Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MHZ RANGE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 793 records · Page 44

High-frequency ultrasonic characterization of sintered silicon carbide

High-frequency 60- to 160-MHz ultrasonic nondestructive evaluation was used to characterize variations in density and microstructural constituents of sintered SiC bars. Ultrasonic characterization methods included longitudinal velocity, reflection coefficient, and precise attenuation measurements. The SiC bars were tailored to provide bulk densities ranging from 90 to 98 percent of theoretical, average grain sizes ranging from 3.0 to 12.0 microns, and average pore sizes ranging from 1.5 to 4.0 microns. Velocity correlated with specimen bulk density irrespective of specimen average grain size, average pore size, and average pore orientation. The attenuation coefficient was found to be sensitive to both density and average pore size variations, but was not affected by large differences in average grain size.

Baaklini, George Y.↗

Rubidium atomic frequency standards for GPS Block IIR

The Rubidium Atomic Frequency Standards (RAFS) were provided for the GPS Block IIR NAVSTAR satellites. These satellites will replenish and upgrade the space segment of the Global Positioning System in the mid 1990s. The GPS RAFS Rb clocks are the latest generation of the high-performance rubidium frequency standards. They offer an aging rate in the low pp 10(exp 14)/day range and a drift-corrected 1-day stability in the low pp 10(exp 14) range. The Block IIR version of these devices will have improved performance, higher reliability, smaller size, and greater radiation hardness. The GPS Block IIR atomic clocks have a natural frequency configuration whereby they output a frequency of about 13.4 MHz that is a submultiple of the atomic resonance of Rb (or Cs). The RAFS operates at a low, fixed C-field for increased stability. The GPS Block IIR RAFS design, including the changes and improvements made, and the test results obtained are described.

Riley, William J.↗

Miniature X-band GaAs MMIC analog and bi-phase modulators for spaceborne communications applications

The design concepts, analyses, and the development of GaAs monolithic microwave integrated circuit (MMIC) linear-phase and digital modulators for the next generation of spaceborne communications systems are summarized. The design approach uses a very compact lumped-element, quadrature hybrid, and MESFET-varactors to provide low-loss and well-controlled phase performance for deep-space transponder (DST) applications. The measured results of the MESFET-diode show a capacitance range of 2:1 under reverse bias, and a Q of 38 at 10 GHz. Three cascaded sections of hybrid-coupled reflection phase shifters have been modeled and simulations performed to provide an X-band (8415 +/- 50 MHz) DST phase modulator with +/-2.5 radians of peak phase deviation.

Mysoor, Narayan R.↗

Temperature Dependence of Thin Film Spiral Inductors on Alumina Over a Temperature Range of 25 to 475 C

In this paper, we present an analysis of inductors on an Alumina substrate over the temperature range of 25 to 475 C. Five sets of inductors, each set consisting of a 1.5, 2.5, 3.5, and a 4.5 turn inductor with different line width and spacing, were measured on a high temperature probe station from 10 MHz to 30 GHz. From these measured characteristics, it is shown that the inductance is nearly independent of temperature for low frequencies compared to the self resonant frequency, the parasitic capacitances are independent of temperature, and the resistance varies nearly linearly with temperature. These characteristics result in the self resonant frequency decreasing by only a few percent as the temperature is increased from 25 to 475 C, but the maximum quality factor decreases by a factor of 2 to 3. These observations based on measured data are confirmed through 2D simulations using Sonnet software.

Ponchak, George E.↗

Note: Silicon Carbide Telescope Dimensional Stability for Space-based Gravitational Wave Detectors

Space-based gravitational wave detectors are conceived to detect gravitational waves in the low frequency range by measuring the distance between proof masses in spacecraft separated by millions of kilometers. One of the key elements is the telescope which has to have a dimensional stability better than 1 pm Hz(exp −1/2) at 3 mHz. In addition, the telescope structure must be light, strong, and stiff. For this reason a potential telescope structure consisting of a silicon carbide quadpod has been designed, constructed, and tested. We present dimensional stability results meeting the requirements at room temperature. Results at −60 C are also shown although the requirements are not met due to temperature fluctuations in the setup.

