analysis supports further work using the relative Doubles rates in place of measurements for updating and extending the UNCL analysis methodology as systematic uncertainty is reasonably small.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of stilbene-d 12 for neutron spectroscopy without time of flight

In this work, we have experimentally characterized the light-output response of a deuterated trans-stilbene (stilbene-d 12 ) crystal to quasi-monoenergetic neutrons in the 0.8 to 4.4 MeV energy range. These data allowed us to perform neutron spectroscopy measurements of a DT 14.1 MeV source and a 239 PuBe source by unfolding the impinging neutron spectrum from the measured light-output response. The stilbene-d 12 outperforms a 1 H-stilbene of similar size when comparing the shape of the unfolded spectra and the reference ones. These results confirm the viability of non-hygroscopic stilbene-d 12 crystal for direct neutron spectroscopy without need for time-of-flight measurements. This capability makes stilbene-d 12 a well suited detector for fast-neutron spectroscopy in many applications including nuclear reaction studies, radiation protection, nuclear non-proliferation, and space travel.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A compact neutron spectrometer system

A portable neutron spectrometer, nSpec, has been developed for passive interrogation of fast neutrons ( 1 MeV) from neutron sources. The design of the system includes four EJ-301 liquid scintillation cells, a custom stand, and tungsten caps for gamma-ray shielding. Data acquisition settings were optimized to provide a dynamic range of up to > 15 MeV neutron energy. Additionally, the detector response matrix was characterized using a time-of-flight method based on gamma-ray tagged neutron emission from 252 Cf. The spectrum unfolding was characterized using measured and simulated spectra of AmBe and 252 Cf with the GRAVEL and MLEM methods. Monte Carlo methods were used to examine the uncertainty propagation and determine sufficient counts for a measurement.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of 17 N as a time-tagged neutron source for calibration of large antineutrino detectors

Large antineutrino detectors hold the potential for remote nuclear reactor monitoring and discovery, which is of great interest for nonproliferation and treaty verification applications. Correlated-particle calibration sources are especially useful for large-volume designs based on detection of inverse beta-decay events, as the timing information of the coincident particles improves background rejection and event reconstruction. 17 N is a promising calibration source since it emits beta-correlated delayed neutrons and can be produced relatively easily using high-energy neutrons. In this work, we examine the feasibility of 17 N as a time-tagged calibration source for large antineutrino detectors. 17 N was produced using a DT neutron generator from a water sample enriched in 17 O, and the observed production rates were found to be consistent with previous measurements of the 17 O(n,p) 17 N reaction cross-section. As a result, time-tagging of 17 N delayed neutrons is demonstrated via beta-neutron coincidence measurements conducted using a specialized beta detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Systematic evaluation of fast neutron sensing with Cesium Hafnium Chloride

Cesium Hafnium Chloride (CHC) is a promising new scintillator for dual mode sensing of both neutrons and gamma-rays. The high chlorine content allows for both 35 Cl(n,p) 35 S and 35 Cl(n,α) 32 P reaction channels leading to reliable detection of fast neutrons. By utilizing pulse shape discrimination (PSD), these neutron interactions may be reliably separated from gamma-ray signals with a high figure-of-merit (FOM) after optimization of the PSD algorithm. Here, in this study, the PSD algorithm settings for CHC were systematically investigated using a bare 252 Cf and a lead shielded plutonium beryllium neutron source. It was found that the PSD algorithm settings affects both the FOM and the neutron detection efficiency, but a FOM as high as 4.5 for alpha particles was observed in one data processing scenario. Further, an intrinsic 5 parts per million alpha emitting contamination was observed in the sample, which we attribute to natural uranium.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An unstructured mesh based neutronics optimization workflow

