Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MAMMALS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 793 records · Page 44

Cisplatin-Conjugated Porous Gelatin Particles: Assessment of Optimal Conditions for Binding and Release

This study was designed to evaluate the optimal conditions for binding cisplatin and porous gelatin particles (PGPs) and to establish in vivo drug release pharmacokinetics. PGPs were immersed in cisplatin solutions under different conditions: concentration, immersion time, and temperature. Thereafter, PGPs were washed in distilled water to remove uncombined cisplatin and were then freeze-dried. The platinum concentration (PC) in the PGPs was then measured. For the in vivo release test, 50 mg/kg of the cisplatin-conjugated PGPs was implanted subcutaneously in the abdominal region of two rabbits. PCs in the blood were measured at different time intervals. PCs significantly increased in direct proportion to the concentration and immersion time (p < 0.01). Although PC increased at higher solution temperature, it was not a linear progression. For the in vivo release test, platinum was released from cisplatin-conjugated PGPs after 1 day, and the peak PC was confirmed 2 days after implantation. Platinum in the blood was detected until 7 days after implantation in one rabbit and 15 days after administration in the other rabbit. Platinum binding with PGPs increased with a higher concentration of cisplatin solution at a higher temperature over a longer duration of time. Release of cisplatin from cisplatin-conjugated PGPs was confirmed in vivo.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

External Carotid-Internal Jugular Fistula as a Late Complication After Carotid Endarterectomy: A Rare Case

A 66-year-old man presented with mild amnesia, progressive fatigue, ataxia, visual hallucinations, and debility. His past medical history included right-sided carotid endarterectomy performed elsewhere 6 years previously. Cranial magnetic resonance imaging showed left parieto-occipital arteriovenous malformation-like tortous vessels, venous congestion, and ischemic areas. Cerebral angiography showed right-sided compound external carotid artery-internal jugular vein (IJV) fistula, and distal occlusion of the right IJV. Transvenous embolization via contralateral IJV was performed, and the fistula, together with fistulous portion of the distal IJV, was sealed using coils. Two years later, patient is well with normal neurologic examination findings. The presence of an arteriovenous communication after vascular surgery is a serious complication with potential long-term effects and therefore should be diagnosed and treated as promptly as possible.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Initial Experience with Computed Tomography and Fluoroscopically Guided Placement of Push-Type Gastrostomy Tubes Using a Rupture-Free Balloon Catheter

The purpose of this study was to evaluate the safety and feasibility of percutaneous radiologic gastrostomy placement of push-type gastrostomy tubes using a rupture-free balloon (RFB) catheter under computed tomography (CT) and fluoroscopic guidance. A total of 35 patients (23 men and 12 women; age range 57-93 years [mean 71.7]) underwent percutaneous CT and fluoroscopically guided gastrostomy placement of a push-type gastrostomy tube using an RFB catheter between April 2005 and July 2008. Technical success, procedure duration, and complications were analyzed. Percutaneous radiologic gastrostomy placement was considered technically successful in all patients. The median procedure time was 39 {+-} 13 (SD) min (range 24-78). The average follow-up time interval was 103 days (range 7-812). No major complications related to the procedure were encountered. No tubes failed because of blockage, and neither tube dislodgement nor intraperitoneal leakage occurred during the follow-up period. The investigators conclude that percutaneous CT and fluoroscopically guided gastrostomy placement with push-type tubes using an RFB catheter is a safe and effective means of gastric feeding when performed by radiologists.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Initial Experience of Uterine Fibroid Embolization Using Porous Gelatin Sponge Particles