LISA-like↗

Analysis of the Tropospheric Doppler Radar Wind Profiler Measurement Accuracy

Space launch vehicle trajectory design uses atmospheric winds to determine vehicle performance and structural margin assessments prior to flight. For launches at the United States Space Force’s Eastern Range (ER) at the Cape Canaveral Space Force Station (CCSFS), tropospheric wind measurements come from either in-situ or remote sensing instrumentation. The use of the National Aeronautics and Space Administration’s (NASA) Kennedy Space Center (KSC) 48-MHz Tropospheric Doppler Radar Wind Profiler (TDRWP) has become the primary wind measurement source for several launch vehicles. Extensive evaluations of TDRWP data have occurred to quantify the system performance. This includes quantifying the accuracy of wind estimates over the entire sampling altitude as well as at discrete altitudes. This paper will describe methodology and analyses used to quantify the measurement accuracy of TDRWP data when operating in an alternative mission support mode over a 2-year period from March 2020 to March 2022.

Meghan E. Carrico↗

Analysis of the Tropospheric Doppler Radar Wind Profiler Measurement Accuracy

Space launch vehicle trajectory design uses atmospheric winds to determine vehicle performance and structural margin assessments prior to flight. For launches at the United States Space Force’s Eastern Range (ER) at the Cape Canaveral Space Force Station (CCSFS), tropospheric wind measurements come from either in-situ or remote sensing instrumentation. The use of the National Aeronautics and Space Administration’s (NASA) Kennedy Space Center (KSC) 48-MHz Tropospheric Doppler Radar Wind Profiler (TDRWP) has become the primary wind measurement source for several launch vehicles. Extensive evaluations of TDRWP data have occurred to quantify the system performance. This includes quantifying the accuracy of wind estimates over the entire sampling altitude as well as at discrete altitudes. This paper will describe methodology and analyses used to quantify the measurement accuracy of TDRWP data when operating in an alternative mission support mode over a 2-year period from March 2020 to March 2022.

Meghan E Carrico↗

Clusters of galaxies with a wide range of X-ray luminosities.

A search through 125 days of Uhuru data for X-ray emission from X-ray sources associated with Abell clusters is reported. X rays from 16 clusters have been observed. Ten of these are newly discovered and not listed in the previous Uhuru catalog. Seven cases, where the 22 MHz flux has been measured, show a wide spread of relative X-ray and radio luminosity. The discovery of low-richness clusters with high X-ray luminosity provides a possible explanation for some of the unidentified high-latitude X-ray sources.

Kellogg, E.↗

Wide-band observations of LF hiss at Frobisher Bay /L = 14.6/

Temporal and spectral characteristics of LF hiss recorded at Frobisher Bay from October 30 to November 18, 1972 and from June 27, 1974 to June 26, 1975 using a wide-band (0-100 kHz) receiver are reported and discussed. The hiss occurs in bursts of about 1 to 30 min duration with a bandwidth of at least 30 kHz centered in the 20-30 kHz range. Its frequency may extend downward below 10 kHz with decreasing intensity and upward to 100 kHz with increasing intensity. There is a strong diurnal peak of occurrence centered on 21 hours LMT. Some events simultaneously recorded by a 30-MHz rapid response riometer directly follow LF hiss bursts. Apparently some electron precipitation events produce hiss bursts only, others produce hiss and then a riometer event as the precipitation flux hardens, and others, too hard to produce hiss, produce riometer events only. An examination of the present data together with previous results (Jorgensen et al., 1962; Laaspere et al., 1976) leads to the conclusion that the precipitating electrons causing ground-observed LF hiss are more energetic and have smaller pitch angles than most auroral hiss observed in the topside atmosphere with an electric dipole antenna.