We have developed a fully automated workflow to optimize the neutronics performance of the Second Target Station (STS) at the Oak Ridge National Laboratory’s Spallation Neutron Source. The optimization workflow starts with the parametrized solid CAD engineering models and converts them into the unstructured mesh (UM) models for the neutronics calculations with MCNP6.2. Calculations are executed and their results are loaded into the Dakota optimization toolkit. Dakota analyzes the results and proposes new geometry parameters for the next design iteration. The cycle repeats until the optimal parameters are found. The automated CAD to MCNP conversion, the use of high-fidelity UM models, and the use of modern optimizer are the key elements that advance the entire optimization workflow in comparison with the original workflow. The original workflow was based on a simplified constructive solid geometry (CSG) modeling with MCNPX, mcnp_pstudy tool, and an in-house optimizer. Herein to demonstrate the new workflow, we present a case of neutronics optimization of the moderator–reflector assembly (MRA). Apart from the MRA, the workflow can optimize other major STS components, such as the spallation target, neutron beamlines, radiation shielding, and various accelerator components. Importantly, the new workflow opens the door to the advanced multi-physics multi-parameter optimization and has the potential for use in other nuclear physics and accelerator applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Neutron resonance transmission analysis prototype system for thorium fuel cycle safeguards

Emerging thorium-based reactor designs and fuel cycles present challenges to traditional non-destructive assay techniques used in international safeguards. Specifically, assaying the masses of 233 U and 235 U when they are present together in samples with high gamma ray backgrounds is difficult because of similar passive neutron signatures and relatively weak gamma-ray emissions of 233 U. The Pacific Northwest National Laboratory (PNNL) and the Massachusetts Institute of Technology (MIT) are developing a compact neutron resonance transmission analysis (NRTA) system as one potential solution to these challenges. The NRTA technique provides isotopic information for a sample via neutron time-of-flight (TOF) measurements that exploit a sample’s epithermal neutron resonance cross-sections. A recently developed portable NRTA system uses a commercially available, pulsed deuterium-tritium neutron generator with a ~2 m flight path and a GS20 lithium glass scintillator detector. Finally, this paper describes the prototype NRTA system design, a refined radiation transport model of the system, preliminary measurements with thorium and uranium sources, and demonstration of a quantitative isotopic estimation algorithm.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Coupled neutronics and species transport simulation of the Molten Salt Reactor Experiment

This paper presents the development of coupling between the molten salt reactor species transport code Mole and the reactor physics code Griffin. Here, in this study, tracking of delayed neutron precursors was investigated in the Molten-Salt Reactor Experiment (MSRE), accounting for changes in fuel flow velocity as a function of position in the primary loop. The neutron transport calculations in Griffin were performed using 11 energy groups, and the species advection calculations in Mole used 6 delayed neutron precursor groups to predict spatial distribution of the neutron flux and neutron precursors in the MSRE. Mole–Griffin was used to calculate $k$ eff and $β$ eff in the reactor as a function of different volumetric flow rates.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Neutron elastic and inelastic scattering differential cross sections on carbon

Elastic and inelastic neutron scattering angular distributions were measured on natural carbon samples to confirm existing experimental data and evaluations in the fast neutron region and to guide improvements in resonance parameters, where needed. Sixty-four (n,n') differential cross section measurements were performed at 45 incident neutron energies between 0.5 and 8.0 MeV. Experimental angle-integrated elastic scattering cross sections are consistent with ENDF/B-VIII.0 values with the exception of the region from 3.2 to 4.0 MeV where our results are ~3% higher. In the 3.4 to 3.6 MeV region our differential cross sections are slightly lower at forward angles and somewhat higher at backward angles than the ENDF/B-VIII.0 calculations; however, our results are consistent with measured data from other research groups. The first- through fourth-order elastic scattering Legendre coefficients from fits to these experimental data are consistent with ENDF/B-VIII.0 values across this range of incident neutron energies. Inelastic scattering cross sections were measured at 12 incident neutron energies between 5.6 and 7.8 MeV. Angle-integrated cross sections agree well with the 1978 Perey and ENDF/B-VIII.0 values; however, the angular-distribution shapes deviate somewhat from the ENDF/B-VIII.0 calculations. These data will allow refinement of the resonance parameter description in this difficult energy region.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Neutron elastic and inelastic cross section measurements on silicon from 0.8--8 MeV