The purpose of this study was to prospectively assess the safety and effectiveness of uterine artery embolization (UAE) using porous gelatin particle (PGP; Gelpart; Asuterasu, Tokyo, Japan) for symptomatic uterine fibroids. Twenty-five consecutive premenopausal women underwent UAE with PGP. The angiographic end point of embolization was near stasis of the ascending uterine artery. Pelvic magnetic resonance imaging (MRI) was obtained before and after the procedure. Complications were assessed. The outcomes of technique, infarction rates of all fibroid tissue after UAE with contrast-enhanced MRI, change in symptoms and quality of life using serial Uterine Fibroid Symptom and Quality of Life (UFS-QOL) questionnaires, and additional interventions were evaluated. Bilateral UAE was successfully performed in all patients. Enhanced MRI 1 week after UAE showed that 100% infarction of all fibroid tissue was achieved in 65% (15 of 23) of patients; 90-99% infarction was achieved in 35% (8 of 23) of patients. Mean follow-up was 12 months (range 1-20). Symptom and QOL scores at baseline were 47.2 and 61.7, respectively. Both scores significantly improved to 26.3 (P < 0.001) and 82.4 (P < 0.001) at 4 months and to 20.4 (P < 0.001) and 77.6 (P < 0.001) at 1 year, respectively. No additional gynecologic interventions were performed in any patient. There were no major complications. Minor complications occurred in two patients. UAE using PGP is a safe and effective procedure and shows that outcomes after UAE, as measured with enhanced MRI and UFS-QOL questionnaires, seem comparable with those of UAE using other embolic agents. PGP is a promising embolic agent used for UAE to treat symptomatic uterine fibroids. Further comparative study between PGP and other established embolic agents is required.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Optease Vena Cava Filter Optimal Indwelling Time and Retrievability

The purpose of this study was to assess the indwelling time and retrievability of the Optease IVC filter. Between 2002 and 2009, a total of 811 Optease filters were inserted: 382 for prophylaxis in multitrauma patients and 429 for patients with venous thromboembolic (VTE) disease. In 139 patients [97 men and 42 women; mean age, 36 (range, 17-82) years], filter retrieval was attempted. They were divided into two groups to compare change in retrieval policy during the years: group A, 60 patients with filter retrievals performed before December 31 2006; and group B, 79 patients with filter retrievals from January 2007 to October 2009. A total of 128 filters were successfully removed (57 in group A, and 71 in group B). The mean filter indwelling time in the study group was 25 (range, 3-122) days. In group A the mean indwelling time was 18 (range, 7-55) days and in group B 31 days (range, 8-122). There were 11 retrieval failures: 4 for inability to engage the filter hook and 7 for inability to sheathe the filter due to intimal overgrowth. The mean indwelling time of group A retrieval failures was 16 (range, 15-18) days and in group B 54 (range, 17-122) days. Mean fluoroscopy time for successful retrieval was 3.5 (range, 1-16.6) min and for retrieval failures 25.2 (range, 7.2-62) min. Attempts to retrieve the Optease filter can be performed up to 60 days, but more failures will be encountered with this approach.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Superior Mesenteric Artery Embolism Treated with Percutaneous Mechanical Thrombectomy

A case of acute superior mesenteric artery embolism treated with percutaneous thrombus aspiration is described. A 63-year-old man with chronic atrial fibrillation was admitted to the hospital with progressive abdominal pain. Computed tomography angiography revealed an occlusion of the distal part of the superior mesenteric artery. The patient was effectively treated using transaxillary percutaneous mechanical thrombectomy using a 6F Aspirex thrombectomy catheter.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Endovascular Revascularization of Chronically Thrombosed Arteriovenous Fistulas and Grafts for Hemodialysis: A Retrospective Study in 15 Patients With 18 Access Sites

The current study retrospectively evaluated whether endovascular revascularization of chronically thrombosed and long-discarded vascular access sites for hemodialysis was feasible. Technical and clinical success rates, postintervention primary and secondary patency rates, and complications were reported. During a 1-year period, we reviewed a total of 924 interventions performed for dysfunction and/or failed hemodialysis vascular access sites and permanent catheters in 881 patients. In patients whose vascular access-site problems were considered untreatable or were considered treatable with a high risk of failure and access-site abandonment, we attempted to revascularize (resurrect) the chronically occluded and long-discarded (mummy) vascular access sites. We attempted to resurrect a total of 18 mummy access sites (mean age 46.6 {+-} 38.7 months; range 5-144) in 15 patients (8 women and 7 men; mean age 66.2 {+-} 11.5 years; age range 50-85) and had an overall technical success rate of 77.8%. Resurrection failure occurred in 3 fistulas and in 1 straight graft. The clinical success rate was 100% at 2 months after resurrection. In the 14 resurrected vascular access sites, 6 balloon-assisted maturation procedures were required in 5 fistulas; after access-site maturation, a total of 22 interventions were performed to maintain access-site patency. The mean go-through time for successful resurrection procedures was 146.6 {+-} 34.3 min (range 74-193). Postmaturation primary patency rates were 71.4 {+-} 12.1% at 30 days, 57.1 {+-} 13.2% at 60 days, 28.6 {+-} 13.4% at 90 days, and 19 {+-} 11.8% at 180 days. Postmaturation secondary patency rates were 100% at 30, 60, and 90 days and 81.8 {+-} 11.6% at 180 days. There were 2 major complications consisting of massive venous ruptures in 2 mummy access sites during balloon dilation; in both cases, prolonged balloon inflation failed to achieve hemostasis, but percutaneous N-butyl cyanoacrylate glue seal-off was performed successfully. Percutaneous resurrection of mummy vascular access sites for hemodialysis is technically feasible with high clinical success rates. In selected patients, resurrection of mummy access sites provides long-discarded access sites one more chance to be used for hemodialysis in an effort to preserve potential extremity sites for future access-site placement and to prevent long-term catheter indwelling.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