Morgan, M. G.↗

Dielectric Performance of a High Purity HTCC Alumina at High Temperatures - a Comparison Study with Other Polycrystalline Alumina

A very high purity (99.99+%) high temperature co-fired ceramic (HTCC) alumina has recently become commercially available. The raw material of this HTCC alumina is very different from conventional HTCC alumina, and more importantly there is no glass additive in this alumina material for co-firing processing. Previously, selected HTCC and LTCC (low temperature co-fired ceramic) alumina materials were evaluated at high temperatures as dielectric and compared to a regularly sintered 96% polycrystalline alumina (96% Al2O3), where 96% alumina was used as the benchmark. A prototype packaging system based on regular 96% alumina with Au thickfilm metallization successfully facilitated long term testing of high temperature silicon carbide (SiC) electronic devices for over 10,000 hours at 500 C. In order to evaluate this new high purity HTCC alumina for possible high temperature packaging applications, the dielectric properties of this HTCC alumina substrate were measured and compared with those of 96% alumina and a previously tested LTCC alumina from room temperature to 550 C at frequencies of 120 Hz, 1 KHz, 10 KHz, 100 KHz, and 1 MHz. A parallel-plate capacitive device with dielectric of the HTCC alumina and precious metal electrodes were used for measurements of the dielectric constant and dielectric loss of the co-fired alumina material in the temperature and frequency ranges. The capacitance and AC parallel conductance of the capacitive device were directly measured by an AC impedance meter, and the dielectric constant and parallel AC conductivity of the dielectric were calculated from the capacitance and conductance measurement results. The temperature and frequency dependent dielectric constant, AC conductivity, and dissipation factor of the HTCC alumina substrate are presented and compared to those of 96% alumina and a selected LTCC alumina. Other technical advantages of this new co-fired material for possible high packaging applications are also discussed.

Electronic packaging↗

Dielectric Performance of High Purity HTCC Alumina at High Temperatures - A Comparison Study with Other Polycrystalline Alumina

A very high purity (99.99+) high temperature co-fired ceramic (HTCC) alumina has recently become commercially available. The raw material of this HTCC alumina is very different from conventional HTCC alumina, and more importantly there is no glass additive in this co-fired material. Previously, selected HTCC and LTCC (low temperature co-fired ceramic) alumina materials were evaluated at high temperatures as dielectric and compared to a regularly sintered 96 polycrystalline alumina (96 Al2O3), where 96 alumina was used as the benchmark. A prototype packaging system based on regular 96 alumina with Au thick-film metallization successfully facilitated long term testing of high temperature silicon carbide (SiC) electronic devices for over 10,000 hours at 500C. In order to evaluate this new HTCC alumina for possible high temperature packaging applications, the dielectric properties of this HTCC alumina substrate were measured and compared with those of 96 alumina and a LTCC alumina from room temperature to 550C at frequencies of 120 Hz, 1 KHz, 10 KHz, 100 KHz, and 1 MHz. A parallel-plate capacitive device with dielectric of the HTCC alumina and precious metal electrodes were used for measurements of the dielectric constant and dielectric loss of the co-fired alumina material in the temperature and frequency ranges. The capacitance and AC parallel conductance of the capacitive device were directly measured by an AC impedance meter, and the dielectric constant and parallel AC conductivity of the dielectric were calculated from the capacitance and conductance measurement results. The temperature and frequency dependent dielectric constant, AC conductivity, and dissipation factor of the HTCC alumina substrate are presented and compared to those of 96 alumina. Other technical advantages of this new co-fired material for possible high packaging applications are also discussed.