Neutron elastic and inelastic scattering differential cross sections were measured at angles between 30° and 155° with incident neutron energies between 0.8 and 8 MeV. The measured differential scattering cross sections are compared to existing measurements and the ENDF/B-VIII.0, the JEFF-3.3, and the JENDL-4.0 data evaluations, as well as theoretical calculations from the TALYS-1.95 nuclear reaction code. Our results are reasonably well described by values from the ENDF/B-VIII.0 and JEFF-3.3 compilations. However, below 4 MeV, our backward-angle elastic scattering results tend to be lower than database/calculated values, suggesting that less recoil damage would occur than expected. Above 6 MeV, larger backward-angle cross sections are observed suggesting the opposite. Deexcitation γ rays produced in the inelastic scattering process were also studied for neutron energies between 1.9 and 4.5 MeV. Inelastic neutron scattering cross sections deduced from 28 Si(n,n1γ) γ-ray projection cross sections confirm our 28 Si(n,n1) results. To the extent that data from GELINA and our experimental results can be compared, we have excellent agreement between the inelastic neutron scattering cross sections.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Enhanced Neutron and γ-Ray Detection via 6 Li Substitution in Undoped and Tl-Doped Zero-Dimensional Perovskite Cs 3 Cu 2 I 5 Scintillators

Radiation detectors are crucial in a wide variety of research and commercial applications, such as oil and gas exploration, medical imaging, nuclear nonproliferation, and homeland security. Neutron and gamma-ray detectors are fundamental components in portal monitors at ports and border crossings, bolstering national security against radiological threats. This study presents a dual-mode scintillator, undoped and Tl-doped 6 Li-Cs 3 Cu 2 I 5 , and demonstrates its potential as a promising material for simultaneous thermal neutron and gamma-ray detection. We explore the Bridgman growth of both undoped and thallium doped Li → Cu and Li → Cs substitutional systems with various Li doping levels and assess their impact on scintillation properties. Under 662 keV gamma-ray excitation, the undoped crystals had light yields up to 35,900 ph/MeV, with energy resolutions down to 4.5%. The Tl-doped crystals performed better than the undoped crystals with light yields peaking at 65,900 ph/MeV and energy resolutions as low as 3.5%. When exposed to a moderated 252 Cf excitation source, our crystals had light yields between 102,900 and 167,200 photons per thermal neutron capture, with a full energy thermal neutron peak reaching 3 MeV in gamma equivalent energy. Pulse shape discrimination studies reveal well-separated gamma and neutron events, resulting in Figure-Of-Merit (FOM) as high as 3.7. Furthermore, these findings highlight the potential of Li-doped Cs 3 Cu 2 I 5 as a viable candidate for next-generation dual-mode scintillators.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Vertically Self-Oriented, Ultrafast 1D ZnO:Li Nanorods as Scintillators for Thermal Neutron Detection

Detection of special nuclear materials (SNMs) is of vital importance in the prevention of nuclear terrorism and to secure states’ national security. Neutron detection is a particularly useful tool to identify SNM, and neutron-sensitive scintillators have many promising properties, such as ease of use, good time resolution, and high detection efficiency. In this work, we develop highly stable, self-oriented, ultrafast 1D ZnO:Li (and codoped with Al, Ga, and In) nanorods (NRs) as thermal neutron-sensitive scintillators. Lithium-6 has high thermal neutron cross section for the (n, α) reaction in ZnO:Li scintillators which have a vertical nano array design greatly increasing the effective surface area and scintillation efficiency. Cost-effective low-temperature (95 °C) hydrothermal growth is used to obtain highly crystalline ZnO:Li nano scintillators by combining nuclear range data and electron transport mechanisms. Among the studies using low-temperature hydrothermal synthesis and a relatively low annealing temperature (≈350 °C) along with optimized NRs (length ≈ 5–8 μm, mean diameter ≈ 700 nm) for thermal neutron detection, this study reports the shortest scintillation decay time (≈ 470 ps) so far to the best of our knowledge. In conclusion, this nano array scintillator combines the advantages of a low-cost growth technique with environmentally friendly and widely available materials.

Ions↗