CT-Guided Percutaneous Drainage of Infected Collections Due to Gastric Leak After Sleeve Gastrectomy for Morbid Obesity: Initial Experience

This study was designed to evaluate the efficacy and safety of computed tomography (CT)-guided drainage in treating infected collections due to gastric leak after laparoscopic sleeve gastrectomy for morbid obesity. From January 2007 to June 2009, 21 patients (9 men and 12 women; mean age, 39.2 (range, 26-52) years) with infected collections due to gastric leak after laparoscopic sleeve gastrectomy for morbid obesity underwent image-guided percutaneous drainage. All procedures were performed using CT guidance and 8- to 12-Fr pigtail drainage catheters. Immediate technical success was achieved in all 21 infected collections. In 18 of 21 collections, we obtained progressive shrinkage of the collection with consequent clinical success (success rate 86%). In three cases, the abdominal fluid collection was not resolved, and the patients were reoperated. Among the 18 patients who avoided surgery, 2 needed replacement of the catheter due to obstruction. No major complications occurred during the procedure. The results of our study support that CT-guided percutaneous drainage is an effective and safe method to treat infected abdominal fluid collections due to gastric leak in patients who had previously underwent laparoscopic sleeve gastrectomy for morbid obesity. It may be considered both as a preparatory step for surgery and a valuable alternative to open surgery. Failure of the procedure does not, however, preclude a subsequent surgical operation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Metachronous Bilateral Posterior Tibial Artery Aneurysms in Ehlers-Danlos Syndrome Type IV

Ehlers-Danlos syndrome type IV is a life-threatening genetic connective tissue disorder. We report a 24-year-old woman with EDS-IV who presented with metachronous bilateral aneurysms/pseudoaneurysms of the posterior tibial arteries 15 months apart. Both were treated successfully with transarterial coil embolization from a distal posterior tibial approach.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Novel Application of Percutaneous Cryotherapy for the Treatment of Recurrent Oral Bleeding From a Noninvoluting Congenital Hemangioma Involving the Right Buccal Space and Maxillary Tuberosity

Cryotherapy is the application of varying extremes of cold temperatures to destroy abnormal tissue. The intent of this article is to describe a novel technique using percutaneous cryotherapy for treating a noninvoluting congenital craniofacial hemangioma (NICH). An 18-year-old woman with type 1 von Willebrand's disease, as well as a qualitative platelet aggregation disorder, presented with multiple recurrent episodes of oral bleeding from a NICH involving the right buccal space and maxillary tuberosity. The patient was initially treated with a combination of endovascular particulate embolization, percutaneous sclerotherapy, tissue cauterization, and laser therapy between the ages of 4 and 8 years of age. At 18 years of age, the patient presented with recurrent episodes of oral bleeding related to the NICH. Endovascular embolization was performed using particulate and a liquid embolic agent with limited success. Due to the refractory nature of this bleeding, the patient underwent successful lesion ablation using percutaneous cryotherapy. At 9-month follow-up, the patient is asymptomatic with no episodes of recurrent bleeding.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Porous Gelatin Particles for Uterine Artery Embolization: An Experimental Study of Intra-Arterial Distribution, Uterine Necrosis, and Inflammation in a Porcine Model