High temperature↗

Gravitational Changes of the Earth's Free Oscillation From Earthquakes: Theory and Feasibility Study Using GRACE Inter‐Satellite Tracking

GRACE satellites have detected regional‐scale preseismic, coseismic, and postseismic gravity changes associated with great earthquakes during the GRACE era (2002‐2017). Earthquakes also excite global‐scale transient gravity changes associated with free oscillations that may be discerned for a few days. In this study, we examine such global gravity changes due to Earth's free oscillations and quantify how they affect GRACE measurements. We employ the normal mode formalism to synthesize the global gravity changes after the 2004 Sumatra earthquake and simulate the (gravitational) free oscillation signals manifested in the GRACE K‐band ranging (KBR) measurements. Using the Kaula orbit perturbation theory, we show how GRACE inter‐satellite distances are perturbed through a complex coupling of eigenfrequencies of the normal modes with the Earth's rotation rate and the GRACE satellites' orbital frequency. It is found that a few gravest normal modes can generate range‐rate perturbations as large as 0.2 μm/s, which are comparable to actual errors of GRACE KBR ranging and accelerometer instruments. Wavelet time‐frequency analysis of the GRACE KBR residual data in December 2004 reveals the existence of a significant transient signal after the 2004 Sumatra earthquake. This transient signal is characterized by a frequency of ~0.022 mHz that could be potentially associated with the largest excitation due to the “football” mode of the Earth's free oscillation. However, the results are also affected by low‐frequency noise of the GRACE accelerometers. Improved space‐borne gravitational instrumentation may open new opportunities to study the Earth's interior and earthquakes independently from global seismological analysis.

Ghobadi-Far, Khosro↗

A new method for determining the CO to H2 conversion factor for translucent clouds

In this paper we describe a new technique for obtaining the conversion factor between the molecular hydrogen column density and the CO(J = 1-0) integrated antenna temperature. This factor, typically known as X(sub CO) is often to be of order a few times 10(exp 20)/sq cm/K km/s) for the molecular clouds in the Galaxy and is one of the primary means of determining the molecular cloud mass from CO observations. However, for the low-extinction interstellar clouds known as the translucent molecular clouds, estimates of X(sub CO) vary by up to a factor of 60 depending on the object and techniques employed to calibrate X(sub CO). Since the cloud mass is directly proportional to X(sub CO) uncertainties in mass estimates of translucent clouds can be more than an order of magnitude. We calibrate the H2 content in translucent clouds by using the linear relationship between the CH and H2 column densities. The CH column density is readily determined from observations of the CH ground-state hyperfine main-line transition at 3335 MHz. Using CH as a surrogate tracer for H2 and CO(J = 1-0) observations of a sample of translucent and dark molecular clouds, we find a wide variation in values for X(sub CO). For translucent clouds, X(sub CO) ranges from 0.3 to 6.8 x 10(exp 20) and for dark clouds the values range from 0.8 to 8.6. Although the average values for both types of cloud are similar to the canonical value determined for the Galactic molecular cloud ensemble (2-4 x 10(exp 20)), the scatter in individual X(sub CO) values may indicate that X(sub CO) for a given translucent cloud cannot be determined a priori and must be obtained for each cloud so that a reliable mass determination may be made.

Magnani, L.↗

High-speed programmable photonic circuits in a cryogenically compatible, visible–near-infrared 200 mm CMOS architecture

Abstract Recent advances in photonic integrated circuits have enabled a new generation of programmable Mach–Zehnder meshes (MZMs) realized by using cascaded Mach–Zehnder interferometers capable of universal linear-optical transformations on N input/output optical modes. MZMs serve critical functions in photonic quantum information processing, quantum-enhanced sensor networks, machine learning and other applications. However, MZM implementations reported to date rely on thermo-optic phase shifters, which limit applications due to slow response times and high power consumption. Here we introduce a large-scale MZM platform made in a 200 mm complementary metal–oxide–semiconductor foundry, which uses aluminium nitride piezo-optomechanical actuators coupled to silicon nitride waveguides, enabling low-loss propagation with phase modulation at greater than 100 MHz in the visible–near-infrared wavelengths. Moreover, the vanishingly low hold-power consumption of the piezo-actuators enables these photonic integrated circuits to operate at cryogenic temperatures, paving the way for a fully integrated device architecture for a range of quantum applications.