PurposeWe evaluated the location of porous gelatin particles (GP; Gelpart; Nippon Kayaku/Astellas, Tokyo, Japan) within the arterial vasculature and their acute effects on uterine necrosis and inflammation after uterine artery embolization (UAE) in swine.Materials and MethodsAdult nonpregnant pigs (n = 6) were allocated to either 1- (n = 3) or 2-mm GP (n = 3). Superselective and bilateral embolization of the uterine arteries was performed. All animals were killed 1 week after UAE. Macroscopic and microscopic findings, including the level of arterial occlusion and their effect on uterine necrosis and inflammation, were analyzed.ResultsAll UAE procedures were completed without severe complications. The macroscopic necrosis was seen in two animals in the 2-mm group with an extent of <50%. The location of the occluded arteries did not differ significantly between groups. The median diameters of the occluded arteries were 449 {mu}m (95% confidence interval [CI] 417-538 {mu}m) in the 1-mm GP group and 484 {mu}m (95% CI 370-560 {mu}m) in the 2-mm GP group. As for microscopic necrosis, no statistically significant difference was observed. The qualitative inflammatory reaction was significantly greater in the 2-mm GP group than in the 1-mm group (p < 0.001).ConclusionsBoth 1- and 2-mm GP occluded the arteries relevant to the target diameter for UAE in porcine uterus, presumably due to the plastic deformity. Both sizes of GP were associated with limited areas of necrosis; however, evaluation of inflammatory reaction was preliminary. Further study with adequate evaluation of inflammatory reactions is suggested.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Sustained Growth of the Ex Vivo Ablation Zones' Critical Short Axis Using Gas-cooled Radiofrequency Applicators

Purpose: To evaluate the ablation zones created with a gas-cooled bipolar radiofrequency applicator performed on ex vivo bovine liver tissue. Materials and Methods: A total of 320 ablations with an internally gas-cooled bipolar radiofrequency applicator were performed on fresh ex vivo bovine liver tissue, varying the ablation time (5, 10, 15, and 20 min), power (20, 30, 40, and 50 W), and gas pressure of the CO{sub 2} used for cooling (585, 600, 615, 630, 645 psi), leading to a total of 80 different parameter combinations. Size and shape of the white coagulation zone were assessed. Results: The largest complete ablation zone was achieved after 20 min of implementing 50 W and 645 psi, resulting in a short axis of mean 46 {+-} 1 mm and a long axis of 56 {+-} 2 mm (mean {+-} standard deviation). Short-axis diameters increased between 5 and 20 min of ablation time at 585 psi (increase of the short axis was 45% at 30 W, 29% at 40 W, and 39% at 50 W). This increase was larger at 645 psi (113% at 30 W, 67% at 40 W, and 70% at 50 W). Macroscopic assessment and NADH (nicotinamide adenine dinucleotide) staining revealed incompletely ablated tissue along the needle track in 18 parameter combinations including low-power settings (20 and 30 W) and different cooling levels and ablation times. Conclusion: Gas-cooled radiofrequency applicators increase the short-axis diameter of coagulation in an ex vivo setting if appropriate parameters are selected.

60 APPLIED LIFE SCIENCES↗

2D Rotational Angiography for Fast and Standardized Evaluation of Peripheral and Visceral Artery Stenoses

Purpose: To investigate the value of rotational digital subtraction angiography (rDSA) for evaluation of peripheral and visceral artery stenoses compared to conventional digital subtraction angiography (cDSA). Methods: A phantom study was performed comparing the radiation dose of cDSA with two projections and rDSA by means of the 2D Dynavision technique (Siemens Medical Solutions, Forchheim, Germany). Subsequently, 33 consecutive patients (18 women, 15 men; mean {+-} SD age 67 {+-} 15 years) were examined by both techniques. In total, 63 vessel segments were analyzed by two observers with respect to stenoses, image contrast, and vessel sharpness. Results: Radiation dose was significantly lower with rDSA. cDSA and rDSA revealed 21 and 24 flow-relevant stenotic lesions and vessel occlusions (70-100%), respectively. The same stenosis grade was assessed in 45 segments. By means of rDSA, 10 lesions were judged to have a higher and 8 lesions a lower stenosis grade compared to cDSA. rDSA yielded additive information regarding the vessel anatomy and pathology in 29 segments. However, a tendency toward better image quality and sharper vessel visualization was seen with cDSA. Conclusion: rDSA allows for multiprojection assessment of peripheral and visceral arteries and provides additional clinically relevant information after a single bolus of contrast medium. At the same time, radiation dose can be significantly reduced compared to cDSA.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

New Coaxial Transseptal Needle for Creation of Atrial Septal Defects in Adult Sheep

Objectives: To introduce a new transseptal (TS) needle assembled in our laboratory-the coaxial TS (CTS) needle-and describe our experience with it in creating experimental atrial septal defects (ASD) in adult sheep.BackgroundWith commercially available TS needles, we were not able to consistently perform TS puncture at the fossa ovalis in adult sheep.Material and MethodsTen adult sheep with a mean weight of 63.5 kg were used. The CTS needle consists of four components: a 9F Teflon catheter, a 14-gauge blunt curved-tip metal cannula, a 4F tapered catheter, and a 20-gauge open needle. A transjugular 5F pigtail catheter was used to display the septal anatomy by angiocardiography and was left in place to mark the level of the fossa ovalis. The septum was then probed by a transfemoral 5F curved-tip end-hole catheter. The CTS needle was aligned with the tip of the transjugular catheter, and the TS puncture was performed under fluoroscopic guidance. After documenting a left atrial position, a balloon angioplasty catheter was used for creation of the ASD. Results: A small patent foramen ovale was discovered by septal probing in one sheep. All sheep underwent successful TS punctures without complications. The ASD size ranged from 13 to 15 mm. In eight sheep, the ASD was in fossa ovalis. In the first two sheep where the needle was not well aligned with the marking catheter, the ASD was in the septum secundum. No damage to the atrial or other heart structures was found at necropsy. Conclusion: The CTS needle is a suitable needle for TS puncture and ASD creation in adult sheep. Proper alignment of the CTS needle with a catheter marking the fossa ovalis is essential for successful puncture.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Transcatheter Arterial Embolization for Spontaneous Rupture of the Omental Artery

We encountered a rare case of spontaneous rupture of the omental artery. A 25-year-old man without any episode of abdominal trauma or bleeding disorders came to the emergency unit with left upper abdominal pain. Hematoma with extravasation of the greater omentum and a hemoperitoneum was confirmed on abdominal contrast-enhanced computed tomography. Bleeding from the omental artery was suspected based on these findings. Transcatheter arterial embolization was successfully performed after extravasation of the omental artery, which arises from the left gastroepiploic artery, was confirmed on arteriography. Partial ometectomy was performed 10 days after transcatheter arterial embolization, revealing that the hematoma measured 10 cm in diameter in the greater omentum. Pathological examination showed rupture of the branch of an omental artery without abnormal findings, such as an aneurysm or neoplasm. Thus, we diagnosed him with spontaneous rupture of the omental artery. The patient recovered and was discharged from the hospital 10 days after the surgery, with a favorable postoperative course.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Irreversible Electroporation of Renal Cell Carcinoma: A First-in-Man Phase I Clinical Study

Purpose: Irreversible electroporation (IRE) is a newly developed nonthermal tissue-ablation technique in which high-voltage electrical pulses of microsecond duration are applied to induce irreversible permeabilisation of the cell membrane, presumably through nanoscale defects in the lipid bilayer, leading to apoptosis. The purpose of this study was to assess the feasibility and safety of ablating renal cell carcinoma (RCC) tissue by IRE. Methods: Six patients scheduled for curative resection of RCC were included. IRE was performed during anaesthesia immediately before the resection with electrographic synchronisation. Central haemodynamics were recorded before and 5 min after electroporation. Five-channel electrocardiography (ECG) was used for detailed analysis of ST waveforms. Blood sampling and 12-lead ECG were performed before, during, and at scheduled intervals after the intervention. Results: Analysis of ST waveforms and axis deviations showed no relevant changes during the entire study period. No changes in central haemodynamics were seen 5 min after IRE. Similarly, haematological, serum biochemical, and ECG variables showed no relevant differences during the investigation period. No changes in cardiac function after IRE therapy were found. One case of supraventricular extrasystole was encountered. Initial histopathologic examination showed no immediate adverse effects of IRE (observation of delayed effects will require a different study design). Conclusion: IRE seems to offer a feasible and safe technique by which to treat patients with kidney tumours and could offer some potential advantages over current thermal ablative techniques.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Ruptured Aneurysm of Intercostal Arteriovenous Malformation Associated With Neurofibromatosis Type 1: A Case Report

Intercostal arteriovenous malformations (AVM) are rare, with most being secondary to trauma or iatrogenic therapeutic procedures. Only one case of presumably congenital AVM has been reported. Here we report the first case of a ruptured aneurysm of intercostal AVM associated with neurofibromatosis type 1 in a 32-year-old woman who experienced hypovolemic shock caused by massive hemothorax.

62 RADIOLOGY AND NUCLEAR MEDICINE↗