47 OTHER INSTRUMENTATION↗

Ultrasonic velocity for estimating density of structural ceramics

The feasibility of using ultrasonic velocity as a measure of bulk density of sintered alpha silicon carbide was investigated. The material studied was either in the as-sintered condition or hot isostatically pressed in the temperature range from 1850 to 2050 C. Densities varied from approximately 2.8 to 3.2 g cu cm. Results show that the bulk, nominal density of structural grade silicon carbide articles can be estimated from ultrasonic velocity measurements to within 1 percent using 20 MHz longitudinal waves and a commercially available ultrasonic time intervalometer. The ultrasonic velocity measurement technique shows promise for screening out material with unacceptably low density levels.

Klima, S. J.↗

KSC 50-MHz Doppler Radar Wind Profiler (DRWP) Operational Acceptance Test (OAT) Report

This report documents analysis results of the Kennedy Space Center updated 50-MHz Doppler Radar Wind Profiler (DRWP) Operational Acceptance Test (OAT). This test was designed to demonstrate that the new DRWP operates in a similar manner to the previous DRWP for use as a situational awareness asset for mission operations at the Eastern Range to identify rapid changes in the wind environment that weather balloons cannot depict. Data examination and two analyses showed that the updated DRWP meets the specifications in the OAT test plan and performs at least as well as the previous DRWP. Data examination verified that the DRWP provides complete profiles every five minutes from 1.8-19.5 km in vertical increments of 150 m. Analysis of 5,426 wind component reports from 49 concurrent DRWP and balloon profiles presented root mean square (RMS) wind component differences around 2.0 m/s. The DRWP's effective vertical resolution (EVR) was found to be 300 m for both the westerly and southerly wind component, which the best EVR possible given the DRWP's vertical sampling interval. A third analysis quantified the sensitivity to rejecting data that do not have adequate signal by assessing the number of first-guess propagations at each altitude. This report documents the data, quality control procedures, methodology, and results of each analysis. It also shows that analysis of the updated DRWP produced results that were at least as good as the previous DRWP with proper rationale. The report recommends acceptance of the updated DRWP for situational awareness usage as per the OAT's intent.

Profiler↗

Considerations on wakefield effects in a VUV FELO driven by a superconducting tesla-type linac

The effects on beam dynamics from long-range and short-range wakefields from TESLA-type cavities are considered in regard to a proposed FEL oscillator (FE-LO) operating at 120 nm. This would be driven by the Fermilab Accelerator Science and Technology (FAST) linac at 300 MeV with a 3-MHz micropulse repetition rate. Our wakefield studies showed measurable effects on submacropulse centroid stability and on submicropulse head-tail kicks that can lead to emittance degradation. In the case of the former, we use MINERVA/OPC to simulate the ~100-$\mu$m centroid slew effects on the saturated output power levels of the FELO.

43 PARTICLE ACCELERATORS↗

Silicon Carbide Telescope Investigations for the LISA Mission

Space-based gravitational wave (GW) detectors are conceived to detect GWs in the low frequency range (mili-Hertz) by measuring the distance between free-falling proof masses in spacecraft (SC) separated by 5 Gm. The reference in the last decade has been the joint ESA-NASA mission LISA. One of the key elements of LISA is the telescope since it simultaneously gathers the light coming from the far SC (approximately or equal to 100 pW) and expands, collimates and sends the outgoing beam (2 W) to the far SC. Demanding requirements have been imposed on the telescope structure: the dimensional stability of the telescope must be approximately or equal to 1pm Hz(exp−1/2) at 3 mHz and the distance between the primary and the secondary mirrors must change by less than 2.5 micrometer over the mission lifetime to prevent defocussing. In addition the telescope structure must be light, strong and stiff. For this reason a potential on-axis telescope structure for LISA consisting of a silicon carbide (SiC) quadpod structure has been designed, constructed and tested. The coefficient of thermal expansion (CTE) in the LISA expected temperature range has been measured with a 1% accuracy which allows us to predict the shrinkage/expansion of the telescope due to temperature changes, and pico-meter dimensional stability has been measured at room temperature and at the expected operating temperature for the LISA telescope (around -6[deg]C). This work is supported by NASA Grants NNX10AJ38G and NX11AO26G,

carbide↗